Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-resolution CCD imagers using area-array CCD's for sensing spectral components of an optical line image

CCD imagers with a novel replicated-line-imager architecture are abutted to form an extended line sensor. The sensor is preceded by optics having a slit aperture and having an optical beam splitter or astigmatic lens for projecting multiple line images through an optical color-discriminating stripe filter to the CCD imagers. A very high resolution camera suitable for use in a satellite, for example, is thus provided. The replicated-line architecture of the imager comprises an area-array CCD, successive rows of which are illuminated by replications of the same line segment, as transmitted by respective color filter stripes. The charge packets formed by accumulation of photoresponsive charge in the area-array CCD are read out row by row. Each successive row of charge packets is then converted from parallel to serial format in a CCD line register and its amplitude sensed to generate a line of output signal.

Elabd, Hammam↗

Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effort was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.

National Ignition Facility, X-ray diagnostic, X-ra↗

Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination

A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the CCD development for the Dark Energy Spectroscopic Instrument

We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)(2)-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a CCD for ultraviolet imaging using a CCD photocathode combination

CCD in the electron-in mode, coupled with a bi-alkali photocathode to produce UV photon conversion, provides the following desirable features: (1) high UV response of the bi-alkali photocathode; (2) excellent imaging quality of a CCD area array; and (3) high signal-to-noise ratio due to the EBS (electron bombarded silicon) gain of the CCD operating in a tube configuration. This paper describes the rationale and progress made in developing a CCD for use as an UV imager.

Collins, D. R.↗

A programmable CCD driver circuit for multiphase CCD operation

A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.

Ewin, Audrey J.↗

Consequences of CCD imperfections for cosmology determined by weak lensing surveys: from laboratory measurements to cosmological parameter bias

Weak gravitational lensing causes subtle changes in the apparent shapes of galaxies due to the bending of light by the gravity of foreground masses. By measuring the shapes of large numbers of galaxies (millions in recent surveys, up to tens of billions in future surveys) we can infer the parameters that determine cosmology. Imperfections in the detectors used to record images of the sky can introduce changes in the apparent shapes of galaxies, which in turn can bias the inferred cosmological parameters. In this paper we consider the effect of two widely discussed sensor imperfections: tree rings, due to impurity gradients that cause transverse electric fields in the charge-coupled devices (CCDs), and pixel size variation, due to periodic CCD fabrication errors. These imperfections can be observed when the detectors are subject to uniform illumination (flat-field images). We develop methods to determine the spurious shear and convergence (due to the imperfections) from the flat-field images. We calculate how the spurious shear when added to the lensing shear will bias the determination of cosmological parameters. We apply our methods to candidate sensors of the Large Synoptic Survey Telescope (LSST) as a timely and important example, analyzing flat-field images recorded with LSST prototype CCDs in the laboratory. We find that tree rings and periodic pixel size variation present in the LSST CCDs will introduce negligible bias to cosmological parameters determined from the lensing power spectrum, specifically w, Ω{sub m}, and σ{sub 8}.

79 ASTRONOMY AND ASTROPHYSICS↗

CCD imager with photodetector bias introduced via the CCD register

An infrared charge-coupled-device (IR-CCD) imager uses an array of Schottky-barrier diodes (SBD's) as photosensing elements and uses a charge-coupled-device (CCD) for arranging charge samples supplied in parallel from the array of SBD's into a succession of serially supplied output signal samples. Its sensitivity to infrared (IR) is improved by placing bias charges on the Schottky barrier diodes. Bias charges are transported to the Schottky barrier diodes by a CCD also used for charge sample read-out.

Kosonocky, Walter F.↗

A Python Module for Storing CCD Images with openPMD (openPMD-CCD) v0.1.0

openPMD is an open meta-data schema that provides meaning and self-description to data sets in science and engineering. The openPMD-CCD software module adds interfaces to organize camera (CCD) images in hierarchical data files. This software provides modern I/O storage formats from high-performance computing and provides bindings for integration into experimental control systems, e.g. via Python 3 and LabView 2020.

Gonsalves, AnthonyJ↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCD data acquisition systems at Lick and Keck Observatories

This paper will describe and compare two distinct but related CCD data acquisition systems (DAS) currently under development at Lick and Keck Observatories. Although these two systems have a number of major architectural differences, they share a considerable amount of common hardware and software. Both of these new systems build on a large body of proven software that is the foundation of the existing CCD DAS currently in use at Lick Observatory. Both will provide support for reading up to four on-chip amplifiers per CCD and/or reading out mosaics of CCD chips. In addition, they will provide the capability for interactive, real-time adjustment of CCD waveforms for engineering purposes. Each of these two systems is composed of three major subsystems: (1) an instrument computer and its software; (2) a data capture computer and its software; and (3) a CCD/dewar controller and its software. The instrument computer is a Unix workstation, and the functions it provides include user interfaces, the interactive real-time display of CCD images, and the recording of image and FITS header data to disk and/or tape. The data capture computer is responsible for the packaging and high-speed transfer of the CCD pixel data stream into a bulk RAM, and the subsequent transfer of this data to the instrument computer. The CCD/dewar controller generates the waveforms for clocking the CCD, digitizes the pixel data, and transmits it via high-speed link to the data capture computer. It is also responsible for monitoring and controlling the dewar temperature and cryogen levels. Given the number of different types of processors and high-speed data links employed in both systems, a major emphasis of this paper will be on the various forms of interprocessor communications utilized for data transfer and distributed process synchronization.

Kibrick, R. I.↗

BECN2 interacts with ATG14 through a metastable coiled-coil to mediate autophagy: BECN2 CCD Structure and Interaction with ATG14

ATG14 binding to BECN/Beclin homologs is essential for autophagy, a critical catabolic homeostasis pathway. Here, we show that the α-helical, coiled-coil domain (CCD) of BECN2, a recently identified mammalian BECN1 paralog, forms an antiparallel, curved homodimer with seven pairs of nonideal packing interactions, while the BECN2 CCD and ATG14 CCD form a parallel, curved heterodimer stabilized by multiple, conserved polar interactions. Compared to BECN1, the BECN2 CCD forms a weaker homodimer, but binds more tightly to the ATG14 CCD. Mutation of nonideal BECN2 interface residues to more ideal pairs improves homodimer self-association and thermal stability. Unlike BECN1, all BECN2 CCD mutants bind ATG14, although more weakly than wild type. Thus, polar BECN2 CCD interface residues result in a metastable homodimer, facilitating dissociation, but enable better interactions with polar ATG14 residues stabilizing the BECN2:ATG14 heterodimer. These structure-based mechanistic differences in BECN1 and BECN2 homodimerization and heterodimerization likely dictate competitive ATG14 recruitment.

59 BASIC BIOLOGICAL SCIENCES↗

Large area CCD image sensors for space astronomy

The Defense Advanced Research Projects Agency (DARPA) has a substantial program to develop a 2200 x 2200 pixel CCD (Charge Coupled Device) mosaic array made up of 400 individual CCD's, 110 x 110 pixels square. This type of image sensor appeared to have application in space and ground-based astronomy. Under this grant a CCD television camera system was built which was capable of operating an array of 4 CCD's to explore the suitability of the CCD's to explore the suitability of the CCD for astronomical applications. Two individual packaged CCD's were received and evaluated. Evaluation of the basic characteristics of the best individual chips was encouraging, but the manufacturer found that their yield in manufacturing this design is two low to supply sufficient CDD's for the DARPA mosaic array. The potential utility of large mosaic arrays in astronomy is still substantial and continued monitoring of the manufacturers progress in the coming year is recommended.

Schwarzschild, M.↗

CCD correlated quadruple sampling processor

A correlated quadruple sampling processor for improved signal-to-noise ratio in the output of a charge-coupled device (CCD) is comprised of: switching means for momentarily clamping a CCD signal line at a first reference level A before a CCD data pulse and then obtaining a first data sample B with respect to the reference A during a CCD data pulse, and storing the positive sample B-A; switching means for momentarily clamping the CCD signal line a second time at the level C during the presence of the CCD data pulse and then obtaining a second data sample D with respect to the reference level C after the CCD data pulse, and storing the negative sample D-C; and means for obtaining the difference between the stored samples +(B-A) and -(D-C), thus increasing the net signal amplitude by a factor of about 2 while the noise would be increased by only a factor of square root of 2 since there will be no correlation in the noise between the double samples +(B-A) and -(D-C) effectively added.

Gaalema, S. D.↗

CCD TV focal plane guider development and comparison to SIRTF applications

It is expected that the SIRTF payload will use a CCD TV focal plane fine guidance sensor to provide acquisition of sources and tracking stability of the telescope. Work has been done to develop CCD TV cameras and guiders at Lick Observatory for several years and have produced state of the art CCD TV systems for internal use. NASA decided to provide additional support so that the limits of this technology could be established and a comparison between SIRTF requirements and practical systems could be put on a more quantitative basis. The results of work carried out at Lick Observatory which was designed to characterize present CCD autoguiding technology and relate it to SIRTF applications is presented. Two different design types of CCD cameras were constructed using virtual phase and burred channel CCD sensors. A simple autoguider was built and used on the KAO, Mt. Lemon and Mt. Hamilton telescopes. A video image processing system was also constructed in order to characterize the performance of the auto guider and CCD cameras.

Rank, David M.↗

Mosaic CCD method: A new technique for observing dynamics of cometary magnetospheres

On April 29, 1990, the plasma tail of Comet Austin was observed with a CCD camera on the 105-cm Schmidt telescope at the Kiso Observatory of the University of Tokyo. The area of the CCD used in this observation is only about 1 sq cm. When this CCD is used on the 105-cm Schmidt telescope at the Kiso Observatory, the area corresponds to a narrow square view of 12 ft x 12 ft. By comparison with the photograph of Comet Austin taken by Numazawa (personal communication) on the same night, we see that only a small part of the plasma tail can be photographed at one time with the CCD. However, by shifting the view on the CCD after each exposure, we succeeded in imaging the entire length of the cometary magnetosphere of 1.6 x 10(exp 6) km. This new technique is called 'the mosaic CCD method'. In order to study the dynamics of cometary plasma tails, seven frames of the comet from the head to the tail region were twice imaged with the mosaic CCD method and two sets of images were obtained. Six microstructures, including arcade structures, were identified in both the images. Sketches of the plasma tail including microstructures are included.

Saito, T.↗