Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Silicon nanoparticles as contrast agents in the methods of optical biomedical diagnostics

The efficiency of light scattering by nanoparticles formed using the method of picosecond laser ablation of silicon in water and by nanoparticles of mechanically grinded mesoporous silicon is compared. The ensembles of particles of both types possess the scattering coefficients sufficient to use them as contrast agents in optical coherence tomography (OCT), particularly in the range of wavelengths 700 – 1000 nm, where the absorption of both silicon and most biological and mimicking tissues is small. According to the Mie theory the main contribution to the scattering in this case is made by the particles having a relatively large size (150 – 300 nm). In the experiments on visualising the agar phantom surface by means of OCT, the contrast of the medium boundary, provided by nanoparticles amounted to 14 dB and 30 dB for the ablated particles and the porous silicon powder, respectively. The numerical simulation of OCT images of skin in the presence of nanoparticles, confirmed the efficiency of using them as a contrast agent. (nanoparticles)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Light scattering by a rough surface of human skin. 1. The luminance factor of reflected light

Based on the analytical solution of Maxwell's equations, we have studied the angular structure of the luminance factor of light reflected by the rough skin surface with large-scale relief elements, illuminated by a directed radiation beam incident at an arbitrary angle inside or outside the medium. The parameters of the surface inhomogeneities are typical of human skin. The calculated angular dependences are interpreted from the point of view of the angular distribution function of micro areas. The results obtained can be used for solving direct and inverse problems in biomedical optics, in particular for determining the depth of light penetration into a biological tissue, for studying the light action spectra on tissue chromophores under the in vivo conditions, for developing diagnostic methods of structural and biophysical parameters of a medium, and for optimising the mechanisms of interaction of light with biological tissues under their noninvasive irradiation through skin. (biomedical optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hoberman-sphere-inspired lattice metamaterials with tunable negative thermal expansion

Materials with engineered thermal expansion coefficients, capable of avoiding failure or irreversible destruction of structures and devices, are important for aerospace, civil, biomedical, optics, and semiconductor applications. In natural materials, thermal expansion usually cannot be adjusted easily and a negative thermal expansion coefficient is still uncommon. Here we propose a novel architected lattice bi-material system, inspired by the Hoberman sphere, showing a wide range of tunable thermal expansion coefficient from negative to positive, -1.04 x 10 -3 degrees C-1 to 1.0 x 10 -5 degrees C-1. Numerical simulations and analytical formulations are implemented to quantify the evolution of the thermal expansion coefficients and reveal the underlying mechanisms responsible for this unusual behavior. We show that the thermal expansion coefficient of the proposed metamaterials depends on the thermal expansion coefficient ratio and the axial stiffness ratio of the constituent materials, as well as the bending stiffness and the topological arrangement of the constitutive elements. The finding reported here provides a new routine to design architected metamaterial systems with tunable negative thermal expansion for a wide range of potential applications.

36 MATERIALS SCIENCE↗

Enhanced Tunability of Gold Nanoparticle Size, Spacing, and Shape for Large-Scale Plasmonic Arrays

Gold nanoparticles are important constituents in plasmonic arrays, lending themselves to electronic, optical, biomedical, sensing, and catalytic applications, among numerous others. Process variables that must be controlled when engineering plasmonic nanoparticle ensembles include nanoparticle size, shape, and spatial distribution on surfaces. The challenge in generating arrays of nanoparticles with control over these three parameters increases dramatically as spatial requirements for uniformity extend to larger processing areas. In this paper, we present a procedure that exploits thermally driven solid-state diffusional dewetting to yield considerable flexibility in generating ensembles of gold nanoparticles. Such submelting dewetting introduces fine control over particle spatial features that are currently difficult to achieve through conventional methods of generating nanoparticle arrays. Because of the simplicity of the process and its area-scalability, solid-state diffusional dewetting is shown here to be a method that could be easily scaled up to apply to large-area plasmonic fabrication processes.

36 MATERIALS SCIENCE↗

New approach for absolute fluence distribution calculations in Monte Carlo simulations of light propagation in turbid media

A novel way to attain three dimensional fluence rate maps from Monte-Carlo simulations of photon propagation is presented in this work. The propagation of light in a turbid medium is described by the radiative transfer equation and formulated in terms of radiance. For many applications, particularly in biomedical optics, the fluence rate is a more useful quantity and directly derived from the radiance by integrating over all directions. Contrary to the usual way which calculates the fluence rate from absorbed photon power, the fluence rate in this work is directly calculated from the photon packet trajectory. The voxel based algorithm works in arbitrary geometries and material distributions. It is shown that the new algorithm is more efficient and also works in materials with a low or even zero absorption coefficient. The capabilities of the new algorithm are demonstrated on a curved layered structure, where a non-scattering, non-absorbing layer is sandwiched between two highly scattering layers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online quantitative analysis of multispectral images of human body tissues

A method is developed for online monitoring of structural and morphological parameters of biological tissues (haemoglobin concentration, degree of blood oxygenation, average diameter of capillaries and the parameter characterising the average size of tissue scatterers), which involves multispectral tissue imaging, image normalisation to one of its spectral layers and determination of unknown parameters based on their stable regression relation with the spectral characteristics of the normalised image. Regression is obtained by simulating numerically the diffuse reflectance spectrum of the tissue by the Monte Carlo method at a wide variation of model parameters. The correctness of the model calculations is confirmed by the good agreement with the experimental data. The error of the method is estimated under conditions of general variability of structural and morphological parameters of the tissue. The method developed is compared with the traditional methods of interpretation of multispectral images of biological tissues, based on the solution of the inverse problem for each pixel of the image in the approximation of different analytical models. (biomedical optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of skin surface roughness degree on energy characteristics of light scattered by a biological tissue

We present the results of modelling of photometric characteristics of light in soft tissues illuminated by a parallel beam along the normal to the surface, obtained with allowance for the skin roughness parameters and the angular structure of radiation approaching the surface from within the tissue. The depth structure of the fluence rate and the spectra of the diffuse reflection of light by the tissue in the interval of wavelengths 300 – 1000 nm are considered. We discuss the influence of the tilt angle variance of rough surface microelements and light refraction on the studied characteristics. It is shown that these factors lead to the reduction of the radiation flux only in the near-surface tissue layer and practically do not affect the depth of light penetration into the tissue. On the other hand, the degree of the surface roughness and the conditions of its illumination from within the tissue essentially affect the coefficient of diffuse reflection of light and lead to its considerable growth compared to the cases of a smooth interface and completely diffuse illumination, often considered to simplify the theoretical problem solution. The role of the roughness of skin surface is assessed in application to the solution of different direct and inverse problems of biomedical optics. (paper)

60 APPLIED LIFE SCIENCES↗

Explicit solutions of the radiative transport equation in the P{sub 3} approximation

Purpose: Explicit solutions of the monoenergetic radiative transport equation in the P{sub 3} approximation have been derived which can be evaluated with nearly the same computational effort as needed for solving the standard diffusion equation (DE). In detail, the authors considered the important case of a semi-infinite medium which is illuminated by a collimated beam of light. Methods: A combination of the classic spherical harmonics method and the recently developed method of rotated reference frames is used for solving the P{sub 3} equations in closed form. Results: The derived solutions are illustrated and compared to exact solutions of the radiative transport equation obtained via the Monte Carlo (MC) method as well as with other approximated analytical solutions. It is shown that for the considered cases which are relevant for biomedical optics applications, the P{sub 3} approximation is close to the exact solution of the radiative transport equation. Conclusions: The authors derived exact analytical solutions of the P{sub 3} equations under consideration of boundary conditions for defining a semi-infinite medium. The good agreement to Monte Carlo simulations in the investigated domains, for example, in the steady-state and time domains, as well as the short evaluation time needed suggests that the derived equations can replace the often applied solutions of the diffusion equation for the homogeneous semi-infinite medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Advances in 3D Printed Sensors: Materials, Design, and Manufacturing

Sensors are of great importance in different aspects of research and industry. Future sensors will require high-efficient and low-cost manufacturing, as well as high-performance functionality in areas, such as mechanical sensing, biomedical, and optical applications. Recent advances in 3D printing open a new paradigm for sensors fabrication as a precision, customizable, and seamless process. Here, in this article, the state-of-the-art 3D printing methods in sensors manufacturing is reviewed and the performance of the 3D printed sensing materials and devices is summarized. Special attention is paid to emerging multimaterial printing and 4D printing technologies, which will benefit the fabrication of a new generation of structures with multifunctionalities. The content on 3D printed sensors covers piezoelectric sensors, medical, and optical sensing devices. The performance of 3D printed sensors in comparison with the sensors made by traditional manufacturing is also covered. Finally, section 4 provides the viewpoints on the future development of 3D printed sensors.

36 MATERIALS SCIENCE↗

Optical information transfer through random unknown diffusers using electronic encoding and diffractive decoding

Free-space optical information transfer through diffusive media is critical in many applications, such as biomedical devices and optical communication, but remains challenging due to random, unknown perturbations in the optical path. We demonstrate an optical diffractive decoder with electronic encoding to accurately transfer the optical information of interest, corresponding to, e.g., any arbitrary input object or message, through unknown random phase diffusers along the optical path. This hybrid electronic-optical model, trained using supervised learning, comprises a convolutional neural network-based electronic encoder and successive passive diffractive layers that are jointly optimized. After their joint training using deep learning, our hybrid model can transfer optical information through unknown phase diffusers, demonstrating generalization to new random diffusers never seen before. The resulting electronic-encoder and optical-decoder model was experimentally validated using a 3D-printed diffractive network that axially spans <70λ, where λ = 0.75 mm is the illumination wavelength in the terahertz spectrum, carrying the desired optical information through random unknown diffusers. The presented framework can be physically scaled to operate at different parts of the electromagnetic spectrum, without retraining its components, and would offer low-power and compact solutions for optical information transfer in free space through unknown random diffusive media.

36 MATERIALS SCIENCE↗

Optical-based spectroscopic methods for measuring chemical, optical, and physical properties of thin polymer waveguide films

Non-destructive optical-based spectroscopic methods are needed for analyzing “real world” devices that consist of thin polymer waveguide films. Many applications (e.g., sensors, microelectronics, optics, and biomedical applications, etc.) utilize thin polymer waveguide films, and non-destructive characterization methods based on Fourier transform (FT)-plasmon waveguide spectroscopy (PWR) and scanning angle (SA) Raman spectroscopy are used to extract optical, physical, and chemical properties simultaneously. The FT-PWR method measures reflected light at polymer waveguide interface as both the incident frequency (wavelength) and incident angle are scanned. This method uses p- and s-polarized light to simultaneously extract the polymer waveguide thickness and apparent anisotropic indices of refraction. Polystyrene waveguide films ranging from 360 to 800 nm are used to demonstrate the method and it has an average 0.4% relative error when compared to profilometry and atomic force microscopy measurements. SA Raman spectroscopy is used to measure mixed waveguide polymer films consisting of polystyrene-block-poly(methyl methacrylate) and homopolymer poly(methyl methacrylate) (PS-b-PMMA:PMMA), and poly(2-vinylnapthalene)-block-poly(methyl methacrylate) (P2VN-b-PMMA). PMMA homopolymer is added to the PS-b-PMMA solutions to vary the chemical composition. The chemical composition of each mixed film is quantified (SA Raman peak amplitude ratios) and averaged over all incident angles and is termed the Raman amplitude ratio (rps). This parameter is used to calculate the refractive index of each mixed waveguide polymer film. The refractive index is an input parameter for sum square electric field (SSEF) calculations, which are used to model SA Raman spectra as a function of incident angle to extract the film thickness. The mixed polymer waveguide film thicknesses ranged from 495 to 971 nm, and the SA Raman spectroscopy method has an average 5% difference between the values determined by profilometry. The SA Raman spectroscopy method developed for mixed polymer waveguide films is used to measure the chemical composition and extract interface locations in bilayer and trilayer films consisting of PMMA/PS or PMMA/PS/PMMA, respectively. The rps value is averaged over angle ranges corresponding to waveguide mode 0 and waveguide mode 1 for the bilayer and trilayer films, respectively. Six multilayer films are analyzed and their total thicknesses range from 330 to 1260 nm. Iterative SSEF calculations are used to model the SA Raman spectra as a function of incident angle, and the best fit to the experimental data is used to extract the total thickness and interface location(s). The method has an axial spatial resolution of 7 to 80 nm and provides comparable values to films measured by profilometry with an average 8% and 7% difference for the bilayer and trilayer films, respectively.

36 MATERIALS SCIENCE↗

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Solution precursor plasma deposition of nanostructured ZnO coatings

Highlights: {yields} The solution precursor route employed is an inexpensive process with capability to produce large scale coatings at fast rates on mass scale production. {yields} It is highly capable of developing tailorable nanostructures. {yields} This technique can be employed to spray the coatings on any kind of substrates including polymers. {yields} The ZnO coatings developed via solution precursor plasma spray process have good electrical conductivity and reflectivity properties in spite of possessing large amount of particulate boundaries, porosity and nanostructured grains. -- Abstract: Zinc oxide (ZnO) is a wide band gap semiconducting material that has various applications including optical, electronic, biomedical and corrosion protection. It is usually synthesized via processing routes, such as vapor deposition techniques, sol-gel, spray pyrolysis and thermal spray of pre-synthesized ZnO powders. Cheaper and faster synthesis techniques are of technological importance due to increased demand in alternative energy applications. Here, we report synthesis of nanostructured ZnO coatings directly from a solution precursor in a single step using plasma spray technique. Nanostructured ZnO coatings were deposited from the solution precursor prepared using zinc acetate and water/isopropanol. An axial liquid atomizer was employed in a DC plasma spray torch to create fine droplets of precursor for faster thermal treatment in the plasma plume to form ZnO. Microstructures of coatings revealed ultrafine particulate agglomerates. X-ray diffraction confirmed polycrystalline nature and hexagonal Wurtzite crystal structure of the coatings. Transmission electron microscopy studies showed fine grains in the range of 10-40 nm. Observed optical transmittance ({approx}65-80%) and reflectivity ({approx}65-70%) in the visible spectrum, and electrical resistivity (48.5-50.1 m{Omega} cm) of ZnO coatings are attributed to ultrafine particulate morphology of the coatings.

36 MATERIALS SCIENCE↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗