Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bayesian Model Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fast matrix algebra for Bayesian model calibration

In Bayesian model calibration, evaluation of the likelihood function usually involves finding the inverse and determinant of a covariance matrix. When Markov Chain Monte Carlo (MCMC) methods are used to sample from the posterior, hundreds of thousands of likelihood evaluations may be required. In this paper, we demonstrate that the structure of the covariance matrix can be exploited, leading to substantial time savings in practice. Here, we also derive two simple equations for approximating the inverse of the covariance matrix in this setting, which can be computed in near-quadratic time. The practical implications of these strategies are demonstrated using a simple numerical case study and the "quack" R package. For a covariance matrix with 1000 rows, application of these strategies for a million likelihood evaluations leads to a speedup of roughly 4000 compared to the naive implementation

97 MATHEMATICS AND COMPUTING↗

Quantifying uncertainty in analysis of shockless dynamic compression experiments on platinum. II. Bayesian model calibration

Dynamic shockless compression experiments provide the ability to explore material behavior at extreme pressures but relatively low temperatures. Typically, the data from these types of experiments are interpreted through an analytic method called Lagrangian analysis. Here, in this work, alternative analysis methods are explored using modern statistical methods. Specifically, Bayesian model calibration is applied to a new set of platinum data shocklessly compressed to 570 GPa. Several platinum equation-of-state models are evaluated, including traditional parametric forms as well as a novel non-parametric model concept. The results are compared to those in Paper I obtained by inverse Lagrangian analysis. The comparisons suggest that Bayesian calibration is not only a viable framework for precise quantification of the compression path, but also reveals insights pertaining to trade-offs surrounding model form selection, sensitivities of the relevant experimental uncertainties, and assumptions and limitations within Lagrangian analysis. The non-parametric model method, in particular, is found to give precise unbiased results and is expected to be useful over a wide range of applications. The calibration results in estimates of the platinum principal isentrope over the full range of experimental pressures to a standard error of 1.6%, which extends the results from Paper I while maintaining the high precision required for the platinum pressure standard.

Brown, Justin Lee↗

An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars

The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser-induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so-called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two-element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.

97 MATHEMATICS AND COMPUTING↗

Elastic Bayesian Model Calibration

Functional data are ubiquitous in scientific modeling. For instance, quantities of interest are modeled as functions of time, space, energy, density, etc. Uncertainty quantification methods for computer models with functional response have resulted in tools for emulation, sensitivity analysis, and calibration that are widely used. However, many of these tools do not perform well when the computer model’s parameters control both the amplitude variation of the functional output and its alignment (or phase variation). This paper introduces a framework for Bayesian model calibration when the model responses are misaligned functional data. The approach generates two types of data out of the misaligned functional responses: (1) aligned functions so that the amplitude variation is isolated and (2) warping functions that isolate the phase variation. These two types of data are created for the computer simulation data (both of which may be emulated) and the experimental data. The calibration approach uses both types so that it seeks to match both the amplitude and phase of the experimental data. The framework is careful to respect constraints that arise, especially when modeling phase variation, and is framed in a way that it can be done with readily available calibration software. In conclusion, we demonstrate the techniques on two simulated data examples and on two dynamic material science problems: a strength model calibration using flyer plate experiments and an equation of state model calibration using experiments performed on the Sandia National Laboratories’ Z-machine.

97 MATHEMATICS AND COMPUTING↗

Robust Importance Sampling for Bayesian Model Calibration with Spatio-Temporal Data

This paper addresses two challenges in Bayesian calibration: 1) computational speed of existing sampling algorithms, and 2) calibration with spatio-temporal responses. The commonly used Markov Chain Monte Carlo (MCMC) approaches require many sequential model evaluations making the computational expense prohibitive. This paper proposes an efficient sampling algorithm: iterative importance sampling with genetic algorithm (IISGA). While iterative importance sampling enables computational efficiency, the genetic algorithm enables robustness by preventing sample degeneration and avoids getting stuck in multimodal search spaces. An inflated likelihood further enables robustness in high-dimensional parameter spaces by enlarging the target distribution. Spatio-temporal data complicate both surrogate modeling, which is necessary for expensive computational models, and the likelihood estimation. In this work, singular value decomposition is investigated for reducing the high-dimensional field data to a lower-dimensional space prior to Bayesian calibration. Then the likelihood is formulated and Bayesian inference is performed in the lower-dimension, latent space. An illustrative example is provided to demonstrate IISGA relative to existing sampling methods, and then IISGA is employed to calibrate a thermal battery model with 26 uncertain calibration parameters and spatio-temporal response data.

97 MATHEMATICS AND COMPUTING↗

Massively Parallel Bayesian Model Calibration and Uncertainty Quantification with Applications to Nuclear Fuels and Materials

The U.S. Department of Energy (DOE)’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program aims to develop predictive capabilities by applying computational methods to the analysis and design of advanced reactor and fuel cycle systems. This program has been providing engineering-scale support for the development of BISON, a high-fidelity and high-resolution fuel performance tool. Fuel behavior in a nuclear reactor is governed by a complex network of mechanisms interacting with various other physics aspects in the reactor system. Any model developed to represent the fuel behavior will likely be idealized resulting in uncertainties in their predictions compared to the observed data. As such, this report was motivated by the need to identify the sources of uncertainties and quantify and propagate them through the fuel model outputs. Such quantification of uncertainties will establish a level of model trustworthiness, identify approaches to improve the model trustworthiness, and even guide optimal experiment design for maximal information gain. To accomplish the uncertainty quantification for computational models, this report has relied on the Bayesian framework which provides probabilistic treatment of models their inputs and outputs. The current state-of-the-art on performing Bayesian Uncertainty Quantification (UQ) for nuclear engineering models using High Performance Computing (HPC) resources have been reviewed. Implementation of capabilities for massively parallel Bayesian UQ in Multiphysics Object-Oriented Simulation Environment (MOOSE) is discussed. Several verification cases are discussed to verify the accuracy of the quantified uncertainties using the developed computational capabilities in MOOSE. Then, the problem of quantifying the uncertainties in TRI-Structural isOtropic (TRISO) fuel silver release is addressed. For the first time, the uncertainties arising from the TRISO Fission Gas Release (FGR) model due to model inadequacy and experimental noise are quantified. Also, the Bayesian capabilities are applied to the calibration of the MATPRO creep model, a widely used model in several fuel assessment cases. The impact of the prediction uncertainties in the MATPRO model on the fuel cladding behavior as part of the TRIBULATION assessment case (which is an integral effects case) is investigated. This report concludes with a discussion on the future work for the UQ for computational models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dealing with Measurement Uncertainties as Nuisance Parameters in Bayesian Model Calibration

In the presence of model discrepancy, the calibration of physics-based models for physical parameter inference is a challenging problem. Lack of identifiability between calibration parameters and model discrepancy requires additional identifiability constraints to be placed on the model discrepancy to obtain unique physical parameter estimates. If these assumptions are violated, the inference for the calibration parameters can be systematically biased. In many applications, such as in dynamic material property experiments, many of the calibration inputs refer to measurement uncertainties. Here, we develop a metric for identifying overfitting of these measurement uncertainties, propose a prior capable of reducing this overfitting, and show how this leads to a diagnostic tool for validation of physical parameter inference. The approach is demonstrated for a benchmark example and applied for a material property application to perform inference on the equation of state parameters of tantalum.

97 MATHEMATICS AND COMPUTING↗

EFBMC

SAND2026-23986O EFBMC performs elastic Bayesian model calibration by applying Bayesian statistics and functional analysis. The software provides Python, R, and MATLAB scripts that enable users to calibrate models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tucker, J. Derek [Sandia National Lab. (SNL-CA), L↗

Quantification of modeling uncertainty in the Rayleigh damping model

Understanding and accurately characterizing energy dissipation mechanisms in civil structures during earthquakes is an important element of seismic assessment and design. The most commonly used model is attributed to Rayleigh. This paper proposes a systematic approach to quantify the uncertainty associated with Rayleigh's damping model. Bayesian calibration with embedded model error is employed to treat the coefficients of the Rayleigh model as random variables using modal damping ratios. Through a numerical example, we illustrate how this approach works and how the calibrated model can address modeling uncertainty associated with the Rayleigh damping model.

42 ENGINEERING↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

Goal-oriented a-posteriori estimation of model error as an aid to parameter estimation

In this work, a Bayesian model calibration framework is presented that utilizes goal-oriented a-posterior error estimates in quantities of interest (QoIs) for classes of high-fidelity models characterized by PDEs. It is shown that for a large class of computational models, it is possible to develop a computationally inexpensive procedure for calibrating parameters of high-fidelity models of physical events when the parameters of low-fidelity (surrogate) models are known with acceptable accuracy. The main ingredients in the proposed model calibration scheme are goal-oriented a-posteriori estimates of error in QoIs computed using a so-called lower fidelity model compared to those of an uncalibrated higher fidelity model. The estimates of error in QoIs are used to define likelihood functions in Bayesian inversion analysis. A standard Bayesian approach is employed to compute the posterior distribution of model parameters of high-fidelity models. As applications, parameters in a quasi-linear second-order elliptic boundary-value problem (BVP) are calibrated using a second-order linear elliptic BVP. In a second application, parameters of a tumor growth model involving nonlinear time-dependent PDEs are calibrated using a lower fidelity linear tumor growth model with known parameter values.

A-posterior estimates↗

Robust scalable initialization for Bayesian variational inference with multi-modal Laplace approximations

Predictive modeling typically relies on Bayesian model calibration to provide uncertainty quantification. Variational inference utilizing fully independent (“mean-field”) Gaussian distributions are often used as approximate probability density functions. This simplification is attractive since the number of variational parameters grows only linearly with the number of unknown model parameters. However, the resulting diagonal covariance structure and unimodal behavior can be too restrictive to provide useful approximations of intractable Bayesian posteriors that exhibit highly non-Gaussian behavior, including multimodality. High-fidelity surrogate posteriors for these problems can be obtained by considering the family of Gaussian mixtures. Gaussian mixtures are capable of capturing multiple modes and approximating any distribution to an arbitrary degree of accuracy, while maintaining some analytical tractability. Unfortunately, variational inference using Gaussian mixtures with full-covariance structures suffers from a quadratic growth in variational parameters with the number of model parameters. The existence of multiple local minima due to strong nonconvex trends in the loss functions often associated with variational inference present additional complications, These challenges motivate the need for robust initialization procedures to improve the performance and computational scalability of variational inference with mixture models. In this work, we propose a method for constructing an initial Gaussian mixture model approximation that can be used to warm-start the iterative solvers for variational inference. The procedure begins with a global optimization stage in model parameter space. In this step, local gradient-based optimization, globalized through multistart, is used to determine a set of local maxima, which we take to approximate the mixture component centers. Around each mode, a local Gaussian approximation is constructed via the Laplace approximation. Finally, the mixture weights are determined through constrained least squares regression. The robustness and scalability of the proposed methodology is demonstrated through application to an ensemble of synthetic tests using high-dimensional, multimodal probability density functions. Here, the practical aspects of the approach are demonstrated with inversion problems in structural dynamics.

97 MATHEMATICS AND COMPUTING↗

A hierarchical Bayesian model for background variation in radiation source localization

In this paper, we apply a new model to account for varying background radiation in radiological source localization. We present a hierarchical Bayesian model that simultaneously infers background and source location parameters without requiring separate estimation of the background radiation at each detector location. We employ a simplified photon transport model to reduce the computational expense of Bayesian model calibration. Furthermore, we demonstrate the model accuracy by localizing a cesium-137 source in a simulated city block, and we analyze experimental field measurements with varying background. In both cases, the model provides sufficient fidelity that we can locate the source while simultaneously estimating background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗