Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bearing fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. A recently proposed method to capture the rolling element bearing degradation provides the groundwork for new indicator families utilizing the generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the National Renewable Energy Laboratory Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox; hence the complexity of the vibration signals is similar to a real case. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators: Preprint

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. The underlying idea behind traditional indicators often revolves around tracking both cyclostationarity and abnormal impulses in the vibration signals without distinguishing the two. A recently proposed method to capture the rolling element bearing degradation lays out the groundwork for new indicator families utilizing generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the NREL Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox, hence the complexity of the vibration signals is similar to a real case. Furthermore, the new indicators are also tested with signals that carry multiple fault signatures. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

Review of mechanical vibration tests conducted on control moment gyros and life test fixtures

Experimental vibration studies performed on a number of flight control moment gyros and bearing life test fixtures are summarized. Tests were performed at MSFC, at Wyle Laboratories, Huntsville, Alabama, and at the Bendix Corporation facilities in Teterboro, New Jersey. A description of test and analysis equipment is included as well as test procedures and overall performance rankings. Advanced ultrasonic rolling element bearing fault detection techniques were applied for bearing analysis along with conventional vibration and sound analysis procedures.

Burchill, R. F.↗

A Review of Transmission Diagnostics Research at NASA Lewis Research Center

This paper presents a summary of the transmission diagnostics research work conducted at NASA Lewis Research Center over the last four years. In 1990, the Transmission Health and Usage Monitoring Research Team at NASA Lewis conducted a survey to determine the critical needs of the diagnostics community. Survey results indicated that experimental verification of gear and bearing fault detection methods, improved fault detection in planetary systems, and damage magnitude assessment and prognostics research were all critical to a highly reliable health and usage monitoring system. In response to this, a variety of transmission fault detection methods were applied to experimentally obtained fatigue data. Failure modes of the fatigue data include a variety of gear pitting failures, tooth wear, tooth fracture, and bearing spalling failures. Overall results indicate that, of the gear fault detection techniques, no one method can successfully detect all possible failure modes. The more successful methods need to be integrated into a single more reliable detection technique. A recently developed method, NA4, in addition to being one of the more successful gear fault detection methods, was also found to exhibit damage magnitude estimation capabilities.

Zakajsek, James J.↗

Transmission diagnostic research at NASA Lewis Research Center

The NASA Lewis Research Center and the U.S. Army Research Laboratory are involved in a joint research program to advance the technology of aerospace transmissions. Within the last six years, a transmission diagnostics research team was formed to address current and future technology barriers in transmission diagnostics. The diagnostics team conducted a survey to determine critical needs of the diagnostics community. Survey results indicated that experimental verification of gear and bearing fault detection methods and damage magnitude assessment were considered the two most critical research areas of a highly reliable health and usage monitoring system. A plan was implemented by the diagnostics team to address these key research areas, by in-house research and university grants. A variety of transmission fault detection methods were applied to experimentally obtained fatigue data. Failure modes of the fatigue tests include a variety of gear pitting failures, tooth wear, tooth fracture, and bearing spalling failures. Accomplishments to date include verification of several specific gear diagnostic methods, verification of a new pattern recognition method to determine failure, and development of a new method to model gear tooth damage. This paper presents the results of these accomplishments in transmission diagnostics research at NASA Lewis Research Center.

Zakrajsek, J. J.↗

Correlate Life Predictions and Condition Indicators in Helicopter Tail Gearbox Bearings

Research to correlate bearing remaining useful life (RUL) predictions with Helicopter Health Usage Monitoring Systems (HUMS) condition indicators (CI) to indicate the damage state of a transmission component has been developed. Condition indicators were monitored and recorded on UH-60M (Black Hawk) tail gearbox output shaft thrust bearings, which had been removed from helicopters and installed in a bearing spall propagation test rig. Condition indicators monitoring the tail gearbox output shaft thrust bearings in UH-60M helicopters were also recorded from an on-board HUMS. The spal-lpropagation data collected in the test rig was used to generate condition indicators for bearing fault detection. A damage progression model was also developed from this data. Determining the RUL of this component in a helicopter requires the CI response to be mapped to the damage state. The data from helicopters and a test rig were analyzed to determine if bearing remaining useful life predictions could be correlated with HUMS condition indicators (CI). Results indicate data fusion analysis techniques can be used to map the CI response to the damage levels.

Dempsey, Paula J.↗

Automatic Detection Of Faults In Turbomachinery Bearings

System of analog and digital signal-processing equipment, computers, and programs detects faults in ball bearings in turbomachines. System operates in real time, extracting information from vibrations sensed by accelerometers, strain gauges, and/or acoustical sensors. Vibrations caused when pits in balls contact races, and pits in races contact balls.

Higbie, Nathan B.↗

Planetary Gearbox Fault Detection Using Vibration Separation Techniques

Studies were performed to demonstrate the capability to detect planetary gear and bearing faults in helicopter main-rotor transmissions. The work supported the Operations Support and Sustainment (OSST) program with the U.S. Army Aviation Applied Technology Directorate (AATD) and Bell Helicopter Textron. Vibration data from the OH-58C planetary system were collected on a healthy transmission as well as with various seeded-fault components. Planetary fault detection algorithms were used with the collected data to evaluate fault detection effectiveness. Planet gear tooth cracks and spalls were detectable using the vibration separation techniques. Sun gear tooth cracks were not discernibly detectable from the vibration separation process. Sun gear tooth spall defects were detectable. Ring gear tooth cracks were only clearly detectable by accelerometers located near the crack location or directly across from the crack. Enveloping provided an effective method for planet bearing inner- and outer-race spalling fault detection.

Lewicki, David G.↗

Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

Dempsey, Paula J.↗

Detection of bearing failure in mechanical devices using neural networks

We present a novel time-domain method for the detection of faulty bearings that has direct applicability to monitoring the health of the turbo pumps on the Space Shuttle Main Engine. A feed-forward neural network was trained to detect modelled roller bearing faults on the basis of the periodicity of impact pulse trains. The network's performance was dependent upon the number of pulses in the network's input window and the signal-to-noise ratio of the input signal. To test the model's validity, we fit the model's parameters to an actual vibration signal generated by a faulty roller element bearing and applied the network trained on this model to detect faults in actual vibration data. When this network was tested on the actual vibration data, it correctly identified the vibration signal as a fault condition 76 percent of the time.

Burne, Richard A.↗

Design and fabrication of prototype system for early warning of impending bearing failure

A test program was conducted with the objective of developing a method and equipment for on-line monitoring of installed ball bearings to detect deterioration or impending failure of the bearings. The program was directed at the spin-axis bearings of a control moment gyro. The bearings were tested at speeds of 6000 and 8000 rpm, thrust loads from 50 to 1000 pounds, with a wide range of lubrication conditions, with and without a simulated fatigue spall implanted in the inner race ball track. It was concluded that a bearing monitor system based on detection and analysis of modulations of a fault indicating bearing resonance frequency can provide a low threshold of sensitivity.

Meacher, J.↗

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

A study of the use of vibration and stress wave sensing for the detection of bearing failure

Results from an experimental study of vibrations and stress waves emitted from ball bearings are presented. Fatique tests were run with both high quality bearings and man faulted bearings, all of one size. Tests were instrumented with different sensors to detect the noises from 10 Hz to 1 MHz. Frequency spectrum plots are presented. The modulation characteristics of the ultrasonic noises were analyzed, and acoustic emission type measurements were conducted. Results are presented which show that there are usable acoustic signal levels even beyond 500 KHz. These signal levels are modulated by a low frequency carrier which is a function of the stress loading and acoustic transmissibility. The results were correlated to fault size in the bearings. The correlation shows that the sensor used for signals from 100 KHz to 1 MHz gave the best sensitivity and detected the generation of very small spalls or pits.

Ensor, L. C.↗

Bearing Failure Detection

Shaker Research Corporation, under a contract with NASA, produced a test vehicle that measures resonant frequency of railroad roller bearings to identify source of bearings defects. Marshall scientists have developed a detection concept based on fact that bearing defects themselves excite resonant frequency of rolling elements of bearing as they impact the defect. By detecting resonant frequency and subsequently analyzing character of the signal, bearing defects may be detected and identified as to source. The bearing fault detector will help eliminate this cause of derailments.

Source record↗

Detecting faults in wind turbines

A wind turbine generator fault detection method is described. The method includes obtaining a first signal from a generator of a wind turbine and a second signal from a vibration sensor coupled to the wind turbine, the first signal representing an output current of the generator, and the second signal being a time-sampled signal representing vibrations of a bearing in the wind turbine. Determining a shaft rotation frequency signal from the first signal, the shaft rotation frequency signal representing a time-varying rotational speed of a shaft of the wind turbine. Resampling an envelope of the second signal based on the shaft rotation frequency signal to provide a third signal, the third signal being an angular sampled signal. Detecting, by the at least one processor, a fault in the bearing of the wind turbine by identifying a characteristic signature of a bearing fault in the third signal.

Qiao, Wei↗

Detecting faults in wind turbines

A wind turbine generator fault detection method is described. The method includes obtaining a first signal from a generator of a wind turbine and a second signal from a vibration sensor coupled to the wind turbine, the first signal representing an output current of the generator, and the second signal being a time-sampled signal representing vibrations of a bearing in the wind turbine. Determining a shaft rotation frequency signal from the first signal, the shaft rotation frequency signal representing a time-varying rotational speed of a shaft of the wind turbine. Resampling an envelope of the second signal based on the shaft rotation frequency signal to provide a third signal, the third signal being an angular sampled signal. Detecting, by the at least one processor, a fault in the bearing of the wind turbine by identifying a characteristic signature of a bearing fault in the third signal.

Qiao, Wei↗

In-Flight Detection of Vibration Anomalies in Unmanned Aerial Vehicles

Owing to the frequency of occurrence and high risk associated with bearings, identification and characterization of bearing faults in motors via nondestructive evaluation (NDE) methods have been studied extensively, amongst which vibration analysis has been found to be a promising technique for early diagnosis of anomalies. However, a majority of the existing techniques rely on vibration sensors attached onto or in close proximity to the motor in order to collect signals with a relatively high SNR. Due to weight and space restrictions, these techniques cannot be used in unmanned aerial vehicles (UAVs), especially during flight operations since accelerometers cannot be attached onto motors in small UAVs. Small UAVs are often subjected to vibrational disturbances caused by multiple factors such as weather turbulence, propeller imbalance or bearing faults. Such anomalies may not only pose risks to UAV's internal circuitry, components or payload, they may also generate undesirable noise level particularly for UAVs expected to fly in low-altitudes or urban canyon. This paper presents a detailed discussion of challenges in in-flight detection of bearing failure in UAVs using existing approaches and offers potential solutions to detect overall vibration anomalies in small UAV operations based on IMU data.

Portia Banerjee↗