Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

NASA: Biomedical Applications Team

Biomedical applications of NASA technology are summarized and discussed. Included are: diagnostic devices, treatment aids, design improvements and patient tracking systems.

Source record↗

A Review on Iron Oxide Nanoparticles and Their Biomedical Applications

The iron oxide nanoparticles have a great attraction in biomedical applications due to their non-toxic role in the biological systems. The iron oxide nanoparticles have both magnetic behaviour and semiconductor property which lead to multifunctional biomedical applications. The iron oxide nanoparticles used in biomedical fields such as antibacterial, antifungal and anticancer were reviewed. The uses of hematite (α-Fe{sub 2}O{sub 3}), maghemite (γ-Fe{sub 2}O{sub 3}) and magnetite (Fe{sub 3}O{sub 4}) nanoparticles, for an inhibition time in biological activities, are listed in this work. Also, this review explains the use of iron oxide nanoparticles in the biomedical fields with particular attention to the application of hematite and superparamagnetic iron oxide nanoparticles. In this review, analysis reveals that the role of iron oxide in biological activity is good due to its biocompatibility, biodegradability, ease of synthesis and different magnetic behaviours. The change of properties of iron oxide nanoparticles such as particle size, morphology, surface, agglomeration and electronic properties has specific impact in biomedical application. The review mainly focused in and discussed about antibacterial, anticancer, bone marrow and cell labelling activities. From this review work, the iron oxide nanoparticle may be specialised in particular bacterial and cancer treatments. Also discussed are the iron oxide nanoparticle-specific biomedical applications like human placenta, insulin and retinal locus treatments.

60 APPLIED LIFE SCIENCES↗

Addressing Load Imbalance in Bioinformatics and Biomedical Applications: Efficient Scheduling across Multiple GPUs

Computational bioinformatics and biomedical applications frequently contain heterogeneously sized units of work or tasks, for instance due to variability in the sizes of biological sequences and molecules. Variable-sized workloads lead to load imbalances in parallel implementations which detract from efficiency and performance. Many modern computing resources now have multiple graphics processing units(GPUs) per computer for acceleration. These multiple GPU resources need to be used efficiently through balancing of workloads across the GPUs. OpenMP is a portable directive-based parallel programming API used ubiquitously in bioscience applications to program CPUs; recently, the use of OpenMP directives for GPU acceleration has become possible. Here, motivated by experiences with imbalanced loads in GPU-accelerated bioinformatics applications, we address the load balancing problem using OpenMP task-to-GPU scheduling combined with OpenMP GPU offloading for multiply heterogeneous workloads – loads with both variable input sizes, and simultaneously, variable convergence rates for algorithms with a stochastic component – scheduled across multiple GPUs. We aim to develop strategies which are both easy to use and have lower overheads, and may be incorporated incrementally in existing programs which already make use of OpenMP for CPU-based threading in order to make use of multi-GPU computers. We test different combinations of input size variability and convergence rate variability, and characterize the effects of these different scenarios on the performance of scheduling strategies across multiple GPUs with OpenMP. We present several dynamic scheduling solutions for different parallel patterns, explore optimizations, and provide publicly available example computational kernels to make these strategies easy to use in programs. This work will enable application developers to efficiently and easily use multiple GPUs for imbalanced workloads found in bioinformatics and biomedical applications.

Thavappiragasam, Mathialakan↗

Porosity modeling in a TiNbTaZrMo high-entropy alloy for biomedical applications

High-entropy alloys (HEAs) have attracted great attention for many biomedical applications. However, the nature of interatomic interactions in this class of complex multicomponent alloys is not fully understood. We report, for the first time, the results of theoretical modeling for porosity in a large biocompatible HEA TiNbTaZrMo using an atomistic supercell of 1024 atoms that provides new insights and understanding. Our results demonstrated the deficiency of using the valence electron count, quantification of large lattice distortion, validation of mechanical properties with available experimental data to reduce Young's modulus. We utilized the novel concepts of the total bond order density (TBOD) and partial bond order density (PBOD) via ab initio quantum mechanical calculations as an effective theoretical means to chart a road map for the rational design of complex multicomponent HEAs for biomedical applications.

36 MATERIALS SCIENCE↗

Optical emission spectroscopic diagnostics of a non-thermal atmospheric pressure helium-oxygen plasma jet for biomedical applications

In this work, we have applied optical emission spectroscopy diagnostics to investigate the characteristics of a non-thermal atmospheric pressure helium plasma jet. The discharge characteristics in the active and afterglow region of the plasma jet, that are critical for biomedical applications, have been investigated. The voltage-current characteristics of the plasma discharge were analyzed and the average plasma power was measured to be around 18 W. The effect of addition of small fractions of oxygen at 0.1%-0.5% on the plasma jet characteristics was studied. The addition of oxygen resulted in a decrease in plasma plume length due to the electronegativity property of oxygen. Atomic and molecular lines of selected reactive plasma species that are considered to be useful to induce biochemical reactions such as OH transitions A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=0) at 308 nm and A{sup 2}{Sigma}{sup +}({nu}=0,1){yields}X{sup 2}{Pi}({Delta}{nu}=1) at 287 nm, O I transitions 3p{sup 5}P{yields}3s{sup 5}S{sup 0} at 777.41 nm, and 3p{sup 3}P{yields}3s{sup 3}S{sup 0} at 844.6 nm, N{sub 2}(C-B) second positive system with electronic transition C{sup 3}{Pi}{sub u}{sup {yields}}B{sup 3}{Pi}{sub g}'' in the range of 300-450 nm and N{sub 2}{sup +}(B-X) first negative system with electronic transition B{sup 2}{Sigma}{sub u}{sup +}{yields}X{sup 2}{Sigma}{sub g}{sup +}({Delta}{nu}=0) at 391.4 nm have been studied. The atomic emission lines of helium were identified, including the He I transitions 3p{sup 3}P{sup 0}{yields}2s{sup 3}S at 388.8 nm, 3p{sup 1}P{sup 0}{yields} 2s{sup 1}S at 501.6 nm, 3d{sup 3}D{yields}2p{sup 3}P{sup 0} at 587.6 nm, 3d{sup 1}D{yields}2p{sup 1}P{sup 0} at 667.8 nm, 3s{sup 3}S{sup 1}{yields}2p{sup 3}P{sup 0} at 706.5 nm, 3s{sup 1}S{sup 0}{yields}2p{sup 1}P{sup 0} at 728.1 nm, and H{sub {alpha}} transition 2p-3d at 656.3 nm. Using a spectral fitting method, the OH radicals at 306-312 nm, the rotational and vibrational temperatures equivalent to gas temperatures of the discharge was measured and the effective non-equilibrium nature of the plasma jet was demonstrated. Our results show that, in the entire active plasma region, the gas temperature remains at 310 {+-} 25 K and 340 {+-} 25 K and it increases to 320 {+-} 25 K and 360 {+-} 25 K in the afterglow region of the plasma jet for pure helium and helium/oxygen (0.1%) mixture, respectively. Additionally, the vibrational temperatures range from 2200 {+-} 100 K and 2500 {+-} 100 K for pure helium and helium/oxygen (0.1%) mixture, respectively. The plasma jet was tested on heat sensitive polymer films used in biomedical applications such as polyethylene terephthalate and poly-L-lactide samples continuously for several minutes without causing any physical or thermal damage to the films. The plasma jet produces significant reactive species of interest while the gas temperatures remain very low demonstrating its potential for a range of biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biomedical applications team tasks

The status of the biomedical applications team is discussed along with its activity in applications engineering. Various technology requests are summarized.

Laenger, C. J., Sr.↗

Medical benefits from the NASA biomedical applications program

To achieve its goals the NASA Biomedical Applications Program performs four basic tasks: (1) identification of major medical problems which lend themselves to solution by relevant aerospace technology; (2) identification of relevant aerospace technology which can be applied to those problems; (3) application of that technology to demonstrate the feasibility as real solutions to the identified problems; and, (4) motivation of the industrial community to manufacture and market the identified solution to maximize the utilization of aerospace solutions to the biomedical community.

Sigmon, J. L.↗

Facile synthesis of SiO{sub 2} nanoparticles for biomedical applications

Silica nanoparticles (SiO{sub 2} NPs) for biomedical applications have been prepared by using a facile modified Stöber-synthesis. Potassium borohydride (KBH{sub 4}) has been introduced in the synthesis procedure in order to control NP size. Several samples have been prepared varying tetraethylorthosilicate (TEOS) concentration, and using different process conditions (temperature, reaction time and atmosphere). In order to study the influence of the process conditions on the NP size, morphology and properties, several characterization techniques were used. Size and morphology of the as-prepared SiO{sub 2} NPs have been studied by using Transmission Electron Microscope (TEM) and Dynamic Light Scattering (DLS) techniques. Structural characterization was carried out by X-ray powder diffraction. To investigate the SiO{sub 2} NP fluorescence emission properties the fluorescence spectroscopy was also used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface Characteristics of Titanium during ECM Process for Biomedical Applications

Electrochemical machining is described as the controlled removal of metal by anodic dissolution of the workpiece in electrolyte cell. Titanium is extensively used in aerospace, defence, biomedical applications. The human response to implanted titanium parts strongly related to the implant surface conditions. The aim of this paper is to present experimental investigation on electrochemically machined surface characteristics acquired on titanium, utilizing developed cross flow electrolyte system. It is observed that applied voltage and electrolyte flow rate are the some of the persuading parameter to attain desired surface characteristics on machined surface. Attempt has made to develop surface along with self-generated oxide layer, which facilitates in improving the corrosion and chemical resistance of titanium implant in biomedical application. The surface roughness of oxide layered machined surface obtained within 2.4 {mu}m to 2.93 {mu}m, which is within acceptable value for functional attachment between bone and implant.

36 MATERIALS SCIENCE↗

Biomedical Applications of NASA Science and Technology

During the period 15 September 1968 to 14 December 1968, the NASA supported Biomedical Application Team at the Research Triangle Institute has identified 6 new problems, performed significant activities on 15 of the active problems identified previously, performed 5 computer searches of the NASA aerospace literature, and maintained one current awareness search. As a partial result of these activities, one technology transfer was accomplished. As a part of continuing problem review, 13 problems were classified inactive. Activities during the quarter involved all phases of team activity with respect to biomedical problems. As has been observed in preceding years, it has been exceedingly difficult to arrange meetings with medical investigators during the fourth quarter of the calendar year. This is a result of a combination of factors. Teaching requirements, submission of grant applications and holidays are the most significant factors involved. As a result, the numbers of new problems identified and of transfers and potential transfers are relatively low during this quarter. Most of our activities have thus been directed toward obtaining information related to problems already identified. Consequently, during the next quarter we will follow up on these activities with the expectation that transfers will be accomplished on a number of them. In addition, the normal availability of researchers to the team is expected to be restored during this quarter, permitting an increase in new problem identification activities as well as follow-up with other researchers on old problems. Another activity scheduled for the next quarter is consultation with several interested biomedical equipment manufacturers to explore means of effective interaction between the Biomedical Application Team and these companies.

Brown, James N., Jr.↗

Polyvinyl Alcohol (PVA)–Azadirachta indica (Neem) Nanofibrous Mat for Biomedical Application: Formation and Characterization

The present study provides credence to the formation of polyvinyl alcohol (PVA)–Azadirachta indica (neem) nanofibrous mat (PNNM) under optimum processing conditions of electrospinning technique from a mixer of PVA and neem extract to utilize the inherent medicinal properties of this herb for biomedical application. The bonding behavior, orientation of fibers, thermal behavior, and moisture management properties were evaluated by Fourier transforms infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermo gravimetric analysis (TGA) and moisture management tester (MMT) reports respectively. The antibacterial activity of the developed sample at the maximum mixing ratio of neem extract (80%) was tested against Gram-positive (S. aureus) bacteria using agar disc diffusion method. The results reveal that the prepared nanofibrous mat exhibited better thermal and moisture management properties in comparison with PVA nanofiber alone. The formation of smooth fibers was confirmed by SEM images having average diameter of 185 nm under 5k, 10k and 15k magnifications. The characteristic peaks of PVA and neem constituents in FTIR spectra of the developed mat confirmed the presence of both components. Bacterial resistance was reached up to 20 mm due to the antibacterial constituents of neem extract. Thus the developed mat could be used as a biocompatible and bio based in biomedical applications. Graphic Abstract: .

36 MATERIALS SCIENCE↗

Hybrid magnetic nanoparticles as efficient nanoheaters in biomedical applications

Heating at the nanoscale is the basis of several biomedical applications, including magnetic hyperthermia therapies and heat-triggered drug delivery. The combination of multiple inorganic materials in hybrid magnetic nanoparticles provides versatile platforms to achieve an efficient heat delivery upon different external stimuli or to get an optical feedback during the process. However, the successful design and application of these nanomaterials usually require intricate synthesis routes and their magnetic response is still not fully understood. In this review we give an overview of the novel systems reported in the last few years, which have been mostly obtained by organic phase-based synthesis and epitaxial growth processes. Since the heating efficiency of hybrid magnetic nanoparticles often relies on the exchange-interaction between their components, we discuss various interface-phenomena that are responsible for their magnetic properties. Finally, followed by a brief comment on future directions in the field, we outline recent advances on multifunctional nanoparticles that can boost the heating power with light and combine heating and temperature sensing in a single nanomaterial.

36 MATERIALS SCIENCE↗