Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effort was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.

National Ignition Facility, X-ray diagnostic, X-ra↗

Time-resolved spectra of dense plasma focus using spectrometer, streak camera, and CCD combination

A time-resolving spectrographic instrument has been assembled with the primary components of a spectrometer, image-converting streak camera, and CCD recording camera, for the primary purpose of diagnosing highly dynamic plasmas. A collection lens defines the sampled region and couples light from the plasma into a step index, multimode fiber which leads to the spectrometer. The output spectrum is focused onto the photocathode of the streak camera, the output of which is proximity-coupled to the CCD. The spectrometer configuration is essentially Czerny-Turner, but off-the-shelf Nikon refraction lenses, rather than mirrors, are used for practicality and flexibility. Only recently assembled, the instrument requires significant refinement, but has now taken data on both bridge wire and dense plasma focus experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the CCD development for the Dark Energy Spectroscopic Instrument

We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)(2)-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Consequences of CCD imperfections for cosmology determined by weak lensing surveys: from laboratory measurements to cosmological parameter bias

Weak gravitational lensing causes subtle changes in the apparent shapes of galaxies due to the bending of light by the gravity of foreground masses. By measuring the shapes of large numbers of galaxies (millions in recent surveys, up to tens of billions in future surveys) we can infer the parameters that determine cosmology. Imperfections in the detectors used to record images of the sky can introduce changes in the apparent shapes of galaxies, which in turn can bias the inferred cosmological parameters. In this paper we consider the effect of two widely discussed sensor imperfections: tree rings, due to impurity gradients that cause transverse electric fields in the charge-coupled devices (CCDs), and pixel size variation, due to periodic CCD fabrication errors. These imperfections can be observed when the detectors are subject to uniform illumination (flat-field images). We develop methods to determine the spurious shear and convergence (due to the imperfections) from the flat-field images. We calculate how the spurious shear when added to the lensing shear will bias the determination of cosmological parameters. We apply our methods to candidate sensors of the Large Synoptic Survey Telescope (LSST) as a timely and important example, analyzing flat-field images recorded with LSST prototype CCDs in the laboratory. We find that tree rings and periodic pixel size variation present in the LSST CCDs will introduce negligible bias to cosmological parameters determined from the lensing power spectrum, specifically w, Ω{sub m}, and σ{sub 8}.

79 ASTRONOMY AND ASTROPHYSICS↗

A Python Module for Storing CCD Images with openPMD (openPMD-CCD) v0.1.0

openPMD is an open meta-data schema that provides meaning and self-description to data sets in science and engineering. The openPMD-CCD software module adds interfaces to organize camera (CCD) images in hierarchical data files. This software provides modern I/O storage formats from high-performance computing and provides bindings for integration into experimental control systems, e.g. via Python 3 and LabView 2020.

Gonsalves, AnthonyJ↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BECN2 interacts with ATG14 through a metastable coiled-coil to mediate autophagy: BECN2 CCD Structure and Interaction with ATG14

ATG14 binding to BECN/Beclin homologs is essential for autophagy, a critical catabolic homeostasis pathway. Here, we show that the α-helical, coiled-coil domain (CCD) of BECN2, a recently identified mammalian BECN1 paralog, forms an antiparallel, curved homodimer with seven pairs of nonideal packing interactions, while the BECN2 CCD and ATG14 CCD form a parallel, curved heterodimer stabilized by multiple, conserved polar interactions. Compared to BECN1, the BECN2 CCD forms a weaker homodimer, but binds more tightly to the ATG14 CCD. Mutation of nonideal BECN2 interface residues to more ideal pairs improves homodimer self-association and thermal stability. Unlike BECN1, all BECN2 CCD mutants bind ATG14, although more weakly than wild type. Thus, polar BECN2 CCD interface residues result in a metastable homodimer, facilitating dissociation, but enable better interactions with polar ATG14 residues stabilizing the BECN2:ATG14 heterodimer. These structure-based mechanistic differences in BECN1 and BECN2 homodimerization and heterodimerization likely dictate competitive ATG14 recruitment.

59 BASIC BIOLOGICAL SCIENCES↗

Poisson_CCD: A dedicated simulator for modeling CCDs

A dedicated simulator, Poisson_CCD, has been constructed which models astronomical CCDs by solving Poisson’s equation numerically and simulating charge transport within the CCD. The potentials and free carrier densities within the CCD are self-consistently solved for, giving realistic results for the charge distribution within the CCD storage wells. The simulator has been used to model the CCDs that are being used to construct the LSST digital camera. The simulator output has been validated by comparing its predictions with several different types of CCD measurements, including astrometric shifts, brighter-fatter induced pixel–pixel covariances, saturation effects, and diffusion spreading. The code is open source and freely available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-energy radiative backgrounds in CCD-based dark-matter detectors

The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles as they pass through detector materials and perform a detailed simulation to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected at Fermilab near the MINOS cavern. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination radiation; photo-absorption in the bulk, backside layer, pitch adapter, and epoxy; the photon reflection and refraction at interfaces; thin-film interference; the roughness of the interfaces; the dynamics of charges produced in the highly doped CCD-backside-layers; and the partial charge collection on the CCD backside. We consider several systematic uncertainties, notably those stemming from the backside modeling, which we estimate with a “fiducial” and an “extreme” charge-diffusion model, with the former model being preferred due to better agreement with partial-charge collection data. We find that Cherenkov photons constitute about 30% of the observed single-electron events for both diffusion models; radiative recombination contributes negligibly to the event rate for the fiducial model, although it can dominate over Cherenkov for the extreme model. We also estimate the fraction of 2-electron events that arise from 1-electron event coincidences in the same pixel, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for both radiative and non-radiative backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements.

79 ASTRONOMY AND ASTROPHYSICS↗

Masking a CCD camera allows multichord charge exchange spectroscopy measurements at high speed on the DIII-D tokamak

Charge exchange spectroscopy is one of the standard plasma diagnostic techniques used in tokamak research to determine ion temperature, rotation speed, particle density, and radial electric field. Configuring a charge coupled device (CCD) camera to serve as a detector in such a system requires a trade-off between the competing desires to detect light from as many independent spatial views as possible while still obtaining the best possible time resolution. High time resolution is essential, for example, for studying transient phenomena such as edge localized modes. By installing a mask in front of a camera with a 1024 x 1024 pixel CCD chip, we are able to acquire spectra from eight separate views while still achieving a minimum time resolution of 0.2 ms. The mask separates the light from the eight spectra, preventing spatial and temporal cross talk. A key part of the design was devising a compact translation stage which attaches to the front of the camera and allows adjustment of the position of the mask openings relative to the CCD surface. The stage is thin enough to fit into the restricted space between the CCD camera and the spectrometer endplate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of three-wavelength CCD image pyrometer used for the temperature field measurements of continuous casting billets

This paper develops an imaging based three-color pyrometer for the monitoring of temperature distribution in a continuous casting billet. A novel optical device, together with an embedded electronic system, is designed to sequentially collect a dark image and three thermal images with specified wavelengths on a same monochromatic charge-coupled-device (CCD). The three thermal images provide the basis for the determination of target temperature, while the dark image is used to online eliminate the dark noise of CCD with a differential method. This image pyrometer is not only independent of target emissivity but also overcomes the dissimilarity of measuring accuracy between the micro-sensors of CCD resulted from the non-uniformity of pixels’ intensity response and the vignetting of optical system. Furthermore, a precise two-color temperature field measuring model on the CCD pyrometer is established, based on which a self-adaptive light-integration mechanism is presented. Compared with the traditional fixed light-integration method, the measuring range of the pyrometer is greatly extended and its sensitivity in low temperature segment is improved. The test results in a steel factory demonstrate that the pyrometer is capable of meeting the requirement of surface temperature measurements about casting billets. Reliability and accuracy of measurement results are also discussed herein.

42 ENGINEERING↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-frame, megahertz CCd imager

To record high-speed, explosively driven, events, a high efficiency, high speed, imager has been fabricated which is capable of framing rates of 2 MHz. This device utilizes a 512 x 512 pixel charge coupled device (CCD) with a 25cm{sup 2} active area, and incorporates an electronic shutter technology designed for back-illuminated CCD's, making this the largest and fastest back-illuminated CCD in the world. Characterizing an imager capable of this frame rate presents unique challenges. High speed LED drivers and intense radioactive sources are needed to perform the most basic measurements. We investigate properties normally associated with single-frame CCD's such as read noise, full-well capacity, sensitivity, signal to noise ratio, linearity and dynamic range. In addition, we investigate several properties associated with the imager's multi-frame operation such as transient frame response and frame-to-frame isolation while contrasting our measurement techniques and results with more conventional devices.

47 OTHER INSTRUMENTATION↗

SU-F-J-190: Time Resolved Range Measurement System Using Scintillator and CCD Camera for the Slow Beam Extraction

Purpose: To investigate the time structure of the range, we have verified the rang shift due to the betatron tune shift with several synchrotron parameters. Methods: A cylindrical plastic scintillator block and a CCD camera were installed on the black box. Using image processing, the range was determined the 80 percent of distal dose of the depth light distribution. The root mean square error of the range measurement using the scintillator and CCD system is about 0.2 mm. Range measurement was performed at interval of 170 msec. The chromaticity of the synchrotron was changed in the range of plus or minus 1% from reference chromaticity in this study. All of the particle inside the synchrotron ring were extracted with the output beam intensity 1.8×10{sup 8} and 5.0×10{sub 7} particle per sec. Results: The time strictures of the range were changed by changing of the chromaticity. The reproducibility of the measurement was sufficient to observe the time structures of the range. The range shift was depending on the number of the residual particle inside the synchrotron ring. Conclusion: In slow beam extraction for scanned carbon-ion therapy, the range shift is undesirable because it causes the dose uncertainty in the target. We introduced the time-resolved range measurement using scintillator and CCD system. The scintillator and CCD system have enabled to verify the range shift with sufficient spatial resolution and reproducibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEARCHING FOR BULK MOTIONS IN THE INTRACLUSTER MEDIUM OF MASSIVE, MERGING CLUSTERS WITH CHANDRA CCD DATA

We search for bulk motions in the intracluster medium (ICM) of massive clusters showing evidence of an ongoing or recent major merger with spatially resolved spectroscopy in Chandra CCD data. We identify a sample of six merging clusters with >150 ks Chandra exposure in the redshift range 0.1 < z < 0.3. By performing X-ray spectral analysis of projected ICM regions selected according to their surface brightness, we obtain the projected redshift maps for all of these clusters. After performing a robust analysis of the statistical and systematic uncertainties in the measured X-ray redshift z{sub X}, we check whether or not the global z{sub X} distribution differs from that expected when the ICM is at rest. We find evidence of significant bulk motions at more than 3σ in A2142 and A115, and less than 2σ in A2034 and A520. Focusing on single regions, we identify significant localized velocity differences in all of the merger clusters. We also perform the same analysis on two relaxed clusters with no signatures of recent mergers, finding no signs of bulk motions, as expected. Our results indicate that deep Chandra CCD data enable us to identify the presence of bulk motions at the level of v{sub BM} > 1000 km s{sup −1} in the ICM of massive merging clusters at 0.1 < z < 0.3. Although the CCD spectral resolution is not sufficient for a detailed analysis of the ICM dynamics, Chandra CCD data constitute a key diagnostic tool complementing X-ray bolometers on board future X-ray missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

Charge Coupled Devices (CCD) are being used for reactor neutrino experiments and have already demonstrated their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model (BSM) physics in a nuclear reactor has been evaluated for different benchmark scenarios. Here, we report the first installation of a 2-g Skipper-CCD inside the containment building of a 2 GW th nuclear power plant and analyze its performance throughout its first 18 months of operation. The sensor was successfully deployed at Atucha II, in Argentina, 12 meters away from the center of the reactor core. We discuss the challenges involved in the commissioning of the detector and present data acquired during reactor ON and reactor OFF periods, with the sensor functioning with a sub-electron readout noise of 0.17 e - . Based on an exposure of 56.8 g day reactor ON and two reactor OFF data sets with a total exposure of 118.1 g day we characterize the system and evaluate the sensitivity to CEvNS. We achieved a background rate of 33 kdru and a low threshold of 45 eV ee . The ongoing efforts to improve sensitivities to CEvNS and BSM interaction are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗