At least 19 records

Improvements to neutron detection of Pu in solvent for an aqueous buffer tank, magnox reprocessing plant, Sellafield - 14216

The PP Active Feed Tank (PPAFT) is a buffer tank that is not safe by geometry and which is located between the Medium Active (MA) and Plutonium Purification (PP) cycles of the chemical separation process in the Magnox Reprocessing Plant. The PPAFT receives Pu nitrate in acid which has been conditioned ready for the extraction of Pu with TBP/OK (tri-butyl phosphate in kerosene) solvent in the PP Cycle. The criticality safety case for the PPAFT recognises that during both normal operations and potential maloperations solvent which is dissolved (TBP which is present in solution but can be released upon a change in acidity) and entrained (TBP/OK physically carried over but not in solution) will accumulate in the PPAFT. The only practicable route out for Pu in solvent in the PPAFT is the normal process route out from the base of the PPAFT to the PP cycle through intermediate vacuum lift and feed vessels. However, the dished end base of the PPAFT and the intermediate vacuum lift and feed vessels are of particularly challenging geometry. There are five neutron monitors placed around the PPAFT for the detection of Pu in solvent. The original design intent of the neutron detection system was that any single monitor should be able to reveal an accumulation of Pu in solvent before it would potentially be unsafe if fed downstream. However, over time there have been changes to the fuel feed and chemical process of the plant which have had the potential to affect the performance of the neutron monitoring system. The ability of the neutron monitoring system to function to its original intent was questioned. Work has recently been carried out to investigate the capabilities of the PPAFT neutron monitoring system for current plant conditions and to identify potential improvements while making best use of the existing neutron monitors. It was found that moving a neutron monitor from the side to the top of the PPAFT and adding alarms based on the ratio of signals from multiple neutron detectors would be effective in improving detection of Pu in solvent. This paper describes the challenges involved in detecting thin layers of Pu in solvent using neutron monitors, discusses the improvements made to the PPAFT neutron monitors and details the combination of real plant data and modelling with the shielding code MCBEND used to provide confidence in the enhanced neutron monitoring system. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assuring pulsation-free flow in a directly pressurized fuel delivery at a retail hydrogen station

When a retail hydrogen station operates using booster compressors to directly fill cars, a need for an additional high-pressure buffer volume is present, in order to mitigate potential pressure pulsations in the system. Looking at the case of the Cal State LA Hydrogen Fueling Station, pulsations with a magnitude up to 6.7 MPa were observed with no buffer volume during 70 MPa fueling. Thus the focus was placed on determining the minimum buffer volume required to ensure pulsation free operation to the entire downstream system (booster compressors, piping and the vehicle hydrogen hardware). A mathematical model of volumes involved has been developed and compared to experimental measurements. The station configuration allows isolating one or more of the four high-pressure buffer tanks with which the station was upgraded to reduce pulsations. Each tank has a volume of 0.05 m 3 . A relatively simple model developed shows a strong correlation with the experiments in determining the maximum pulse and the minimum additional high-pressure buffer volume. Effectively, one buffer tank would have provided a proper operation of the station by keeping the pressure pulsation magnitude under 0.2 MPa.

08 HYDROGEN↗

Experimental Comparison of Hydrogen Refueling with Directly Pressurized vs. Cascade Method

This paper presents a comparative analysis of two hydrogen station configurations during the refueling process: the conventional “directly pressurized refueling process” and the innovative “cascade refueling process.” The objective of the cascade process is to refuel vehicles without the need for booster compressors. The experiments were conducted at the Hydrogen Research and Fueling Facility located at California State University, Los Angeles. In the cascade refueling process, the facility buffer tanks were utilized as high-pressure storage, enabling the refueling operation. Three different scenarios were tested: one involving the cascade refueling process and two involving compressor-driven refueling processes. On average, each refueling event delivered 1.6 kg of hydrogen. Although the cascade refueling process using the high-pressure buffer tanks did not achieve the pressure target, it resulted in a notable improvement in the nozzle outlet temperature trend, reducing it by approximately 8 °C. Moreover, the overall hydrogen chiller load for the two directly pressurized refuelings was 66 Wh/kg and 62 Wh/kg, respectively, whereas the cascading process only required 55 Wh/kg. This represents a 20% and 12% reduction in energy consumption compared to the scenarios involving booster compressors during fueling. The observed refueling range of 150–350 bar showed that the cascade process consistently required 12–20% less energy for hydrogen chilling. Additionally, the nozzle outlet temperature demonstrated an approximate 8 °C improvement within this pressure range. These findings indicate that further improvements can be expected in the high-pressure region, specifically above 350 bar. This research suggests the potential for significant improvements in the high-pressure range, emphasizing the viability of the cascade refueling process as a promising alternative to the direct compression approach.

08 HYDROGEN↗

Hydrogen losses in fueling station operation

This paper describes an engineering approach for hydrogen accounting from production to dispensing at Cal State Los Angeles Hydrogen Research and Fueling Facility, equipped with an electrolyzer for on-site production. Particularly, the accounting process has been carried out by taking an in-depth look at current practices and databases, and its analysis has been based on data from quarterly reports of hydrogen production and dispensing related parameters and from its data acquisition system. It is described how the station addressed this analysis investigating several station areas. Following there is an assessment of the possible critical points, flanked by considerations, calculations, mathematical modeling and analysis of the database. The analysis led to a marked improvement on the station operation know-how. For most of the analyzed months the current average percentage of losses was found to be between 2 and 10%, whereas before it was between 30 and 35%. This current range of percentage (2–10)% includes all experiments done, defueling the buffer tanks, rebooting the dispenser, venting the lines, the uncertainty of the mass flow meter inside the dispenser (±5%) and the inherent uncertainty of Faraday’s law for hydrogen production estimate. Among all areas analyzed, maintenance activities revealed themselves as the most critical ones, leading to data mismatching in hydrogen accounting. The paper aims also to provide a guideline with recommended practices based on our experience, deduced for station operators and builders, including several steps for leakage monitoring, prevention, and troubleshooting.

08 HYDROGEN↗

Automated electrical demand peak leveling in a manufacturing facility with short term energy storage for smart grid participation

Demand side management of energy is a vital function in the smart grid that allows for greater integration of renewable energy resources, and is facilitated with economic incentives in energy and demand pricing schedules. Manufacturing systems can take advantage of these incentives to reduce their energy costs through active energy management. This paper is a simulation analysis on the implementation of a novel algorithm that levelizes the maximum power load of an industrial bakery that operates under an on-peak demand price structure. The algorithm takes advantage of an untapped thermal energy storage resource in the facility, a chilled glycol buffer tank, to level the short intra-day power oscillations that the facility experiences. One of the key advantages of the algorithm is that it does not require precise demand forecasting or complex control algorithms, such as model predictive control. Even with substantial error in peak power estimates (5%), the algorithm is expected to result in at least a 2% peak reduction. Under ideal prediction, the algorithm reduces the on-peak facility power maximum by 7.3% of the possible 9.0% reduction the storage can provide. Further, the algorithm uses very few facility specific inputs, and can readily be adapted for any facility with short intra-day oscillatory power profiles and untapped storage capacity. The key insight of the paper is the employment of a novel algorithm to leverage untapped energy storage in manufacturing facilities to transform them into smart grid participants with no major capital investment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Thermal Storage on the Emissions and Efficiency Performance of a Wood Pellet-Fired Residential Boiler

Wood pellet boilers for residential heating applications offer the promise of low emissions, high efficiency, and automatic operation. However, when operated in the field, these units operate often at very low loads causing them to cycle. In this study, the performance of a 25-kW modern pellet boiler under emulated field conditions and fixed nominal loads of 15% and 100% has been studied in a lab—with and without a buffer tank. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements under EPA Methods 28 WHH and 28 WHH PTS. Results show that increasing the amount of thermal storage used decreases cycling rates leading to decreased emissions and increased efficiency. Without thermal storage, integrated efficiency over a 15% load test period was 57%, compared to 74% when thermal storage was used. Particulate emissions were 180 mg/MJ and 64 mg/MJ for the 15% load case without and with thermal storage, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Development of a Hydrogen Energy System as a Grid Frequency Management Tool

The Hawai‘i Natural Energy Institute (HNEI) is conducting research to assess the technical potential of using an electrolyzer-based hydrogen (H2) production and storage system as a grid demand response tool using battery data from a 200 MW grid to show the kind of response required. The hydrogen produced by the electrolyzer is used for transportation. A 65 kg/day hydrogen energy system (HES) consisting of a PEM electrolyzer, 35 bar buffer tank, 450 bar compressor, and associated chiller systems was purchased and installed at the Hawaii Natural Energy Laboratory Hawaii Authority (NELHA) to demonstrate long-term durability of the electrolyzer under cyclic operation required for frequency regulation on an island grid system. The excess hydrogen was stored for use by three fuel-cell buses to be operated at Hawai‘i Volcanoes National Park (HAVO) and by the County of Hawai‘i Mass Transit Agency (MTA). This paper describes the site selection and equipment commissioning, plus a comprehensive test plan that was developed to characterize the performance and durability of the electrolyzer under dynamic load conditions. The controls were modified for the operating envelope and dynamic limits of the electrolyzer. While the data showed these modifications significantly improved the system response time, it is not fast enough to match a BESS response time for grid frequency management. The electrolyzer can only be used for slower acting changes (1 to 0.5 Hz). A potential solution is to design an electrolyzer/BESS hybrid system and develop a modeling program to find the optimum mix of battery and electrolyzer to provide the maximum grid regulation services at minimum cost.

08 HYDROGEN↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

14 SOLAR ENERGY↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013–2014 Evaluation

The Florida Solar Energy Center (FSEC) completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). The evaluation studied the performance of five hot water systems (HWS) plus a reference baseline system for each fuel, (i.e., electric and natural gas). Electric HWS consisted of two residential electric heat pump water heaters (HPWHs, 60 and 80 gallons), a solar thermal system using a polymer absorber (glazed) collector with 80-gallon storage and a duplicate 50-gallon standard electric water heater with added cap and wrap insulation. Baseline performance data were collected from a standard 50-gallon electric water heater of minimum code efficiency to compare energy savings. Similarly, a standard 40-gallon upright vented natural gas water heater served as baseline for the natural gas fuel category. The latter, having a larger jacket diameter [18 in., with an energy factor (EF) of 0.62] with increased insulation, replaced a former baseline (17 in. diameter, EF = 0.59) that served during three previous testing rotations (2009–2013). A high-efficiency, condensing natural gas hybrid water heater with 27-gallon buffered tank was also tested and compared against the gas baseline. All systems underwent testing simultaneously side-by-side under the criteria specified elsewhere in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US. When operating properly, the combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater is a viable option for high-efficiency residential space heating in cold climates. Based on previous research efforts, however, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency. Furthermore, guidance on proper design and commissioning for heating contractors and energy consultants is hard to find and is not comprehensive. Through modeling and monitoring, CARB sought to determine the optimal combination(s) of components - pumps, high efficiency heat sources, plumbing configurations and controls - that result in the highest overall efficiency for a hydronic system when baseboard convectors are used as the heat emitter. The impact of variable-speed pumps on energy use and system performance was also investigated along with the effects of various control strategies and the introduction of thermal mass.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York (Fact Sheet)

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic System Performance in Residential Applications

Even though new homes constructed with hydronic heat comprise only 3% of the market (US Census Bureau 2009), of the 115 million existing homes in the United States, almost 14 million of those homes (11%) are heated with steam or hot water systems according to 2009 US Census data. Therefore, improvements in hydronic system performance could result in significant energy savings in the US.

AFUE↗

Technology Solutions Case Study: Optimizing Hydronic System Performance in Residential Applications, Ithaca, New York

Condensing boiler technology has been around for many years and has proven to be a durable, reliable method of heating. Based on previous research efforts, however, it is apparent that these types of systems are not designed and installed to achieve maximum efficiency. For example, in order to protect their equipment in the field, manufacturers of low-mass condensing boilers typically recommend design strategies and components that ensure steady, high flow rates through the heat exchangers, such as primary-secondary piping, which ultimately result in decreased efficiency. There is also a significant lack of information for contractors on how to configure these systems to optimize overall efficiency. In response to these findings, researchers from Building America team Consortium for Advanced Residential Buildings worked with industry partners to develop hydronic system designs that would address these issues and result in higher overall system efficiencies and improved response times.

AFUE↗

Study of Epoxy Sealant Layer for Use in Tank Bottom Refurbishment for the DOE EM Tank Waste R&D Program

This study addresses the DOE National Laboratory Program on Hanford Tank Waste Cleanup Research and Development, focusing on tank waste retrieval, transport, and closure. Millions of gallons of high-level waste are stored in the double shell tanks (DSTs) at Hanford site. The waste is stored in the primary tank, while the secondary shell acts as a buffer between the primary tank and environment. The DSTs’ bottoms could be corroded due to the corrosive waste properties and contents. Therefore, they are being emptied, and refurbishment is needed before waste storage continues. SRNL addresses the refurbishment of still operational DSTs bottoms with a two-layer refurbishment approach. We propose that the bottom layer consists of a high-density cementitious material to shield the epoxy top layer from radioactive residuals, while the top layer serves as an epoxy sealant. This work focuses on the experimental evaluation on the formulation and testing of the epoxy layer.

Blue, Kareen [Savannah River National Laboratory (↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗