Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improved ultrasonic biomedical measuring apparatus

Device for making measurements of organs in living specimens and recording movements of organs is described. System uses series of ultrasonic pulses beamed into body of animal and reflected echo pulses are picked up by transducers and recorded. Diagram of equipment required and method of application is included.

Lee, R. D.↗

Ultrasonic biomedical measuring and recording apparatus

A train of ultrasonic pulses is beamed into the body of an animal. Organs intercepted by the beam reflect echo pulses following each transmitted pulse. An electronic gate with a variable width and a variable time delay relative to the transmitted pulse is utilized for selecting echoes derived from other organs or portions of organs. The integral of the echo signals received within the first half of the gate period is subtracted from a corresponding integral of the echo signal received during the second half of the gate to derive an error signal for controlling the time delay of the gate. In this manner, the selected echo signal is always maintained in the center of the gate.

Lee, R. D.↗

Shuttle era waste management and biowaste monitoring

The acquisition of crew biomedical data has been an important task on manned space missions. The monitoring of biowastes from the crew to support water and mineral balance studies and endocrine studies has been a valuable part of this activity. This paper will present a review of waste management systems used in past programs. This past experience will be cited as to its influence on the Shuttle design. Finally, the Shuttle baseline waste management system and the proposed Shuttle biomedical measurement and sampling systems will be presented.

Sauer, R. L.↗

Skylab medical data evaluation program (SMEDEP)

A day-by-day summary of selected data collected during the experiment is presented. The clinical and environmental data are presented in a mission-day format along with a tabulation of biomedical measurements whose values exceed three standard deviations from the preflight measurements.

Hoffler, G. W.↗

Poster — Thur Eve — 24: Commissioning and preliminary measurements using an Attix-style free air ionization chamber for air kerma measurements on the BioMedical Imaging and Therapy beamlines at the Canadian Light Source

Synchrotron facilities, including the Canadian Light Source (CLS), provide opportunities for the development of novel imaging and therapy applications. A vital step progressing these applications toward clinical trials is the availability of accurate dosimetry. In this study, a refurbished Attix-style (cylindrical) free air chamber (FAC) is tested and used for preliminary air kerma measurements on the two BioMedical Imaging and Therapy (BMIT) beamlines at the CLS. The FAC consists of a telescoping chamber that relies on a difference measurement of collected charge in expanded and collapsed configurations. At the National Research Council's X-ray facility, a Victoreen Model 480 FAC was benchmarked against two primary standard FACs. The results indicated an absolute accuracy at the 0.5% level for energies between 60 and 150 kVp. A series of measurements were conducted on the small, non-uniform X-ray beams of the 05B1-1 (∼8 – 100 keV) and 05ID-2 (∼20 – 200 keV) beamlines for a variety of energies, filtrations and beam sizes. For the 05B1-1 beam with 1.1 mm of Cu filtration, recombination corrections of less than 5 % could only be achieved for field sizes no greater than 0.5 mm × 0.6 mm (corresponding to an air kerma rate of ∼ 57 Gy/min). Ionic recombination thus presents a significant challenge to obtaining accurate air kerma rate measurements using this FAC in these high intensity beams. Future work includes measurements using a smaller aperture to sample a smaller and thus more uniform beam area, as well as experimental and Monte Carlo-based investigation of correction factors.

07 ISOTOPE AND RADIATION SOURCES↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Accuracy of Astroskin as a Behavioral Health Self-Monitoring System for Spaceflight

In space, there is a need to monitor astronauts' vital signs and assess their readiness to perform specific tasks during a mission. Currently, NASA does not have the capability to noninvasively monitor crew for extended periods of time. The Canadian Space Agency is working with the Psychophysiology Lab at NASA ARC to determine if the Astroskin could be used as a solution to this problem. Astroskin, a commercially available garment with built-in biosensors, can be comfortably worn under clothing or a spacesuit and relay information to the crewman's own mobile device. Data can also be sent wirelessly to the on-board Exploration Medical System. To determine if Astroskin meets requirements for health monitoring, it must first be validated in spaceflight analog environments. In the current study Astroskin data will be compared to traditional biomedical instrument measures of electrocardiography (ECG), respiration rate, and systolic blood pressure. The data will be recorded during Autogenic Feedback Training Exercise (AFTE), which is a type of physiological self-regulation training designed for astronauts. The data will also be recorded during simulations of the Orion spacecraft re-entry. The results to date suggest that Astroskin is a suitable ambulatory monitoring system that allows astronauts to self-diagnose and self-regulate adverse autonomic nervous system responses to sustained exposure to microgravity of spaceflight.

biomedical↗

Falls Risk Classification of Older Adults Using Deep Neural Networks and Transfer Learning

Prior research in falls risk classification using inertial sensors has relied on the use of engineered features, which has concluded in a feature space containing hundreds of features that are likely redundant and possibly irrelevant. In this paper, we propose using fully convolutional neural networks (FCNNs) to classify older adults at low or high risk of falling using inertial sensor data collected from a smartphone. Due to the limited nature of older adult inertial gait data sets, we first pre-train the FCNN models using a publicly available data set for pedestrian activity recognition. Then via transfer learning, we train the network for falls risk classification. We reveal that via transfer learning, our falls risk classifier obtains an area under the receiver operating characteristic curve of 93.3%, which is 10.6% higher than the equivalent model trained without the use of transfer learning. Moreover, we show that our method outperforms other standard machine learning classifiers trained on features developed in prior research.

60 APPLIED LIFE SCIENCES↗

An improved aesthesiometer

Biomedical tool measures cutaneous sensory perception by allowing consistent application of regular and determinable pressure to skin of the individual. Device is of relatively simple construction, inexpensive to manufacture, and easy to operate.

Wright, D.↗

Small-angle X-ray scattering characteristics of mouse brain: Planar imaging measurements and tomographic imaging simulations

Small-angle x-ray scattering (SAXS) imaging can differentiate tissue types based on their nanoscale molecular structure. However, characterization of the coherent scattering cross-section profile of relevant tissues is needed to optimally design SAXS imaging techniques for a variety of biomedical applications. Reported measured nervous tissue x-ray scattering cross sections under a synchrotron source have had limited agreement. We report a set of x-ray cross-section measurements obtained from planar SAXS imaging of 1 mm thick mouse brain (APP/PS1 wild-type) coronal slices using an 8 keV laboratory x-ray source. Two characteristic peaks were found at 0.96 and 1.60 nm -1 attributed to myelin. The peak intensities varied by location in the slice. We found that regions of gray matter, white matter, and corpus callosum could be segmented by their increasing intensities of myelin peaks respectively. Measured small-angle x-ray scattering cross sections were then used to define brain tissue scattering properties in a GPU-accelerated Monte Carlo simulation of SAXS computed tomography (CT) using a higher monochromatic x-ray energy (20 keV) to study design trade-offs for noninvasive in vivo SAXS imaging on a small-animal head including radiation dose, signal-to-noise ratio (SNR), and the effect of skull presence on the previous two metrics. Simulation results show the estimated total dose to the mouse head for a single SAXS-CT slice was 149.4 mGy. The pixel SNR was approximately 30.8 for white matter material whether or not a skull was present. In this early-stage proof-of-principle work, we have demonstrated our brain cross-section data and simulation tools can be used to assess optimal instrument parameters for dedicated small-animal SAXS-CT prototypes.

59 BASIC BIOLOGICAL SCIENCES↗

Semantic similarity between ontologies at different scales

In the past decade, existing and new knowledge and datasets has been encoded in different ontologies for semantic web and biomedical research. The size of ontologies is often very large in terms of number of concepts and relationships, which makes the analysis of ontologies and the represented knowledge graph computational and time consuming. As the ontologies of various semantic web and biomedical applications usually show explicit hierarchical structures, it is interesting to explore the trade-offs between ontological scales and preservation/precision of results when we analyze ontologies. This paper presents the first effort of examining the capability of this idea via studying the relationship between scaling biomedical ontologies at different levels and the semantic similarity values. We evaluate the semantic similarity between three Gene Ontology slims (Plant, Yeast, and Candida, among which the latter two belong to the same kingdom—Fungi) using four popular measures commonly applied to biomedical ontologies (Resnik, Lin, Jiang-Conrath, and SimRel). The results of this study demonstrate that with proper selection of scaling levels and similarity measures, we can significantly reduce the size of ontologies without losing substantial detail. In particular, the performance of Jiang-Conrath and Lin are more reliable and stable than that of the other two in this experiment, as proven by (a) consistently showing that Yeast and Candida are more similar (as compared to Plant) at different scales, and (b) small deviations of the similarity values after excluding a majority of nodes from several lower scales. This study provides a deeper understanding of the application of semantic similarity to biomedical ontologies, and shed light on how to choose appropriate semantic similarity measures for biomedical engineering.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A molecular dynamics study of water-soluble polymers: analysis of force fields from atomistic simulations

A force field (FF) analysis was performed on three water-soluble polymers (PAM, PNIPAAm, and PEO), that are of significant interest for biomedical applications, by measuring the polymer radius of gyration ( R g ), solvent accessible surface area (SASA), radial distribution functions ( g ( r )), and relative shape anisotropy ( κ 2 ) in dilute conditions. Three generalized FFs were utilized to model PAM and PNIPAAm (DREIDING, GAFF, and GAFF2) in conjunction with five water models: SPC, SPC/E, TIP3P, TIP4P, and TIP4P/2005. It was found that the DREIDING FF showed better agreement with PAM experimental data reported for R g , irrespective of the water model. For PNIPAAm, the DREIDING FF was also the best performing among the FFs studied; however, the choice of water model played an important role in the predicted properties. The trends in SASA and κ 2 are consistent with R g . For PEO modelled with the CHARMM C35r FF, all water models except TIP3P resulted in good agreement with experimental and previous simulation data. Furthermore these results highlight the considerable impact that polymer and water force fields can have on sampling appropriate polymer conformations in solvated systems.

36 MATERIALS SCIENCE↗

Experiment support system

The Experiment Support System is a switchboard system with displays and controls. It routes electrical power to experiments M092, M093, and M171 equipment; gaseous nitrogen to the Blood Pressure Measurement System; receives biomedical data from all related equipment; routes the conditioned data signals to the Airlock Module Telemetry System and also displays (in digital or analog from) portions of that data which the crewmen must see to complete the experiment successfully. The Experiment Support System is interfaced to the M131 control panel to transfer conditioned data to the Airlock Module Telemetry System.

Shannon, A. V.↗

Biomedical and Human Factors Requirements for a Manned Earth Orbiting Station

The primary objective of this study is to determine which biomedical and human factors measurements must be made aboard a space station to assure adequate evaluation of the astronaut's health and performance during prolonged space flights. The study has employed, where possible, a medical and engineering systems analysis to define the pertinent life sciences and space station design parameters and their influence on a measurement program. The major areas requiring evaluation in meeting the study objectives include a definition of the space environment, man's response to the environment, selection of measurement and data management techniques, experimental program, space station design requirements, and a trade-off analysis with final recommendations. The space environment factors that are believed to have a significant effect on man were evaluated. This includes those factors characteristic of the space environment (e. g. weightlessness, radiation) as well as those created within the space station (e. g. toxic contaminants, capsule atmosphere). After establishing the general features of the environment, an appraisal was made of the anticipated response of the astronaut to each of these factors. For thoroughness, the major organ systems and functions of the body were delineated, and a determination was made of their anticipated response to each of the environmental categories. A judgment was then made on the medical significance or importance of each response, which enabled a determination of which physiological and psychological effects should be monitored. Concurrently, an extensive list of measurement techniques and methods of data management was evaluated for applicability to the space station program. The various space station configurations and design parameters were defined in terms of the biomedical and human factors requirements to provide the measurements program. Research design of experimental programs for various station configurations, mission durations, and crew sizes were prepared, and, finally, a trade-off analysis of the critical variables in the station planning was completed with recommendations to enhance the confidence in the measurement program.

EARTH ORBIT↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

36 MATERIALS SCIENCE↗

Operation of the “Small” BioAMS spectrometers at CAMS: Past and future prospects

A summary of results from the solid samples run on our compact 1 MV AMS system over its 13.5 years of operation is presented. On average 7065 samples per year were measured with that average dropping to 3278 samples per year following the deployment of our liquid sample capability. Although the dynamic range of our spectrometer is 4.5 orders in magnitude, most of the measured graphitic samples had 14 C/C concentrations between 0.1 and 1 modern. Furthermore, the measurements of our ANU sucrose standard followed a Gaussian distribution with an average of 1.5082 ± 0.0134 modern. The LLNL biomedical AMS program supported many different types of experiments, however, the large majority of samples measured were derived from animal model systems. We have transitioned all of our biomedical AMS measurements to the recently installed 250 kV SSAMS instrument with good agreement compared in measured 14C/C isotopic ratios between sample splits. We then present results from replacement of argon stripping gas with helium in the SSAMS with a 22% improvement in ion transmission through the accelerator and high-energy analyzing magnet.

14C↗

Three axis vector atomic magnetometer utilizing polarimetric technique

The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗