Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bond Strength”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Proceedings of the First Annual Symposium for Nondestructive Evaluation of Bond Strength

Quantitative adhesive bond strength measurement has been an issue for over thirty years. Utilization of nonlinear ultrasonic nondestructive evaluation methods has shown more effectiveness than linear methods on adhesive bond analysis, resulting in an increased sensitivity to changes in bondline conditions. Correlation to changes in higher order material properties due to microstructural changes using nonlinear ultrasonics has been shown and could relate to bond strength. Nonlinear ultrasonic energy is an order of magnitude more sensitive than linear ultrasound to these material parameter changes and to acoustic velocity changes caused by the acoustoelastic effect when a bond is prestressed. This increased sensitivity will assist in getting closer to quantitative measurement of adhesive bond strength. Signal correlations between non-linear ultrasonic measurements and initialization of bond failures have been successfully measured. This paper reviews nonlinear bond strength research efforts presented by university and industry experts at the First Annual Symposium for Nondestructive Evaluation of Bond Strength organized by the NDE Sciences Branch at NASA Langley in November 1997.

Roberts, Mark J.↗

On a model of calculating bond strength

Diffusion bonding is a fabricating process to join the fibers and a matrix together forming a composite. The efficiency of the bonding process depends on temperature, time, and pressure. Based on a simplified pair potential model, an expression for the bond-energy at the fiber-matrix interface is formulated in terms of the above-mentioned three parameters. From this expression and the mean atomic distance, the bond-strength between the fibers and the matrix can be calculated.

Yue, A. S.↗

Nondestructive Determination of Bond Strength

Although many nondestructive techniques have been applied to detect disbonds in adhesive joints, no absolutely reliable nondestructive method has been developed to detect poor adhesion and evaluate the strength of bonded joints prior to the present work which used nonlinear ultrasonic methods to investigate adhesive bond cure conditions. Previously, a variety of linear and nonlinear ultrasonic methods with water coupling had been used to study aluminum-adhesive-aluminum laminates, prepared under different adhesive curing conditions, for possible bond strength determination. Therefore, in the course of this research effort, a variety of finite-amplitude experimental methods which could possibly differentiate various cure conditions were investigated, including normal and oblique incidence approaches based on nonlinear harmonic generation as well as several non-collinear two-wave interaction approaches. Test samples were mechanically scanned in various ways with respect to the focus of a transmitting transducer operated at several variable excitation frequencies and excitation levels. Even when powerful sample-related resonances were exploited by means of a frequency scanning approach, it was very difficult to isolate the nonlinear characteristics of adhesive bonds. However, a multi-frequency multi-power approach was quite successful and reliable. Ultrasonic tone burst signals at increasing power levels, over a wide frequency range, were transmitted through each bond specimen to determine its excitation dependent nonlinear harmonic resonance behavior. Relative amplitude changes were observed particularly in the higher harmonic spectral data and analyzed using a local displacement and strain analysis in the linear approximation. Two analysis approaches of the excitation-dependent data at specific resonances were found to be quite promising. One of these approaches may represent a very robust algorithm for classifying an adhesive bond as being properly cured or not. Another approach, in addition to differentiation between various cure conditions, may even provide information with respect to the bond strength. Several technical papers were published during the course of this research and a summary is presented in the Ph.D. dissertation of Tobias P. Berndt, a graduate student financially supported by this NASA Grant.

Source record↗

Measurement System Analysis of a Novel Phase-Based Ultrasonic NDE Technique for Bond Strength Measurement

Fiber reinforced polymer parts have shown tremendous benefits in aerospace structural applications, but their qualification and certification for use in safety critical areas are currently hindered by the lack of a capable non-destructive evaluation (NDE) method or technique for the inspection of these adhesively bonded parts. Conventional NDE methods and techniques typically detect gross bond defects in a qualitative (Pass/Fail) manner. These techniques struggle to detect weak or kissing bonds. Also, there are no widely adopted NDE methods or techniques for measuring interfacial bond strength or detecting kissing bonds. Bond strength is currently ensured by process control and semi-destructive testing. Results from recent research from other authors, including but not limited to mechanical testing, have shown an excellent correlation between interfacial stiffness of an adhesively bonded joint and the adhesive bond strength of that joint. In this paper, a measurement system analysis (MSA) of a novel phase-based ultrasonic NDE Technique, developed at NASA Langley Research Center, is presented for bond strength measurement to assess at an increased level the measurement process and identify components of variation in that measurement process.

Ultrasound↗

Proceedings of the Second Annual Symposium for Nondestructive Evaluation of Bond Strength

Ultrasonics, microwaves, optically stimulated electron emission (OSEE), and computational chemistry approaches have shown relevance to bond strength determination. Nonlinear ultrasonic nondestructive evaluation methods, however, have shown the most effectiveness over other methods on adhesive bond analysis. Correlation to changes in higher order material properties due to microstructural changes using nonlinear ultrasonics has been shown related to bond strength. Nonlinear ultrasonic energy is an order of magnitude more sensitive than linear ultrasound to these material parameter changes and to acoustic velocity changes caused by the acoustoelastic effect when a bond is prestressed. Signal correlations between non-linear ultrasonic measurements and initialization of bond failures have been measured. This paper reviews bond strength research efforts presented by university and industry experts at the Second Annual Symposium for Nondestructive Evaluation of Bond Strength organized by the NDE Sciences Branch at NASA Langley in November 1998.

Roberts, Mark J.↗

An Experimental Investigation of Silicone-to-Metal Bond Strength in Composite Space Docking System Seals

The National Aeronautics and Space Administration (NASA) is currently developing a new universal docking mechanism for future space exploration missions called the Low Impact Docking System (LIDS). A candidate LIDS main interface seal design is a composite assembly of silicone elastomer seals vacuum molded into grooves in an electroless nickel plated aluminum retainer. The strength of the silicone-tometal bond is a critical consideration for the new system, especially due to the presence of small areas of disbond created during the molding process. In the work presented herein, seal-to-retainer bonds of subscale seal specimens with different sizes of intentional disbond were destructively tensile tested. Nominal specimens without intentional disbonds were also tested. Tension was applied either uniformly on the entire seal circumference or locally in one short circumferential length. Bond failure due to uniform tension produced a wide scatter of observable failure modes and measured load-displacement behaviors. Although the preferable failure mode for the seal-to-retainer bond is cohesive failure of the elastomer material, the dominant observed failure mode under the uniform loading condition was found to be the less desirable adhesive failure of the bond in question. The uniform tension case results did not show a correlation between disbond size and bond strength. Localized tension was found to produce failure either as immediate tearing of the elastomer material outside the bond region or as complete peel-out of the seal in one piece. The obtained results represent a valuable benchmark for comparison in the future between adhesion loads under various separation conditions and composite seal bond strength.

Gaier, James R.↗

Nondestructive evaluation of adhesive bond strength using the stress wave factor technique

Acousto-ultrasonic nondestructive evaluation has been conducted to evaluate the adhesive bond strength between rubber and steel plates using the stress wave factor (SWF) measurement technique. Specimens with different bond strength were manufactured and tested using the SWF technique. Two approaches were used to define the SWF. One approach defines the SWF as the signal energy and the other approach defines the SWF as the square root of the zero moment of the frequency spectrum of the received signal. The strength of the rubber-steel adhesive joint was then evaluated using the destructive peel strength test method. It was observed that in both approaches higher values of the SWF measurements correspond to higher values of the peel strength test data. Therefore, these results show that the stress wave factor technique has the potential of being used in quality assurance of the adhesive bond strength between rubber and steel substrates.

Dos Reis, Henrique L. M.↗

Measurement of the intrinsic bond strength of brittle thin films on flexible substrates

The brittle cracking and subsequent debonding of nickel films deposited on polymer substrates subjected to uniaxial strain is investigated. Stress analyses for a film/substrate system are performed. Based on the analysis, the interfacial bond strength between brittle thin films and flexible substrates can be evaluated in terms of the tensile strength of the coating and the length of the largest segment that first debonds. Experiments were performed on Ni films with different thicknesses evaporated on polyethylene terephthalate substrates and the intrinsic bond strength was evaluated. The interfacial bond strengths were shown to be relatively independent of the film thickness for the range studied.

Guo, Q.↗

Carbon Nanotube Bonding Strength Enhancement Using Metal "Wicking" Process

Carbon nanotubes grown from a surface typically have poor bonding strength at the interface. A process has been developed for adding a metal coat to the surface of carbon nano tubes (CNTs) through a wicking process, which could lead to an enhanced bonding strength at the interface. This process involves merging CNTs with indium as a bump-bonding enhancement. Classical capillary theory would not normally allow materials that do not wet carbon or graphite to be drawn into the spacings by capillary action because the contact angle is greater than 90 degrees. However, capillary action can be induced through JPL's ability to fabricate oriented CNT bundles to desired spacings, and through the use of deposition techniques and temperature to control the size and mobility of the liquid metal streams and associated reservoirs. A reflow and plasma cleaning process has also been developed and demonstrated to remove indium oxide, and to obtain smooth coatings on the CNT bundles.

Lamb, James L.↗

Fibre-matrix bond strength studies of glass, ceramic, and metal matrix composites

An indentation test technique for compressively loading the ends of individual fibers to produce debonding has been applied to metal, glass, and glass-ceramic matrix composites; bond strength values at debond initiation are calculated using a finite-element model. Results are correlated with composite longitudinal and interlaminar shear behavior for carbon and Nicalon fiber-reinforced glasses and glass-ceramics including the effects of matrix modifications, processing conditions, and high-temperature oxidation embrittlement. The data indicate that significant bonding to improve off-axis and shear properties can be tolerated before the longitudinal behavior becomes brittle. Residual stress and other mechanical bonding effects are important, but improved analyses and multiaxial interfacial failure criteria are needed to adequately interpret bond strength data in terms of composite performance.

Grande, D. H.↗

Intrinsic bond strength of metal films on polymer substrates

A semiquantitative method for the measurement of the intrinsic bond strength between elastic substrates and elastic films that fail by brittle fracture is described. Measurements on a polyethylene terephthalate (PET)-Ni couple were used to verify the essential features of the analysis. It was found that the interfacial shear strength of Ni on PET doubled after ion etching.

Wheeler, Donald R.↗

Braze alloy holds bonding strength over wide temperature range

Copper-based quaternary alloys of the solid solution type is used for vacuum furnace brazing of large stainless steel components at a maximum temperature of 1975 deg F. The alloy has high bonding strength and good ductility over a temperature range extending from the cryogenic region to approximately 800 deg F.

Source record↗

Nondestructive testing techniques used in analysis of honeycomb structure bond strength

DOT /Driver-Displacement Oriented Transducer/, applicable to both lap shear type application and honeycomb sandwich structures, measures the displacement of the honeycomb composite face sheet. It incorporates an electromagnetic driver and a displacement measuring system into a single unit to provide noncontact bond strength measurements.

Erdman, D. C.↗