Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Causal CCF Parameter Estimations 2020

This report documents the quantitative results of the causal common-cause failure (CCF) parameter estimations for the failure cause groups “component,” “design,” “environment,” “human,” and “other,” based on CCF data through 2020 in the U.S. Nuclear Regulatory Commission (NRC) CCF database: https://rads.inl.gov/Pages/CCF.aspx. This report utilizes the same data period (2006–2020) and CCF templates as INL/EXT-21-62940, Revision 1, CCF Parameter Estimations, 2020 Update. The 2015 causal CCF prior distributions for the specific failure cause groups (instead of the 2015 generic CCF prior distributions) were used in this report to estimate the associated causal CCF parameters. All the 2015 causal CCF prior distributions and generic CCF prior distributions were developed in INL/EXT-21-43723, Developing Generic Prior Distributions for Common Cause Failure Alpha Factors and Causal Alpha Factors, using CCF data from 1997 to 2015. These quantitative results were developed to support the causal alpha factor model and should be used as appropriate in probabilistic risk assessment (PRA) studies such as the NRC Significance Determination Process for commercial nuclear power plants in the United States.

99 GENERAL AND MISCELLANEOUS↗

CCF Parameter Estimations, 2020 Update

This report documents the quantitative results of the common-cause failure (CCF) data collection effort (which included data through 2020) and summarizes the results of the parameter estimation quantification process performed on CCF data in the U.S. Nuclear Regulatory Commission (NRC) CCF database. This is the 2020 update to NUREG/CR-5497, updating data and parameter estimations for CCFs. This release, CCF Parameter Estimation 2020, reflects the CCF data contained within the CCF database, https://rads.inl.gov/Pages/CCF.aspx, by executing (in August 2021) the CCF query rules in the folder SPAR Rules 2020. The data covers the period from 1/1/2006 to 12/31/2020, the most recent 15-year period in which data are available. The use of the most recent rolling 15-year data in parameter estimation differs from previous updates, in which 1/1/1997 was used as the starting date (e.g., 1/1/1997 to 12/31/2015 for the 2015 update, 1/1/1997 to 12/31/2012 for the 2012 update). The new date range (i.e., the most recent 15-year period), was selected for this CCF update so as to be consistent with the date range chosen for the component reliability parameter estimation, and with the effort to include sufficient data for analysis while simultaneously reflecting the most recent industry performance. These results are appropriate for use in probabilistic risk assessment (PRA) studies, including the Standardized Plant Analysis Risk (SPAR) models of commercial nuclear power plants (NPPs) in the U.S. This update may be referred as: U.S. Nuclear Regulatory Commission, "CCF Parameter Estimations, 2020 Update," https://nrcoe.inl.gov/publicdocs/CCF/ccfparamest2020.pdf, November 2021.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Qualitative Assessment of Current CCF Guidance Based on a Review of Safety System Digital Implementation Changes with Evolving Technology

The US Nuclear Regulatory Commission (NRC) is initiating a new rulemaking project to develop a digital system common-cause failure (CCF) rule. This rulemaking will review and modify or affirm the NRC's current digital system CCF policy as discussed in the Staff Requirements Memorandum to the Secretary of the Commission, Office of the NRC (SECY) 93-087, Policy, Technical, and Licensing Issues Pertaining to Evolutionary and Advanced Light Water Reactor (ALWR) Designs, and Branch Technical Position (BTP) 7-19, Guidance on Evaluation of Defense-in-Depth and Diversity in Digital Computer-Based Instrumentation and Control Systems, as well as Chapter 7, Instrumentation and Controls, in NRC Regulatory Guide (NUREG)-0800, Standard Review Plan for Review of Safety Analysis Reports for Nuclear Power Plants (ML033580677). The Oak Ridge National Laboratory (ORNL) is providing technical support to the NRC staff on the CCF rulemaking, and this report is one of several providing the technical basis to inform NRC staff members. For the task described in this report, ORNL examined instrumentation and controls (I&C) technology implementations in nuclear power plants in the light of current CCF guidance. The intent was to assess whether the current position on CCF is adequate given the evolutions in digital safety system implementations and, if gaps in the guidance were found, to provide recommendations as to how these gaps could be closed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A qualitative assessment of current CCF guidance based on a review of safety system digital implementation changes with evolving technology - 148

This paper is a summary of a study performed in support of the US Nuclear Regulatory Commission (NRC) to evaluate current policy on software common-cause failure (CCF). The study reported in this paper is one of several that contributed to the technical basis to inform NRC staff. The study first reviewed policies and assessment guidance as discussed in the Staff Requirements Memorandum to the Secretary of the Commission, Office of the NRC (SECY) 93-087, Policy, Technical, and Licensing Issues Pertaining to Evolutionary and Advanced Light Water Reactor (ALWR) Designs, and Branch Technical Position (BTP) 7-19, Guidance on Evaluation of Defense-in-Depth and Diversity in Digital Computer-Based Instrumentation and Control Systems, as well as Chapter 7, 'Instrumentation and Controls', in NUREG-0800, Standard Review Plan for Review of Safety Analysis Reports for Nuclear Power Plants. The study then examined instrumentation and controls (I and C) technology implementations in nuclear power plants in the light of current CCF guidance. The intent was to assess whether the current position on CCF remains appropriate given the evolutions in digital safety system implementations and, if gaps in the guidance were found, to provide recommendations as to how these gaps could be closed. The methodology adopted was to review the vendors' technology and software implementation processes for digital safety systems as technology evolved. The following three representative safety systems were selected to provide illustrative examples: - Eagle 21 was selected to represent vintage microprocessor-based technology used from the 1980's to mid-1990's, - TELEPERM XS (TXS) was selected to represent second generation microprocessor-based technology used from the mid-1990's to the 2000's, and - The advanced logic system (ALS) was selected to represent the latest trend of using technology based on field programmable gate arrays (FPGAs). Technology implementations were reviewed in light of the basic premise of the NRC in BTP 7-19 (Revision 6), that software-based or software-logic-based digital system development errors are a credible source of CCF and therefore are susceptible to CCF because identical copies of the software-based logic and architecture are present in redundant divisions of safety-related systems. BTP 7-19 categorizes firmware and logic developed from software-based development systems all under software. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation Between Existing and Improved CCF Modeling Using the NRC SPAR Models

Abstract: The NRC SPAR models currently employ the alpha factor common cause failure (CCF) methodology and model CCF for a group of redundant components as a single “rolled-up” basic event. These SPAR models will be updated to employ a more computationally intensive and accurate approach by expanding the CCF basic events for all active components to include all terms that appear in the Basic Parameter Model (BPM). A discussion is provided to detail the differences between the rolled-up common cause group (CCG) and expanded BPM adjustment concepts based on differences in core damage frequency and individual component importance measures. Lastly, a hypothetical condition is evaluated with a SPAR model to show the difference in results between the current adjustment method (rolled-up CCF events) and the newer method employing all of the expanded terms in the BPM. The event evaluation on the SPAR model employing the expanded terms will be solved using the graphical evaluation module (GEM) and the proposed method discussed in Reference 1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Separation and Transition on a CCF: Experimental Campaigns

Several experimental campaigns have been conducted across a number of Mach-6 facilities on the hypersonic flow around a CCF (CCF) geometry with a 5° half-angle cone and a 12° half-angle flare. These experiments were conducted as part of the NATO STO Research Task Group AVT-346, which is focused on predicting hypersonic boundary-layer transition on complex geometries. Two conventional wind tunnels (AFRL M6LT and ONERA R2Ch) and one quiet tunnel (Purdue BAM6QT) were used to test the same CCF geometry and to study the instabilities in both the boundary layer in the attached parts of the flow and the shear layer above the axisymmetric separation bubble near the cylinder-cone junction. Two nosetip radii (one nominally sharp and one blunt with a 5 mm radius) were tested. For the sharp nosetip case, there was a great deal of agreement between the measurements of both second-mode and shear-layer instabilities across the two conventional facilities. However, the measured spectra for the blunt nosetip case showed more significant differences between the two tunnels, potentially due to an alternate dominant instability mechanism coupled with the variations in the freestream noise spectra. The quiet facility resulted in a flow that remained laminar to much higher freestream unit Reynolds numbers, as well as in instability measurements that had more distinct spectral peaks for the sharp tip case and broadband rises for the blunt one. The instability mechanisms at play in the sharp quiet case were found to be the same as those in the conventional facilities.

Boundary Layer Transition↗

Common cause failure (CCF): a path to quantitative success - 134

In the development of I and C systems for nuclear plants it is critical to validate a defense in depth strategy through a thorough and complete reliability analysis program. An emerging issue is how to define and use a quantitative estimation of CCF in a system analysis. Industry standards provide insight but not necessarily a comprehensive approach. One solution is to leverage existing modeling techniques with a unique insertion of CCF probabilities. A relatively simple approach will be provided using reliability block diagrams. Three specific areas that will be explored include: 1. Definition of hardware CCF; 2. Quantitative estimation in a simple system; 3. Quantitative estimation in a complex system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A fraction of neurofibromin interacts with PML bodies in the nucleus of the CCF astrocytoma cell line

Highlights: Black-Right-Pointing-Pointer We validate the use of specific anti-Nf1 antibodies for immunofluorescence studies. Black-Right-Pointing-Pointer We detect Nf1 in the cytoplasm and nucleus of CCF cells. Black-Right-Pointing-Pointer We demonstrate that Nf1 partially colocalizes with PML nuclear bodies. Black-Right-Pointing-Pointer We demonstrate that there is a direct interaction between a fraction of Nf1 and the PML bodies. -- Abstract: Neurofibromatosis type 1 is a common genetic disease that causes nervous system tumors, and cognitive deficits. It is due to mutations within the NF1 gene, which encodes the Nf1 protein. Nf1 has been shown to be involved in the regulation of Ras, cAMP and actin cytoskeleton dynamics. In this study, using immunofluorescence experiments, we have shown a partial nuclear localization of Nf1 in the astrocytoma cell line: CCF and we have demonstrated that Nf1 partially colocalizes with PML (promyelocytic leukemia) nuclear bodies. A direct interaction between Nf1 and the multiprotein complex has further been demonstrated using 'in situ' proximity ligation assay (PLA).

60 APPLIED LIFE SCIENCES↗

Central Computational Facility CCF communications subsystem options

A MITRE study which investigated the communication options available to support both the remaining Central Computational Facility (CCF) computer systems and the proposed U1108 replacements is presented. The facilities utilized to link the remote user terminals with the CCF were analyzed and guidelines to provide more efficient communications were established.

Hennigan, K. B.↗

Alternative hypothesis for the origin of CCF xenon

The relative abundances and origins of the xenon isotopes found in carbonaceous meteorites are discussed. It is proposed that carbonaceous-chondrite-fission (CCF) xenon is not caused by fission, but is the direct result of a modified r-process nucleosynthesis which produces a peak at Z = 54 and N = 82. The xenon produced in this way would have been trapped in dust grains which were subsequently incorporated in the solar system with minimal degassing.

Black, D. C.↗

Capillary Channel Flow (CCF) EU2-02 on the International Space Station (ISS): An Experimental Investigation of Passive Bubble Separations in an Open Capillary Channel

It would be signicantly easier to design fluid systems for spacecraft if the fluid phases behaved similarly to those on earth. In this research an open 15:8 degree wedge-sectioned channel is employed to separate bubbles from a two-phase flow in a microgravity environment. The bubbles appear to rise in the channel and coalesce with the free surface in much the same way as would bubbles in a terrestrial environment, only the combined effects of surface tension, wetting, and conduit geometry replace the role of buoyancy. The host liquid is drawn along the channel by a pump and noncondensible gas bubbles are injected into it near the channel vertex at the channel inlet. Control parameters include bubble volume, bubble frequency, liquid volumetric flow rate, and channel length. The asymmetrically confined bubbles are driven in the cross-flow direction by capillary forces until they at least become inscribed within the section or until they come in contact with the free surface, whereupon they usually coalesce and leave the flow. The merging of bubbles enhances, but does not guarantee, the latter. The experiments are performed aboard the International Space Station as a subset of the Capillary Channel Flow experiments. The flight hardware is commanded remotely and continuously from ground stations during the tests and an extensive array of experiments is conducted identifying numerous bubble flow regimes and regime transitions depending on the ratio and magnitude of the gas and liquid volumetric flow rates. The breadth of the publicly available experiments is conveyed herein primarily by narrative and by regime maps, where transitions are approximated by simple expressions immediately useful for the purposes of design and deeper analysis.

fluid dynamics↗

REPRESENTING COMMON-CAUSE FAILURES IN THE SAPHIRE SOFTWARE

Currently, the risk analysis software SAPHIRE has implemented a common-cause failure (CCF) module to represent standard CCF methods such as alpha-factor and multiple Greek letter approaches. However, changes to SAPHIRE are required to support the Nuclear Regulatory Commission’s 2007 “Risk Assessment Standardization Project” CCF analysis guidance for events assessment. This guidance provides an outline of how both the nominal CCF probabilities and conditional (e.g., after a redundant component has failed) CCF probabilities should be calculated. Based upon user-provided input and extending the limitations in the current version of SAPHIRE, the CCF module calculations will be made consistent with the new guidance. The CCF modifications will involve changes to (1) the SAPHIRE graphical user interface directing how end-users and modelers interface with PRA models and (2) algorithmic changes as required. Included in the modifications will be the possibility to treat CCF probability adjustments based upon failure types (e.g., independent versus dependent) and failure modes (e.g., failure-to-run versus failure-to-start). In general, SAPHIRE is being modified to allow the risk analyst to define a CCF object. This object is defined in terms of a basic event. For the CCF object, the analyst would need to specify a minimal set of information, including: - The number of redundant components - The failure criteria (how many component have to fail) - The CCF model type (alpha-factor, MGL, or beta-factor) - The parameters (e.g., the alpha-factors) associated with the model - Staggered or non-staggered testing assumption - Default level of detail (expanded, showing all of the specific failure combinations, or not) This paper will outline both the theory behind the probabilistic calculations and the resulting implementation in the SAPHIRE software.

97 MATHEMATICS AND COMPUTING↗

Taxonomy for Common-Cause Failure Vulnerability and Mitigation

Applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The potential for CCF vulnerability inhibits I&C modernization, thereby challenging the long-term sustainability of existing plants. For new plants and advanced reactor concepts, concern about CCF vulnerability in highly integrated digital I&C systems imposes a design burden that results in higher costs and increased complexity. The regulatory uncertainty in determining which mitigation strategies will be acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutions devised for existing plants. To address the conditions that constrain the transition to digital I&C technology by the US nuclear industry, crosscutting research is needed to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for nuclear power plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is investigating mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive basis to qualify digital technology for nuclear power applications. This report documents the development of a CCF taxonomy. The basis for the CCF taxonomy was generated by determining consistent terminology and establishing a classification approach. The terminology is based on definitions from standards, guides, and relevant nuclear power industry technical reports. The classification approach is derived from identified classification schemes focused on I&C systems and key characteristics, including failure modes. The CCF taxonomy provides the basis for a systematic organization of key systems aspects relevant to analyzing the potential for CCF vulnerability and the suitability of mitigation techniques. Development of an effective CCF taxonomy will help to provide a framework for establishing the objective analysis and assessment capabilities desired to facilitate rigorous identification of fault types and triggers that are the fundamental elements of CCF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Impacts of common cause failure regulatory requirements on protection system architectures - 304

Regulatory-based design considerations for potential common cause failures (CCF) in digital instrumentation and control (I and C) systems have evolved over time and have impacted the development of protection system I and C architectures. The single failure criterion used to be the main design driver for a protection system I and C architecture and resulted in the familiar four-fold and three-fold system architectures. The single failure criterion has now been replaced by the conservative assumptions associated with digital CCF concerns (i.e., assumed digital CCF coincident with an anticipated operational transient or postulated accident) which are classified as 'beyond design basis events' by regulatory authorities. It is unusual for a beyond design basis event to be the controlling factor for a safety system design but that is now the reality for I and C system designers. The preferred regulatory solution is to introduce diversity into I and C system designs to guard against the general concern of digital CCF. However, the lack of clear criteria on how to define sufficient diversity (i.e., how much, what kind, and whether it is linked to identified digital CCF vulnerabilities) had led to more complex I and C architectures. The trend has been towards lengthy and more difficult reviews for the treatment of digital CCF vulnerabilities and I and C system architectures because of the subjective definition of digital CCF vulnerabilities and the lack of clear acceptance criteria for diversity strategy. Improvement in the treatment of digital CCF is needed to reverse the trend of increased I and C system architecture complexity and longer regulatory reviews. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗