Search NASA⌕ Search

SEARCH · Search NASA

Results for “CENTRAL RECEIVERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Method for Projecting Cloud Shadows Onto a Central Receiver Field to Predict Receiver Damage

This work demonstrates methods of mapping high-spatial-resolution direct normal irradiance (DNI) data from satellites, Total Sky Imagers (TSIs), and analogous data sources onto a heliostat field for characterizing the spatial and temporal variation of the incident flux on a central receiver tower during cloud transient events. The mapping methods are incorporated into an optical software module that interfaces with CoPylot–SolarPILOT’s python API– to provide computationally efficient optical simulation of the heliostat field and the solar power tower. Eventually, this optical model will be incorporated into optimization models whereby a plant operator can understand the effects of cloud transient events on overall power production and receiver lifetime due to creep-fatigue damage and therefore make better informed decisions about receiver shutdown events. By more accurately modelling the effects of cloud events on receiver flux maps, this work may determine the magnitude and frequency of thermal cycling on receiver tubes and panels using actual or realistic cloud shapes instead of averaged DNI values–which may undercount the total cycle number. This work may also prevent unnecessary plant shutdowns due to overly precautionary control strategies and characterize the relative impact of various cloud types on receiver life. We plan to eventually integrate this methodology into the System Advisor Model (SAM) to improve performance model accuracy during periods of cloudiness. In this paper, we demonstrate generating DNI maps and mapping them to a solar field in CoPylot using 10 m resolution data from publicly available Sentinel-2 satellite data over the Crescent Dunes plant.

Mullin, Matthew↗

Pathways to IEC Standards for Heliostat Design Qualification and Site Acceptance in Central Receiver CSP Applications

This paper surveys the existing landscape of standards relevant to heliostats, identifies their gaps, and proposes a path forward to a comprehensive set of heliostat guidelines, technical specifications, and standards under the framework of International Electrotechnical Commission (IEC) TC 117. Gaps in existing guidelines and standards are surveyed using a three-tiered taxonomy: component-level, heliostat-level, and field-level. At each level, the gap analysis is followed by a proposal for a coordinated path forward on the development of standards. At the component level, advances in the understanding of wind loading should inform a technical specification for drives and structures. Reflectors require consolidation of measurement guidelines into existing standards documents. Communications & controls require technical standards to inform their selection and secure implementation. At the heliostat level, IEC 62817 (solar trackers) adequately characterizes drive systems, structures, and electronics, but requires adaptation to heliostats' use patterns, operating modes, and expected life cycles. IEC 62817 does not address heliostat beam quality and pointing accuracy, but the process for determining both is elaborated in the SolarPACES Guideline for Heliostat Performance Testing. This SolarPACES document requires two main modifications: adaptation to IEC language and inclusion of testing after heliostats which have undergone accelerated weathering and mechanical cycling (to understand performance degradation). At the field level, IEC 62862-4-2 addresses the function and control of heliostat fields but does not cover the statistically rigorous testing of heliostat groups, or field performance factors like security and soiling. The addition of documents under IEC-62862-4 is proposed to address this gap.

beam↗

Impact of Aerosols on Atmospheric Attenuation Loss in Central Receiver Systems: Preprint

Atmospheric attenuation loss between the heliostat field and receiver has been recognized as a significant source of loss in Central Receiver Systems. In clear sky situations, extinction of Direct Normal Irradiance (DNI) is primarily by aerosols in the atmosphere. When aerosol loading is high close to the surface the attenuation loss between heliostat and receivers is significantly influenced bythe amount of aerosols present on a particular day. This study relates measured DNI to aerosol optical depths close to the surface of the earth. The model developed in the paper uses only measured DNI to estimate the attenuation between heliostat and receiver in a central receiver system. The requirement that only a DNI measurement is available potentially makes the model a candidate forwidespread use.

14 SOLAR ENERGY↗

Review and Future Perspective of Central Receiver Design and Performance

Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.

14 SOLAR ENERGY↗

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY↗

A 200kW central receiver CPV system

Raygen Resources has recently completed a Central Receiver CPV (CSPV) pilot plant in Central Victoria, Australia. The system is under final commissioning and initial operation is expected in late April 2015. The pilot demonstrates a full scale CSPV repeatable unit in a form that is representative of a commercial product and provides a test bed to prove out performance and reliability of the CSPV technology. Extensive testing of the system key components: dense array module, wireless solar powered heliostat and control system has been performed in the laboratory and on sun. Results from this key component testing are presented herein.

14 SOLAR ENERGY↗

Correlation between central receiver size and solar field using flat heliostats

In Central Receiver Systems (CRSs), thousands of heliostats track the sunrays and reflect beam radiation on to a receiver surface. The size of the reflected image and the extent of reflection from the heliostats are one of the important criteria that need to be taken into account while designing a receiver, since spillage losses may vary from 2 to 16% of the total losses. The present study aims to determine the size of an external cylindrical receiver, such that the rays reflected from all the heliostats in the field are intercepted. A dimensionless correlation with respect to tower height and receiver size (diameter and height) as a function of heliostat size and its position is discussed in the paper. This correlation could be used as a first-order approximation to estimate the receiver dimensions. When applied to the Ivanpah Solar Electricity Generating Station (ISEGS) plant, the correlation yields satisfactory estimation of receiver dimensions.

14 SOLAR ENERGY↗

Advanced Thermal Storage for Central Receivers with Supercritical Coolants

The principal objective of the study is to determine if supercritical heat transport fluids in a central receiver power plant, in combination with ceramic thermocline storage systems, offer a reduction in levelized energy cost over a baseline nitrate salt concept. The baseline concept uses a nitrate salt receiver, two-tank (hot and cold) nitrate salt thermal storage, and a subcritical Rankine cycle. A total of 6 plant designs were analyzed, as follows: Plant Designation Receiver Fluid Thermal Storage Rankine Cycle Subcritical nitrate salt Nitrate salt Two tank nitrate salt Subcritical Supercritical nitrate salt Nitrate salt Two tank nitrate salt Supercritical Low temperature H2O Supercritical H2O Two tank nitrate salt Supercritical High temperature H2O Supercritical H2O Packed bed thermocline Supercritical Low temperature CO2 Supercritical CO2 Two tank nitrate salt Supercritical High temperature CO2 Supercritical CO2 Packed bed thermocline Supercritical Several conclusions have been drawn from the results of the study, as follows: 1) The use of supercritical H2O as the heat transport fluid in a packed bed thermocline is likely not a practical approach. The specific heat of the fluid is a strong function of the temperatures at values near 400 °C, and the temperature profile in the bed during a charging cycle is markedly different than the profile during a discharging cycle. 2) The use of supercritical CO2 as the heat transport fluid in a packed bed thermocline is judged to be technically feasible. Nonetheless, the high operating pressures for the supercritical fluid require the use of pressure vessels to contain the storage inventory. The unit cost of the two-tank nitrate salt system is approximately $24/kWht, while the unit cost of the high pressure thermocline system is nominally 10 times as high. 3) For the supercritical fluids, the outer crown temperatures of the receiver tubes are in the range of 700 to 800 °C. At temperatures of 700 °C and above, intermetallic compounds can precipitate between, and within, the grains of nickel alloys. The precipitation leads to an increase in tensile strength, and a decrease in ductility. Whether the proposed tube materials can provide the required low cycle fatigue life for the supercritical H2O and CO2 receivers is an open question. 4) A ranking of the plants, in descending order of technical and economic feasibility, is as follows: i) Supercritical nitrate salt and baseline nitrate salt: equal ratings ii) Low temperature supercritical H2O iii) Low temperature supercritical CO2 iv) High temperature supercritical CO2 v) High temperature supercritical H2O 5) The two-tank nitrate salt thermal storage systems are strongly preferred over the thermocline systems using supercritical heat transport fluids.

14 SOLAR ENERGY↗

Advances in central receivers for concentrating solar applications

This paper provides a review of current state-of-the-art commercial central receiver systems and emerging technologies intended to increase the outlet temperature to >700 °C. Research on particle-based, gas-based, and liquid-based receiver designs that can achieve these higher temperatures are discussed. Particle-based technologies include directly irradiated designs (free-falling, obstructed, centrifugal) and enclosed designs (gravity fed, fluidized). New gas-based receivers include micro-channel designs and light-trapping configurations that increase the surface area, heat transfer, and solar absorptance to enable higher fluxes and pressures. Liquid-based receivers and materials that are reviewed include high-temperature halide salts (chlorides and fluorides), carbonate salts, and liquid metals (sodium and lead bismuth). Advantages and challenges associated with each of the technologies and receiver designs are presented.

14 SOLAR ENERGY↗

Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing (Final Report)

The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design.

14 SOLAR ENERGY↗

Evaluation of Annual Efficiencies of High Temperature Central Receiver Concentrated Solar Power Plants With Thermal Energy Storage

The current study has examined four cases of a central receiver concentrated solar power plant with thermal energy storage using the DELSOL and SOLERGY computer codes. The current state-of-the-art base case was compared with a theoretical high temperature case which was based on the scaling of some input parameters and the estimation of other parameters based on performance targets from the Department of Energy SunShot Initiative. This comparison was done for both current and high temperature cases in two configurations: a surround field with an external cylindrical receiver and a north field with a single cavity receiver. There is a fairly dramatic difference between the design point and annual average performance, especially in the solar field and receiver subsystems, and also in energy losses due to the thermal energy storage being full to capacity. Additionally, there are relatively small differences (<2%) in annual average efficiencies between the Base and High Temperature cases, despite an increase in thermal to electric conversion efficiency of over 8%. This is due the increased thermal losses at higher temperature and operational losses due to subsystem start-up and shut-down. Thermal energy storage can mitigate some of these losses by utilizing larger thermal energy storage to ensure that the electric power production system does not need to stop and re-start as often, but solar energy is inherently transient. Economic and cost considerations were not considered here, but will have a significant impact on solar thermal electric power production strategy and sizing.

Ehrhart, Brian David↗

Baseload Nitrate Salt Central Receiver Power Plant Design (Final Report)

The objectives of the work were to demonstrate that a 100 MWe central receiver plant, using nitrate salt as the receiver coolant, thermal storage medium, and heat transport fluid in the steam generator, can 1) operate, at full load, for 6,400 hours each year using only solar energy, and 2) satisfy the DOE levelized energy cost goal of $0.09/kWhe (real 2009 $). To achieve these objectives the work incorporated a large range of tasks relating to many different aspects of a molten salt tower plant. The first Phase of the project focused on developing a baseline design for a Molten Salt Tower and validating areas for improvement. Tasks included a market study, receiver design, heat exchanger design, preliminary heliostat design, solar field optimization, baseline system design including PFDs and P&IDs and detailed cost estimate. The baseline plant met the initial goal of less than $0.14/kWhe, and reinforced the need to reduce costs in several key areas to reach the overall $0.09/kWhe goal. The major improvements identified from Phase I were: 1) higher temperature salt to improve cycle efficiency and reduce storage requirements, 2) an improved receiver coating to increase the efficiency of the receiver, 3) a large receiver design to maximize storage and meet the baseload hours objective, and 4) lower cost heliostat field. The second Phase of the project looked at advancing the baseline tower with the identified improvements and included key prototypes. To validate increasing the standard solar salt temperature to 600 °C a dynamic test was conducted at Sandia. The results ultimately proved the hypothesis incorrect and showed high oxide production and corrosion rates. The results lead to further testing of systems to mitigate the oxide production to be able to increase the salt temperature for a commercial plant. Foster Wheeler worked on the receiver design in both Phase I and Phase II looking at both design and lowering costs utilizing commercial fossil boiler manufacturing. The cost and design goals for the project were met with this task, but the most interesting results had to do with defining the failure modes and looking at a “shakedown analysis” of the combined creep-fatigue failure. A separate task also looked at improving the absorber coatings on the receiver tubes that would improve the efficiency of the receiver. Significant progress was made on developing a novel paint with a high absorptivity that was on par with the current Pyromark, but shows additional potential to be optimized further. Although the coating did not meet the emissivity goals, preliminary testing the new paint shows potential to be much more durable, and potential to improve the receiver efficiency through a higher average absorptivity over the lifetime. Additional coatings were also designed and modeled results meet the project goals, but were not tested. Testing for low cycle fatigue of the full length receiver tubes was designed and constructed, but is still currently undergoing testing. A novel small heliostat was developed through an extensive brainstorming and down select. The concept was then detailed further with inputs from component testing and eventually a full prototype was built and tested. This task met or exceeded the accuracy and structure goals and also beat the cost goal. This provides a significant solar field costs savings for Abengoa that will be developed further to be used in future commercial plants. Ultimately the $0.09/kWhe (real 2009 $) and 6,400 hours goals of the project were met.

14 SOLAR ENERGY↗

Central Receiver Optimization

Sandia National Laboratories (Sandia) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) collaborated to optimize central receivers in the temperature range of 600-900°C suitable for advanced power cycles. It was recognized that significant cost reductions can be made in concentrating solar power (CSP) if efficiency was substantially improved. Advanced cycles such as supercritical CO 2 (sCO 2 ) power cycles offer the potential for high efficiency, but the solar collector and receiver geometry must be considered together to ensure the required inlet conditions for the turbine can be met in a cost-effective manner. This project investigated heliostat life cycle costs, heliostat field layout and associated receiver geometry to better understand the optical and thermodynamic relationship between these components in this temperature range of interest, allowing subsequent optimization. This work will assist the mission of Sandia, the Department of Energy (DOE), and CSIRO to develop sustainable, cost-competitive energy technologies for public use. The purpose of this work was to investigate factors affecting performance and costs of heliostats, including in-field heliostat testing. Alternative receiver designs designed to achieve high temperatures (900 °C and above) were also explored in conjunction with the heliostat field.

Ho, Clifford K.↗

Performance Assessment of Pakistani Central Receiver Plant Case Study Using Aimpoint Strategy Optimization Tools

Pakistan has a high potential for both photovoltaic and Concentrated Solar Power (CSP) deployment to meet its energy requirements. Previous feasibility studies have shown that a variety of CSP technologies are both technically and economically viable in the Pakistani climate and can significantly mitigate the country's current lack of grid reliability. This work aims to enhance the performance of a previously designed Central Receiver System (CRS) plant for Pakistan using state-of-the-art aimpoint optimization methods. Results from our case study show that optimized aiming strategies have increased practicality due to their adherence to flux limitations on the receiver, and offer ~2.4% more thermal energy delivered to the receiver for the Pakistani case study compared to modern performance characterization software, translating to up to 149 additional hours of nameplate-capacity production to address the shortfall in an electricity-starved market.

central receiver system↗

Improved high temperature solar absorbers for use in Concentrating Solar Power central receiver applications.

Concentrating solar power (CSP) systems use solar absorbers to convert the heat from sunlight to electric power. Increased operating temperatures are necessary to lower the cost of solar-generated electricity by improving efficiencies and reducing thermal energy storage costs. Durable new materials are needed to cope with operating temperatures >600 C. The current coating technology (Pyromark High Temperature paint) has a solar absorptance in excess of 0.95 but a thermal emittance greater than 0.8, which results in large thermal losses at high temperatures. In addition, because solar receivers operate in air, these coatings have long term stability issues that add to the operating costs of CSP facilities. Ideal absorbers must have high solar absorptance (>0.95) and low thermal emittance (<0.05) in the IR region, be stable in air, and be low-cost and readily manufacturable. We propose to utilize solution-based synthesis techniques to prepare intrinsic absorbers for use in central receiver applications.

14 SOLAR ENERGY↗

ERDA's central receiver solar thermal power system studies

The utilization of solar energy for electrical power production was studied. Efforts underway on the central receiver solar thermal power system are presented. Preliminary designs are included of pilot plant utilizing large numbers of heliostats in a collector field. Safety hazards are also discussed, as well as the most beneficial location of such a plant within the United States.

Lippy, L. J.↗