Search NASA⌕ Search

SEARCH · Search NASA

Results for “CAM loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.

25 ENERGY STORAGE↗

Operando neutron imaging-guided gradient design of Li-ion solid conductor for high-mass-loading cathodes

High-mass-loading cathodes are crucial for achieving high energy density in all-solid-state batteries from the lab scale to industry. However, as mass-loading increases, electrochemical performance is significantly compromised due to sluggish kinetics. In this work, operando neutron imaging is deployed on a high-mass-loading NMC 811 cathode of 33 mg/cm 2 (5.0 mAh/cm 2 ) and directly visualizes the lithiation prioritization of the cathode active material (CAM) from the solid electrolyte membrane side to the current collector side. In addition to the tortuosity, another key limitation on ion transfer in the cathode arises from the mismatch between the uniform distribution of the solid electrolyte (catholyte) in the conventional composite cathode and the non-uniform Li + flux generated by the faradaic reaction of CAMs. Therefore, we engineer a gradient in the catholyte concentration to match the Li + flux distribution as a means of eliminating the ion transfer obstacle. This approach demonstrates enhanced rate performance, even with high-mass-loading cathodes. A LiCoO 2 composite cathode with 100 mg/cm 2 high-mass-loading exhibits an areal capacity of 10.4 mAh/cm 2 at a current density of 2.25 mA/cm 2 . This work provides insight into the ion-transport limitation in thick cathodes and demonstrates an effective gradient design to overcome the kinetic barrier and achieve high battery performance.

Batteries↗

Moving beyond the Aerosol Climatology of WRF-Solar: A Case Study over the North China Plain

Numerical weather prediction (NWP), when accessible, is a crucial input to short-term solar power forecasting. WRF-Solar, the first NWP model specifically designed for solar energy applications, has shown promising predictive capability. Nevertheless, few attempts have been made to investigate its performance under high aerosol loading, which attenuates incoming radiation significantly. The North China Plain is a polluted region due to industrialization, which constitutes a proper testbed for such investigation. Here, in this paper, aerosol direct radiative effect (DRE) on three surface shortwave radiation components (i.e., global, beam, and diffuse) during five heavy pollution episodes is studied within the WRF-Solar framework. Results show that WRF-Solar overestimates instantaneous beam radiation up to 795.3 W m -2 when the aerosol DRE is not considered. Although such overestimation can be partially offset by an underestimation of the diffuse radiation of about 194.5 W m -2 , the overestimation of the global radiation still reaches 160.2 W m -2 . This undesirable bias can be reduced when WRF-Solar is powered by Copernicus Atmosphere Monitoring Service (CAMS) aerosol forecasts, which then translates to accuracy improvements in photovoltaic (PV) power forecasts. This work also compares the forecast performance of the CAMS-powered WRF-Solar with that of the European Centre for Medium-Range Weather Forecasts model. Under high aerosol loading conditions, the irradiance forecast accuracy generated by WRF-Solar increased by 53.2% and the PV power forecast accuracy increased by 6.8%.

54 ENVIRONMENTAL SCIENCES↗

Cam-Clay plasticity. Part IX: On the anisotropy, heterogeneity, and viscoplasticity of shale

Here, we investigate three aspects of material behavior in this ninth installment of the Cam-Clay series, namely, anisotropy, heterogeneity, and viscoplasticity. The main focus of the paper is creep in shale and how this time-dependent deformation behavior may be quantified across the scales, from nanometers to millimeters. Recognizing the highly heterogeneous nature of shale, we adopt a simplified representation of this material as a mixture of softer matter representing organics and clay, and harder matter representing the inorganic rock matrix. Due to the presence of bedding planes in the rock matrix, anisotropy in both the elastic and inelastic responses is assumed; yet, the superimposed softer matter may be taken to be isotropic unless experimental evidence indicates otherwise. Viscoplasticity is considered for the first time in this series of work, in which both the Duvaut-Lions and Perzyna formulations are utilized. The two viscoplastic formulations are shown to predict very similar time-dependent deformation responses. The framework is used to interpret the results of multiscale triaxial laboratory creep tests in organic-rich Barnett shale. Time-dependent strain localization in the form of dilative shear bands is also shown to result from loading with varying strain rates, as well as from creep processes that accommodate the multiscale heterogeneity of shale.

42 ENGINEERING↗

Project Planning for Community Resilience: Aquinnah and Chilmark, Massachusetts

This report presents the findings of an energy system planning study for the towns of Aquinnah and Chilmark, MA, on the island of Martha’s Vineyard, conducted under the U.S. Department of Energy ETIPP program. The study used the DER-CAM model to optimize the deployment of PV and battery microgrids to enhance energy resilience against power outages, particularly winter storms. Key findings show that PV is highly cost-effective and delivers net annual savings. However, due to limited rooftop space and low winter solar output, PV and battery storage alone cannot support the full critical load during outages. Solutions incorporating conventional backup generators were found to be more economically viable for achieving 100% critical load support.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hyper Suprime-Cam Legacy Archive

Abstract We present the launch of the Hyper Suprime-Cam Legacy Archive (HSCLA), a public archive of processed, science-ready data from the Hyper Suprime-Cam (HSC). HSC is an optical wide-field imager installed at the prime focus of the Subaru Telescope and has been in operation since 2014. While ∼1/3 of the total observing time of HSC has been used for the Subaru Strategic Program (SSP), the remainder of the time is used for Principal Investigator (PI)-based programs. We have processed the data from these PI-based programs and make the processed, high-quality data available to the community through HSCLA. The current version of HSCLA includes data taken in the first year of science operation, 2014. We provide both individual and coadd images as well as photometric catalogs. The photometric catalog from the coadd is loaded to the database, which offers a fast access to the large catalog. There are other online tools such as an image browser and an image cutout tool and they will be useful for science analyses. The coadd images reach 24–27th magnitudes at 5σ for point sources and cover approximately 580 square degrees in at least one filter with 150 million objects in total. We perform extensive quality assurance tests and verify that the photometric and astrometric quality of the data is good enough for most scientific explorations. However, the data are not without problems and users are referred to the list of known issues before exploiting the data for science. All the data and documentations can be found at the data release site, 〈https://hscla.mtk.nao.ac.jp/〉.

Tanaka, Masayuki↗

A multiscale model of the action of a capsid assembly modulator for the treatment of chronic hepatitis B

Chronic hepatitis B virus (HBV) infection is strongly associated with increased risk of liver cancer and cirrhosis. While existing treatments effectively inhibit the HBV life cycle, viral rebound frequently occurs following treatment interruption. Consequently, functional cure rates of chronic HBV infection remain low and there is increased interest in a novel treatment modality, capsid assembly modulators (CAMs). Here, we develop a multiscale mathematical model of CAM treatment in chronic HBV infection. By fitting the model to participant data from a phase I trial of the first-generation CAM vebicorvir, we estimate the drug’s dose-dependent effectiveness and identify the physiological mechanisms that drive the observed biphasic decline in HBV DNA and RNA, and mechanistic differences between HBeAg-positive and negative infection. Finally, we demonstrate analytically and numerically that the relative change of HBV RNA more accurately reflects the antiviral effectiveness of a CAM than the relative change in HBV DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Second data release of the Hyper Suprime-Cam Subaru Strategic Program

This paper presents the second data release of the Hyper Suprime-Cam Subaru Strategic Program, a wide-field optical imaging survey using the 8.2 m Subaru Telescope. We report the release includes data from 174 nights of observation through 2018 January. The Wide layer data cover about 300 deg$^2$ in all five broad-band filters ($grizy$) to the nominal survey exposure (10 min in $gr$ and 20 min in $izy$). Partially observed areas are also included in the release; about 1100 deg$^2$ is observed in at least one filter and one exposure. The median seeing in the i-band is ${0_{.}^{\prime \prime }6}$, demonstrating the superb image quality of the survey. The Deep (26 deg$^2$) and UltraDeep (4 deg$^2$) data are jointly processed and the UltraDeep-COSMOS field reaches an unprecedented depth of $i\sim 28$ at $5 \, \sigma$ for point sources. In addition to the broad-band data, narrow-band data are also available in the Deep and UltraDeep fields. This release includes a major update to the processing pipeline, including improved sky subtraction, PSF modeling, object detection, and artifact rejection. The overall data quality has been improved, but this release is not without problems; there is a persistent deblender problem as well as new issues with masks around bright stars. The user is encouraged to review the issue list before utilizing the data for scientific explorations. All the image products as well as catalog products are available for download. The catalogs are also loaded into a database, which provides an easy interface for users to retrieve data for objects of interest. In addition to these main data products, detailed galaxy shape measurements withheld from Public Data Release 1 (PDR1) are now available to the community. The shape catalog is drawn from the S16A internal release, which has a larger area than PDR1 (160 deg$^2$). All products are available at the data release site, https://hsc-release.mtk.nao.ac.jp/.

79 ASTRONOMY AND ASTROPHYSICS↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗