Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bridge Plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗

An Evaluation of the Carbon Sequestration Potential of the Cambro-Ordovician Strata of the Illinois and Michigan Basins. Part 1. Evaluation of Phase 2 CO 2 Injection Testing in the Deep Saline Gunter Sandstone Reservoir (Cambro-Ordovician Knox Group), Marvin Blan No. 1 Hancock County, Kentucky Part 2. Time-lapse Three-Dimensional Vertical Seismic Profile (3D-VSP) of Sequestration Target Interval with Injected Fluids

Part 1 of this report focuses on results of the western Kentucky carbon storage test, and provides a basis for evaluating injection and storage of supercritical CO 2 in Cambro-Ordovician carbonate reservoirs throughout the U.S. Midcontinent. This test demonstrated that the Cambro- Ordovician Knox Group, including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite in stratigraphic succession from shallowest to deepest, had reservoir properties suitable for supercritical CO 2 storage in a deep saline reservoir hosted in carbonate rocks, and that strata with properties sufficient for long-term confinement of supercritical CO 2 were present in the deep subsurface. Injection testing with brine and CO 2 was completed in two phases. The first phase, a joint project by the Kentucky Geological Survey and the Western Kentucky Carbon Storage Foundation, drilled the Marvin Blan No. 1 carbon storage research well and tested the entire Knox Group section in the open borehole – including the Beekmantown Dolomite, Gunter Sandstone, and Copper Ridge Dolomite – at 1152–2255 m, below casing cemented at 1116 m. During Phase 1 injection testing, most of the 297 tonnes of supercritical CO 2 was displaced into porous and permeable sections of the lowermost Beekmantown below 1463 m and Gunter. The wellbore was then temporarily abandoned with a retrievable bridge plug in casing at 1105 m and two downhole pressure-temperature monitoring gauges below the bridge plug pending subsequent testing. Pressure and temperature data were recorded every minute for slightly more than a year, providing a unique record of subsurface reservoir conditions in the Knox. In contrast, Phase 2 testing, this study, tested a mechanically-isolated dolomitic-sandstone interval in the Gunter.

54 ENVIRONMENTAL SCIENCES↗

Formed-in-place Ceramic Systems for Sealing and Flow Control in Geothermal Applications

Conventional oil and gas tools are frequently unsuitable for downhole applications in geothermal wells, largely due to uncased well configurations and their extreme thermal/chemical fluid conditions. Consequently, relatively common O&G tools like bridge plugs and sand control screens are difficult or at times impossible to implement in geothermal wells. In commercial oil and gas, thermite-based tools are being developed for intervention and decommissioning applications, and gaining field experience and credibility. We are developing and testing such systems for geothermal applications, with the objective of forming ceramic sealing and flow control features in-situ. The process uses self-propagating thermite reactions, in which a metal is combined with an oxidizer to release significant amounts of energy in a controlled, non-explosive manner. These solid phase reactions can be engineered to generate ceramic products with specific physical and flow characteristics. We are developing and testing formulations and wireline deployment tools which yield low to high permeability as needed, and preferentially expand to fill boreholes in both large diameter and slimhole wells. Near term applications are bridge plugs for P&A operations, screens for sand control and borehole stabilization, and lost circulation control during drilling. Laboratory tests have demonstrated the ability to form these products under high temperature and pressure conditions. Field tests are in planning to demonstrate the full-scale performance of these tools. This paper will present the status and results of this demonstration project, in its first year of advanced development for the DOE geothermal technologies program. New developments utilizing thermite tools in the HP/HT oil and gas domain will also be highlighted, particularly those which may have utility in geothermal applications.

02 PETROLEUM↗

Utah FORGE 1-2409: PetroQuip Energy Services Zonal Isolation Solution for Geothermal Wells - 2024 Annual Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells by PetroQuip Energy Services, presented by Robert Coon. This video slide presentation discusses the proposed design and development of a multi-stage system consisting of an Open-Hole Packer (OHP), a Locking Bridge Plug (LBP), and a corresponding Locating Profile (LP). This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

Expanding thermite reactions for downhole applications

Methods and apparatus for forming platforms and flow control features in underground wells is described, using modified thermite reactions to form a ceramic plug in place. The reactive package is engineered to expand laterally, filling the well, and may be used to form a ceramic bridge plug, porous ceramic screen sections, or mitigate lost circulation of drilling fluids. These objectives are achieved through the design of the reactive package and through use of carefully chosen reaction additives that control the molten product rheology, solidification temperature, and pore generations and sustainment.

Lowry, William Edward↗

Basic Data Report for Well Plugging and Abandonment and Reconfiguration Activities for Fiscal Year 2005 (Rev. 1)

The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy (DOE) facility disposing of transuranic and mixed waste under a permit issued by the New Mexico Environment Department (NMED). WIPP is located 26 miles east of Carlsbad, New Mexico, in eastern Eddy County (Figure 1). Disposal panels are mined in the Permian Salado Formation at a depth of about 2,150 feet below ground surface (bgs). Over the years a number of groundwater monitor wells have been installed for site characterization and to monitor temporal and spatial changes in groundwater elevation and chemistry at WIPP. Many of the wells in the fiscal year (FY) 2005 program were selected for plugging and abandonment (P&A) due to redundancy. In other words, the well pads have multiple wells that monitor the Culebra ("Culebra") Member of the Rustler Formation when only one is necessary. These multi-well locations are a relic of various aquifer testing programs associated with the site characterization of WIPP. Additionally, the multi-well locations had wells that were completed in both the Culebra and the Magenta ("Magenta") Members of the Rustler Formation for dual monitoring of these intervals. The intervals were separated by inflatable packers used as bridge plugs, and over the years these packers have aged and their integrity compromised. For these wells, the packers were removed and the wells were converted to Magenta-only monitor wells. The FY 2005 program was initiated on March 31, 2005, and concluded on July 16, 2005. The FY 2005 program initially included 25 wells requiring workover (P&A, Magenta reconfiguration, cleaning and keeping). During the process, the U.S. Bureau of Land Management (BLM) requested transfer of two wells (H-7c and H-8c) to their ownership for future livestock watering. These wells were transferred to the BLM through execution of Form wr-03, Declaration of Owner of Underground Water Rights, between the New Mexico Office of the State Engineer (NMOSE), the BLM, and the DOE Carlsbad Field Office (CBFO). One well (H-2b2) was cleaned and retained as a Culebra monitor well for continued use. One well (H-3d) was converted to a shallow well to monitor the formational contact between the Dewey Lake Redbeds Formation and the Santa Rosa Formation in support of the DP-831 discharge permit monitoring program. Nine dual-completion wells were reconfigured as Magenta-only monitor wells, and 12 wells were plugged and abandoned permanently. This report presents the summary in the same order that the wells were worked in the field.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utah FORGE: Well 58-32 Stimulation Conference Paper and Data

The U.S. Department of Energy’s (U.S. DOE) Frontier Observatory for Research in Geothermal Energy (FORGE) is a field laboratory that provides a unique opportunity to develop and test new technologies for characterizing, creating and sustaining Enhanced Geothermal Systems (EGS) in a controlled environment. In 2018, the U.S. DOE selected a site in south-central Utah for the FORGE laboratory. Numerous geoscientific studies have been conducted in the region since the 1970s in support of geothermal development at Roosevelt Hot Springs. A vertical scientific well, 58-32, was drilled and tested to a depth of 2290 m (7515 ft) GL in 2017 on the FORGE site to provide additional characterization of the reservoir rocks. The well encountered a conductive thermal regime and a bottom hole temperature of 199degC (390degF). More than 2000 natural fractures were identified, but measured permeabilities are low, less than 30 micro-darcies. Induced fractures indicate that the maximum horizontal stress trends NNE-SSW, consistent with geologic and well observations from the surrounding area. Approximately 45 m (147 ft) at the base of the well was left uncased. A maximum wellhead pressure of 27.6 MPa (4000 psig) at an injection rate of ~1431 L/min (~9 bpm) was measured during stimulation testing in September 2017. Conventional diagnostic evaluations of the data suggest that hydraulic fracturing and shearing occurred. Estimates of the stress gradient for delta_h_min range from of 16.7 to 17.6 kPa/m (0.74 to 0.78 psi/ft). A gradient of 25.6 kPa/m (1.13psi/ft) was calculated for delta_V. In 2019, the 2017 open-hole stimulation in well 58-32 was repeated with injection rates up to 2385 L/min (15 bpm). Two additional stimulations were conducted in the cased portion of the well; one to stimulate critically stressed fractures and the second to test noncritically stressed fractures. Breakdown of the zone spanning critically-stressed fractures occurred at a surface pressure of approximately 29.0 MPa (4200 psig). Although stimulation of the noncritically stressed fractures was interrupted by failure of the bridge plug beneath the perforated interval, micro-seismic data suggests stimulation of the fractures may have been initiated at a surface pressure of 45.5 MPa (6600 psig). These stimulation results support the conclusion the Mineral Mountains granitoid is an appropriate host for EGS development. Micro-seismicity was monitored during the stimulations using surface and downhole instrumentation. Five seismometers and a nodal array of 150 seismic sensors were deployed on the surface. A Distributed Acoustic Sensing (DAS) cable and a string of 12 geophones were deployed in well 78-32, drilled to a depth of 998 m (3274 ft) GL. A broadband sensor and a high-temperature geophone were deployed in well 68-32, drilled to a depth of 303 m (994 ft) GL. More than 420 micro-seismic events were detected by the geophone string. Other instruments detected fewer events.

15 GEOTHERMAL ENERGY↗

High Fidelity Modeling of WELL58-32 DFITS

Between 2017 and 2019, a series of injection tests were performed at pilot vertical well 58-32 at the Utah FORGE site. These injection activities were conducted in three distinct zones, isolated with packers and bridge plugs during the tests. Zone 1 consists of an open-hole section at the toe of the well, whereas Zones 2 and 3 are three-meter long cased and perforated sections. Several injection cycles were conducted in each zone. A detailed description of the geology of the FORGE site, of well 58-32 and of all injection cycles can be found in (Xing et al., 2020). The injection cycles included Diagnostic Fracture Injection Tests (DFITs). DFITs comprise two primary stages: an injection (pump-in) phase, where controlled fluid injection is employed to create a small hydraulic fracture in the surrounding rock, followed by a shut-in phase, where injection ceases, allowing observation of the formation’s pressure response. Utilizing methodologies such as the G-function analysis, DFITs provide valuable insights, including fracture closure pressure and the Instantaneous Shut-in Pressure (ISIP) and can be employed to estimate the minimum horizontal stress.

42 ENGINEERING↗

Reference design and operations for deep borehole disposal of high-level radioactive waste.

A reference design and operational procedures for the disposal of high-level radioactive waste in deep boreholes have been developed and documented. The design and operations are feasible with currently available technology and meet existing safety and anticipated regulatory requirements. Objectives of the reference design include providing a baseline for more detailed technical analyses of system performance and serving as a basis for comparing design alternatives. Numerous factors suggest that deep borehole disposal of high-level radioactive waste is inherently safe. Several lines of evidence indicate that groundwater at depths of several kilometers in continental crystalline basement rocks has long residence times and low velocity. High salinity fluids have limited potential for vertical flow because of density stratification and prevent colloidal transport of radionuclides. Geochemically reducing conditions in the deep subsurface limit the solubility and enhance the retardation of key radionuclides. A non-technical advantage that the deep borehole concept may offer over a repository concept is that of facilitating incremental construction and loading at multiple perhaps regional locations. The disposal borehole would be drilled to a depth of 5,000 m using a telescoping design and would be logged and tested prior to waste emplacement. Waste canisters would be constructed of carbon steel, sealed by welds, and connected into canister strings with high-strength connections. Waste canister strings of about 200 m length would be emplaced in the lower 2,000 m of the fully cased borehole and be separated by bridge and cement plugs. Sealing of the upper part of the borehole would be done with a series of compacted bentonite seals, cement plugs, cement seals, cement plus crushed rock backfill, and bridge plugs. Elements of the reference design meet technical requirements defined in the study. Testing and operational safety assurance requirements are also defined. Overall, the results of the reference design development and the cost analysis support the technical feasibility of the deep borehole disposal concept for high-level radioactive waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utah FORGE 1-2409: Zonal Isolation Solution for Geothermal Wells - Workshop Presentation

This is a presentation on the Zonal Isolation Solution for Geothermal Wells project by PetroQuip Energy Services, presented by VP of operations Robert Coon. The project's objective was to design and develop a multi-stage system for zonally isolating fluids inside and outside of geothermal well casings. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 7, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size

Geothermal formations often contain extensive fracture networks. These fracture networks contribute to the significant loss of drilling fluids during geothermal drilling. Multiple loss circulation materials (LCM) such as fiber, granules, and pills have been proposed to tackle this problem but with only limited success. Recent advances in materials science have led to the development of thermoset shape memory polymers (SMP) to address the lost circulation problem. In this paper, we evaluate a thermoset SMP performance in sealing near wellbore fractures of different sizes in geothermal wells. The SMP performance was assessed using granite disks and cylindrical granite cores having fracture sizes of 1000 μm and 3000 μm. A static filtration test was performed using cedar fiber, CaCO 3 , and SMP. Results showed cedar fiber performed better than the CaCO 3 ., reducing fluid loss by 89% and improving sealing pressure by 200 psi. A novel dynamic testing unit that allows for high-temperature testing under flowing conditions was used in this study. The analysis showed that 3% by weight SMP and fiber blends could bridge and plug the 1000 μm fracture. For a larger fracture of 3000 μm width, there was a need to increase the weight concentration of the SMP to 6% to plug the fracture opening effectively. We showed the influence of key parameters such as the type of LCM, concentration, and particle size distribution in optimizing the performance of drilling fluid loss treatment.

02 PETROLEUM↗

Utah FORGE: Well 58-32 Stimulation Data

Pressure, temperature, and flow data from open-hole, upper perforation, and lower perforation well stimulations gathered from various tools collected at well 58-32 during phase 2C.

15 GEOTHERMAL ENERGY↗

Simulators for Safer Shipping

Each year one ship out of every five afloat collides with another vessel, rams a dock, or runs a ground. CAORF (Computer Aided Operations Research Facility), designed and built by Sperry Rand Corporation, incorporates technology developed in a wide variety of aerospace simulation and technical training programs. CAORF can be set up to duplicate the exact handling qualities of any vessel under various conditions of wind, tide and current. Currently a dozen different ships can be "plugged in." Bridge instrumentation is typical of modern shipboard equipment including radar, internal and external c.ommunications and new collision avoidance systems. From repetitive operation of simulated ships, MarAd is building a valuable data base for improving marine safety.

Source record↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Low Greenhouse Gas (GHG) Vehicle Technologies Research, Development, Demonstration and Deployment Topic 5 Natural Gas Engine Enabling Technologies

A 10 liter natural gas engine has been developed with significant improvements in efficiency while maintaining ultra low NOx emissions and meeting all other EPA criteria emissions limits. This was accomplished through design and analysis of performance components specifically for operation with natural gas in contrast to current production engines which are a minimally modified diesel engine that retain most diesel design features including a flat deck swirl head. The architecture developed here includes a pent roof cylinder head with tumble charge motion and cooling passages specifically optimized for effective cooling around the spark plug and valve bridges. Also in contrast to current production natural gas engines, EGR was not used, in part to avoid the initial cost and warranty expense associated with EGR systems, but also for performance benefits of faster combustion, reduced risk of misfire and high open cycle efficiency due to the turbocharger’s ability to extract energy from the high temperature exhaust. The exhaust manifold uses high temperature material and thermal mechanical fatigue analysis was completed to ensure the ability to withstand high exhaust temperatures without EGR. Other features include dual overhead cam with late intake valve closing Miller cycle and 14:1 compression ratio steel pistons. Low NOx emissions are achieved with stoichiometric combustion and application of a close coupled plus underfloor three way catalysts. The program target of peak brake thermal efficiency of 42% has been demonstrated along with bsNOx of 0.02 g/hp-hr over HD-FTP and RMCSET emissions cycles.

99 GENERAL AND MISCELLANEOUS↗

Noise of Internally Mixed Exhaust Systems With External Plug For Supersonic Transport Applications

Internally mixed exhaust systems produce more noise than would be expected from an equivalent fully mixed flow. This ‘excess noise’ has never been fully explained and has not been researched recently as it is not as much of a problem for high bypass-ratio exhaust systems. Commercial supersonic vehicles, however, will use more moderate bypass ratio engines. Their exhaust systems will also likely feature external plugs to improve boat tail angle for cruise performance. Thus the problem of excess noise will need to be addressed along with the impacts of having an external plug. Recently, acoustic tests of dual-stream jet flows from both internal and external plug nozzles have been conducted. Measurements of noise from flows with an axisymmetric splitter and lobed forced mixer were made. These measurements show the baseline ‘excess noise’ previously found in forced mixer exhaust systems, and show how this noise source differs depending upon the plug geometry. Background-oriented schlieren measurements acquired simultaneously document the differences in shock structures over the transonic flow regime tested. The far-field acoustic measurements indicate that an external plug can slightly reduce the mixing noise of the jet plume when the flow is completely mixed, e.g. when the core and bypass streams have the same temperature and the flow is a single-stream jet. However, when the flow is not fully mixed, e.g. the usual case of an internally mixed exhaust system, the plug seems to amplify the ‘excess noise’ associated with the mixer. This additional noise source presents a challenge for nozzle designers wanting to use internally mixed exhaust systems with external plug nozzles.

Jet noise↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗