Search NASA⌕ Search

SEARCH · Search NASA

Results for “CADMIUM 100”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Photoreflectance Study of Boron Ion-Implanted (100) Cadmium Telluride

Ion implanted (100) cadmium telluride was studied using the contactless technique of photoreflectance. The implantations were performed using 50- to 400-keV boron ions to a maximum dosage of 1.5 x 10(16)/sq cm, and the annealing was accomplished at 500 C under vacuum. The spectral measurements were made at 77 K near the E(0) and E(1) critical points; all the spectra were computer-fitted to Aspnes' theory. The spectral line shapes from the ion damaged, partially recovered and undamaged, or fully recovered regions could be identified, and the respective volume fraction of each phase was estimated.

Amirtharaj, P. M.↗

Penning trap mass measurements of {sup 99-109}Cd with the ISOLTRAP mass spectrometer, and implications for the rp process

Penning trap mass measurements of neutron-deficient Cd isotopes {sup 99-109}Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3{center_dot}10{sup -8}. A new mass evaluation has been performed. The mass of {sup 99}Cd has been determined for the first time, which extends the region of accurately known mass values toward the doubly magic nucleus {sup 100}Sn. The implication of the results on the reaction path of the rp process in stellar x-ray bursts is discussed. In particular, the uncertainty of the abundance and the overproduction created by the rp-process for the mass A=99 are demonstrated by reducing the uncertainty of the proton-separation energy of {sup 100}InS{sub p}({sup 100}In) by a factor of 2.5.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electric quadrupole moments of the 2{sub 1}{sup +} states in {sup 100,102,104}Cd

Using the REX-ISOLDE facility at CERN the Coulomb excitation cross sections for the 0{sub gs}{sup +}{yields}2{sub 1}{sup +} transition in the {beta}-unstable isotopes {sup 100,102,104}Cd have been measured for the first time. Two different targets were used, which allows for the first extraction of the static electric quadrupole moments Q(2{sub 1}{sup +}) in {sup 102,104}Cd. In addition to the B(E2) values in {sup 102,104}Cd, a first experimental limit for the B(E2) value in {sup 100}Cd is presented. The data was analyzed using the maximum likelihood method. The provided probability distributions impose a test for theoretical predictions of the static and dynamic moments. The data are interpreted within the shell-model using realistic matrix elements obtained from a G-matrix renormalized CD-Bonn interaction. In view of recent results for the light Sn isotopes the data are discussed in the context of a renormalization of the neutron effective charge. This study is the first to use the reorientation effect for post-accelerated short-lived radioactive isotopes to simultaneously determine the B(E2) and the Q(2{sub 1}{sup +}) values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 100 ampere-hour nickel cadmium battery development program, volume 1

A program to develop a long-life, reliable and safe 100 ampere-hour sealed nickel-cadmium cell and battery module with ancillary charge control and automated test equipment to fulfill the requirements of a large Manned Orbital Space Station which uses Solar Arrays as its prime source for 25 kW of electrical power was conducted. A sealed 100 ampere-hour cell with long life potential and a replaceable, space maintainable battery module has been developed for Manned Space Station applications. The 100 ampere-hour cell has been characterized for initial (early life) anticipated conditions.

Gaston, S.↗

Design and test of a 100 ampere-hour nickel cadmium battery module

A feasibility study was conducted on the design and construction of a flight-worthy replaceable battery module consisting of four 100 A.H. nickel-cadmium rechargeable cells for large manned space vehicles. The module is planned to weigh less than 43 pounds and be fully maintainable in a zero-g environment by one man without use of special tools. An active environmental control system was designed for the temperature control of the module.

Gaston, S.↗

Nuclear Data Sheets for A = 100

The evaluated experimental data are presented for 15 known nuclides of mass 100 (Kr, Rb, Sr, Y, Zr, Nb, Mo, Tc, Ru, Rh, Pd, Ag, Cd, In, Sn). High spin excitations are known for {sup 100}Sr, {sup 100}Zr, {sup 100}Mo, {sup 100}Tc, {sup 100}Ru, {sup 100}Rh, {sup 100}Pd, {sup 100}Ag, and {sup 100}Cd. The neutron capture data are available for {sup 100}Tc and {sup 100}Ru. Particle transfer data exist for structures in {sup 100}Nb, {sup 100}Mo, {sup 100}Tc and {sup 100}Ru. The two-neutrino {beta}{beta} decay mode in {sup 100}Mo is fully established with measured half-life and population of the g.s. and 1130,0+ state in {sup 100}Ru. The absolute energy of the isomer in {sup 100}Nb is now well established from recent Penning-trap mass measurements. Excited state data are nonexistent for {sup 100}Kr, {sup 100}Rb and {sup 100}Sn; and only one excited state is known in {sup 100}In. Except for isotopic identification, no information is available for the decay of the {sup 100}Kr isotope and very little is known about the decay properties of the {sup 100}Sn isotope. In the case of {sup 100}Pd, there are many recent studies of high-spin structures but the agreement in the orderings of the {gamma}-ray cascades and {gamma}-ray inventory between various studies remains poor at high (>9 MeV) excitation energies. The energy difference between the g.s. an isomer in {sup 100}Y has recently been precisely measured in Penning-Penning-trap mass measurements, however, the assignments of the two previously known half-lives and J{pi}'s to the respective states (g.s. and the 145-keV isomer) in {sup 100}Y remains to be established. Static moments in {sup 100}Y have also been recently measured for one of these states in {sup 100}Y but it is not definitely known as to which of the two states (g.s. or the isomer) is connected with these measurements. This work supersedes earlier full evaluations of A = 100 by 1997Si09, 1990Si05 and 1974Ko37.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation program for secondary spacecraft cells: Acceptance test of Eagle-Picher 100 ampere-hour nickel-cadmium cells with auxiliary electrodes

Tests were conducted on a group of 29 cells for the purpose of removing from the life cycle program all cells found to have electrolyte leakage, internal shorts, low capacity, or inability to recover open circuit voltage above 1.150 volts after the cell short test. The test findings include the following: (1) All the cells exceeded the rated capacity of 103.5 to 119.0 ampere-hours on all three capacity checks. (2) All cells recovered above the 1.150 volt requirement after the cell short test. (3) The cells cannot be overcharged at the c/10 rate without exceeding 1.500 volts after approximately 12 to 13 hours of charge. (4) The resistance value necessary to provide maximum signal power across the auxiliary electrode was found to be 10 ohms. (5) One cell revealed a definite leak at the negative terminal.

Christy, D. E.↗

SU-E-T-301: Spectral Comparison of the Xoft and Zeiss 50 KVp X-Ray Systems

Purpose: To compare x-ray spectra of the 50 kVp Xoft Axxent™ and Zeiss INTRABEAM™ x-ray sources after filtration by saline-filled balloons applicators or spherical polymer applicators, respectively. Methods: Measurements were made for 3.5, 4.0 and 5.0 cm diameter applicators using an AmpTek model XR-100T-CdTe cadmium telluride spectrometer with 100 μm diameter collimating aperture and model PX4 digital pulse processor. Spectra were then corrected for escape processes using AmpTek XRF-FP Escape software. Both Axxent and INTRABEAM sources were operated at 50 kV and 40 μA to eliminate pulse saturation. The balloon or spherical applicator was placed in a centering fixture in contact with the collimator cap. The distance through the collimator housing from the applicator surface to the spectrometer's beryllium entrance window was nominally 52mm. Approximately 500,000 counts were collected for each spectrum. Results: Measured spectra in all cases had a broad Bremsstrahlung continuum with subtle differences in characteristic low energy x-rays lines from the different materials used for the anode thin films and substrates. After corrections for escape events average energies were calculated for spectra emerging from applicators. The average energies were 28.2 ±0.3 keV, 29.0±0.7 keV, and 31.7±0.9 keV for the 3.5, 4.0 and 5.0 cm diameter applicators, respectively. Differences in average energies ranged from 2.0 to 5.6% for these diameters. The mean energies of the spectra are more dependent on balloon size than on the delivery system used. Conclusion: Energy spectra at the surfaces of 3.5, 4.0 and 5.0 cm diameter applicators were measured for the Axxent and INTRABEAM x-ray systems were using a Cd-Te spectrometer. The average energies of the two x-ray systems for comparable applicator sizes were within 5.6%, and as little as 0.6 keV difference for the smaller applicator size. Research sponsored by Xoft, a subsidiary of ICAD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One hundred ampere-hour nickel-cadmium battery cells of improved design

Nickel cadmium battery cells with 100 ampere hour capacity were developed. The design features, notably extension of the current collector tab to the full width of the battery plate, and the location of the cell terminals on the opposite ends, resulted in a reduction of internal impedance, and improved electrical performance with expected improvement in thermal performance. Tables of data and performance curves are included to support the theoretical considerations.

Kantner, E.↗

Enhanced p-Type Doping in Polycrystalline CdTe Films: Deposition and Activation

An in situ nonequilibrium method to increase hole density in polycrystalline CdTe thin films to 10 16 cm -3 using group V substitution on Te is presented. Single-phase CdTe films doped with P, As, and Sb were deposited at 550 degrees C at 100-200 nm/s onto moving cadmium sulfide/high resistance transparent buffer layer/transparent conductive oxide /glass superstrates by vapor transport deposition in Cd overpressure from high purity compound sources. Doping levels before and after activation were determined by capacitance-voltage analysis of diagnostic devices. Secondary ion mass spectrometry depth profiling confirmed dopant incorporation levels of 10 17 -10 18 atoms/cm 3 in as-deposited films. Electronic activation was carried out by post-deposition annealing in Cd or CdCl 2 vapor with fast cooling, increasing acceptor concentrations to >10 15 cm -3 for P and >10 16 cm -3 for As and Sb, compared with mid -10 14 cm -3 acceptor levels for undoped CdTe films. The activation methods are compatible with post-deposition processing presently used for high-efficiency CdTe solar cells. For the dopants As and Sb, the acceptor concentration increased by substitutional As Te and Sb Te formation, respectively, which was validated by cathodoluminescence spectroscopy.

14 SOLAR ENERGY↗

Energy storage cycling tests

Results of cyclic tests on seven 3-cell 100 A-H nickel cadmium batteries on 1.5 hr cycles are presented. The failure of the nylon and polypropylene separators was not analyzed.

Bragg, B. J.↗

Fabrication and testing of negative-limited sealed nickel-cadmium cells

The design, construction, and testing of 100,20Ah and 100,3Ah negative-limited sealed cells are reported. The required physical dimensions of the hardware and components necessary to produce 20 and 3 Ah cells were established. The stainless steel cans and covers have been ordered. The covers contain two ceramic seals. The fabrication of electrodes was started. About 55% (879 electrodes) of the required cadmium electrodes has been prepared. About 44% of the porous nickel substrates (plaques) required for the preparation of the nickel oxide electrodes has been completed.

Luksha, E.↗

Design of cascaded low cost solar cell with CuO substrate

For many years the main focus of R and D in solar cells was the development of high-efficiency solar convertors. However with solar technology beginning to be a part of national grids and stand-alone power supplies for variety of individual customers, the emphasis has changed, namely, the cost per kilowatt- hour (kW-hr) started to be an important figure of merit. Although Si does dominate the market of solar convertors, this material has total cost of kilowatt-hour much higher than what the power grid is providing presently to customers. It is well known that the cost of raw semiconductor material is a major factor in formulation of the final cost of a solar cell. That motivated us to search and design a novel solar cell using cheap materials. The new p-i-n solar cell consists of hetero-structure cascade of materials with step by step decreasing energy gap. Since the lattice constant of these three materials do differ not more than 2%, the more expensive epitaxial fabrication methods can be used as well. It should be emphasized that designed solar cell is not a cascade of three solar cells connected in series. Our market study shows that Si solar panel which costs $250–400 / m{sup 2} leads to a cost of $0.12–0.30 / kW-hr. To the contrary, CuO based solar cells with Cadmium compounds on top, would cost $100 / m{sup 2}. This will allow the novel solar cell to produce electricity at a cost of $0.06–0.08 / kW-hr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗