Search NASA⌕ Search

SEARCH · Search NASA

Results for “Blood Flow Velocity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cerebral blood flow velocity declines before arterial pressure in patients with orthostatic vasovagal presyncope

OBJECTIVES: We studied hemodynamic changes leading to orthostatic vasovagal presyncope to determine whether changes of cerebral artery blood flow velocity precede or follow reductions of arterial pressure. BACKGROUND: Some evidence suggests that disordered cerebral autoregulation contributes to the occurrence of orthostatic vasovagal syncope. We studied cerebral hemodynamics with transcranial Doppler recordings, and we closely examined the temporal sequence of changes of cerebral artery blood flow velocity and systemic arterial pressure in 15 patients who did or did not faint during passive 70 degrees head-up tilt. METHODS: We recorded photoplethysmographic arterial pressure, RR intervals (electrocardiogram) and middle cerebral artery blood flow velocities (mean, total, mean/RR interval; Gosling's pulsatility index; and cerebrovascular resistance [mean cerebral velocity/mean arterial pressure, MAP]). RESULTS: Eight men developed presyncope, and six men and one woman did not. Presyncopal patients reported light-headedness, diaphoresis, or a sensation of fatigue 155 s (range: 25 to 414 s) before any cerebral or systemic hemodynamic change. Average cerebral blood flow velocity (CBFV) changes (defined by an iterative linear regression algorithm) began 67 s (range: 9 to 198 s) before reductions of MAP. Cerebral and systemic hemodynamic measurements remained constant in nonsyncopal patients. CONCLUSIONS: Presyncopal symptoms and CBFV changes precede arterial pressure reductions in patients with orthostatic vasovagal syncope. Therefore, changes of cerebrovascular regulation may contribute to the occurrence of vasovagal reactions.

Non-NASA Center↗

Cerebral blood flow velocity and cranial fluid volume decrease during +Gz acceleration

Cerebral blood flow (CBF) velocity and cranial fluid volume, which is defined as the total volume of intra- and extracranial fluid, were measured using transcranial Doppler ultrasonography and rheoencephalography, respectively, in humans during graded increase of +Gz acceleration (onset rate: 0.1 G/s) without straining maneuvers. Gz acceleration was terminated when subjects' vision decreased to an angle of less than or equal to 60 degrees, which was defined as the physiological end point. In five subjects, mean CBF velocity decreased 48% from a baseline value of 59.4 +/- 11.2 cm/s to 31.0 +/- 5.6 cm/s (p<0.01) with initial loss of peripheral vision at 5.7 +/- 0.9 Gz. On the other hand, systolic CBF velocity did not change significantly during increasing +Gz acceleration. Cranial impedance, which is proportional to loss of cranial fluid volume, increased by 2.0 +/- 0.8% above the baseline value at the physiological end point (p<0.05). Both the decrease of CBF velocity and the increase of cranial impedance correlated significantly with Gz. These results suggest that +Gz acceleration without straining maneuvers decreases CBF velocity to half normal and probably causes a caudal fluid shift from both intra- and extracranial tissues.

NASA Discipline Cardiopulmonary↗

Cerebral blood flow velocity in humans exposed to 24 h of head-down tilt

This study investigates cerebral blood flow (CBF) velocity in humans before, during, and after 24 h of 6 deg head-down tilt (HDT), which is a currently accepted experimental model to simulate microgravity. CBF velocity was measured by use of the transcranial Doppler technique in the right middle cerebral artery of eight healthy male subjects. Mean CBF velocity increased from the pre-HDT upright seated baseline value of 55.5 +/- 3.7 (SE) cm/s to 61.5 +/- 3.3 cm/s at 0.5 h of HDT, reached a peak value of 63.2 +/- 4.1 cm/s at 3 h of HDT, and remained significantly above the pre-HDT baseline for over 6 h of HDT. During upright seated recovery, mean CBF velocity decreased to 87 percent of the pre-HDT baseline value. Mean CBF velocity correlated well with calculated intracranial arterial pressure (IAP). As analyzed by linear regression, mean CBF velocity = 29.6 + 0.32IAP. These results suggest that HDT increases CBF velocity by increasing IAP during several hours after the onset of microgravity. Importantly, the decrease in CBF velocity after HDT may be responsible, in part, for the increased risk of syncope observed in subjects after prolonged bed rest and also in astronauts returning to Earth.

Kawai, Y.↗

Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P < 0.01). No differences were observed in calculated cerebral vascular resistance between the four conditions. These data suggest that skin-surface cooling prevents the fall in CBFV during upright tilting and improves orthostatic tolerance, presumably via maintenance of MAP. Hence, skin-surface cooling may be a potent countermeasure to protect against orthostatic intolerance observed in heat-stressed humans.

Clinical Trial↗

Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

NASA Discipline Cardiopulmonary↗

Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

Frey, Mary A. B.↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction

Patients with idiopathic orthostatic intolerance (IOI) exhibit symptoms suggestive of cerebral hypoperfusion and an excessive decrease in cerebral blood flow associated with standing despite sustained systemic blood pressure. In 9 patients (8 women and 1 man aged 22 to 48 years) with IOI, we tested the hypothesis that volume loading (2000 cc normal saline) and alpha-adrenoreceptor agonism improve systemic hemodynamics and cerebral perfusion and that the decrease in cerebral blood flow with head-up tilt (HUT) could be attenuated by alpha-adrenoreceptor blockade with phentolamine. At 5 minutes of HUT, volume loading (-20+/-3.2 bpm) and phenylephrine (-18+/-3.4 bpm) significantly reduced upright heart rate compared with placebo; the effect was diminished at the end of HUT. Phentolamine substantially increased upright heart rate at 5 minutes (20+/-3.7 bpm) and at the end of HUT (14+/-5 bpm). With placebo, mean cerebral blood flow velocity decreased by 33+/-6% at the end of HUT. This decrease in cerebral blood flow with HUT was attenuated by all 3 interventions. We conclude that in patients with IOI, HUT causes a substantial decrease in cerebrovascular blood flow velocity. The decrease in blood flow velocity with HUT can be attenuated with interventions that improve systemic hemodynamics and therefore decrease reflex sympathetic activation. Moreover, alpha-adrenoreceptor blockade also blunts the decrease in cerebral blood flow with HUT but at the price of deteriorated systemic hemodynamics. These observations may suggest that in patients with IOI, excessive sympathetic activity contributes to the paradoxical decrease in cerebral blood flow with upright posture.

Non-NASA Center↗

Influence of Exercise Modality on Cerebral-Ocular Hemodynamics and Pressures

Background: Moderate and high intensity aerobic or resistance exercise has clearly identified benefits for cardiac, muscle, and bone health. However, the impact of such exercise - either as a mitigating or an exacerbating factor - on the development of the visual impairment and intracranial pressure syndrome (VIIP) is unknown. Accordingly, our aim was to characterize the effect of an acute bout of resistance (RE), moderate-intensity continuous (CE), and high-intensity interval exercise (IE) during a cephalad fluid shift on cerebral-ocular hemodynamics and pressures. Methods: 10 male subjects (36 plus or minus 9 years) completed 4 testing days in a 15 degree head-down tilt (HDT): (1) assessment of maximum volume of O (sub 2), (2) RE session (4 sets of 12 repetition maximum leg press exercise), (3) CE session (30 minutes of cycling at 60 percent maximum volume of O (sub 2)), and (4) IE session (4 by 4-minute intervals of exercise at 85 percent maximum volume of O (sub 2) with 3-minute active rest periods). During each session, blood flow (Vivid-e, GE Healthcare) in extracranial arteries (common carotid artery, CCA; internal carotid artery, ICA; external carotid artery, ECA and vertebral artery, VA), and mean blood flow velocity in middle cerebral artery (MCA), internal jugular pressure (IJP; VeinPress), and intraocular pressure (IOP; Icare PRO) were measured at rest, at the end of each resistance or interval set, and every 5 minutes during continuous exercise. Translaminar pressure gradient (TLPG) was estimated by subtracting IJP from IOP. Results: There were no differences across days in pre-exercise resting blood flows or pressures. IOP decreased slightly from HDT rest (20.2 plus or minus 2.3 millimeters of mercury) to exercise (RE: 19.2 plus or minus 2.8 millimeters of mercury; CE: 18.9 plus or minus 3.2 millimeters of mercury; IE: 20.1 plus or minus 2.8 millimeters of mercury), while IJP decreased during CE (31.6 plus or minus 9.5 millimeters of mercury) and RE (32.0 plus or minus 8.1 millimeters of mercury), and increased during IE (35.1 plus or minus 9.5 millimeters of mercury) from HDT rest (33.3 plus or minus 6.5 millimeters of mercury). Estimated TLPG was increased during IE only. Compared to RE and CE, IE resulted in the greatest increase in MCA blood flow velocity and extracranial artery blood flow. Conclusions: These preliminary results suggest that high-intensity IE acutely increases cerebral blood flow, IJP, and TLPG. Alterations in TLPG is one mechanism that may contribute to optic nerve sheath edema in astronauts. Accordingly, acutely raising IOP and/or orbital pressure during exercise could optimize cerebral-ocular pressures during spaceflight.

Scott, J.↗

Cerebral blood flow - Comparison of ground-based and spaceflight data and correlation with space adaptation syndrome

The relationship between the cerebral blood flow velocity and the space adaptation syndrome (SAS), which includes symptoms of motion sickness, stuffy head, and/or headaches, was investigated by measuring (using a transcranial Doppler device) differences between the preflight and the inflight cerebral blood flow velocity in crew members who were motion sick and in those who were not sick during a flight aboard KC-135. It was found that the cerebral artery bloodflow inflight did not differ significantly from that recorded preflight, nor did the severity of SAS symptoms correlate directly with the cerebral blood flow.

Bagian, James P.↗

Effect of Low Frequency Repetitive Transcranial Magnetic Stimulation (rTMS) Combined with Hyperbaric Oxygen (HBO) on Awakening of Coma Patients with Traumatic Brain Injury

Coma caused by craniocerebral injury is a common condition of neurosurgical acute injury. There is no specific method to promote awakening in a clinic. Early comprehensive treatment may be helpful to patients. The common methods are hyperbaric oxygen (HBO) and low-frequency repetitive transcranial magnetic stimulation (rTMS). However, the application effect and mechanism of rTMS combined with HBO on coma patients with traumatic brain injury need to be further studied. The brain stem auditory evoked potential (BAEP) is examined by the Kennedy coma recovery scale (CRS-R), the recovery of brain function and the state of consciousness are evaluated, and the therapeutic effect is evaluated by the Glasgow Coma Scale (GCS). Cerebrospinal fluid NE level, MCA blood flow velocity, and left brainstem and right brainstem auditory evoked potential are used to evaluate brain rehabilitation. RTMS combined with HBO could shorten the wake-up time, improve the wake-up rate, improve the GCS score and CRS-R score, shorten the brain wave latency time of the left and right brainstem, increase the NE level of cerebrospinal fluid, and decrease the blood flow velocity of MCA. RTMS combines with HBO can improve the nerve excitability of brain cells, reduce the disturbance of consciousness, promote the functional recovery of brain injury, and has a certain role in promoting the awakening of patients with traumatic brain injury coma.

Liu, Mei↗

An objective determination of +Gz acceleration tolerance

Until recently, human +Gz acceleration tolerance has relied solely on subjective criteria relating to loss of vision. By use of newly developed noninvasive instrumentation using a transcutaneous Doppler flow system, objective end point criteria have been developed based on measured blood flow to the head. The system consists of miniature 8 MHz Doppler sensors (2 x 1 x 0.5 cm) placed on the forehead over both frontal branches of the temporal arteries to detect blood flow velocity from back scattered ultrasound. Its use has allowed for correlation of altered, decreased and actual reversal of eye level blood flow with subsequent central light loss. Over 100 subjects have now been studied during more than 2,000 centrifuge runs. Objective changes in temporal artery flow velocity consistently preceded visual degradation for each subject during all acceleration profiles. No subject has gone unconscious without first exhibiting a minimum 6 sec of total flow cessation. Retrograde flow followed by complete flow cessation always preceded central light loss. Results indicate that this method can be successfully used with a wide variety of tasks during exposure to +Gz acceleration. It is recommended for use during evaluation of protective maneuvers or devices on the centrifuge or during actual flight in high performance aircraft. It may also serve as a potential safety monitor during space Shuttle re-entry if there is doubt about a passenger's cardiovascular status.

Unconsciousness/prevention & control↗

[Quantification and monitoring of vascular resistance in the lower limbs by the Doppler method (animal model)]

The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Transfer function analysis of dynamic cerebral autoregulation in humans

To test the hypothesis that spontaneous changes in cerebral blood flow are primarily induced by changes in arterial pressure and that cerebral autoregulation is a frequency-dependent phenomenon, we measured mean arterial pressure in the finger and mean blood flow velocity in the middle cerebral artery (VMCA) during supine rest and acute hypotension induced by thigh cuff deflation in 10 healthy subjects. Transfer function gain, phase, and coherence function between changes in arterial pressure and VMCA were estimated using the Welch method. The impulse response function, calculated as the inverse Fourier transform of this transfer function, enabled the calculation of transient changes in VMCA during acute hypotension, which was compared with the directly measured change in VMCA during thigh cuff deflation. Beat-to-beat changes in VMCA occurred simultaneously with changes in arterial pressure, and the autospectrum of VMCA showed characteristics similar to arterial pressure. Transfer gain increased substantially with increasing frequency from 0.07 to 0.20 Hz in association with a gradual decrease in phase. The coherence function was > 0.5 in the frequency range of 0.07-0.30 Hz and < 0.5 at < 0.07 Hz. Furthermore, the predicted change in VMCA was similar to the measured VMCA during thigh cuff deflation. These data suggest that spontaneous changes in VMCA that occur at the frequency range of 0.07-0.30 Hz are related strongly to changes in arterial pressure and, furthermore, that short-term regulation of cerebral blood flow in response to changes in arterial pressure can be modeled by a transfer function with the quality of a high-pass filter in the frequency range of 0.07-0.30 Hz.

NASA Discipline Cardiopulmonary↗

Cerebrovascular regulation in the postural orthostatic tachycardia syndrome (POTS)

Patients with the postural orthostatic tachycardia syndrome (POTS) have symptoms of orthostatic intolerance despite having a normal orthostatic blood pressure (BP), which suggests some impairment of cerebrovascular regulation. Cerebrovascular autoregulation refers to the maintenance of normal cerebral blood flow in spite of changing BP. Mechanisms of autoregulation include myogenic, metabolic and neurogenic vasoregulation. Beat-to-beat recording of blood-flow velocity (BFV) is possible using transcranial Doppler imaging. It is possible to evaluate autoregulation by regressing deltaBFV to deltaBP during head-up tilt. A number of dynamic methods, relating deltaBFV to deltaBP during sudden induced changes in BP by occluding then releasing peripheral arterial flow or by the Valsalva maneuver. The deltaBFV to deltaBP provides an index of autoregulation. In orthostatic hypotension, the autoregulated range is typically expanded. In contrast, paradoxical vasoconstriction occurs in POTS because of an increased depth of respiration, resulting in hypocapnic cerebrovascular constriction, and impaired autoregulation.

Review↗

Transcutaneous measurement of volume blood flow

Blood flow velocity measurements, using Doppler velocimeter, are described. The ability to measure blood velocity using ultrasound is derived from the Doppler effect; the change in frequency which occurs when sound is reflected or transmitted from a moving target. When ultrasound of the appropriate frequency is transmitted through a moving blood stream, the blood cells act as point scatterers of ultrasonic energy. If this scattered ultrasonic energy is detected, it is found to be shifted in frequency according to the velocity of the blood cells, nu, the frequency of the incident sound, f sub o, the speed of sound in the medium, c, and the angle between the sound beam and the velocity vector, o. The relation describing this effect is known as the Doppler equation. Delta f = 2 f sub o x nu x cos alpha/c. The theoretical and experimental methods are evaluated.

Daigle, R. E.↗

Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

Technology Portfolio System↗