Hygric Redistribution in Insulated Assemblies: Retrofitting Residential Envelopes Without Creating Moisture Issues

This research report was prepared by the Building Science Corporation Building America Research Team as part of the Energy Efficient Housing Research Partnerships project. The project title is Hygric Redistribution in Insulated Assemblies. The exterior retrofit of frame assemblies can be risky when impermeable insulating sheathings of relatively low thermal resistance are used. For example, basic hygrothermal analysis demonstrates that removing the existing cladding and installing a board foam insulation with low vapor permeance (such as ½-in. foil faced rigid insulation) directly over the sheathing membrane under a replacement cladding (such as vinyl siding) is likely to cause moisture problems in cold climates. One such problem is known as a “cold sided vapor barrier.” Tens of thousands of such retrofit and renovation projects have been completed, however, without apparent problems. There is also a perception that when water is intentionally drained in a drainage cavity between exterior insulation and the existing structure following an energy retrofit, moisture-related durability concerns exist for the sheathing and wood structure. This experimental program includes a literature review of previous research, laboratory testing programs, and an analysis of full-scale test wall performance in the U.S. Department of Energy’s climate zone 4C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture and Structural Analysis for High Performance Hybrid Wall Assemblies

This report describes the work conducted by the Building Science Corporation (BSC) Building America Research Team's 'Energy Efficient Housing Research Partnerships' project. Based on past experience in the Building America program, they have found that combinations of materials and approaches—in other words, systems—usually provide optimum performance. No single manufacturer typically provides all of the components for an assembly, nor has the specific understanding of all the individual components necessary for optimum performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations, Inc.: Partnering To Build Net-Zero Energy Houses in Massachusetts

Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ("Devens"), The Homes at Easthampton Meadow ("Easthampton") and Phase II of the Coppersmith Way Development ("Townsend"). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductless air source heat pump systems ("mini-splits"); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

This report describes a research study that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance homes in a hot-humid climate. The purpose of this research project was to observe and compare the humidity control performance. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses; homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family, new construction homes in New Orleans, LA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ('Devens'), The Homes at Easthampton Meadow ('Easthampton') andPhase II of the Coppersmith Way Development ('Townsend'). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers to specific research questions for homes with high R double stud walls and high efficiency ductlessair source heat pump systems ('mini-splits'); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana (Fact Sheet)

This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Best Practices Case Study: Green Coast Enterprises - Project Home Again, New Orleans, LA

Case study about Green Coast Enterprises, who received design assistance and analysis from Building America team Building Science Corporation to build 100 homes for New Orleans families displaced by Hurricane Katrina. The homes incorporate a host of weather-resistant techniques: pier foundations, all borate pressure-treated lumber; hurricane strapping; moisture-resistant closed-cell spray foam insulation under the subfloor, in walls, and under the roof line to seal out moisture-laden air and glue the structure together to resist high winds; roof sheathing seams sealed with butyl-adhesive flashing tape; and a fully adhered roofing membrane over eaves and gable ends.

Building America↗

Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment

BSC↗

New Whole-House Solutions Case Study: Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. In 2010, the City of Wyandotte, Michigan, started construction to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ×6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

BSC↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heatingequipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit

The Building Science Corporation seeks to further the energy efficiency market for retrofit projects in the New England area by supporting projects that are based on solid building science fundamentals and verified implementation. The Building Science Corporation has been working with Byggmeister, a partner on its Building America Program team, on retrofit projects. Byggmeister is a Boston-area design-build firm that specializes in energy efficient retrofits and new construction. The DEAP (Duclos, Eldrenkamp and Panish) Energy Group, which is associated with Byggmeister, conducts energy analysis for projects during design and performs monitoring after completion. With the high exposure of energy efficiency and retrofit terminology currently being used in the general media, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. Concrete data from specific projects can close the gap between “hype” and reality. This technical report describes a deep energy retrofit project for a two-family wood framed home located in Belmont, Massachusetts. Built in the 1920s, this home is referred to in this report as the “Belmont Two-Family.” The report examines the retrofit measures for the enclosure and mechanical systems and the decision making that took place during project planning. Because the retrofit project is complete, projected and actual energy use data are compared for the 5 months immediately following the retrofit. Occupant reactions and experiences are also described. The retrofit measures implemented for the Belmont Two-Family resulted in a home with airtightness of 0.93 air changes per hour at 50 pascal test pressure, a Home Energy Rating System index of 44 (excluding photovoltaics), and initial energy use significantly less than the energy models projected. The home is on track to meet the Thousand Home Challenge. In these ways, the project meets or exceeds the energy goals established for the retrofit. Energy modeling tools were found to be useful during the planning stage for investigating the relative cost effectiveness of retrofit measures. They were less effective, however, in projecting actual energy use. Discrepancies between the results of different tools need to be better understood, and interactions among retrofit measures are not effectively handled by the energy modeling tools at this time. During the first few months after the retrofit, the homeowner had questions about the effective operation of the mechanical equipment. With the increased airtightness and R-values, the equipment needs to be operated differently to realize the potential energy savings. This information needs to be better understood and disseminated by everyone involved with retrofit projects. This technical report contributes to several basic areas of research. These include the combination of measures that is feasible, affordable, and acceptable to homeowners as well as expectations versus results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

The Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. Featured speakers included John Straube, Christopher Schumacher and Kohta Ueno of Building Science Corporation, Henri Fennell of Building Envelope Solutions, Inc., and Mark Bomberg of Syracuse University. Some ad hoc presentations were given by practitioners in the audience as well. This was followed by a question-and-answer period and discussion. Key results from this meeting were: • Greater understanding of the state-of-art in assessing risks or and performing interior insulation retrofit of mass masonry wall assemblies • Greater understanding of the uncertainties in assessments • Definition of key research needs to investigate and potentially reduce uncertainties. Extensive information was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks. It was found that conflicting understanding exists, such as general assessment approaches, assessments of masonry material properties, and the inclusion of air spaces between insulation and masonry units in hygrothermal analysis. Little research has been conducted on these issues, as well other major key issues such as the impact the architectural detailing has on rainwater concentration, timber beam pocket strategies, and below grade strategies. The next steps are to define projects to address the research needs identified at the meeting. One upcoming retrofit was put forward as an opportunity to experiment with methodologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations, Inc. Net Zero Energy Communities, Devens, Easthampton, Townsend, Massachusetts (Fact Sheet)

In 2009, Transformations, Inc. partnered with U.S. Department of Energy (DOE) Building America team Building Science Corporation (BSC) to build new net zero energy houses in three developments in Massachusetts. The company has been developing strategies for cost-effective super-insulated homes in the New England market since 2006. After years of using various construction techniques, it has developed a specific set of assemblies and specifications that achieve a 44.9% reduction in energy use compared with a home built to the 2009 International Residential Code, qualifying the houses for the DOE's Challenge Home. The super-insulated houses provide data for several research topics in a cold climate. BSC studied the moisture risks in double stud walls insulated with open cell spray foam and cellulose. The mini-split air source heat pump (ASHP) research focused on the range of temperatures experienced in bedrooms as well as the homeowners' perceptions of equipment performance. BSC also examined the developer's financing options for the photovoltaic (PV) systems, which take advantage of Solar Renewable Energy Certificates, local incentives, and state and federal tax credits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Case Study: Transformations, Inc. Net Zero Energy Communities, Devens, Easthampton, Townsend, Massachusetts

In 2009, Transformations, Inc. partnered with Building America team Building Science Corporation (BSC) to build new net zero energy houses in three developments in Massachusetts. The company has been developing strategies for cost-effective super-insulated homes in the New England market since 2006. After years of using various construction techniques, it has developed a specific set of assemblies and specifications that achieve a 44.9% reduction in energy use compared with a home built to the 2009 International Residential Code, qualifying the houses for the DOE’s Challenge Home. The super-insulated houses provide data for several research topics in a cold climate. BSC studied the moisture risks in double stud walls insulated with open cell spray foam and cellulose. The mini-split air source heat pump (ASHP) research focused on the range of temperatures experienced in bedrooms as well as the homeowners’ perceptions of equipment performance. BSC also examined the developer’s financing options for the photovoltaic (PV) systems, which take advantage of Solar Renewable Energy Certificates, local incentives, and state and federal tax credits.

air source heat pump↗

Moisture Durability with Vapor-Permeable Insulating Sheathing

Exterior sheathing insulation is an effective strategy in increasing the overall R-value of wall assemblies; other benefits include decreasing the effects of thermal bridging and increasing the moisture durability of the built assembly. Vapor-permeable exterior insulation, such as mineral board or expanded polystyrene foam, are one such product that may be used to achieve these benefits. However,uncertainty exists on the effects of inward driven moisture and the interaction of increased sheathing temperatures on the moisture durability of the edifice. To address these concerns, Building Science Corporation (BSC) conducted a series of hygrothermal models for cities representing a range of different climate zones. This report describes the research project, key research questions, and theprocedures utilized to analyse the problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗