Search NASASearch

SEARCH · Search NASA

Results for “Beamline IDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan

Label-based Virtual Directories In dCache

Traditional filesystems organize data in directories. These directories are typically a collection of files whose grouping is based on a single criterion, e.g., the starting date of an experiment, experiment name, beamline ID, measurement device, or instrument. However, each file in a directory can belong to several logical groups, such as a special event type, experiment condition, or a part of a selected dataset. dCache is a storage system developed to store large amounts of scientific data, used by many HEP and Photon Science experiments. With recent developments in dCache, we have introduced a concept of file tagging, which dynamically groups files with the same label into virtual directories. The file labels can be added, removed, renamed, and deleted through the admin interface or via REST API. The files in virtual directories are exposed through all protocols supported by dCache. This contribution will describe the details of the implementation for file tagging in dCache and present our future development plans on automatic metadata extractions, a feature that will significantly simplify data management. Additionally, we are exploring the future use of virtual directories as a way to translate scientific data catalogs into filesystem views for direct data analysis.

Sahakyan, Marina [DESY]

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar

Assessment of diagenesis in archaeological human second metacarpal bones using the intensity of the small angle X-ray scattering D -period peak

Bone consists mainly of carbonated apatite (cAp) nanoplatelets embedded in a matrix of collagen fibrils. Earlier, high-energy small angle X-ray scattering (SAXS) studies of archaeological adult human second metacarpal bones (mc2) found collagen D-period peaks with high-intensity I D in specimens in which microcomputed tomography (microCT) showed little diagenesis and I D ~ 0 for specimens where microCT revealed severe diagenesis (Park et al. 2022 Int. J. Osteoarchaeol. 32, 170–181 (doi:10.1002/oa.3053); Stock et al. 2022 Int. J. Osteoarchaeol. 32, 120–131 (doi:10.1002/oa.3049)). Here, the present paper uses SAXS at beamline 1-ID, Advanced Photon Source, Argonne National Laboratory and other techniques to study a set of 10 mc2 from an early Medieval cemetery at Greding, Germany. We hypothesized that non-invasive measurement of I D would provide an accurate and rapid (approx. 6 min/specimen) assessment of diagenesis in archaeological mc2. Results of Raman spectroscopy, laboratory microCT and backscattered electron, reflected light and polarized transmitted light microscopies confirmed the SAXS determinations, but lattice parameter values from X-ray diffraction were uncorrelated with I D value. Age-at-death estimates placed the 10 mc2 in three age categories (young adult, middle adult, old adult): lattice parameters from X-ray diffraction were uncorrelated with age at death. Cross-sectional bone area fraction from microCT dropped noticeably for the older age cohort.

Raman spectroscopy

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Beamline Device Designators

LAMP is to replace the front-end of LANSCE. Therefore, the device designators for LAMP needs approval from LANSCE. This document defines the agreed upon device designator names to be used in LAMP and in the prototype beamline LAMP in ADEF Tunnel (LAT).

43 PARTICLE ACCELERATORS

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

he LBNF absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF absorber radioactive water (RAW) cooling system which is designed as per ASME B31.3 normal fluid service. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 µs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were compared to allowable limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Status of 1eNp0π Charged-Current Electron Neutrino Cross Section on Argon in the NuMI Beam at ICARUS

The Short-Baseline Neutrino (SBN) Program is designed to probe short-baseline neutrino anomalies, including the LSND electron neutrino excess and the MiniBooNE low-energy excess. Essential to interpreting these anomalies and to the success of future experiments like DUNE, is the precise measurement of neutrino-argon interaction cross sections. The program utilizes two liquid argon time projection chamber (LArTPC) detectors: the Short-Baseline Near Detector (SBND) located 110 meters downstream from the Booster Neutrino Beam (BNB) target, and the ICARUS detector positioned 600 meters downstream. Additionally, the ICARUS detector lies off-axis to the NuMI beamline, providing a unique, high-statistics flux of electron neutrinos and sensitivity to energies that overlap with the DUNE spectrum. To analyze the data from these detectors, we have begun employing a machine-learning-based reconstruction algorithm referred to as “Scalable Particle Imaging with Neural Embeddings” (SPINE). SPINE has shown improvement in the ability to reconstruct the properties of final state particles in the detector, like the particle ID and momentum, with the potential to enhance the quality of measurements achievable within the SBN Program e.g., the resolution on kinematics used in differential cross section extraction. This poster presents progress toward measuring the electron neutrino argon interaction cross section in the 1eNp0π topology using the NuMI beam, highlighting the impact of SPINE through the ability to select signal events across a wide kinematic range without sacrificing background rejection power.

Carber, Dan [Colorado State U.] (ORCID:00090006451

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND