Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design, characterization, and performance of a hard x-ray transmission microscope at the National Synchrotron Light Source II 18-ID beamline

A transmission X-ray microscope (TXM) has been designed and commissioned at the 18-ID Fullfield X-ray Imaging (FXI) beamline at the National Synchrotron Light Source-II (NSLS-II). This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view (FOV) of about 40 microns. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under one minute. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Time-Resolved Research at the Advanced Photon Source Beamline 7-ID

The Sector 7 undulator beamline (7-ID) of the Advanced Photon Source (APS) is dedicated to time-resolved x-ray research and is capable of ultrafast measurements on the order of 100 ps. Beamline 7-ID has a laser laboratory featuring a Ti:Sapphire system (average power of 2.5W, pulse duration <50 fs, repetition rate 1-5 kHz) that can be synchronized to the bunch pattern of the storage ring. The laser is deliverable to x-ray enclosures, which contain diffractometers, as well as motorized optical tables for table-top experiments. Beamline 7-ID has a single APS Undulator A and uses a diamond (111) double-crystal monochromator, providing good energy resolution over a range of 6-24 keV. Available optics include Kirkpatrick-Baez (KB) mirrors to microfocus the x-ray beam. A variety of time-resolved diffraction and spectroscopy research is available at 7-ID, with experiments being done in the atomic, molecular, optical, chemistry, and solid state (bulk and surface) fields.

43 PARTICLE ACCELERATORS↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗

18-ID (FXI) Beamline Radiation Shielding Analysis

The18-ID beamline is a Full Field X-ray Imaging (FXI) beamline capable of imaging 3D in-situ and in-operando dynamics of sample morphology and oxidation states at 30 nm spatial resolution. The source of this beamline is a high-flux hard x-ray damping wiggler (DW100). The radiation shielding analysis of this beamline is described in this report.

36 MATERIALS SCIENCE↗

11-ID CHX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Coherent Hard X-ray Beamline (CHX, 11 ID) at 500 mA is documented in this technical note, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

23-ID CSX Beamline Radiation Shielding Analysis

The radiation shielding analysis of Coherent Soft X-ray Scattering and Polarization (CSX, 23 ID) beamline at 500 mA is documented in this memo, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

3-ID HXN Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Hard X-ray Nanoprobe (HXN, 3 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

10-ID IXS Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Inelastic X-ray Scattering (IXS, 10 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

28-ID XPD Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of X-ray Powder Diffraction (XPD, 28 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

5-ID SRX Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Submicron Resolution X-ray Spectroscopy (SRX, 5 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

07-ID SST Beamline Radiation Shielding Analysis

The 07-ID Spectroscopy Soft and Tender (SST) beamline is powered by two Undulators (U42 and EPU60) for the 2 beamlines; Soft (also known as the M branch) and Tender (L branch). The L branch is powered by the U42 out of vacuum undulator while the EPU60 (Elliptically Polarized Undulator) caters to the M branch.

36 MATERIALS SCIENCE↗

High-energy-resolution inelastic X-ray scattering spectrometer at beamline 30-ID of the Advanced Photon Source

Inelastic X-ray scattering is a powerful and versatile technique for studying lattice dynamics in materials of scientific and technological importance. In this article, the design and capabilities of the momentum-resolved high-energy-resolution inelastic X-ray spectrometer (HERIX) at beamline 30-ID of the Advanced Photon Source are reported. The instrument operates at 23.724 keV and has an energy resolution of 1.3–1.7 meV. It can accommodate momentum transfers of up to 72 nm -1 , at a typical X-ray flux of 4.5 × 10 9 photons s -1 meV -1 at the sample. A suite of in situ sample environments are provided, including high pressure, static magnetic fields and uniaxial strains, all at high or cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 10 12 photons s −1 ), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

36 MATERIALS SCIENCE↗

Portable laser-heating stand for synchrotron applications

A compact, double-sided laser-heating system for diamond-cell synchrotron applications is described. The optical table, containing laser, spectrometer, and all optics for visual observation and measuring temperatures and pressures has an area of less than (1/2) m{sup 2} and weighs less than 20 kg. All components can be remotely controlled at micron levels with simple dc motors and pneumatic drives. The design allows quick alignment of the laser-heated hot spot with the x-ray beam and the spectrometer. The prealigned system can be set up at most synchrotron beamlines within about 1 h. We carried out measurements on a variety of materials above one megabar and up to over 4000 K at both the x-ray diffraction beamline ID 27 and the x-ray absorption beamline ID 24 at the European Synchrotron Facility. A new measurement of the melting temperature of iron by x-ray absorption spectroscopy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗