Development and evaluation of an impedance cardiac output system.
Impedance cardiac output values simultaneously compared with dye dilution techniques under rest and exercise conditions
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Impedance cardiac output values simultaneously compared with dye dilution techniques under rest and exercise conditions
Although not available to all patients with narrowed arteries, balloon angioplasty has expanded dramatically since its introduction with an estimated further growth to 562,000 procedures in the U.S. alone by 1992. Growth has fueled demand for higher quality imaging systems that allow the cardiologist to be more accurate and increase the chances of a successful procedure. A major advance is the Digital Cardiac Imaging (DCI) System designed by Philips Medical Systems International, Best, The Netherlands and marketed in the U.S. by Philips Medical Systems North America Company. The key benefit is significantly improved real-time imaging and the ability to employ image enhancement techniques to bring out added details. Using a cordless control unit, the cardiologist can manipulate images to make immediate assessment, compare live x-ray and roadmap images by placing them side-by-side on monitor screens, or compare pre-procedure and post procedure conditions. The Philips DCI improves the cardiologist's precision by expanding the information available to him.
Impedance plethysmographic system for monitoring right ventricular output to obtain cardiac output
An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.
Four electrode impedance plethysmographic system for measuring left ventricular output
Impedance cardiographic system to measure cardiac output and cardiovascular functions
In this session, Session FA2, the discussion focuses on the following topics: Effects of Repeated Long Duration +2Gz Load on Man's Cardiovascular Function; Certain Approaches to the Development of On-Board Automated Training System; Cardiac, Arterial, and Venous Adaptation to Og during 6 Month MIR-Spaceflights with and without "Thigh Cuffs" (93-95); Space Cycle(TM) Induced Physiologic Responses; Muscular Deconditioning During Long-term Spaceflight Exercise Recommendations to Optimize Crew Performance; Structure And Function of Knee Extensors After Long-Duration Spaceflight in Man, Effects of Countermeasure Exercise Training; Force and power characteristics of an exercise ergometer designed for use in space; and The simulating of overgravity conditions for astronauts' motor apparatus at the conditions of the training for orbital flights.
Monitor One, a portable computer cardiac system, is marketed by Q- Med, Inc. The electrodes used are the same as those used to monitor astronaut heart action.
Systems and methods for remote, long standoff biometric identification using microwave cardiac signals are provided. In one embodiment, the invention relates to a method for remote biometric identification using microwave cardiac signals, the method including generating and directing first microwave energy in a direction of a person, receiving microwave energy reflected from the person, the reflected microwave energy indicative of cardiac characteristics of the person, segmenting a signal indicative of the reflected microwave energy into a waveform including a plurality of heart beats, identifying patterns in the microwave heart beats waveform, and identifying the person based on the identified patterns and a stored microwave heart beats waveform.
Impedance cardiograph for monitoring heart functions, and program for computing stroke volume and cardiac output from thoracic impedance changes during cardiac cycle
Performance of impedance cardiograph for measuring heart rate and body fluids
System measures electrocardiographic potentials to produce precise quantitative measurement of changes that occur in individual's cardiac function. System is rugged, built to sustain extremes of temperature, pressure, humidity, shock, and vibration. It can also be used in pure oxygen environment without danger of combustion.
The applications of aerospace technology to biomedical research are reported. The medical institutions participating in the Biomedical Applications Program are listed along with the institutions currently utilizing the services of the Southwest Research Institute Biomedical Applications Team. Significant accomplishments during this period include: ultra-low bandpass amplifier for gastro-intestinal electric potentials; non-encumbering EEG electrode assembly suitable for long term sleep research; accurate cardiac telemetry system for active subjects; warning system for the deaf; tracking cane for the blind; and an improved control mechanism to expand the self-sufficiency of quadriplegics.
Human heart rate, controlled by complex feedback mechanisms, is a vital index of systematic circulation. However, it has been shown that beat-to-beat values of heart rate fluctuate continually over a wide range of time scales. Herein we use the relative dispersion, the ratio of the standard deviation to the mean, to show, by systematically aggregating the data, that the correlation in the beat-to-beat cardiac time series is a modulated inverse power law. This scaling property indicates the existence of long-time memory in the underlying cardiac control process and supports the conclusion that heart rate variability is a temporal fractal. We argue that the cardiac control system has allometric properties that enable it to respond to a dynamical environment through scaling.
Orthostatic hypotension after even short space flights has affected a significant number of astronauts. Given the need for astronauts to function at a high level of efficiency during and after their return from space, the application of pharmacologic and other treatments is strongly indicated. This report addresses the clinical problem of orthostatic hypotension and its treatments to ascertain whether pharmacologic or physiologic treatment may be useful in the prevention of orthostatic hypotension associated with space flight. Treatment of orthostatic hypotension in patients now includes increasing intravascular volume with high sodium intake and mineralocorticoids, or increasing vascular resistance through the use of drugs to stimulate alpha or block beta vascular receptors. Earlier treatment used oral sympathomimetic ephedrine hydrochloride alone or with "head-up" bed rest. Then long-acting adrenocortical steroid desoxycorticosterone preparations with high-salt diets were used to expand volume. Fludrocortisone was shown to prevent the orthostatic drop in blood pressure. The combination of the sympathomimetic amine hydroxyamphetamine and a monoamine oxidase inhibitor tranylcypromine has been used, as has indomethacin alone. Davies et al. used mineralocorticoids at low doses concomitantly with alpha-agonists to increase vasoconstrictor action. Schirger et al used tranylcypromine and methylphenidate with or without a Jobst elastic leotard garment or the alpha-adrenergic agonist midodrine (which stimulates both arterial and venous systems without direct central nervous system or cardiac effects). Vernikos et al established that the combination of fludrocortisone, dextroamphetamine, and atropine exhibited a beneficial effect on orthostatic hypotension induced by 7-day 6 degrees head-down bed rest (a model used to simulate the weightlessness of space flight). Thus, there are numerous drugs that, in combination with mechanical techniques, including lower body negative pressure to elevate transmural pressure, could be studied to treat orthostatic hypotension after space flight.
Metabolic myopathies are disorders of muscle energy production that result in skeletal muscle dysfunction. Cardiac and systemic metabolic dysfunction may coexist. Symptoms are often intermittent and provoked by exercise or changes in supply of lipid and carbohydrate fuels. Specific disorders of lipid and carbohydrate metabolism in muscle are reviewed. Evaluation often requires provocative exercise testing. These tests may include ischemic forearm exercise, aerobic cycle exercise, and 31P magnetic resonance spectroscopy with exercise.
Study of the differential characteristics of hepatic congestion and decreased cardiac output in terms of potential afferent stimuli in the antinatriuretic effect of acute thoracic inferior vena cava (TIVC) constriction. An attempt is made to see if the autonomic nervous system is involved in the antinatriuretic effect of acute TIVC or thoracic superior vena cava constriction.
Multiple approaches are necessary for understanding and measuring workload. In particular, physiological systems identifiable by employing cardiac measures are related to cognitive systems. One issue of debate in measuring cardiac output is the grain of analysis used in recording and summarizing data. Various experiments are reviewed, the majority of which were directed at supporting or contradicting Lacey's intake-rejection hypothesis. Two of the experiments observed heart rate in operational environments and found virtually no changes associated with mental load. The major problems facing researchers using heart rate variability, or sinus arrhthmia, as a dependent measure have been associated with valid and sensitive scoring and preventing contamination of observed results by influences unrelated to cognition. Spectral analysis of heart rate variability offers two useful procedures: analysis from the time domain and analysis from the frequency domain. Most recently, data have been collected in a divided attention experiment, the performance measures and cardiac measures of which are detailed.