Search NASASearch

SEARCH · Search NASA

Results for “Baseline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Using Visual Systems Mapping to Improve Transparency and Comparability of Life Cycle Assessment Baseline Scenarios

Visual systems mapping is a systems engineering approach used to represent complex processes and interactions. This study evaluates its application for documenting assumptions in life cycle assessment (LCA) baseline scenarios. In LCA, the baseline or reference case represents the business as usual system against which changes in impacts (e.g., emissions) are assessed. These baseline assumptions are particularly influential in biomass LCAs, yet they often vary across studies due to regional context, system boundaries, and simplifying assumptions that are not consistently or transparently documented. As a result, key feedbacks, omitted processes, and boundary choices may remain unclear, limiting comparability across studies and weakening their usefulness for decision-making. This study examines whether visual systems mapping can improve the transparency and comparability of biomass LCA baseline scenarios. A case study of five published biomass-related LCAs were reviewed, and their baseline scenarios were translated into visual system maps to identify included processes, omitted components, and underlying assumptions. The analysis demonstrates that visual systems mapping can make baseline assumptions more explicit, highlight excluded dynamics, and improve documentation of system boundaries. Based on these findings, the study recommends the use of visual systems mapping alongside open data repositories and reproducible workflows to support greater transparency, reproducibility, and comparability in LCAs. These improvements can strengthen the role of LCAs in informing decisions related to sustainable biomass systems.

Davis, Maggie [ORNL] (ORCID:0000000181319328)

Western Interconnection Baseline Study

The purpose of the baseline study is to evaluate the degree to which current industry planning processes meet the national 2035 decarbonization goals for the Western Interconnection. This analysis serves as a comparative baseline for the scenario analysis conducted in the NTP Study using a Western Interconnection dataset that is readily available to industry. This baseline analysis differs from the production cost modeling analysis and power flow analysis in the main NTP Study report (forthcoming). In particular, the analysis presented in this report reflects a business-as-usual future with an optimistic build out of specific planned transmission projects and foreseeable generation. In contrast, the NTP Study models a future generation and transmission expansion based on optimization from a capacity expansion model. The analysis presented herein also reflects a 2030 timeframe, whereas the main NTP Study production cost modeling analysis and power flow analysis reflect a 2035 time frame. This baseline analysis utilizes industry’s most reliable data to account for future transmission projects across various stages of development, with a particular focus on those in the permitting stage. Additionally, it incorporates projections for changes in generation capacity (both additions and retirements). This baseline analysis outlines a probable trajectory, given current process and practice, for the future of the bulk power system with a horizon extending to 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Baseline Graphite Characterization

Baseline Graphite Characterization: Purpose of Baseline, Mechanical Baseline Tests, Physical Properties Tests, Methodology, Baseline progress, Density, Ultimate Tensile Strength, PCEA Ultimate Tensile Strength, Split Disc Tests, Compression Tests, Flexural Tests, and Coefficient of Thermal Expansion.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Neutrino oscillation prospects with a dual-baseline beam from BNL to SNOLAB and SURF

The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW fraction of the EIC proton beam to generate a high-intensity GeV-scale neutrino beam for long-baseline oscillation studies. We have simulated proton-target interactions and optimize the resulting neutrino fluxes for water-based liquid scintillator (WbLS) detectors located at distinct baselines of 900 km and at 2900 km. Oscillation analyses performed with GLoBES show that extended baselines allow access to multiple oscillation maxima, significantly enhancing sensitivity to leptonic CP violation. The study also examines the interplay between matter effects and the intrinsic CP violating phase in shaping observable asymmetries. We note that simplified systematics and no backgrounds are used in this analysis to establish the baseline physics potential. These results suggest that the EIC proton beam could provide a novel and complementary source for precision neutrino physics, extending the scientific reach of the EIC program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Terrestrial Very-Long-Baseline Atom Interferometry: summary of the second workshop

This summary of the second Terrestrial Very-Long-Baseline Atom Interferometry (TVLBAI) Workshop provides a comprehensive overview of our meeting held in London in April 2024 (Second Terrestrial Very-Long-Baseline Atom Interferometry Workshop, Imperial College, April 2024), building on the initial discussions during the inaugural workshop held at CERN in March 2023 (First Terrestrial Very-Long-Baseline Atom Interferometry Workshop, CERN, March 2023). Like the summary of the first workshop (Abend et al. in AVS Quantum Sci. 6:024701, 2024), this document records a critical milestone for the international atom interferometry community. It documents our concerted efforts to evaluate progress, address emerging challenges, and refine strategic directions for future large-scale atom interferometry projects. Our commitment to collaboration is manifested by the integration of diverse expertise and the coordination of international resources, all aimed at advancing the frontiers of atom interferometry physics and technology, as set out in a Memorandum of Understanding signed by over 50 institutions (Memorandum of Understanding for the Terrestrial Very Long Baseline Atom Interferometer Study).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Examination of 3013 Containers Baseline Surface Features

The Surveillance and Monitoring Program at Los Alamos National Laboratory (LANL) was tasked with evaluating the baseline features of 3013 containers. This baseline is to be used as a basis for comparison for 3013 containers that had been packaged with corrosive plutonium materials. The LANL team evaluated an unwelded container, an unused welded container, and a welded container that had held plutonium metal without any corrosive impurities. These three containers had features with depths no larger than 6 µm and had similar depth distributions. The features observed in the baseline containers were all shallower than those seen in containers packaged with corrosive plutonium materials. This work establishes workflows for feature identification and measurement, as well as establishment of baseline data for future comparison with corroded containers.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Near Detector Selection for Neutral Current Disappearance Search at the Short-Baseline Neutrino Program

Various short baseline neutrino experiments observe anomalies that challenge the three-flavor neutrino oscillation model, consistent with a hypothetical “sterile” neutrino that does not interact via the weak force. This poster presents a near detector event selection at the Short-Baseline Near Detector (SBND), developed for the first search for neutral current (NC) disappearance at short-baseline experiments. NC disappearance provides ``smoking gun” insight into the sterile neutrino question because NC interactions are equally sensitive to all three active neutrinos, meaning any change in the NC interaction rate between near and far detectors cannot be explained by oscillations among known flavor states. This analysis focuses on the NC1p topology, the most common NC interaction type at the Short-Baseline Neutrino (SBN) Program. NC topologies are inherently challenging due to their low light yield and the absence of an outgoing charged lepton, which complicates identification and leads to poor energy reconstruction as the outgoing neutrino carries away a large portion of the neutrino’s initial energy. This work presents an NC1p event selection at the near detector, highlighting SBND’s impressive detector capabilities, including trigger efficiency studies. Combined with a novel kinematic energy reconstruction technique leveraging the detector’s outstanding hadronic detail, this analysis establishes a robust near detector foundation to target an NC disappearance measurement consistent with the 3$+$1 sterile neutrino model. This SBND selection will soon be combined with the far detector to conduct an NC disappearance search, providing unique insight and complementary information to traditional charged current searches and advancing the SBN Program’s goal to resolve the sterile neutrino question, including 3$+$1 searches and beyond.

Nicole Pallat, Nicole Pallat [Minnesota U.] (ORCID

First Very Long Baseline Interferometry Detections at 870μm

The first very long baseline interferometry (VLBI) detections at 870$\mu$m wavelength (345$\,$GHz frequency) are reported, achieving the highest diffraction-limited angular resolution yet obtained from the surface of the Earth, and the highest-frequency example of the VLBI technique to date. These include strong detections for multiple sources observed on inter-continental baselines between telescopes in Chile, Hawaii, and Spain, obtained during observations in October 2018. The longest-baseline detections approach 11$\,$G$\lambda$ corresponding to an angular resolution, or fringe spacing, of 19$\mu$as. The Allan deviation of the visibility phase at 870$\mu$m is comparable to that at 1.3$\,$mm on the relevant integration time scales between 2 and 100$\,$s. The detections confirm that the sensitivity and signal chain stability of stations in the Event Horizon Telescope (EHT) array are suitable for VLBI observations at 870$\mu$m. Operation at this short wavelength, combined with anticipated enhancements of the EHT, will lead to a unique high angular resolution instrument for black hole studies, capable of resolving the event horizons of supermassive black holes in both space and time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

ROADRUNNER uranium nitride MiniFuel: Experimental design, fabrication and pre-irradiation baseline characterization for accelerated burnup testing

Uranium nitride (UN) is a promising fuel candidate for advanced reactor systems owing to its high uranium density and thermal conductivity; however, its qualification remains constrained by the scarcity of well-controlled irradiation performance data. Here, to address this limitation, the ROADRUNNER (Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments) campaign employs the MiniFuel platform in the High Flux Isotope Reactor (HFIR) to enable accelerated burnup irradiation testing under tightly controlled and largely isothermal conditions. This paper presents the experimental design, fuel fabrication, and pre-irradiation baseline characterization of the ROADRUNNER UN MiniFuel campaign. Thirty-six UN minidisc specimens were fabricated with systematically varied as-fabricated density (86–96% of theoretical density), carbon impurity content (961–5240 ppm), oxygen content (≤ ∼2000 ppm), and grain size (2.5–24 μm). The irradiation matrix spans nominal fuel temperatures of 873 K, 1173 K, and 1473 K and target burnups of 3.75%, 6.0%, and 7.5% fissions per initial metal atom (FIMA). Neutronic and thermal analyses were performed to define specimen-specific burnup accumulation and temperature histories, establishing the boundary conditions for subsequent in-pile behavior. Comprehensive pre-irradiation characterization—including dimensional metrology, density verification, impurity analysis, X-ray diffraction, Raman spectroscopy, scanning electron microscopy, X-ray computed tomography, and confocal profilometry—provides a detailed baseline for post-irradiation examination. Pre-irradiation data were further used to generate predictive estimates of fission gas release and swelling using existing empirical correlations. This quantitative comparison reveals substantial inter-model divergence at intermediate and elevated temperatures that exceeds propagated input uncertainties, highlighting structural gaps in the historical irradiation database. The ROADRUNNER irradiation campaign is currently underway in HFIR, with initial firs cycle completed in late 2025 and remaining targets scheduled through 2027. The experimental design and baseline dataset presented here establish the framework needed to interpret forthcoming post-irradiation measurements and to provide discriminating data for the validation and refinement of physics-based UN fuel performance models.

Lopes, Denise Adorno [Oak Ridge National Laborator

Weak baselines and reporting biases lead to overoptimism in machine learning for fluid-related partial differential equations

One of the most promising applications of machine learning in computational physics is to accelerate the solution of partial differential equations (PDEs). The key objective of machine-learning-based PDE solvers is to output a sufficiently accurate solution faster than standard numerical methods, which are used as a baseline comparison. Here, we first perform a systematic review of the ML-for-PDE-solving literature. Out of all of the articles that report using ML to solve a fluid-related PDE and claim to outperform a standard numerical method, we determine that 79% (60/76) make a comparison with a weak baseline. Second, we find evidence that reporting biases are widespread, especially outcome reporting and publication biases. We conclude that ML-for-PDE-solving research is overoptimistic: weak baselines lead to overly positive results, while reporting biases lead to under-reporting of negative results. To a large extent, these issues seem to be caused by factors similar to those of past reproducibility crises: researcher degrees of freedom and a bias towards positive results. We call for bottom-up cultural changes to minimize biased reporting as well as top-down structural reforms to reduce perverse incentives for doing so.

97 MATHEMATICS AND COMPUTING

ICARUS at the Short-Baseline Neutrino program: first results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous $\nu_e$ appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 $eV^2$. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operation collecting the first neutrino events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this presentation, preliminary results from the ICARUS data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

Artero Pons, Maria

3013 Baseline Inner Container Report: Description, Imaging, and Analysis

This report presents consolidated findings from three microscopy studies of baseline Bagless Transfer Containers (BTCs), which are the inner containers used in DOE Standard 3013-compliant plutonium storage packages. The studies were conducted by Los Alamos National Laboratory (LANL), Savannah River National Laboratory (SRNL), and DNV, a subcontractor specializing in corrosion science. The baseline BTCs examined had not been exposed to corrosive environments, serving as control samples for comparison with destructively examined (DE) containers. Additionally, the Background section provides an overview of the BTC design, including manufacturing methods, material properties, and container configurations that may influence corrosion behavior. The primary objective of the LANL and SRNL studies was to establish reference characteristics of BTCs to distinguish manufacturing artifacts from corrosion-induced features observed in DE containers. Both laboratories used advanced microscopy techniques, including Wide Area Microscopy (WAMS), Laser Confocal Microscopy (LCM), Scanning Electron Microscopy (SEM), and Focused Ion Beam (FIB), to reveal that most surface anomalies were shallow and attributable to flow-forming processes, not corrosion. Subsurface impurities, identified as non-metallic inclusions, were also observed. DNV’s investigation focused on characterizing the mechanical and chemical properties of the BTC material to support crack growth modeling. Their findings indicate higher hardness and strength but reduced ductility—consistent with flow-formed 304L stainless steel and a higher-than-expected martensite content, in contrast to manufacturer claims. Ongoing and future studies, including Electron Backscatter Diffraction (EBSD), aim to further understand the microstructural factors influencing crack initiation and propagation. The combined studies provide a crucial baseline for distinguishing corrosion effects in DE containers, contributing to the safe and reliable long-term storage of plutonium-bearing materials.

36 MATERIALS SCIENCE

Latest Results from the ICARUS Experiment at the Short-Baseline Neutrino Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). To date, ICARUS has accumulated approximately 5.2\times 10^{20} protons on target (POT) with the BNB and about 6.2\times 10^{20} POT with NuMI. Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Hausner, Harry [Fermilab]

Latest Results from the ICARUS experiment at the Short-Baseline Neutrino Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Farnese, Christian [Fermilab]

ICARUS at the Short-Baseline Neutrino Program: First Results

The ICARUS collaboration employed the 760-ton T600 detector in a successful three-year physics run at the underground LNGS laboratory. In 2021, ICARUS started its new operation at Fermilab, collecting a substantial amount of neutrino events from the Booster Neutrino Beam (BNB) and the neutrinos at the Main Injector (NuMI) beam off-axis. These were used to test the ICARUS event selection, reconstruction, and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022, moving then to data taking for neutrino oscillation physics, aiming at first to either confirm or refute the claim by the Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurements of neutrino cross sections in LAr with the NuMI beam and several Beyond Standard Model studies. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this work, preliminary results from the ICARUS data with the BNB and NuMI beams are presented, both in terms of the performance of all ICARUS subsystems and the capability to select and reconstruct neutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]