The Mu2e Crystal and SiPM Calorimeter: Construction Status

The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with an energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large-area UV-extended silicon photomultipliers (SiPMs). It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this article, we present the status of construction and the quality control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

Comparison of point cloud and image-based models for calorimeter fast simulation

Score based generative models are a new class of generative models that have been shown to accurately generate high dimensional calorimeter datasets. Recent advances in generative models have used images with 3D voxels to represent and model complex calorimeter showers. Point clouds, however, are likely a more natural representation of calorimeter showers, particularly in calorimeters with high granularity. Furthermore, point clouds preserve all of the information of the original simulation, more naturally deal with sparse datasets, and can be implemented with more compact models and data files. In this work, two state-of-the-art score based models are trained on the same set of calorimeter simulation and directly compared.

47 OTHER INSTRUMENTATION↗

The CLAS12 forward electromagnetic calorimeter

The CLAS12 Forward Detector includes six independent lead-scintillator electromagnetic sampling calorimeters to provide the primary electron trigger and extend the CLAS12 detection capability to photons and neutrons. Each calorimeter package consists of two modules, the legacy Electromagnetic Calorimeter (EC) previously used in the CLAS detector, and a new pre-shower calorimeter (PCAL) located in front of the EC to extend the total detector radiation length, in order to fully absorb the electromagnetic showers induced by electrons with energies up to 12 GeV. Both calorimeters use a novel triangular hodoscope geometry with stereo readout. The PCAL uses an upgraded design to provide the high spatial resolution necessary for reconstructing π 0 and η decays, and neutrons with high efficiency. Here, this paper treats the design, construction, and calibration of the PCAL and the preliminary combined performance of both detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- &#x3B7; experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

The optimal use of segmentation for sampling calorimeters

One of the key design choices of any sampling calorimeter is how fine to make the longitudinal and transverse segmentation. Here, to inform this choice, we study the impact of calorimeter segmentation on energy reconstruction. To ensure that the trends are due entirely to hardware and not to a sub-optimal use of segmentation, we deploy deep neural networks to perform the reconstruction. These networks make use of all available information by representing the calorimeter as a point cloud. To demonstrate our approach, we simulate a detector similar to the forward calorimeter system intended for use in the ePIC detector, which will operate at the upcoming Electron Ion Collider. We find that for the energy estimation of isolated charged pion showers, relatively fine longitudinal segmentation is key to achieving an energy resolution that is better than 10% across the full phase space. These results provide a valuable benchmark for ongoing EIC detector optimizations and may also inform future studies involving high-granularity calorimeters in other experiments at various facilities.

47 OTHER INSTRUMENTATION↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AI-assisted object condensation clustering for calorimeter shower reconstruction at CLAS12

Several nuclear physics studies using the CLAS12 detector rely on the accurate reconstruction of neutrons and photons from its forward angle calorimeter system. These studies often place restrictive cuts when measuring neutral particles due to an overabundance of false clusters created by the existing calorimeter reconstruction software. In this work, we present a new AI approach to clustering CLAS12 calorimeter hits based on the object condensation framework. The model learns a latent representation of the full detector topology using GravNet layers, serving as the positional encoding for an event’s calorimeter hits which are processed by a Transformer encoder. This unique structure allows the model to contextualize local and long range information, improving its performance. Evaluated on one million simulated $e^-$ $+$ $p$ collision events, our method significantly improves cluster trustworthiness: the fraction of reliable neutron clusters, increasing from 8.88% to 30.73%, and photon clusters, increasing from 51.07% to 64.73%. In conclusion, our study also marks the first application of AI clustering techniques for hodoscopic detectors, showing potential for usage in many other experiments.

Calorimeters↗

On the resolution of dual readout calorimeters

Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.

Calorimeters↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗