Search NASA⌕ Search

SEARCH · Search NASA

Results for “BeRP Ball”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Benchmark Measurements of the BeRP Ball in Various Reflectors

Details of benchmark neutron multiplicity measurements of the 4.484 kg Beryllium Reflected Plutonium (BeRP) ball inside of various reflectors. Measurements were performed with an Ortec Fission Meter neutron multiplicity counter. Measurements were made of the bare BeRP Ball, the BeRP Ball inside 3 inch thick polyethylene, nickel, and tungsten, and the polyethylene with an additional 2 inch thick steel reflector. For every measurement, the mass m S of 240 Pu, k eff , multiplication M, and escape multiplication ME are reported. For each individual measurement, the measured mass mS of 240 Pu in the BeRP Ball was within 20.7 grams (closest edge of measurement errorbar to closest edge of errorbar for reference mS from isotopics). The combined measurement of the mass of 240 Pu m S = 267 ± 7 grams which compared very favorably to the known value from isotopics of m S = 266.8 ± 0.5 grams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 203 CED-2 Report: LLNL Final Design for BERP Ball With a Composite Reflector of Thin Polyethylene Backed by Nickel

This report documents the results of final design (CED-2) for IER 203, BERP Ball Composite Reflection, and focuses on critical configurations with a 4.5 kg α-phase plutonium sphere reflected by a combination of thin high-density polyethylene (HDPE) backed by a thick nickel reflector. The Lawrence Livermore National Laboratory’s (LLNL’s) Nuclear Criticality Safety Division, in support of fissile material operations, calculated surprisingly reactive configurations when a fissile core was surrounded by a thin, moderating reflector backed by a thick metal reflector. These composite reflector configurations were much more reactive than either of the single reflector materials separately. The calculated findings have resulted in a stricter-than-anticipated criticality control set, impacting programmatic work. IER 203 was requested in response to these seemingly anomalous calculations to see if the composite reflection effect could be shown experimentally. This report focuses on the Beryllium Reflected Plutonium (BERP) ball as a fissile material core reflected by polyethylene and nickel. A total of four critical configurations were designed as part of CED-2. Fabrication costs are estimated to be $98,500, largely due to the cost of the large nickel reflectors. The IER 203 experiments could reasonably be expected to begin in early FY2017.

42 ENGINEERING↗

Subcritical Benchmark of the BeRP Ball Reflected by Tungsten

In September 2012, eight subcritical configurations were measured with the clad a-phase plutonium sphere known as the Beryllium-Reflected Plutonium (BeRP) ball at the National Criticality Experiments Research Center (NCERC). The configurations had varying tungsten thicknesses including: 0 (bare), 0.5, 1.0, 1.5, 2.0, 2.5, 2.75, and 3.0 inches. Measurements were conducted to provide subcritical benchmark data. This work includes measured and simulated results from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP) evaluation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Review Report for the Model 9977 Safety Analysis Report for Packaging Addendum 1 Justification for DNDO Contents

The Model 9977 Package is currently certified for Content Envelope C.1, {sup 238}Pu Heat Sources, either in Radioisotope Thermoelectric Generator (RTG), or in Food-Pack Can configurations, under Certificate of Compliance (CoC) Certificate Number 9977 and Package Identification Number USA/9977/B(M)F-96 (DOE). Addendum 1, Justification for DNDO Contents,--the Submittal--supplements Revision 2 of the Safety Analysis Report for Packaging for the Model 9977 Package. The Submittal adds five new contents to the Model 9977 Package, Content Envelopes, AC.1 through AC.5. The Content Envelopes are neptunium metal, the beryllium-reflected plutonium ball (BeRP Ball), plutonium/uranium metal, plutonium/uranium metal with enhanced wt% {sup 240}Pu (to 50 wt%), and uranium metal. The last three Content Envelopes are stabilized to DOE-STD-3013. These Content Envelopes will be shipped to the Device Assembly Facility (DAF) at the Nevada Test Site (NTS), where they will reside, and, hence, to off-site locations in support of the Department of Homeland Security (DHS) Domestic Nuclear Detection Office (DNDO). The new certificate will apply to a limited number of Model 9977 Packages. At the same time, the Submittal requests an extension of the periodic maintenance requirements from one (1) year to up to five (5) years using Radio-Frequency Identification (RFID) temperature-monitoring systems to measure the ambient storage temperature in order to ensure that the temperature of the Viton{reg_sign} O-rings for the 6-inch Containment Vessel (6CV) remain less than 200 F. The RFIDs have been developed by Argonne National Laboratory. An on-going surveillance program at the K-Area Materials Storage (KAMS) facility at the Savannah River Site, and an on-going examination of Viton{reg_sign} O-rings from mock Primary Containment Vessels (PCVs) at Savannah River National Laboratory (SRNL) provide the technical justification for the extension of the periodic maintenance interval. Where extended periodic maintenance is desired, the decay heat rate for the Model 9977 Package is limited to 15 watts.

99 GENERAL AND MISCELLANEOUS↗

Using MCNP6 to Estimate Fission Neutron Properties of a Reflected Plutonium Sphere

The purpose of this project was to determine the fission multiplicity distribution, p(v), for the Beryllium Reflected Plutonium (BeRP) ball and to determine whether or not it changed appreciably for various High Density Polyethylene (HDPE) reflected configurations. The motivation for this project was to determine whether or not the average number of neutrons emitted per fission, v, changed significantly enough to reduce the discrepancy between MCNP6 and Robba, Dowdy, Atwater (RDA) point kinetic model estimates of multiplication. The energy spectrum of neutrons that induced fissions in the BeRP ball, NIF (E), was also computed in order to determine the average energy of neutrons inducing fissions, NIF . p(v) was computed using the FMULT card, NIF (E) and NIF were computed using an F4 tally with an FM tally modifier (F4/FM) card, and the multiplication factor, k eff , was computed using the KCODE card. Although NIF (E) changed significantly between bare and HDPE reflected configurations of the BeRP ball, the change in p(v), and thus the change in v, was insignificant. This is likely due to a difference between the way that NIF is computed using the FMULT and F4/FM cards. The F4/FM card indicated that NIF (E) was essentially Watt-fission distributed for a bare configuration and highly thermalized for all HDPE reflected configurations, while the FMULT card returned an average energy between 1 and 2 MeV for all configurations, which would indicate that the spectrum is Watt-fission distributed, regardless of the amount of HDPE reflector. The spectrum computed with the F4/FM cards is more physically meaningful and so the discrepancy between it and the FMULT card result is being investigated. It is hoped that resolving the discrepancy between the FMULT and F4/FM card estimates of NIF(E) will provide better v estimates that will lead to RDA multiplication estimates that are in better agreement with MCNP6 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Neutron Multiplicity Counting Experiments to Optimal Cross-Section Adjustments

This paper presents the first application of model calibration to neutron multiplicity counting (NMC) experiments for cross-section optimization that is informed by adjoint-based sensitivity analysis (SA) and first-order uncertainty quantification (UQ). We summarize previous work on SA applied to NMC and describe notable modifications and additions. We give the procedure for first-order UQ and Bayesian-inference-based parameter estimation (PE). We then discuss model calibration applied to NMC of a 4.5-kg sphere of weapons-grade, alpha-phase plutonium metal (the BeRP ball) with the nPod neutron multiplicity counter. For the BeRP ball in bare and polyethylene-reflected configurations, we discuss the sensitivity of the first- and second-moment detector responses (i.e., first and second moments of the NMC distribution, respectively) to the cross sections. We describe the sources of uncertainty in the measured and simulated responses. Specifically, uncertainty in the measured responses is due to both random and systematic sources. Uncertainty in the simulated responses is due to the cross-section covariances. We describe in detail the adjustment to the cross sections and cross-section covariances due to the optimization. Due to the contribution of systematic uncertainties to the measured response uncertainties, the adjustment to the cross sections is similar in trend but larger in magnitude compared to that recommended by previous work. We compare the measured responses to responses simulated with nominal and optimized cross sections, demonstrating that the best-estimate cross sections produce simulations of NMC experiments that are more accurate with reduced uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed Plutonium-Nickel Critical Experiment

The Los Alamos Critical Experiments Facility (LACEF) and subsequently its descendant, the National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site, have been performing critical experiments for over 75 years. The work done continues to build upon lessons learned from the past. It also builds upon knowledge gained from past experiments. The LACEF and NCERC experiments “provide nuclear criticality benchmark data for a wide variety of fissile and non-fissile materials in all neutron energy spectra systems”. In 2014, a subcritical benchmark with plutonium surrounded by nickel was issued in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Two years later, a new benchmark experiment was performed, commonly known as Subcritical Copper Reflected $\mathcal{a}$-Phase Plutonium SCR$\mathcal{a}$P. The uncertainties in the SCR$\mathcal{a}$P experiment were significantly reduced from the Pu-Ni experiment and the methods were refined. Additionally, a Pu-lead critical experiment was performed in 2017 which followed different methods and with different objectives. Now, an experiment is proposed that builds on both the subcritical nickel experiment and the critical lead experiment. The proposed experiment has interleaved nickel and plutonium, in a thermal arrangement. This particular experiment would support criticality safety at the Hanford Tank Farms, whose tanks contain a significant amount of nickel credited as a neutron absorber in the criticality safety evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thoughts on Uncertainties in the Moments Formalism of the Statistical Theory of Fission Chains

A LANL paper says it provides an uncertainty analysis of subcritical benchmark measurements using the Hage-Cifarelli moment’s formalism. The goal of the LANL work is to provide uncertainties in the leakage and total multiplication values for use in subcritical benchmark measurements. Data of the bare BeRP ball taken September 17-20 2012 as part of exper iment IER-161 for the Department of Energy Nuclear Criticality Safety Program are used as an example to determine the measured uncertainties in leakage and total multiplication. The contribution of each parameter to the total uncertainty is then examined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the NPOD3 Detectors in MCNP5 and MCNP6

Researchers performed a series of measurements in May 2012 to characterize the NPOD3 detector systems. The detectors were placed in varying states of disassembly to determine the effect of individual components on detection efficiency. A 4.5 kg α-phase Pu sphere known as the Los Alamos BeRP Ball was used as the SNM source in both a bare configuration and reflected by varying thicknesses of polyethylene. A set of simulations matching the experimental setups were run and the data were compared to the measured data. The total and leakage multiplication and the inferred k values were determined for both the simulations and the measurements. Table 3 shows a comparison of the results from MCNP6 and MCNP5 with the list-mode patch to the measured results. The count rates for the calculated results were obtained by dividing the total line count in the list-mode file (equivalent to the total number of absorptions in the NPOD detectors) by the total run time. The count rates are identical for both codes, and they both produce the same multiplicity and inferred k values regardless of measurement time as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(U) Feynman-Y calculations using PARTISN

A prescription for computing the Feynman Y as a function of coincidence gate width using a deterministic multigroup neutron transport code has been published and the results compared favorably with measurements of the BeRP ball. In this paper, we report on our project to implement the method and reproduce the results. There are several clarifications and corrections of the published prescription. We show results using two multigroup cross section libraries compared with measurements and with Monte Carlo results. Deterministic simulations of the mean count rates compare very favorably with previously published Monte Carlo results, and deterministic simulations of the Feynman Y asymptote compare somewhat favorably. In Feynman beta plots, the deterministic simulations reached the asymptotic value much sooner than did a fit to the measured data.

42 ENGINEERING↗

Utilization of the Differential Die-Away Self-Interrogation Technique for Characterization and Verification of Spent Nuclear Fuel

New nondestructive assay techniques are sought to better characterize spent nuclear fuel. One of the NDA instruments selected for possible deployment is differential die-away self-interrogation (DDSI). The proposed DDSI approach for spent fuel assembly assay utilizes primarily the spontaneous fission and (α, n) neutrons in the assemblies as an internal interrogating radiation source. The neutrons released in spontaneous fission or (α,n) reactions are thermalized in the surrounding water and induce fission in fissile isotopes, thereby creating a measurable signal from isotopes of interest that would be otherwise difficult to measure. The DDSI instrument employs neutron coincidence counting with 3He tubes and list-mode-based data acquisition to allow for production of Rossi-alpha distributions (RADs) in post-processing. The list-mode approach to data collection and subsequent construction of RADs has expanded the analytical possibilities, as will be demonstrated throughout this thesis. One of the primary advantages is that the measured signal in the form of a RAD can be analyzed in its entirety including determination of die-away times in different time domains. This capability led to the development of the early die-away method, a novel leakage multiplication determination method which is tested throughout the thesis on different sources in simulation space and fresh fuel experiments. The early die-away method is a robust, accurate, improved method of determining multiplication without the need for knowledge of the (α,n) source term. The DDSI technique and instrument are presented along with the many novel capabilities enabled by and discovered through RAD analysis. Among the new capabilities presented are the early die-away method, total plutonium content determination, and highly sensitive missing pin detection. Simulation of hundreds of different spent and fresh fuel assemblies were used to develop the analysis algorithms and the techniques were tested on a variety of spontaneous fission-driven fresh fuel assemblies at Los Alamos National Laboratory and the BeRP ball at the Nevada National Security Site. The development of the new, improved analysis and characterization methods with the DDSI instrument makes it a viable technique for implementation in a facility to meet material control and safeguards needs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytic computation of average energy of neutrons inducing fission

The objective of this report is to describe how I analytically computed the average energy of neutrons that induce fission in the bare BeRP ball. The motivation of this report is to resolve a discrepancy between the average energy computed via the FMULT and F4/FM cards in MCNP6 by comparison to the analytic results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Feynman Variance-To-Mean Measurements Using Measured and Simulated Data

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP multiplication patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength, reflector transmission, and the average number of neutrons released per 239 Pu fission ($\nu$). It is shown that when comparing the measured and simulated data while using the same method and parameters the inferred multiplication values agree within 5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased. The analysis method and parameters used can lead to a large spread of inferred multiplication values. In the future more configurations will be analyzed in a similar manner and a detailed uncertainty analysis will be performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Measured and Simulated List-Mode Data for Subcritical Systems

Measured and simulated list-mode data from the NPOD detector system were compared for subcritical systems. Five BeRP ball configurations reflected by polyethylene are investigated in this work. The simulated data were calculated using the MCNP list-mode patch developed at LANL. In addition to comparing the moments of the counting distributions, a full analysis was conducted to infer the multiplication of each system using both the Hansen-Dowdy and Hage-Cifarelli formulisms of the Feynman Variance-to-Mean Method. Several of the parameters that are input into these methods were also varied to determine their affect on the system multiplication. The main parameters investigated included the system source strength and reflector transmission. It is shown that when comparing the measured and simulated data while using the same method and parameters the multiplication values agree within 5.5%. The measured and simulated multiplication values differ more as the reflector thickness increases. The moments for the simulated data were higher than the measured data for all of the configurations and also disagreed more as the reflector thickness increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗