Search NASA⌕ Search

SEARCH · Search NASA

Results for “Barcode sequencing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Novel Approach to Quantification of Telomere Length with Direct Nanopore Sequencing and PCR Amplification

The ends of human chromosomes contain telomeres, or tandem arrays of repeating DNA sequences capped by multiple associated proteins that protect chromosomal ends from degradation. Telomeres function to preserve genomic stability by preventing natural chromosomal ends from being recognized as broken DNA double-strand breaks and triggering inappropriate DNA damage responses. Mounting evidence shows telomere length is an inherited trait that decreases with cellular division and normal aging. In addition, telomere length also appears to be influenced by other factors such as cellular oxidative stress, radiation and mechanical unloading of tissues as in microgravity. To measure these potential effects of the space environment on telomere lengths and cellular aging and regenerative potential we developed a novel telomere measurement approach based on nanopore sequencing of PCR amplified bar-coded chromosome termini. Specifically, telomeres can be directly enriched using barcode sequences ligated to the end of a free end- repaired telomere using the WetLab-2 facility SmartCycler on ISS. Prior to the ligation and amplification protocol a proteinase K digestion of capping proteins followed by a single 95-degree C heat denaturation of the protease is included. After digestion and bar-code ligation, PCR amplification will initiate with the ligated barcoded sequence, suppressing amplification of intra-genomic fragments and resulting in long read barcoded telomere amplicons including the nanopore motor protein sequences. Purified PCR amplicons are then used for nanopore sequencing library generation by simple addition of motor proteins and sequencing library is loaded into the MinION nanopore DNA-sequencer. Amplicon sequence reads from the nanopore device can be base-called quickly on ISS due to barcoding ligation and subsequent PCR amplification enhancing the telomere sequence resolution. If successfully implemented on ISS this technique will provide a novel means of measuring regenerative ability of somatic stem cells in astronauts, and of determining whether spaceflight in microgravity alters their telomere lengths and causes premature cellular aging.

Ma, Kristin R.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

Deciphering the Effects of Microgravity Cell by Cell

Forces generated by gravity have a profound impact on the behavior of cells in tissues affecting the course of the cell cycle and differentiation fate of progenitors in mammalian tissues. These cells are contributing to normal tissue regenerative health and defence against disease. In Human space exploration context, it is extremely important to determine spaceflight provoked changes in tissue's regenerational capabilities. Microgravity experienced during spaceflight causes unloading and mechanical disuse on all orthostatic support tissues, therefore impacting stem cell fate and lineage commitment decisions. Investigating how ESCs respond to mechanical stimulation is a platform for fundamental developmental and regeneration research applicable for spaceflight. However, the gene expression programs associatiated with early committment stem cell pathways in response to physical stimulation are not readily known. Single-cell RNA-seq technologies have recently revolutionized the world of molecular biology by providing the capability to assess gene expression pattern within a single cell. Our method isolates and separately barcodes mRNAs from thousands of single cells and sequences their expressomes. Understanding regenerative processes on a molecular level would not only help reduce long-term spaceflight impact on health, but also may enable the development of novel tissue regenerative approaches to tissue degeneration on Earth.

Single cell sequencing↗

Method Development for Multiplex, In-Situ, and Real-Time Detection of Herpesvirus Reactivation in Spaceflight Crews using Nanopore Sequencing

Reactivation of latent herpesviruses in crews onboard the International Space Station (ISS) is a well-established spaceflight-associated phenomenon and has been linked to overall immune stress. Beyond an indicator of an altered immune state, this stress-induced reactivation of viruses such as herpesvirus simplex virus 1 (HSV-1), Epstein-Barr virus (EBV), and Varicella-Zoster virus (VZV) may cause clinical symptoms in crew. There is currently no established protocol for in-flight monitoring, and samples are analyzed post-flight using ground-based assays. A real-time, in-flight method for herpesvirus detection followed by stress-mitigation strategies would be a significant advance. In this study, we developed a real-time assay for the multiplex detection of HSV-1, EBV, and VZV from saliva that could be implemented for in-situ monitoring of ISS crew. This method builds on previously validated spaceflight-compatible portable molecular protocols and platforms, such as the miniPCR thermal cycler and the MinION sequencer. Since a metagenomic approach is not currently permitted for crew samples (NASA policy), we employed multiplexing-ready primers directed toward targeted regions within the HSV-1, EBV, and VZV genomes. We also used primers for the human gene, Statherin (STATH), as an internal control. These primers were validated using spiked-in, positive control HSV-1, EBV, and VZV from virus-negative saliva extracted using the Zymo-Research Quick-DNA/RNA Viral MagBead Kit. The PCR Barcoding Kit was used to prepare DNA libraries that were then sequenced on the MK1C and analyzed against known reference genomes using minimap2. Following validation of this method with spiked saliva samples, suspected herpesvirus-positive clinical saliva samples were successfully tested. Prior to use onboard the ISS, this method will be deployed to an analog environment during overwintering at Palmer Station, Antarctica in 2023. This work represents the successful application of molecular technologies currently onboard the ISS for the real-time monitoring of latent herpesvirus reactivation from saliva samples. This assay, in combination with stress-reduction strategies, holds the potential to manage herpesvirus reactivation in ISS crew, thereby improving health outcomes and overall immunity.

Patrick M. Rydzak↗