Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

Update on the CeC PoP 704 MHz 5-cell cavity cryomodule design and fabrication

A 5-cell SRF cavity operating at 704 MHz will be used for the Coherent Electron Cooling Proof of Principle (CeC PoP) system under development for the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The CeC PoP experiment will demonstrate the new technique of cooling proton and ion beams that may increase the beam luminosity in certain cases, by as much as tenfold. The 704 MHz cavity will accelerate 2 MeV electrons from a 112 MHz SRF gun up to 22MeV. This paper provides an overview of the design, the project status and schedule of the 704 MHz 5-cell SRF for CeC PoP experiment.

43 PARTICLE ACCELERATORS↗

CEC Quest: Long Duration Energy Storage Impact Analysis Tool

SAND2025-14389O CEC Quest is a Python tool with a user interface designed to analyze the greenhouse gas impacts of long-duration energy storage projects in California. The tool automates data collection from public sources and uses an Application Programming Interface (API) to enable users to download photovoltaic resource availability, marginal operating emissions rate, and utility rate data. It guides users in inputting parameters for a battery energy storage model and uploading site electrical load data, while also prompting for relevant analysis parameters like timestep and grid limits. CEC Quest performs monthly optimization of one year of data to assess impacts on the site’s electrical bill and the grid’s greenhouse gas emissions. Finally, it conducts a lifecycle analysis to evaluate changes over a defined quantification period, with results aggregated through automated report generation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David [Sandia National Lab. (SNL-CA), L↗

Effect of emittance on performance of CeC scheme

In coherent electron cooling (CeC) the ions get cooled because their longitudinal positions with respect to a wake created by each ion in the electron bunch is correlated with an ion’s energy. A typical characteristic length of a CeC wake is just a few microns. Therefore, the coupling of a transverse and a longitudinal motion of both electrons and ions in a cooler must be taken into account. Below we estimate an additional path-length’s spread through the cooler, which particles have due to transverse emittance.

43 PARTICLE ACCELERATORS↗

Materials Data on CeC by Materials Project

CeC is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Ce4+ is bonded to six equivalent C4- atoms to form a mixture of edge and corner-sharing CeC6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Ce–C bond lengths are 2.60 Å. C4- is bonded to six equivalent Ce4+ atoms to form a mixture of edge and corner-sharing CCe6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Requirements for CEC POP Machine Protection System

The requirements of CEC POP machine protection system are meant to prevent damage to a vacuum chamber by a missteered electron beam. In this example, beam energy = 22 MeV, Maximal bunch charge = 5 nC, Maximal repetition rate = 78 kHz, Normalized emittance = 5 mm mrad, Minimal β-function = 1 m. From this information the requirements of the protection system can be calculated by factoring the information into equations to find beam densities and temperature excursions.

43 PARTICLE ACCELERATORS↗

Development of a Regenerative Amplifier for the Coherent electron Cooling Proof of Principle Experiment (CeC-PoP) at RHIC

The commercial laser from NuPhoton that was used for the Coherent-electron-Cooling Proof of Principle (CeC-PoP) experiment in the past runs could not meet the tight specifications needed to demonstrate coherent electron cooling due to nonlinear effects inherent to fiber lasers operating at high pulse peak powers. To overcome these limitations, the Laser design was modified prior to the start of the 2018 RHIC run by introducing an additional amplifier stage that allows to take over the majority of the amplification process from the fiber amplifiers to keep the peak power in the fibers low and avoid the accumulation of nonlinear effects. This approach allows for a reduction of the output power of the NuPhoton laser to about 5% of the nominal power level avoiding the accumulation of nonlinear effect and leaving 6mW of unstable IR seed power (See Figure 2) for a subsequent amplification stage.

43 PARTICLE ACCELERATORS↗

Measurement of the Emittance for the CeC Project

Coherent Electron Cooling (CeC) experiment was carried out at RHIC [1]. It required small emi ance of 10-15 MeV electron beam with high peak current. In most cases the emi ance was measured by either quadrupole or solenoid scan. For a low-energy beam with high peak current the measurements are affected by space charge forces. To overcome these difficul es the pepper-pot [2,3] or slit scan [4] can be used.

43 PARTICLE ACCELERATORS↗

Commissioning of the 112 MHz SRF Gun and 500 MHz bunching cavities for the CeC PoP Linac

The Coherent electron Cooling Proof-of-Principle (CeC PoP) experiment at BNL includes a short electron linac. During Phase 1, a 112 MHz superconducting RF photo-emission gun and two 500 MHz normal conducting bunching cavities were installed and are under commissioning. The paper describes the Phase1 linac layout and presents commissioning results for the cavities and associated RF, cryogenic and other sub-systems

43 PARTICLE ACCELERATORS↗

Analysis of FEL-based CeC amplification at high gain limit

An analysis of Coherent electron Cooling (CeC) amplifier based on 1D Free Electron Laser (FEL) theory was previously performed with exact solution of the dispersion relation, assuming electrons having Lorentzian energy distribution. At high gain limit, the asymptotic behavior of the FEL amplifier can be better understood by Taylor expanding the exact solution of the dispersion relation with respect to the detuning parameter. In this work, we make quadratic expansion of the dispersion relation for Lorentzian energy distribution and investigate how longitudinal space charge and electrons’ energy spread affect the FEL amplification process.

43 PARTICLE ACCELERATORS↗

Wood-to-Fuel for California's Transportation Sector using Autothermal Pyrolysis: Kickoff Questionnaire for Benefits Analysis of CEC Projects

This is the first of three questionnaires that you will be asked to complete over the course of the agreement. Please type your responses directly into this document in the spaces below each question. Use as much space as you need; the form automatically creates more space within each response field. In addition, you may submit additional documents, spreadsheets, or other files. Acceptable filetypes are MS Word, MS Excel, and PDF. Additional files do not need to follow any particular format, unless specified by the particular questionnaire designed for your project.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Measurement of the Dispersion in the CeC Beamlines

The coherent electron cooling requires to match the relativistic factors of the hadron and electron beam within 10 -4 accuracy. Initial matching is based on the energy measurement of the electron beam using solenoid with accuracy about 10 -3 (the hadron relativistic factor can be found from the revolution frequency). Further matching is done with observation of the recombination rate with fine tuning based on the cooling rate. The last two steps require change of the electron energy which is achieved by change of the linac voltage. The interaction of the hadron and electron beams is affected by the transverse overlap of two beams. To minimize the effect, we need zero dispersion in the common section. The merge of the beams a dogleg transfer line is used containing two dipoles and three quadrupoles. The zeroing of dispersion is performed by settings of the quadrupoles. We have developed two ways to measure the dispersion. In the first mostly commonly used we change both dipoles by the same value creating the mismatch between the electron energy and bending magnet. In the compensated dogleg the position in the second dipole should not change, and the trajectory angle will change by the same amount as deflecting angle but in opposite direction. Therefore, the trajectory in the common section will not change. The value of the dispersion can be calculated from the beam displacement divided by the relative chang of the dipoles’ current. The second method is based on the change of the electron beam energy using linac. This method requires electron orbit alignment with linac axis to avoid beam steering. The results are shown in Fig.1 and Fig. 2. The first figure shows the dispersion prior the correction, and the second figure after the correction.

43 PARTICLE ACCELERATORS↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗