Search NASA⌕ Search

SEARCH · Search NASA

Results for “Booster Separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Fast Spectrum Test Loop at the Advanced Test Reactor

The United States currently has no infrastructure to provide a fast neutron flux for research purposes. With the increased interest in Sodium Fast Reactor (SFR) technology, this type of infrastructure is necessary for further development of key components such as Versatile Test Reactor. The purpose of this research is to characterize the thermal hydraulics of a test loop capable of providing SFR like operating conditions. This includes showcasing feasibility in mechanical design, reaching a high fast to thermal neutron flux ratio ideally near 15, an inlet temperature of 600 K, a temperature increase of 50 K from inlet to outlet, and test chamber radial temperature profiles similar to SFR fuel rods. Existing infrastructure must be used to provide the neutron flux for the test loop, and it was decided that the Advanced Test Reactor (ATR) was the optimal choice due to its availability and previous work conducted similar to this project. To achieve the goals of this project, several mechanical designs were put forward with the most feasible design being chosen. The neutronics and thermal hydraulics analysis were conducted in tandem, with an iterative process used to maximize efficiency of both systems. Analysis of the neutronics system was done using Attila and MCNP while the thermal hydraulic analysis was done using RELAP5. This document outlines the thermal hydraulic analysis, though it includes the results from the mechanical design and neutronics analysis. The loop design includes a primary system with molten sodium, a set of “booster fuel plates” to increase the fast flux within the test section, a water system to cool the booster fuel plates, a helium system to separate the sodium and water systems, and a thermal neutron shield to decrease the thermal flux. Each of these systems is modeled in the neutronics and thermal hydraulic analyses. The RELAP5 model showcased the feasibility of the design proposed by this report. For all designs tested, the desired 50 K temperature increase from inlet to outlet was reached. The fuel rod radial temperature profile was lower than was expected, likely due to a lower rod thermal power than expected. A parametric study was also conducted to characterize the system with three fuel pins. This study showed the effect of thermal power, fluid pressure, fluid velocity, and inlet temperature on the system. ©Copyright by Anton Higgins December 11, 2019 All Rights Reserved

99 GENERAL AND MISCELLANEOUS↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Synchronization and phase locking of resonant magnet power supplies for Mu2e experiment at Fermilab

The Mu2e Experiment has stringent beam structure requirements; namely, it requires short (~200 ns) proton bunches separated by 1.5-2.0 $\mu$s. This beam structure will be produced using the Fermilab 8 GeV Booster, the 8 GeV Recycler Ring, and the Delivery Ring, which was formerly part of the antiproton accumulator system. Out of time beam is limited to a fraction of level of no more than $1\times 10^{-10}$, a requirement known as "extinction". Achieving this level of extinction requires a system of resonant magnets and collimators, phased such that only in time particles will pass through. The Mu2e magnet system involves two components: a 300 kHz component, timed such that the 600 kHz beam will pass through the collimators at the nodes, and a 4.5 MHz system to reduce the slewing of the in-time beam. These two systems must be precisely phase locked to the bunch rate coming from the Delivery Ring, which itself must be phased to match beam transfers coming from the Recycler. This poster describes the control system for the magnets, which is based on an Intel Arria FPGA, which handles phase locking of the magnets to the Delivery Ring, including the phase jumps required to match transfers from the Recycler.

43 PARTICLE ACCELERATORS↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning results of the BNL Alternating Gradient Synchrotron booster AC dipole

Here, an AC dipole has been installed in the AGS booster as part of polarized beam developments for the future Electron Ion Collider (EIC). This will allow preserving helion beam polarization through two intrinsic resonances during acceleration to an energy corresponding to |$Gγ$| = 10.5. AC dipoles can preserve polarization by forcing the beam to undergo large amplitude vertical betatron oscillations. These coherent oscillations cause all particles to sample the strong horizontal fields of quadrupoles, and result in a full spin flip. In preparation for the AC dipole being used for polarized helions, it was first commissioned with polarized protons. The proton extraction energy was raised to allow protons to cross $Gγ$ = 0 + $v_y$ = 4.8087. As an artifact of the experiment using polarized protons, the booster settings for bunch extraction interfered with the coherent oscillations and limited the maximum coherent amplitude. This interference will be well separated in the case of polarized helions. Polarized protons crossed the $Gγ$ = 0 + $v_y$ intrinsic resonance with a full spin flip through use of the AC dipole. Simulations of the resonance crossing using Zgoubi accurately predict the polarization relative to the coherent amplitude.

43 PARTICLE ACCELERATORS↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Time Slicing of Neutrino Fluxes in Oscillation Experiments at Fermilab

Long and short baseline neutrino oscillation experiments, such as DUNE, SBND, demand high precision in reducing systematic errors, particularly those related to neutrino-nucleus interaction cross-sections. The stroboscopic approach offers a method to capture distinct neutrino energy spectra, aiding in the separation of flux and cross-section uncertainties. This report outlines the creation of short proton bunch lengths and the transport of a narrow beam down the Booster Neutrino Beamline, essential steps for the successful implementation of the stroboscopic approach.

43 PARTICLE ACCELERATORS↗

MicroBooNE Electron-Neutrino Cross-Section Results

Measurement of the electron-neutrino cross-section with argon ($\nu$-Ar) is crucial for current and future neutrino experiments. Results from MicroBooNE detector, a liquid argon time projection chamber (LArTPC) based at Fermilab, provide the most extensive and precise determination of these electron-neutrino cross-sections. MicroBooNE is situated on both on-axis and off-axis beams: the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam, respectively. The background for both beams is dominated by showers from neutral pion decay, necessitating an electron-photon separation technique. In this proceeding, we review three recent electron-neutrino cross-section results from MicroBooNE using NuMI and BNB.

Guzzo, Marina [Edinburgh U.]↗

RECORD FAST CYCLING ACCELERATOR MAGNET BASED ON HIGH TEMPERATURE SUPERCONDUCTOR

We report on the High Temperature Superconductor (HTS) based prototype accelerator magnet capable to operate at 12 T/s B-field ramping rate with a very low supporting cryogenic cooling power thus indicating a feasibility of its application in the accelerator requiring high repetition rate and high average beam power. The magnet is designed to simultaneously accelerate two particle beams in the separate beam gaps energized by a single conductor. The design, construction and the power test of the prototype fast-cycling HTS based accelerator magnet is presented while the more detailed description and power test data analysis s given in [1]. As example, the measured cryogenic power loss limit is discussed in terms of the feasibility of application of such a magnet for the construction of the 8 GeV dual proton beam Booster.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of Fermilab Rapid-Cycling Booster Gradient Magnets

Fermilab is upgrading its Booster synchrotron to increase ramp rate and intensity. This is part of the Proton Improvement Plan (PIP-II) that will allow the Main Injector to achieve proton beam power of 1.2 MW within the next few years. This upgrade includes running the 55-year-old Booster magnets at 20 Hz instead of the usual 15 Hz, and construction of some shorter and wider aperture versions of these combined-function gradient magnets. Magnetic measurements were performed to characterize the present 15 Hz AC performance, and then again with 20 Hz ramp cycle to ensure performance and compatibility in this new operating regime. A 3 m-long curved flat-coil was developed for these measurements using Printed Circuit Board (PCB) technology. The probe also has a separate 0.5 m-long body-field probe, allowing integral, body, and end fields to be measured across 100 mm of the magnet aperture. The sampling rate for these measurements during the AC cycle was 200 kHz, and field resolution was better than 0.01%. Details of the probe, measurements, and results are presented.

DiMarco, J. [Fermilab] (ORCID:0000000228400036)↗

Cryogenics and purification systems of the ICARUS T600 detector installation at Fermilab

This paper describes the cryogenic and purification systems of the ICARUS T600 detector in its present implementation at the Fermi National Laboratory, Illinois, U.S.A. The ICARUS T600 detector is made of four large Time Projection Chambers, installed in two separate containers of about 275 m 3 each. The detector uses liquid argon both as target and as active medium. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions and the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector was previously operated in Italy, at the INFN Gran Sasso Underground Laboratory (LNGS), in a three-year run on the CERN to LNGS Long Baseline Neutrino Beam. For its operation on the Booster and NuMI neutrino beams at Fermilab, for the search of sterile neutrinos and measurements of neutrino-argon cross sections, the detector was moved from Gran Sasso to CERN for the upgrades required for operation at shallow depth with high intensity neutrino beams. The liquid argon containers, the thermal insulation and all the cryogenic equipment have been completely re-designed and rebuilt, following the schemes of the previous installation in Gran Sasso. The detector and all the equipment have been transported to Fermilab, where they have been installed, tested and recently put into operation. The work described in this paper has been conducted as a joint responsibility of CERN and Fermilab with the supervision provided by the ICARUS Collaboration. Design, installation, testing, commissioning and operation are the result of a common effort of CERN, Fermilab and INFN groups.

Cryogenic detectors↗

Search for Electron Neutrinos in Multiple Topologies with the MicroBooNE Experiment

This note presents the status of the measurement of electron neutrinos from the Fermilab Booster Neutrino Beamline (BNB) with the MicroBooNE experiment. The analysis is aimed at investigating the nature of the low energy excess of electromagnetic activity observed by the MiniBooNE experiment. The $ν_e$ event selection relies on topological and calorimetric information to characterise particles produced in these interactions, leveraging the Pandora multi-algorithm reconstruction framework as well as custom particle identification and pattern recognition tools. Results presented in this note use 5.88 × 10 20 protons on target of data collected between 2015 and 2018. These include the performance of particle identification tools for $\mu/p$ and $e/\gamma$ separation, along with electromagnetic shower calibration with the largest sample of $\pi^0$ events measured on argon. Progress towards the completion of this analysis is shown through the measurement of high-energy charged-current $ν_e$ interactions and their kinematic distributions using both inclusive (1eX) and exclusive (1$e$0$p$0$\pi$ and 1$e$N$p$0$\pi$) channels. Measurements of charged-current $ν_µ$ interactions aimed at constraining flux and cross-section systematic uncertainties are also shown. We present the analysis’ preliminary sensitivity of an electron-like signal hypothesis to the MiniBooNE excess which includes flux, cross-section, and detector systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the MicroBooNE Low Energy Excess Search

MicroBooNE is a neutrino experiment that utilizes a liquid argon time projection chamber (LArTPC) located on-axis in the Booster Neutrino Beam (BNB) at Fermilab. One of the experiment’s main goals is to search for excess low-energy electromagnetic-like events as seen by the MiniBooNE experiment, located just downstream of MicroBooNE in the BNB. As MicroBooNE nears the completion of its first single-electron-like and single-photon-like searches, these proceedings present the status of MicroBooNE's low-energy excess search as of early summer 2020. In addition to presenting an overview of the approach to these analyses, we showcase results from $\pi^0$ calibrations and $e$/$\gamma$ separation, and sample results from sidebands aimed at validating the analysis' progress outside the low-energy signal region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Search for Heavy Neutral Leptons Decaying to Electron-Positron Pairs and Neutral Pions in the MicroBooNE Detector

This thesis presents a search for heavy neutral leptons (HNLs) decaying inside the MicroBooNE detector. The MicroBooNE detector is a liquid-argon time projection chamber located at Fermilab that receives flux from two neutrino beams; the booster neutrino beam (BNB) and the neutrinos at the main injector (NuMI) beam. The search uses data taken when the NuMI beam was on, with a total exposure of $7.01\times10^{20}$ protons on target. HNLs would be produced in kaon decays, and the source of HNLs targeted in this search is kaons decaying at rest in the NuMI hadron absorber. The kinematics of the HNLs produced in this way allow their decays to be distinguished from the majority of beam-neutrino interactions and cosmic-ray activity that constitute the background. Two HNL decay channels are studied, $\nu$\ee and \vpi. Boosted decision trees (BDTs) are trained to separate the simulated HNL decays from the expected background events. The BDT score distributions are used to calculate upper limits on the mixing angle \umusq in the mass range $10\le m_{\rm HNL}\le 245$~MeV. This is the first direct search for HNL decays to the \vpi channel, and the limits provide the most stringent constraints on \umusq in the mass range $35<\mhnl<175$~MeV.

43 PARTICLE ACCELERATORS↗

Preshot Report for Carbonara: Dynamics of a Boron Carbide Sandwich

The main purpose of the Carbonara experiment is to provide much-needed data to inform physics modeling of boron carbide (B 4 C) subjected to a sweeping high explosive (HE) detonation. The proposed experiment will include three separate shots, each employing a rectangular slab of HE (4” × 3” × 1”) sandwiched between two wedges of B 4 C, see Fig.1. In each case the top B 4 C wedge tapers from a height of 2.5 cm to 0.5 cm, while the bottom wedge tapers from 1.5 cm to 0.5 cm. The wedges are 4” in the direction of the proton beam, and 3” in the direction transverse to the beam. Three shots are currently planned, each one using a different HE: PBX 9501, PBX 9502, and PBX 9701. The HE will be initiated using a line wave generator (LWG) to preserve planar symmetry, in conjunction with a Comp. B booster to smooth out the profile for the initial condition on the main charge and to aid in initiation of the PBX 9502 shot. In each case the booster spans the entire length and height of the main HE slab and extends 0.5” in toward the LWG.

36 MATERIALS SCIENCE↗

Track vs Shower Discrimination in the Event Reconstruction of the ICARUS Experiment

The ICARUS collaboration has employed the 760-ton T600 liquid argon TPC detector in a successful three-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. The detector commissioning phase lasted until June 2022, then ICARUS moved to data taking for neutrino oscillation physics collecting events from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis. The initial experiment goals are to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment, perform measurements of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. Then, ICARUS will jointly search for evidence of sterile neutrinos with the Short-Baseline Near Detector (SBND). In this contribution, we discuss recent changes to the standard TPC event reconstruction that uses Pandora, a pattern recognition software common to liquid argon-based detectors. In particular, we performed a new training of the Boosted Decision Tree (BDT) employed to separate track-like and shower-like reconstructed particles using Monte Carlo simulations of neutrino events from BNB in ICARUS. We compare the discrimination capabilities of the old and new BDT training and discuss further improvements of this algorithm.

43 PARTICLE ACCELERATORS↗

2,3-Butanediol recovery from fermentation broth using membrane pertraction

2,3-Butanediol (BDO) has gained immense interest for use as a platform chemical in the production of many important chemicals such as synthetic rubber, plasticizer, and octane boosters. Using BDO as a precursor for sustainable aviation fuel production may significantly reduce the carbon footprint of the airline industry. However, recovery of BDO is challenging due to its relatively low concentration (∼10 wt %) in fermentation broth and its high affinity for water. In this work, we developed a membrane pertraction process for BDO recovery from biomass derived fermentation broth. Different organic solvents such as hexanol and oleyl alcohol were investigated. With traditional solvent extraction, hexanol required a solvent to feed ratio of 10 to recover >90 % BDO, and oleyl alcohol could recover 35 % of BDO at the same ratio. BDO recovery of >90 % was demonstrated with pertraction; a BDO extraction rate of 15 g 1 m −2 h −1 was achieved using hexanol, and an extraction rate of 10 g 1 m −2 h −1 was achieved using oleyl alcohol. Impurities commonly found in fermentation broth did not affect the separation performance of the pertraction process. In conclusion, this work demonstrates pertraction as a low-footprint, scalable method for recovery of high-purity BDO from fermentation broth.

2,3 butanediol↗