Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHARS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Variation of char structure during anthracite pyrolysis catalyzed by Fe{sub 2}O{sub 3} and its influence on char combustion reactivity

Effects of Fe{sub 2}O{sub 3} on the pyrolysis reactivity of demineralized anthracite were investigated by a thermo-gravimetric analyzer, indicating that pyrolysis reactivity of Fe{sub 2}O{sub 3}-loaded demineralized anthracite was higher than that of raw demineralized anthracite when temperature is over 500{sup o}C. Chars were prepared from the two coal samples in muffle with heating progress, and their structures were analyzed using SEM, FTIR, XRD, and Raman. FTIR results showed that absorption peaks of functional groups on the surface of char from catalytic pyrolysis at 700{sup o}C were more than that of char from noncatalytic pyrolysis. Raman results demonstrated values of (I{sub D3} + I{sub D4})/IG of chars from catalytic pyrolysis and noncatalytic pyrolysis were 4.76 and 3.86, respectively, indicating that ordering of the char was decreased by Fe{sub 2}O{sub 3}. XRD analysis revealed that diffraction angle of the 002 peak did not shift; however, L{sub a} and L{sub c} decreased, indicating degree of graphitization for microcrystalline structure of char from catalytic pyrolysis was decreased. The results of FTIR, XRD, and Raman of the char showed that catalytic pyrolysis improved the formation of free radicals, while hindered polymerization and forming of basic structure units. Finally, combustion reactivity of the three chars, including char of raw demineralized anthracite (char-A), char of Fe{sub 2}O{sub 3}-loaded demineralized anthracite (char-B), and char of Fe{sub 2}O{sub 3}-loaded demineralized anthracite washed by HCl (char-C), was investigated using TG and indicated that their active order was char-B > char-C > char-A. The results corroborated that Fe{sub 2}O{sub 3} changed structure of anthracite char and improved combustion reactivity.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of char combustion models: measurement and analysis of variability in char particle size and density

Char samples representing a range of combustion conditions and extents of burnout were obtained from a well-characterized laminar flow combustion experiment. Individual particles from the parent coal and char samples were characterized to determine distributions in particle volume, mass, and density at different extent of burnout. The data were then compared with predictions from a comprehensive char combustion model referred to as the char burnout kinetics model (CBK). The data clearly reflect the particle- to-particle heterogeneity of the parent coal and show a significant broadening in the size and density distributions of the chars resulting from both devolatilization and combustion. Data for chars prepared in a lower oxygen content environment (6% oxygen by vol.) are consistent with zone II type combustion behavior where most of the combustion is occurring near the particle surface. At higher oxygen contents (12% by vol.), the data show indications of more burning occurring in the particle interior. The CBK model does a good job of predicting the general nature of the development of size and density distributions during burning but the input distribution of particle size and density is critical to obtaining good predictions. A significant reduction in particle size was observed to occur as a result of devolatilization. For comprehensive combustion models to provide accurate predictions, this size reduction phenomenon needs to be included in devolatilization models so that representative char distributions are carried through the calculations.

01 COAL, LIGNITE, AND PEAT↗

Quantifying the effect of CO 2 gasification on pulverized coal char oxy-fuel combustion

Previous research has provided strong evidence that CO 2 and H 2 O gasification reactions can provide non-negligible contributions to the consumption rates of pulverized coal (pc) char during combustion, particularly in oxy-fuel environments. Fully quantifying the contribution of these gasification reactions has proven to be difficult, due to the dearth of knowledge of gasification rates at the elevated particle temperatures associated with typical pc char combustion processes, as well as the complex interaction of oxidation and gasification reactions. Gasification reactions tend to become more important at higher char particle temperatures (because of their high activation energy) and they tend to reduce pc oxidation due to their endothermicity (i.e. cooling effect). The work reported here attempts to quantify the influence of the gasification reaction of CO 2 in a rigorous manner by combining experimental measurements of the particle temperatures and consumption rates of size-classified pc char particles in tailored oxy-fuel environments with simulations from a detailed reacting porous particle model. The results demonstrate that a specific gasification reaction rate relative to the oxidation rate (within an accuracy of approximately +/- 20% of the pre-exponential value), is consistent with the experimentally measured char particle temperatures and burnout rates in oxy-fuel combustion environments. Conversely, the results also show, in agreement with past calculations, that it is extremely difficult to construct a set of kinetics that does not substantially overpredict particle temperature increase in strongly oxygen-enriched N2 environments. This latter result is believed to result from deficiencies in standard oxidation mechanisms that fail to account for falloff in char oxidation rates at high temperatures.

42 ENGINEERING↗

A computational fluid dynamics model to estimate local quantities in firebrand char oxidation

Firebrand burning is a complex phenomenon that is influenced by several parameters which are difficult to fully explore experimentally. Computational fluid dynamics models capable of predicting local quantities are essential for accurate prediction of char oxidation in firebrands. This article presents a computational fluid dynamics model to estimate firebrand mass loss, diameter change, and surface temperature during char oxidation. The model was validated using previously conducted wind tunnel experiments. These experiments were conducted for firebrands of two different aspect ratios, which were arranged in three different configurations (single, horizontal array, and vertical array), and for four different wind speeds (0.5, 1, 1.5, and 2 m/s). The computational fluid dynamics results were compared with a previous 1 D model. In all the test cases, the computational fluid dynamics model predicted the physical phenomena with significantly improved accuracy compared to a 1 D model. The char oxidation model presented in this article can be coupled with other models to study firebrand generation and trajectory, biomass pyrolysis, fluidized bed reactors, and coal combustion.

Engineering↗

Molecular Analysis of Primary Vapor and Char Products during Stepwise Pyrolysis of Poplar Biomass

Pyrolysis of biomass produces both pyrolysis oil and solid char. In this study, poplar has been pyrolyzed in a stepwise fashion over a series of temperatures from 200 to 500 C, and both the primary products contributing to pyrolysis oil and the changes in the pyrolyzing poplar surface leading toward char have been characterized at each step. The primary products were identified by direct analysis in real time (DART) mass spectrometry, and the changes in the poplar surface were monitored using Fourier transform infrared (FTIR) photoacoustic spectroscopy, with a sampling depth of a few micrometers. The primary products from pyrolyzing cellulose, xylan, and lignin under similar conditions were also characterized to identify the sources of the poplar products.

09 BIOMASS FUELS↗

Overview of the CHarring Ablator Response (CHAR) Code

An overview of the capabilities of the CHarring Ablator Response (CHAR) code is presented. CHAR is a one-, two-, and three-dimensional unstructured continuous Galerkin finite-element heat conduction and ablation solver with both direct and inverse modes. Additionally, CHAR includes a coupled linear thermoelastic solver for determination of internal stresses induced from the temperature field and surface loading. Background on the development process, governing equations, material models, discretization techniques, and numerical methods is provided. Special focus is put on the available boundary conditions including thermochemical ablation, surface-to-surface radiation exchange, and flowfield coupling. Finally, a discussion of ongoing development efforts is presented.

Amar, Adam J.↗

Overview of the CHarring Ablator Response (CHAR) Code

An overview of the capabilities of the CHarring Ablator Response (CHAR) code is presented. CHAR is a one-, two-, and three-dimensional unstructured continuous Galerkin finite-element heat conduction and ablation solver with both direct and inverse modes. Additionally, CHAR includes a coupled linear thermoelastic solver for determination of internal stresses induced from the temperature field and surface loading. Background on the development process, governing equations, material models, discretization techniques, and numerical methods is provided. Special focus is put on the available boundary conditions including thermochemical ablation and contact interfaces, and example simulations are included. Finally, a discussion of ongoing development efforts is presented.

Amar, Adam J.↗

Development, Verification and Validation of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

With the recent development of multi-dimensional thermal protection system (TPS) material response codes including the capabilities to account for radiative heating is a requirement. This paper presents the recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute view factors for radiation problems involving multiple surfaces. Furthermore, verification and validation of the code's radiation capabilities are demonstrated by comparing solutions to analytical results, to other codes, and to radiant test data.

Salazar, Giovanni↗

Development and Verification of Enclosure Radiation Capabilities in the CHarring Ablator Response (CHAR) Code

With the recent development of multi-dimensional thermal protection system (TPS) material response codes, the capability to account for surface-to-surface radiation exchange in complex geometries is critical. This paper presents recent efforts to implement such capabilities in the CHarring Ablator Response (CHAR) code developed at NASA's Johnson Space Center. This work also describes the different numerical methods implemented in the code to compute geometric view factors for radiation problems involving multiple surfaces. Verification of the code's radiation capabilities and results of a code-to-code comparison are presented. Finally, a demonstration case of a two-dimensional ablating cavity with enclosure radiation accounting for a changing geometry is shown.

Salazar, Giovanni↗