Search NASA⌕ Search

SEARCH · Search NASA

Results for “CERIUM 140”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

140,142 Cerium Resolved Resonance Region Evaluation [Slides]

The presentation covers an overview of 140,142 Ce Isotopes, including new evaluations of 140,142 Ce that were requested by the Hanford Plutonium Finishing plant to the Nuclear Criticality Safety Program. It also discusses current ENDF/B-VIII.0 evaluation, which has an error in the 1-2 keV range. It was evaluated using multi-level Breit-Wigner and 142Ce has room for extending resolved resonance region current upper limit from 13 keV. The presentation also discusses new transmission and capture measurements of nat Ce and 142 Ce from Klaus Guber. It also states that no known integral experiments prominently feature Cerium.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Data Sheets for A=140☆

The 2006 evaluation of A=140 was updated using experimental results published before November 2018 from the various reaction and decay studies leading to the nuclei {sup 140}Sb, {sup 140}Te, {sup 140}I, {sup 140}Xe, {sup 140}Cs, {sup 140}Ba, {sup 140}La, {sup 140}Ce, {sup 140}Pr, {sup 140}Nd, {sup 140}Pm, {sup 140}Sm, {sup 140}Eu, {sup 140}Gd, {sup 140}Tb, {sup 140}Dy, {sup 140}Ho. These data are summarized and presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R-matrix Resolved Resonance Region Evaluation of 140,142 Ce

Oak Ridge National Laboratory completed the resolved resonance region (RRR) evaluation of the two most abundant cerium isotopes, 140 Ce (88.45%) and 142 Ce (11.11%), as requested by the US Nuclear Criticality Safety Program. These evaluations are based on recent high-resolution transmission and capture measurements performed on nat Ce and highly enriched 142 Ce samples at the JRC-Geel Linear Accelerator facility, as well as measured thermal constants available from the EXFOR database. Starting from the resonance parameters of the ENDF/B-VIII.0 library followed by a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information were derived by fitting these measured data using the Reich–Moore approximation of the R -matrix theory, as implemented in the SAMMY code system. The 140 Ce RRR upper energy limit was kept at 200 keV, whereas the 142 Ce resonance region was extended from 13 to 26 keV. Updated statistical properties were obtained for the new evaluations and compared to those derived from the ENDF/B-VIII.0 nuclear data library. The new evaluation work improved some of the discrepancies found in previous work, such as the capture resonance integral and stellar Maxwellian-averaged cross sections. These integral quantities were mainly derived from the fit of the latest measured data, especially the neutron capture yield data for 142 Ce isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PROGRESS ON 140,142CE NEUTRON CROSS SECTION RESOLVED RESONANCE REGION EVALUATIONS

Oak Ridge National Laboratory is working on completing the resonance parameter evaluation of 140,142Ce in the neutron energy range up to 200 keV. Performed with the support of the US Nuclear Criticality Safety Program, this evaluation aims to generate high-fidelity cerium cross-section and covariance data. A point-wise representation of the cross sections derived from the resonance parameters will provide improved calculations of self-shielding factors for nuclear criticality safety applications and additional evaluation support for continuous-energy radiation transport methodologies. The evaluation procedure uses the Reich Moore approximation of the R-matrix theory implemented in the SAMMY code system to fit resonance parameters to high-resolution transmission and neutron capture measurements of natCe performed in 2016 by the JRC-GEEL instrument scientists at the Geel Linear Accelerator facility as well as other experimental data sets on both natural and highly-enriched cerium samples available in the experimental library EXFOR. In the analyzed energy range this work aims to improve and extend the resolved resonance region present in the latest US nuclear data library ENDF/B-VIII.0 for 140,142Ce isotopes. This paper will present the preliminary results of the R-matrix analysis based on recently measured natCe transmission data.

Chapman, Chris↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Cerium Stable Isotope Analysis of Synthetic and Terrestrial Rock Reference Materials by MC-ICPMS

Cerium is the most abundant rare earth element (REE) in the solar photosphere, CI chondrites, and the Earth. It has four main stable isotopes (masses: 136,138,140, and 142), with 138Ce being the most studied species, used in geochronology and petrogenesis. In addition, more abundant 140Ce and 142Ce are suggested to be potentially applicable in geochemical investigations. In this work, we developed a modified four-step ion chromatography procedure for Ce chemical separation. Using a MC-ICPMS, we designed a cup configuration to measure 142Ce/140Ce ratio of the samples with an optimized Nd correction equation. A 0.03‰ (2SD) reproducibility was obtained for Ce Ames metal standard. We analyzed ten different igneous and one sedimentary geochemical reference materials. Mean δ142Ce range from −0.07 to 0.32‰. Most of the samples show a heavier Ce isotopic composition than the Ce Ames standard. The majority of rocks have a homogenous δ142Ce. The δ142Ce does not show any correlation with rock chemical composition including their Ce content or rock types. A carbonatite (SARM 40) has a mean δ142Ce of −0.07 ± 0.13‰ (2SD), lower than the other rocks, suggesting the possibility of a pronounced isotopic fractionation. Our work demonstrates the applicability of the developed methodology and the potential of Ce stable isotopes for future geochemical studies. Production of a larger database of δ142Ce values is required to obtain a clearer view on the similarities and differences between different geological material and explaining Ce stable isotope dynamics.

Cerium↗

Radiation-Induced Effects in Ce{sup 3+}- and Eu{sup 2+}-Doped Al{sub 5}O{sub 6}N

Polycrystalline Al{sub 5}O{sub 6}N samples have been prepared by sol–gel synthesis followed by carbothermal reduction and nitridation. X-ray luminescence (XRL) spectra and thermoluminescence (TL) curves of Ce{sup 3+}- and Eu{sup 2+}-doped aluminum oxynitride have been measured in the temperature range 5–380 K and analyzed. Working TL peaks have been detected in the range 150–250 K for the Al{sub 5}O{sub 6}N:Ce{sup 3+} sample and in the range 140–200 K for the Al{sub 5}O{sub 6}N:Eu{sup 2+} samples. There are also lower temperature peaks: in the ranges 10–60 and 20–100 K. The XRL spectra of the samples have been measured at temperatures of 8 (for the first time) and 300 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Study of (n, 2n) Reaction Cross Sections for Ce and Nd Isotopes up to 20 MeV

Neutron cross section calculations for {sup 136}Ce(n, 2n){sup 135}Ce, {sup 138}Ce(n, 2n){sup 137}Ce, {sup 140}Ce(n, 2n){sup 139}Ce, {sup 142}Ce(n, 2n){sup 141}Ce, {sup 142}Nd(n, 2n){sup 141}Nd, {sup 144}Nd(n, 2n){sup 143}Nd, {sup 146}Nd(n, 2n){sup 145}Nd, {sup 148}Nd(n, 2n){sup 147}Nd, and {sup 150}Nd(n, 2n){sup 149}Nd were done in the incident energy range from 10 to 20 MeV. The calculations were performed using three codes TALYS-1.6 for two-component Exciton model, EMPIRE-3.2 Malta for Exciton model, and ALICE/ASH for the Geometry-Dependent Hybrid (GDH) model. The results of model calculations were compared with the available experimental data and also with the evaluated data in the TENDL-2015 (based on the modified TALYS code), ENDF/B-VII.1 libraries. The calculated cross section data were compared with the available experimental data obtained from EXFOR and also compared with semiempirical formulas around 14–15 MeV. The results of model calculation were found to be in good agreement with the experimental data given in literature and semiempirical data around 14–15MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗