Search NASA⌕ Search

SEARCH · Search NASA

Results for “CADMIUM 105”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=105☆

This work presents new evaluation of A=105 nuclear structure and decay data. It covers a range of nuclei from the very neutron-rich {sup 105}{sub 38}Sr to the extremely neutron-deficient {sup 105}{sub 52}Te, known also to be the doughter of the lightest alpha decaying nucleus {sup 109}I. The work is based on experimental studies performed in the last 73 years, where A=105 nuclei were produced in particle transfer, fusion/evaporation reactions, sponataneus and induced fission, fusion and fragmentation of relativistic beams, radioactive decay etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Penning trap mass measurements of {sup 99-109}Cd with the ISOLTRAP mass spectrometer, and implications for the rp process

Penning trap mass measurements of neutron-deficient Cd isotopes {sup 99-109}Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3{center_dot}10{sup -8}. A new mass evaluation has been performed. The mass of {sup 99}Cd has been determined for the first time, which extends the region of accurately known mass values toward the doubly magic nucleus {sup 100}Sn. The implication of the results on the reaction path of the rp process in stellar x-ray bursts is discussed. In particular, the uncertainty of the abundance and the overproduction created by the rp-process for the mass A=99 are demonstrated by reducing the uncertainty of the proton-separation energy of {sup 100}InS{sub p}({sup 100}In) by a factor of 2.5.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Possibility of antimagnetic rotation in odd-A Cd isotopes

The classical particle-plus-rotor model for antimagnetic rotation (AMR) is used to investigate the possibility of observing AMR in the high-spin levels of {sup 105,107,109}Cd. The calculated I({omega}) plot and B(E2) values are compared with the available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-beam fast-timing measurements in {sup 103,105,107}Cd

Fast-timing measurements were performed in the region of the medium-mass {sup 103,105,107}Cd isotopes, produced in fusion evaporation reactions. Results on new and reevaluated half-lives are analyzed within a systematic study of transition rates. The 7/2{sub 1}{sup +} states in {sup 103,105,107}Cd are interpreted as arising from a single-particle excitation. The 9/2{sup +} states configuration assignment is based on the observed decay branches.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of antimagnetic rotation in odd-A {sup 105}Cd

The lifetimes of the levels above spin 23/2{sup -} in the negative-parity yrast band of {sup 105}Cd have been measured using the Doppler shift attenuation method. The obtained B(E2) values are small and show a decrease with an increase in spin. This establishes, for the first time, antimagnetic rotation (AMR) in an odd-A nucleus. An excellent agreement between the theoretical (semiclassical model) and experimental results along with a large I{sup (2)}/B(E2) ratio for the states strongly suggests that the structure of the levels beyond spin 23/2{sup -} has the character of a twin-shears type AMR band resulting from the coupling of a pair of g{sub 9/2} proton holes with aligned h{sub 11/2} and (g{sub 7/2}){sup 2} neutron particles, along with a small contribution from the core rotation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic and antimagnetic rotation in covariant density functional theory

Progress on microscopic and self-consistent description of the magnetic rotation and antimagnetic rotation phenomena in tilted axis cranking relativistic mean-field theory based on a point-coupling interaction are briefly reviewed. In particular, the microscopic pictures of the shears mechanism in {sup 60}Ni and the two shears-like mechanism in {sup 105}Cd are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

A CCD scanned (Hg, Cd)Te array for earth viewing applications

A 9 channel demonstration of 10 micrometer photoconductive mercury cadmium telluride detector array, bipolar preamplifiers, and a Si CCD multiplexer, integrated into a focal plane assembly and operating at 105 K and at 17 Hz is reported. The result of a direct coupling experiment between a 5-micrometer photovoltaic mercury cadmium telluride photodiode and a CCD is revealed. No appreciable degradation in the signal-to-noise ratio was experienced.

Iwasa, S.↗

Core-excited states in 105 Cd

105 Cd was produced in the 96 Mo+ 12 C fusion/evaporation reaction, performed at NIPNE, Bucharest-Magurele, Romania. Various excited states of positive- and negative-parities were populated. Picosecond half-lives were measured by using the Differential Decay Curve Method (DDCM) method, allowing to control the side feeding of the states of interest. Further, new data were obtained for the half-lives of the 11/2 + , 15/2 - and 19/2 -105 Cd states. Reduced electric quadrupole transition strengths were calculated and compared to the neighboring odd-A and even-A cadmium nuclei. The particle-core weak coupling approach was used to interpret excited states of 105 Cd in the light of the new data.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-D-BRA-07: Applications of Combined KV/MV CBCT Imaging with a High-DQE MV Detector

Purpose: To investigate whether a high detection quantum efficiency (DQE) MV detector makes combined kV/MV CBCT clinically practical. Methods: Combined kV/MV CBCT was studied for scan time reduction (STR) and metal artifact reduction (MAR). 6MV CBCT data (dose rate = 0.017 MU/degree) were collected using 1) a novel focused pixelated cadmium tungstate (CWO) scintillator (15mm thickness, DQE(0) = 22%, 0.784mm pixel pitch) coupled to a flat panel imager, and 2) a commercial portal imager with a 133mg/cm{sup 2} gadolinium oxysulfide (GOS) screen (DQE(0) = 1.2%). The 100kVp data were acquired using a commercial imager employing a columnar cesium iodide scintillator (DQE(0) = 70%) with a dose rate of 0.0016 cGy/degree. For STR, MV and kV projections spanning 105° were combined to constitute a complete CBCT scan. Total dose was ∼2cGy and acquisition time was 18s. For MAR, only the metalcorrupted pixels in the kV projections were replaced with MV data resulting in a total dose of less than 1cGy for a 360° scan. Image quality was assessed using an 18-cm diameter electron density phantom with nine tissue inserts, some of which were replaced with steel rods for MAR studies. Results: The CWO contrast-to-noise ratio (CNR) was ∼4.0x higher than the GOS CNR and was ∼4.8x lower than the kV CNR when normalized for dose. When CWO MV data were combined with kV data for STR, all contrast inserts were visible, but only two were detectable in the composite kV/GOS image. Metal artifacts were greatly reduced using the kV/MV MAR technique with all contrast inserts clearly visible in the composite kV/CWO image but only two inserts visible in the composite kV/GOS image. Conclusion: We have demonstrated that a high DQE MV detector significantly improves kV/MV CBCT image quality thus enabling scan time reduction and metal artifact reduction without a severe dose penalty. AW and JS-L are employees of Varian, RF is an employee of Siemens.

60 APPLIED LIFE SCIENCES↗

Capturing the variable reactivity of goethites in surface complexation modeling by correlating model parameters with specific surface area

The development of predictive tools capable of simulating adsorption behavior on goethite (α-FeOOH) surfaces has evolved over the past several decades. Recent research has focused on capturing the variation of surface reactivity and adsorption behavior for different preparations of synthetic goethites. Here in this research, an approach to estimate modeling parameters based on the specific surface area (SSA) of goethites was established and combined with a Charge Distribution – Multi-site Complexation (CD-MUSIC) surface complexation model. It was assumed that differences in crystal face contributions (CFC), inner-Helmholtz capacitances (C 1 ), and protonation constants of surface oxygens (pK a ’s) among different preparations of goethite contribute to the variation of surface reactivity. Thus, correlations of these modeling parameters with the SSA of a range of goethites were identified by comprehensively combining microscopic, macroscopic, and modeling data reported in literature along with adsorption data collected from macroscopic experiments conducted as part of this study. A CD-MUSIC model shown to be capable of accurately predicting adsorption for several metal ions and oxyanion selenite on a 62.9 m 2 /g SSA goethite served as the basis for the development of the adsorption modeling approach described in this paper. The predictive capability of the newly developed modeling approach was verified by comparing predictions of protons, SeO 3 2- , and Cd 2+ adsorption with experimental data from goethites with SSAs ranging between 21.3 and 105 m 2 /g; in total, 40 adsorption data sets from 13 different goethites were used for model verification. The results from this study indicate that the variation of surface reactivity of goethites can be successfully simulated by changing CFC, C 1 , and pK 2,singly (i.e. second protonation constant of singly-coordinated oxygens on the goethite surface) based on the SSA, which implies that self-consistent adsorption parameters can be applied to predict adsorption behavior over a range of goethite preparations.

58 GEOSCIENCES↗