Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEBAF ACCELERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

CEBAF accelerator achievements

In the past decade, nuclear physics users of Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) have benefited from accelerator physics advances and machine improvements. As of early 2011, CEBAF operates routinely at 6 GeV, with a 12 GeV upgrade underway. This article reports highlights of CEBAF's scientific and technological evolution in the areas of cryomodule refurbishment, RF control, polarized source development, beam transport for parity experiments, magnets and hysteresis handling, beam breakup, and helium refrigerator operational optimization.

43 PARTICLE ACCELERATORS↗

Alignment of the 12 Gev CEBAF Accelerator

Alignment of the 12 Gev CEBAF Accelerator Jefferson lab has just completed an upgrade to its CEBAF accelerator which allows for an increase in the energy of delivered beam from 6Gev to 12 Gev. The enhancements to the accelerator have included the addition of 10 new high performance cryomodules, and the removal, upgrade and refurbishment of almost 300 existing transport magnets. Outside of the main accelerator, a new experimental hall has been constructed, and the three existing halls are currently being upgraded to take advantage of the higher energies. For this project, a new survey network has been measured and almost every element in the accelerator has been re-aligned. Commissioning of the accelerator took place at the beginning of this year, during the course of which, it became apparent that there was a significant difference between the expected and the actual path length in the machine. This paper describes the measurements taken and analysis used to try and understand this situation.

Curtis, Christopher↗

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 l/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~5 , compared to the original configuration. In conclusion, the new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CEBAF Accelerator Tunnel Robot Project

Advancements in the field of robotics allow for the use of remotely controlled robots to perform tasks that have typically required human intervention. Jefferson Lab has explored the possibilities of robots placed in the accelerator tunnel to perform remote inspections that would otherwise require powering down equipment and completing lengthy radiological surveys that impact beam operations. A robotic solution ? driven by a human operator ? could not only reduce accelerator down time but also support the Lab's radiation exposure policy (known as "ALARA" - As Low As Reasonably Acceptable) by handling routine tunnel and beamline investigations in place of a human being. However, operating a remote device in a radioactive, high electronic-noise area is not a trivial task and drop-in solutions are rarely as simple as they seem. We will present the past prototypes that were tested as well follow-on technology developed from the project. We will also briefly survey current applications of robots at accelerator facilities with an eye toward future applications.

McGuckin, Theodore↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

The Jefferson Lab program: From 6 GeV operations to the 12 GeV upgrade

The Thomas Jefferson National Laboratory and the CEBAF accelerator operated for more than a decade, running a comprehensive scientific program that improved our understanding of the strong interaction. The facility is now moving toward an upgrade of the machine, from 6 to 12 GeV; a new experimental hall will be added and the equipment of the three existing halls will be enhanced. In this contribution some selected results from the rich physics program run at JLab, as well as the prospects for the near future, will be presented.

43 PARTICLE ACCELERATORS↗

Overview of the recent results from CLAS

An overview of the recent results obtained at the Thomas Jefferson Laboratory on the study of the nucleon internal structure is presented, with main focus on the CLAS measurements of the Transverse Momentum Dependent partonic functions. The JLab with its CEBAF accelerator and the three experimentals halls is a Laboratory dedicated to the study of the hadronic physics with electromagnetic probes in a large variety of aspects. The physics program extends from typical nuclear effects like long range correlations in nuclei to the study of the short distance vacuum structure in parity violating experiments. In recent years, a big part of the physics program was devoted to the study of the Transverse Momentum Dependent distribution functions, new functions introduced to describe the internal structure of the nucleon. Studies of TMDs at JLab and in other laboratories have shown sizeable effects due to transverse motion of the quarks inside the nucleon, but also have open questions. These questions need to be addressed in a new generation of experiments, poviding higher precisions experimental data, and with new analysis techniques, necessary to unfold fundamental properties from the measured obsevables.

43 PARTICLE ACCELERATORS↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

OVERVIEW AND STATUS OF THE 12 GeV CRYOGENIC SYSTEM UPGRADE AT JLAB

As part of the planned Jefferson Laboratory's electron accelerator (CEBAF) power upgrade, ten additional superconducting RF cryomodules will be added to its accelerator linacs. Although physically the same size as each of the original 40 linac cryomodules, each new cryomodule will have approximately 4 times the acceleration power. To support the additional cryomodule heat loads generated, the existing 2 K, 4600 W Central Helium Liquefier (CHL) plant capacity will be doubled to a total of 9200 W at 2 K plus 24,000 W at 35 K for shield loads. The specified base line process cycle has been modeled after the laboratory's 'Ganni Helium Cycle' process technology. In addition, a fourth physics experimental 'Hall D' will be constructed which will have an additional stand alone 200 W at 4 K helium cryogenic plant. In October of 2008, Jefferson Laboratory (JLab) received approval for project 'Critical Decision 3' construction phase status from the US Department of Energy. An overview of the planned cryogenic systems and current design baseline as it relates to operations will be presented.

42 ENGINEERING↗

Introduction to Ingot Niobium

Superconducting radiofrequency (SRF) technology using niobium accelerating cavities was first applied at large scale in the recirculating electron linear accelerator CEBAF—the Continuous Electron Beam Accelerator Facility in Newport News, Virginia, USA, at what is now called Thomas Jefferson National Accelerator Facility, or Jefferson Lab. Building on the high quality factors and peak magnetic fields found in low residual resistivity ratio (low-RRR) solid niobium in the 1970s, Jefferson Lab has reintroduced ingot niobium technology. High tantalum content in ingot niobium is not expected to negatively impact cavity performance, but will reduce the cost of accelerator structures considerably. Optimized low-cost CW linear accelerators built with ingot niobium will show the way for future R&D and industrial applications. This paper portrays the Jefferson Lab SRF context, reviews the early history of ingot niobium technology from over a third of a century ago, explains the technical advantages of that technology's recent reintroduction, and presents the outlook for further development.

43 PARTICLE ACCELERATORS↗

SRF CAVITY PERFORMANCE OVERVIEW FOR THE 12 GeV UPGRADE

The CEBAF accelerator, a recirculating CW electron accelerator that is currently operating at Jefferson Laboratory, is in the process of having 10 new cryomodules installed to allow for the maximum beam energy to be increased from 6 GeV to 12 GeV. This upgrade required the fabrication, processing and RF qualification of 80, seven cell elliptical SRF cavities, a process that was completed in February 2012. The RF performance achieve in the vertical testing dewars has exceeded the design specification by {approx}25% and is a testament to the cavity design and processing cycle that has been implemented. This paper will provide a summary of the cavity RF performance in the vertical tests, as well as review the overall cavity processing cycle and duration for the project.

43 PARTICLE ACCELERATORS↗

Introduction to Ingot Niobium

Superconducting radiofrequency (SRF) technology using niobium accelerating cavities was first applied at large scale in the recirculating electron linear accelerator CEBAF--the Continuous Electron Beam Accelerator Facility in Newport News, Virginia, USA, at what is now called Thomas Jefferson National Accelerator Facility, or Jefferson Lab. Building on the high quality factors and peak magnetic fields found in low residual resistivity ratio (low-RRR) solid niobium in the 1970s, Jefferson Lab has reintroduced ingot niobium technology. High tantalum content in ingot niobium is not expected to negatively impact cavity performance, but will reduce the cost of accelerator structures considerably. Optimized low-cost CW linear accelerators built with ingot niobium will show the way for future R and D and industrial applications. This paper portrays the Jefferson Lab SRF context, reviews the early history of ingot niobium technology from over a third of a century ago, explains the technical advantages of that technology's recent reintroduction, and presents the outlook for further development.

36 MATERIALS SCIENCE↗

Upgrade of CEBAF from 6 Gev To 12 Gev: Status

The CEBAF accelerator is being upgraded from 6 GeV to 12 GeV by the US Department of Energy. The accelerator upgrade is being done within the existing tunnel footprint. The accelerator upgrade includes: 10 new srfbased high-performance cryomodules plus RF systems, doubling the 2K helium plant's capability, upgrading the existing beamlines to operate at nearly double the original performance envelope, and adding a beamline to a new experimental area. Construction is over 75% complete with final completion projected for late FY13. Details of the upgrade and status of the work will be presented.

43 PARTICLE ACCELERATORS↗

The CEBAF Element Database and Related Operational Software

The newly commissioned 12GeV CEBAF accelerator relies on a flexible, scalable and comprehensive database to define the accelerator. This database delivers the configuration for CEBAF operational tools, including hardware checkout, the downloadable optics model, control screens, and much more. The presentation will describe the flexible design of the CEBAF Element Database (CED), its features and assorted use case examples.

43 PARTICLE ACCELERATORS↗

JLAB Electron Driver Capabilities

Several schemes have been proposed for adding a positron beam option at the Continuous Electron Beam Facility (CEBAF) at Jefferson Laboratory (JLAB). They involve using a primary beam of electrons or gamma rays striking a target to produce a positron beam. At JLAB electron beams are produced and used in two different accelerators, CEBAF and the JLAB FEL (Free Electron Laser). Both have low emittance and energy spread. The CEBAF beam is polarized. The FEL beam is unpolarized but the injector can produce a higher current electron beam. In this paper we describe the characteristics of these beams and the parameters relevant for positron production.

43 PARTICLE ACCELERATORS↗

Electron Spin Rotation And Matching Scheme For ELIC, A High-Luminosity Ring-Ring Electron-Ion Collider

A unique design feature of a polarized Electron-Ion Collider (ELIC) based on CEBAF is its Figure-8 shaped storage rings for both electrons and ions, which significantly simplifies beam polarization maintenance and manipulation. The CEBAF accelerator is used as a full energy injector of polarized electron beams into the electron storage ring. While electron polarization is maintained vertical in arcs of the ring, a stable longitudinal spin at four collision points is achieved through vertical crossing bending magnets, solenoid spin rotators, and horizontal orbit bends. Spin matching technique needs to be implemented in order to enhance quantum self-polarization and minimize depolarization effects. In this paper, we also discuss several important issues related to the use of positron beams, radiative polarization and quantum depolarization effects, as well as spin in ELIC.

43 PARTICLE ACCELERATORS↗

e08-008: Exclusive study of deuteron electrodisintegration near threshold

The study of threshold electrodisintegration of and elastic scattering on the only stable two nucleon system, the deuteron, can reveal specific aspects of the N-N interaction. The simplicity of electrodisintegration along with the simplicity of the deuteron makes this study most appropriate for revealing these interactions. By using an incident beam of polarized electrons and by measuring the polarization of the recoiling proton, the ratio of the electric (G {sub E }) and magnetic (G {sub M }) form factors for d( e-vector ,e{sup ′} p-vector ) (and p( e-vector ,e{sup ′} p-vector )) reactions may be extracted. This experiment was conducted in Hall A at Jefferson Lab in Newport News, Virginia using a beam of polarized electrons provided by the CEBAF Accelerator incident on a liquid deuterium (and hydrogen) target. The scattered electron and the recoiling (polarized) proton were detected using the High Resolution Spectrometers of Hall A. To determine the polarization of the recoil proton, an analyzing material was placed perpendicular to the protons trajectory through the spectrometer, in front of a set of straw chambers. Due to the spin-orbit interactions involved in the scattering of the proton from the analyzer material, asymmetries seen in the distribution of events detected by these straw chambers reveal the polarization of the recoil proton. By tracking the spin procession of the polarized protons from the straw chambers back to the target, the transferred and induced polarization of the proton may be determined. The (double-spin) asymmetries observed in the straw chambers will first be studied for the well-known elastic p( e-vector ,e{sup ′} p-vector ) process and compared to the asymmetries for d( e-vector ,e{sup ′} p-vector )n(x{sub B}=1). The analysis will then be repeated to determine how these asymmetries change with increasing x {sub B }(to the kinematic limit for deuteron electrodisintegration).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beamline Insertions Manager at Jefferson Lab

The beam viewer system at Jefferson Lab provides operators and beam physicists with qualitative and quantitative information on the transverse electron beam properties. There are over 140 beam viewers installed on the 12 GeV CEBAF accelerator. This paper describes an upgrade consisting of replacing the EPICS-based system tasked with managing all viewers with a mixed system utilizing EPICS and high-level software. Most devices, particularly the beam viewers, cannot be safely inserted into the beam line during high-current beam operations. Software is partly responsible for protecting the machine from untimely insertions. The multiplicity of beam-blocking and beam-vulnerable devices motivates us to try a data-driven approach. The beamline insertions application components are centrally managed and configured through an object-oriented software framework created for this purpose. A rules-based engine tracks the configuration and status of every device, along with the beam status of the machine segment containing the device. The application uses this information to decide on which device actions are allowed at any given time.

43 PARTICLE ACCELERATORS↗