90Y Cherenkov Radiation Counting
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Measurement of Cherenkov radiation (CR) has long been a useful technique for charged particle detection and beam diagnostics. We are investigating metamaterials engineered to have refractive indices tailored to enhance properties of CR that are useful for particle detectors and that cannot be obtained using conventional media. Cherenkov radiation in dispersive media with a large refractive index differs significantly from the same effect in conventional detector media, like gases or aerogel. The radiation pattern of CR in dispersive metamaterials presents lobes at very large angles with respect to particle motion. Moreover, the frequency and particle velocity dependence of the radiated energy can differ significantly from CR in a conventional dielectric medium.
The mechanism of generation of Vavilov-Cherenkov radiation is discussed in this article. The developers of the theory of the Vavilov-Cherenkov effect, I.E. Tamm and I.M. Frank, attributed this effect to their discovery of a new mechanism of radiation when a charged particle moves uniformly and rectilinearly in the medium. As such a mechanism presupposes the violation of the laws of conservation of energy and momentum, they proposed the abolition of these laws to account for the Vavilov-Cherenkov radiation mechanism. This idea has received a considerably wide acceptance in the creation of other theories, for example, transition radiation theory. In this paper, the radiation mechanism for the charge constant motion is demonstrated to be incorrect, because it contradicts not only the laws of conservation of energy and momentum, but also the very definitions of uniform and rectilinear motion (Newton's First Law). A consistent explanation of the Vavilov-Cherenkov radiation microscopic mechanism that does not contradict the basic laws is proposed. It is shown that the radiation arises from the interaction of the moving charge with bound charges that are spaced fairly far away from its trajectory. The Vavilov-Cherenkov radiation mechanism bears a slowing down character, but it differs fundamentally from bremsstrahlung, primarily because the Vavilov-Cherenkov radiation onset results from a two-stage process. First, the moving particle polarizes the medium; then, the already polarized atoms radiate coherently, provided that the particle velocity exceeds the phase speed of light in the medium. If the particle velocity is less than the phase speed of light in the medium, the polarized atoms return energy to the outgoing particle. In this case, radiation is not observed. Special attention is given to the relatively constant particle velocity as the condition of the coherent composition of waves. However, its motion cannot be designated as a uniform and rectilinear one in the sense of its definition by Newton's First Law, and it also contradicts the laws of conservation of energy and momentum.
The use of coherent Cherenkov radiation as a diagnostic tool for longitudinal distribution of an electron beam is studied in this paper. Coherent Cherenkov radiation is produced in an aerogel with an index of refraction close to unity. An aerogel spectral properties are experimentally studied and analyzed. This method will be employed for the helical IFEL bunching experiment at Neptune linear accelerator facility at UCLA.
Visible Cherenkov radiation can offer a method of the measurement of the velocity of charged particles. The angular width of the radiation is important since it determines the resolution of the velocity measurement. In this article, the angular width of Cherenkov radiation with inclusion of multiple scattering is calculated through the path-integral method, and the analytical expressions are presented. The condition that multiple scattering processes dominate the angular distribution is obtained.
We consider the Cherenkov radiation of a neutral particle with magnetic moment, and the spin-dependent contribution to the Cherenkov radiation of a charged spinning particle. The corresponding radiation intensity is obtained for an arbitrary value of spin and for an arbitrary spin orientation with respect to velocity.
A canonical approach to Cherenkov radiation in the presence of a magnetodielectric medium is presented in classical, nonrelativistic, and relativistic quantum regimes. The equations of motion for the canonical variables are solved explicitly for both positive and negative times. Maxwell and related constitute equations are obtained. In the large-time limit, the vector potential operator is found and expressed in terms of the medium operators. The energy loss of a charged particle, emitted in the form of radiation, in finite temperature is calculated. A Dirac equation concerning the relativistic motion of the particle in presence of the magnetodielectric medium is derived and the relativistic Cherenkov radiation at zero and finite temperature is investigated. Finally, it is shown that the Cherenkov radiation in nonrelativistic and relativistic quantum regimes, unlike its classical counterpart, introduces automatically a cutoff for higher frequencies beyond which the power of radiation emission is zero.
Numerical methods are used to study the dependence of the structure and the width of the angular distribution of Vavilov-Cherenkov radiation with a fixed wavelength in the vicinity of the Cherenkov cone on the radiator parameters (thickness and refractive index), as well as on the parameters of the relativistic heavy ion beam (charge and initial energy). The deceleration of relativistic heavy ions in the radiator, which decreases the velocity of ions, modifies the condition of structural interference of the waves emitted from various segments of the trajectory; as a result, a complex distribution of Vavilov-Cherenkov radiation appears. The main quantity is the stopping power of a thin layer of the radiator (average loss of the ion energy), which is calculated by the Bethe-Bloch formula and using the SRIM code package. A simple formula is obtained to estimate the angular distribution width of Cherenkov radiation (with a fixed wavelength) from relativistic heavy ions taking into account the deceleration in the radiator. The measurement of this width can provide direct information on the charge of the ion that passes through the radiator, which extends the potentialities of Cherenkov detectors. The isotopic effect (dependence of the angular distribution of Vavilov-Cherenkov radiation on the ion mass) is also considered.
We show through theory and numerics that when few-cycle femtosecond solitons are generated through cascaded (phase-mismatched) second-harmonic generation, these broadband solitons can emit optical Cherenkov radiation in the form of linear dispersive waves located in the red part of the spectrum. The beating between the dispersive wave and the soliton generates trailing temporal oscillations on the compressed soliton. Insertion of a simple short-wave pass filter after the crystal can restore a clean soliton. On the other hand, bandpass filtering around the dispersive wave peak results in near-transform-limited ultrashort mid-IR pulses with pulse durations much shorter than the input near-IR pulse. The Cherenkov radiation for the crystal considered ({beta}-barium borate) is found for pump wavelengths in the range {lambda}=0.95-1.45 {mu}m, and is located in the regime {lambda}=1.5-3.5 {mu}m. For shorter pump wavelengths, the phase-matching point is located in the absorption region of the crystal, effectively absorbing the generated dispersive wave. By calculating the phase-matching curves for typically used frequency conversion crystals, we point out that the mid-IR absorption in the crystal in many cases automatically will filter away the dispersive wave. Finally, an investigation of recent experimental results uncovers a four-wave-mixing phenomenon related to Cherenkov radiation that is an additional generation mechanism of long-wavelength radiation that can occur during soliton compression. We discuss the conditions that lead to this alternative dynamics rather than generation of Cherenkov radiation.
During megavoltage photon and electron beam radiotherapy treatment involving the eye, patients commonly report visual sensations; 'nerve stimulation' is the conventional explanation. We propose that the phenomenon can be attributed to Cherenkov radiation inside the eye. The threshold electron energy for Cherenkov radiation in water is 260 keV. The human retina is able to perceive approximately 5-14 visible photons in 0.001 s. A single 500 keV electron traversing 1 mm of water will induce nearly 15 Cherenkov visible range photons. We propose that a portal image involving the eye will produce sufficient Cherenkov radiation to be detected by the retina.
Multimode terahertz(THz)-wave generation using coherent Cherenkov radiation (CCR) was investigated. The frequency spectra of CCR, which utilized a metal-wrapped hollow dielectric tube of 7 mm outer radius and a picosecond electron bunch of 27 MeV beam energy, were measured by a Michelson interferometer with a 4.2 K silicon bolometer. In this study, discrete spectral components at frequencies of 0.09, 0.14, and 0.36 THz were observed experimentally and explained as transverse magnetic (TM) modes of TM{sub 03}, TM{sub 04}, and TM{sub 09}, respectively, according to a theoretical calculation for the tube.
Purpose: A novel technique for optical dosimetry of dynamic intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 (TG-119) C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank doped with the fluorophore quinine sulfate. The ICCD acquisition was gated to the Linac target trigger pulse to reduce background light artifacts, read out for a single radiation pulse, and binned to a resolution of 512 × 512 pixels. The resulting videos were analyzed temporally for various regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR), and summed to obtain an overall light intensity distribution, which was compared to the expected dose distribution from the TPS using a gamma-index analysis. Results: The chosen camera settings resulted in 23.5 frames per second dosimetry videos. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.9% and 96.2% agreement between the experimentally captured Cherenkov light distribution and expected TPS dose distribution based upon a 3%/3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans, respectively. Conclusions: The results from this initial study demonstrate the first documented use of Cherenkov radiation for video-rate optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications.
Purpose: A novel optical dosimetry technique for the QA and verification of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) radiotherapy plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: An intensified CCD camera (ICCD) was used to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank. The ICCD acquisition was gated to the Linac, operated for single pulse imaging, and binned to a resolution of 512×512 pixels. The resulting videos were analyzed temporally for regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR) and summed to obtain an overall light distribution, which was compared to the expected dose distribution from the TPS using a gammaindex analysis. Results: The chosen camera settings resulted in data at 23.5 frames per second. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.2% and 95.6% agreement between the light distribution and expected TPS dose distribution based upon a 3% / 3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans respectively. Conclusion: The results from this initial study demonstrate the first documented use of Cherenkov radiation for optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications. NIH R01CA109558 and R21EB017559.
This Letter presents a Cherenkov radiation oscillator with an electron beam travelling over a finitely thick plate made of negative-index materials. In such a scheme, the external reflectors required in the traditional Cherenkov oscillators are not necessary, since the electromagnetic energy flows backward in the negative-index materials, leading to inherent feedback. We theoretically analyzed the interaction between the electron beam and the electromagnetic wave, and worked out the growth rate and start current through numerical calculations. With the help of particle-in-cell simulation, the theoretical predictions are well demonstrated.
The Cherenkov radiation resulting from a fast electron in ultrashort intense laser plasma is explored theoretically based on the density perturbation theory. The radiation emitting conditions and characteristics of the corresponding Cherenkov geometry are discussed in detail. By numerical computation, a significant conclusion is revealed that the THz radiation of Cherenkov-type can be excited by the coupling of a fast electron produced by an intense ultrashort pulse laser and plasma medium in specifically parameter conditions. The results show that the radiation intensity is strongly dependent on the pulse duration of incident laser and the velocity of a fast electron, the emission spectrum width is dependent on the plasma density and the ratio of a fast electron and laser group velocities, and the emission angle distribution is dependent on the effective radius of laser beam.
A nonlinear quantum theory of stimulated Cherenkov radiation of transverse electromagnetic waves from a low-density relativistic electron beam in an isotropic dielectric medium is presented. A quantum model based on the Klein-Gordon equation is used. The growth rates of beam instabilities caused by the effect of stimulated Cherenkov radiation have been determined in the linear approximation. Mechanisms of the nonlinear saturation of relativistic quantum Cherenkov beam instabilities have been analyzed and the corresponding analytical solutions have been obtained.
We demonstrate that the general second-order scalar-tensor theories, which have attracted attention as possible modified gravity models to explain the late time cosmic acceleration, could be strongly constrained from the argument of the gravitational Cherenkov radiation. To this end, we consider the purely kinetic coupled gravity and the extended galileon model on a cosmological background. In these models, the propagation speed of tensor mode could be less than the speed of light, which puts very strong constraints from the gravitational Cherenkov radiation.
Using a picosecond image converter camera with a linear sweep (PS-1/S1 streak camera developed at GPI RAS, Moscow), we have measured temporal parameters of Vavilov – Cherenkov radiation pulses. The radiation was generated by relativistic electrons passing through a quartz cone mounted on the axis of a vacuum chamber of a linear accelerator, which is a part of the VEPP-5 injection complex at the Budker Institute of Nuclear Physics, Siberian Branch of the Russian Academy of Sciences (BINP SB RAS, Novosibirsk). The data obtained in these experiments provide an insight into the processes of formation of electron bunches and their ‘quality’ in a linear accelerator prior to injection of electrons into the accumulator-cooler. A conclusion is made regarding the advisability of streak camera application in tuning the linear accelerators for optimisation of electron bunch parameters. (Vavilov – Cherenkov radiation)