Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bifacial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

Catching Rays: How Bifacial_Radiance Sheds Light on the Future of Solar PV

The challenge of energy transition is immediate and immense, with current projections targeting 75 TW of photovoltaics (PV) capacity globally by 2050. Alongside the rapid deployment is the "solar-coaster" ride the PV industry experiences with evolving technologies and novel installation methods. In 2016, NREL developed bifacial_radiance, a python open-source modeling tool for bifacial PV. This tool is a wrapper of the raytracing engine Radiance, which you all know better than us at this workshop. Bifacial_radiance integrates the many characteristics of common PV systems to model irradiance on both the front and rear sides of bifacial PV technology - a technology that now represents 75% of utility-scale deployment in the US. Bifacial_radiance has been pivotal for understanding bifacial system performance, shading, and edge effects, and now agrivoltaics research. It has also helped develop simplified models used in PV due diligence tools for optimizing new deployments or evaluating the performance of existing projects. Now, it's the go-to comparison tool for many university, and industry-developed systems modeling tools, and a pivotal tool for further research in photovoltaics. This talk will cover the needs bifacial_radiance addresses as an open-source tool, its development path, and the opportunity for any raytracer to shine light on the solar industry through research and practical application of modeling in regular site installations and novel setups like agrivoltaics and vertical panels at high latitudes (and even the South Pole!).

agrivoltaics↗

Monolithic Bifacial Halide Perovskite-Cadmium Selenide Telluride (CST) Tandem Thin-Film Solar Cells (Final Technical Report)

In this project, we develop a bifacial tandem design for monolithic metal halide perovskite-cadmium selenide telluride (CST) tandem solar cells. The bifacial tandem design not only enables the monolithic integration of perovskite-CST tandems but also delivers high efficiency by harvesting the albedo light. It also allows better current match and thus enables higher power output of the tandem devices than conventional tandem cells. We worked on understanding the critical factors limiting bifacial CST cells and developing strategies to improve their bifaciality. We also developed efficient wide-bandgap perovskite subcells and interconnecting layers that enable the monolithic perovskite-CST tandem solar cells. We successfully demonstrated prototype monolithic bifacial perovskite-CST tandem solar cells with bifacial equivalent efficiencies of more than 25% under an albedo of 0.4. Additionally, we optimized the wide-bandgap perovskite to realize four-terminal perovskite-CST tandem devices with efficiencies of 25.5% under monofacial illumination. The team disseminated these results to stakeholders in the PV academic and industry and discussed the challenges and major technical barriers for their market entry. The technologies developed in the project are promising but are not yet ready for immediate commercialization. Future fundamental study and R&D work are needed to advance these promising technologies.

14 SOLAR ENERGY↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Highly Efficient Bifacial Single Junction Perovskite Solar Cells

We report on efficient, single-junction bifacial perovskite solar cells (PSCs) that simultaneously exhibit high front-side-illumination power conversion efficiency (PCE) (over 22 %) and high bifaciality (over 91%), which represents a significant advancement for single junction bifacial PSC development. The bifacial PSCs exhibit substantial performance boost under concurrent front and rear illumination conditions. The stabilized power output goes up to 25.3 mW/cm 2 under albedos of 0.2, which is comparable to the state-of-the-art monofacial single-junction PSCs. Our work demonstrates the value and potential of bifacial single junction PSCs as an attractive direction for future scientific study and commercialization.

commercialization↗

Comparative Analysis of Rear Irradiance Modeling Methods for Bifacial PV Systems on Single-Axis Trackers Under Varying Albedo Conditions

This study compares three rear-side irradiance modeling methods for bifacial PV systems on single-axis trackers: (i) the 2D View Factor (VF) model in PVsyst(R), (ii) the open-source PVFactors VF model, and (iii) the Ray Tracing (RT) technique using bifacial_radiance. Simulations were benchmarked against field measurements from a pilot PV plant with rear-side sensors at the torque tube height. Results show that all models underestimated the non-uniformity of rear irradiance along the module length and overestimated the total rear irradiance incident on the module. However, since bifacial gain represents only a fraction of the system's total energy, the resulting energy yield differences among methods remained within +- 2 % of measured values, which is typical for such simulations. While the overall energy impact is limited, this study characterizes the specific limitations of each modeling approach, supporting further improvements in bifacial PV performance assessment methods.

14 SOLAR ENERGY↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗

PV Durability at Scale: Assessing Bifacial and TOPCon Field Performance

Recent field performance results of TOPCon and PERC Bifacial modules are presented based on small-scale deployments at NLR, and a selection of 3rd-party residential data. Bifacial PERC degradation rates are a median of -1 % / yr with bifacial TOPCon modules at a similar rate of -1.1 %/yr over the first couple of years. Comparable PERC Monofacial modules have a degradation rate of -0.5%/yr. Some TOPCon modules exhibited an indoor dark metastability effect which requires recovery by light soaking or UV exposure prior to IV curve measurement. Further monitoring is needed to confirm the long-term stability of TOPCon modules.

14 SOLAR ENERGY↗

IEA PVPS Task 13 Techno-Economic Study of Bifacial Photovoltaic Systems on Single Axis Trackers

The International Energy Agency PVPS Task 13 has assembled an international team of photovoltaic (PV) researchers from government labs, academia, and industry to study the specific application of bifacial PV modules deployed on tracking systems. This configuration is of particular interest as it has been identified as the PV system design with the lowest Levelized Cost of Electricity (LCOE) for over 90% of the world [1]. As such, much research, development, and commercial activity are focused on further optimizing this system design for different regions and markets, including field deployment and advanced modeling activities. Despite these efforts, many challenges remain to overcome with this system design. This conference paper will report on several areas the team is working on as part of this project. The first part of this study focuses on extensive interviews with PV tracker companies (we have identified 35) and customers worldwide to identify emerging technology trends, design diversity, market environments, and the reliability and performance of these systems. We will provide a market summary of technologies such as advanced tracking algorithms, methods for dealing with topography within the PV plant, different system configurations and layouts, backside irradiance optimization from albedo enhancement, and ground sculpting. We will also review dual-use applications of tracked bifacial systems, such as Agrivoltaics and Building-Integrated PV. These interviews are underway now, and we will be able to report our initial findings at the conference. The second part of the study focuses on summarizing performance monitoring and evaluation methods, with particular attention to capacity and acceptance testing for such systems. The third part of the study reviews performance modeling and yield assessment methods for these tracked bifacial PV systems. The final part of the study covers reliability and operations, and maintenance data from these systems.

albedo↗

Validating Irradiance Models for High-Latitude Vertical Bifacial Photovoltaic Systems

Bifacial photovoltaic systems oriented vertically facing east-west are an emerging design, targeting production in morning and afternoon hours and providing competitive annual energy yield to traditional south-tilted modules for high latitude locations. The accuracy of existing bifacial PV models when modules are oriented vertically has yet to be examined in detail. Here, we compare four bifacial PV irradiance models in ~150 locations between 15-80 degrees N on the utility-scale, finding higher inter-model deviations for vertical PV systems than south-tilted across all latitudes less than 75 degrees N. We validate model-predicted irradiance with test-site data collected in Golden, Colorado and Fairbanks, Alaska for E-W vertical and south-tilted arrays. View factor models agree with E-W vertical test-site data in Golden with RMSE=15%. Modelling error increases for the Alaskan test-site to RMSE values between 21-30%, driven in part by high albedo measurement uncertainty during snowy months.

bifacial↗

Artificial ground reflector size and position effects on energy yield and economics of single‐axis‐tracked bifacial photovoltaics

Abstract Artificial ground reflectors improve bifacial energy yield by increasing both front and rear‐incident irradiance. Studies have demonstrated an increase in energy yield due to the addition of artificial reflectors; however, they have not addressed the effect of varying reflector dimensions and placement on system performance and the impact of these parameters on the reflectors' financial viability. We studied the effect of high albedo (70% reflective) artificial reflectors on single‐axis‐tracked bifacial photovoltaic systems through ray‐trace modeling and field measurements. In the field, we tested a range of reflector configurations by varying reflector size and placement and demonstrated that reflectors increased daily energy yield up to 6.2% relative to natural albedo for PERC modules. To confirm the accuracy of our model, we compared modeled and measured power and found a root mean square error (RMSE) of 5.4% on an hourly basis. We modeled a typical meteorological year in Golden, Colorado, to demonstrate the effects of artificial reflectors under a wide range of operating conditions. Seventy percent reflective material can increase total incident irradiance by 1.9%–8.6% and total energy yield by 0.9%–4.5% annually after clipping is considered with a DC–AC ratio of 1.2. Clipping has a significant effect on reflector impact and must be included when assessing reflector viability because it reduces reflector energy gain. We calculated a maximum viable cost for these improvements of up to $2.50–4.60/m 2 , including both material and installation, in Golden. We expanded our analysis to cover a latitude range of 32–48°N and demonstrated that higher‐latitude installations with lower energy yield and higher diffuse irradiance content can support higher reflector costs. In both modeling and field tests, and for all locations, the ideal placement of the reflectors was found to be directly underneath the module due to the optimized rear irradiance increase.

14 SOLAR ENERGY↗

Sequential Stress Identifies Processing Defects in Bifacial Photovoltaic Modules That Limit Durability

Here, we use sequential stress to investigate hurdles to bifacial photovoltaic (PV) module durability from lamination defects. We test mini-modules with glass/glass (G/G) and glass/transparent-backsheet (G/TB) constructions using either ethylene vinyl acetate or polyolefin elastomer (POE) based encapsulants under a modified IEC 63209-2 sequential stress. This sequence includes multiple iterations of damp heat (DH200), full spectrum light exposure (A3), thermal cycling (TC50), and humidity/freeze (HF10). We compare indoor stress with outdoor exposure. Results show similar relative trends in degradation after a year outdoors compared to our first stress cycle. Subsequent stress cycles impart more severe damage than outdoor exposure for the short outdoor duration used here. Edge-pinch lamination defects in G/G mini-modules limit durability causing delamination and cell cracks. Conversely, we observe greater degradation in G/TB mini-modules compared to G/G in the later stages of the stress sequence when the backsheets are directly exposed to UV-containing light. Our results highlight: 1) the utility of sequential stress testing to uncover degradation modes in bifacial PV, 2) implications of using mini-modules for testing PV quality, and 3) the importance of lamination defects that must be avoided to ensure durability as the industry adopts G/G or G/TB packaging.

14 SOLAR ENERGY↗

A New Chapter in Solar: Bifacial PV from Emerging Topic to Core Curriculum

Associated with the new edition of the bifacial PV book, this talk reviews the transition of bifacial PV from niche innovation to standard practice, including progress in modeling and performance evaluation, and ongoing challenges in reliability, new applications, and fleet repowering.

14 SOLAR ENERGY↗

Bifacial PV: De Tudo um Pouco

A tecnologia fotovoltaica evolui constantemente, e desde aproximadamente 2017 os modulos bifaciais chegaram para ficar. A mudanca, que foi simples em termos de fabricacao das celulas PERC, oferece um grande ganho na producao de energia. E por isso que agora representam 75% das novas usinas centralizadas dos Estados Unidos. Nesta palestra, vou apresentar a pesquisa de PV bifacial no NREL, onde temos um campo de 75 kW com 5 tecnologias bifaciais comerciais ao lado dos equivalentes monofaciais (mesmas celulas), com dados open-source desde 2019. Vou falar sobre o que estamos observando em relacao a performance, degradacao, o posicionamento dos sensores de irradiacao, sombreamento e efeitos de borda (edge effects). Para terminar, apresentarei nova pesquisa sobre a otimizacao do albedo e agriPV, e compartilharei novidades nas ferramentas de modelagem bifacial e AgriPV desenvolvidas pelo NREL.

bifacial↗

Polarization-type potential-induced degradation in bifacial PERC modules in the field

This study examines the susceptibility of bifacial glass/glass passivated emitter and rear cell (PERC) modules to potential-induced degradation-polarization (PID-p) in the field. While there are several studies showing PID-p occurring on both front and back faces of bifacial PERC in accelerated tests, we address the yet unclarified behavior in fielded modules. We examine the effects of mounting configuration; specifically, comparing modules mounted near ground and in elevated ground rack configurations. Modules with the cell circuit in -1500 V system voltage configuration, whether mounted on racks about 30 cm above the ground or elevated 2 m high showed mean degradation of 4.5% to 6% in power under standard test conditions over about 2.5 weeks as measured from the front side of the module. This extent of degradation remained sustained for a duration of about 6 months analyzed. Average daytime temperatures of modules in the various mounting configurations were similar and therefore judged to be insufficient to be a primary influence for the modest PID-p rate differences that we observed among mounting configurations. Increased leakage current in the morning suggests morning dew was sustained longer on modules near the ground measured over six months which would be expected to increase the PID-p rate over the long term. However, the main difference seen between the modules on the various mountings during the initial period with up to 6% mean degradation by PID-p was the approximately two times the irradiance from albedo on the rear of modules mounted in elevated ground rack compared to those on the near ground rack. This difference in incident albedo led to a modestly reduced rate of the development of PID-p of the modules on the elevated ground rack. The difference is attributed to the dissipation of PID-p-causing electrical charge by the albedo incident on the module rear. The behavior could be modeled by a sigmoidal equation with consideration of the differences in the insolation on the module rear.

14 SOLAR ENERGY↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Bifacial Vertical Testbed and Ground Irradiance Data in Golden, Colorado

This data was collected for Tonita et al., “Vertical bifacial photovoltaic system model validation: study with field data, various orientations, and latitudes,” for validation of optical models for vertically-oriented photovoltaics under high albedo. Ground irradiance data for vertical PV arrays modeling in agrivoltaics is also provided. The dataset is provided for further use or study as open source. For any questions on the dataset, email silvana.ovaitt@nlr.gov.

14 SOLAR ENERGY↗