Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATIC ABERRATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Influence of Time-of-Flight Chromatic Aberration on the Dynamics of Propagation of Pulsed Electron Beam in Ultrafast Electron Microscopy: A New Strategy for Better Temporal Resolution

A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some Considerations Regarding Pulsed Correction of Chromatic Aberrations in Final Focusing Systems

Nearly all designs of accelerators for heavy ion fusion rely on a velocity (energy) ramp to compress the beam longitudinally from its length in the accelerator to the length required at the target. The size of the velocity ramp is constrained by the longitudinal emittance of the beam. For example, if the longitudinal emittance is 0.05 eV {center_dot} s and we wish to produce a pulse having a width of {+-}2.5 ns at the target, we must supply an energy tilt such that the energy spread at the target is at least {+-}0.05 eV {center_dot} s/2.5 ns = {+-}2 x 10{sup 7} eV. The minimal value of energy spread occurs when the beam has propagated to the point where there is no correlation between the time and energy variables of the beam particles. (In the simple approximation where the boundary of the longitudinal phase space containing the particles is an ellipse, the ellipse is erect at this point, i.e., not tilted with respect to the axes.) In any case, the energy spread can affect focusing. If, for example, the beam kinetic energy is of the order of 5 GeV, a tilt of {+-}2 x 10{sup 7} eV corresponds to a fractional energy spread of 0.004 and it may be possible to focus the beam to the required spot size without using an achromatic optical system. Nevertheless, an optical system that allows larger longitudinal emittance should lead to a less expensive accelerator since the tolerances on acceleration waveforms could be relaxed. Moreover, at lower kinetic energies the problem becomes more serious. If the kinetic energy of our example beam were 1 GeV rather than 5 GeV, the fractional energy spread would be 0.02. This much energy spread would likely produce serious chromatic aberrations leading to an unwanted increase in focal spot size. It is interesting to note that the lower limit on energy spread at the target does not depend on whether the beam is neutralized as it approaches the target. If the beam is not neutralized, it will require a larger initial velocity tilt to overcome longitudinal space-charge forces; but these forces will remove part of the tilt as the beam compresses. Al Maschke suggested that it is possible to reduce the chromatic aberrations by applying a time-dependent transverse focusing correction to the beam upstream of the final focusing lenses [1]. At this point, because of the energy tilt, there is a correlation between longitudinal position in the beam and particle energy. In other words, the average beam energy at the tail of the beam is larger than the average beam energy at the head of the beam. If the beam is completely neutralized as it drifts toward the final focusing lenses, the kinetic energies of the individual particles will remain nearly unchanged during compression. In this case, it is possible, in principle, to apply some 'pre-focusing' to the higher energy particles (those nearer to the tail of the beam) to compensate for their weaker focusing in the final lenses. Although kinetic energies of individual particles are not conserved if the beam is not neutralized, one still expects a positive correlation between the particle energies at the beginning of compression and at the end of compression so correction is still assumed to be possible. It is important that the pulse duration is larger upstream than it is at the final focusing lenses. Larger pulse duration makes it easier, from an engineering standpoint, to supply the power needed to drive the pulsed correction elements. Nevertheless, it still appears impossible or very costly to provide the needed power for some specific cases that have been studied. In the remainder of this paper we ignore this issue and try to determine if there are other fundamental limitations on how well one might correct. We conclude that there are other important limitations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of chromatic aberrations using phase retrieval

We explore the feasibility of measuring chromatic aberrations using a technique based on phase retrieval, primarily for the purpose of diagnostics on the OMEGA EP laser. A computational model and optimization strategy is described, issues of numerical efficiency are addressed, and the potential limitations of the method are studied using mathematical analysis and Monte Carlo simulations. As a result, the algorithm performs well in simulation and yields encouraging results in a small-scale laboratory experiment.

97 MATHEMATICS AND COMPUTING↗

Fast Correction Optics to Reduce Chromatic Aberrations in Longitudinally Compressed Ion Beams

Longitudinally compressed ion beam pulses are currently employed in ion-beam based warm dense matter studies [1]. Compression arises from an imposed time-dependent longitudinal velocity ramp followed by drift in a neutralized channel. Chromatic aberrations in the final focusing system arising from this chirp increase the attainable beam spot and reduce the effective fluence on target. We report recent work on fast correction optics that remove the time-dependent beam envelope divergence and minimizes the beam spot on target. We present models of the optical element design and predicted ion beam fluence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chromatic-aberration diagnostic based on a spectrally resolved lateral-shearing interferometer

Here, a simple diagnostic characterizing one-dimensional chromatic aberrations in a broadband beam is introduced. A Ronchi grating placed in front of a spectrometer entrance slit provides spectrally coupled spatial phase information. The radial-group delay of a refractive system and the pulse-front delay of a wedged glass plate have been characterized accurately in a demonstration experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chromatic-aberration-corrected diffractive lenses for ultra-broadband focusing

We exploit the inherent dispersion in diffractive optics to demonstrate planar chromatic-aberration-corrected lenses. Specifically, we designed, fabricated and characterized cylindrical diffractive lenses that efficiently focus the entire visible band (450 nm to 700 nm) onto a single line. These devices are essentially pixelated, multi-level microstructures. Experiments confirm an average optical efficiency of 25% for a three-wavelength apochromatic lens whose chromatic focus shift is only 1.3 μm and 25 μm in the lateral and axial directions, respectively. Super-achromatic performance over the continuous visible band is also demonstrated with averaged lateral and axial focus shifts of only 1.65 μm and 73.6 μm, respectively. These lenses are easy to fabricate using single-step grayscale lithography and can be inexpensively replicated. Furthermore, these devices are thin (<3 μm), error tolerant, has low aspect ratio (<1:1) and offer polarization-insensitive focusing, all significant advantages compared to alternatives that rely on metasurfaces. Lastly, our design methodology offers high design flexibility in numerical aperture and focal length, and is readily extended to 2D.

36 MATERIALS SCIENCE↗

HEAVY ION FUSION SCIENCE VIRTUAL NATIONAL LABORATORY 1ST QUARTER 2010 MILESTONE REPORT: Simulations of fast correction of chromatic aberrations to establish physics specifications for implementation on NDCX-1 and NDCX-2

This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory has completed simulations of a fast correction scheme to compensate for chromatic and time-dependent defocusing effects in the transport of ion beams to the target plane in the NDCX-1 facility. Physics specifications for implementation in NDCX-1 and NDCX-2 have been established. Focal spot differences at the target plane between the compressed and uncompressed regions of the beam pulse have been modeled and measured on NDCX-1. Time-dependent focusing and energy sweep from the induction bunching module are seen to increase the compressed pulse spot size at the target plane by factors of two or more, with corresponding scaled reduction in the peak intensity and fluence on target. A time-varying beam envelope correction lens has been suggested to remove the time-varying aberration. An Einzel (axisymmetric electric) lens system has been analyzed and optimized for general transport lines, and as a candidate correction element for NDCX-1. Attainable high-voltage holdoff and temporal variations of the lens driving waveform are seen to effect significant changes on the beam envelope angle over the duration of interest, thus confirming the utility of such an element on NDCX-1. Modeling of the beam dynamics in NDCX-1 was performed using a time-dependent (slice) envelope code and with the 3-D, self-consistent, particle-in-cell code WARP. Proof of concept was established with the slice envelope model such that the spread in beam waist positions relative to the target plane can be minimized with a carefully designed Einzel lens waveform and transport line. WARP simulations have verified the efficacy of the Einzel lens while including more detailed beam physics. WARP simulations have also indicated some unpredicted transittime effects, and methods are currently being explored to compensate and reduce this complication. We have explored the use of an Einzel lens, or system of Einzel lenses, to compensate for chromatic aberrations in the beam focal spot in the NDCX-2 target plane. The final beam manipulations in NDCX-2 (linear velocity ramp, charge neutralization, high field final focus solenoid) are similar to NDCX-1 though the NDCX-2 beam has much higher energy and current. The most relevant distinctions are that the pulse duration at the entrance to the drift compression section is tenfold shorter, and that the beam energy tenfold higher, than in NDCX-1. Placing a time-dependent, envelope angle correcting element at the neutralized drift region entrance presents a very significant challenge to voltage holdoff and voltage swing V(t) in a single Einzel lens. Placing the Einzel lens(es) further upstream reduces the required voltage risetime V'(t) to effect the necessary envelope correction, while increasing the duration over which the timedependent voltage must vary. While this simplifies the technological challenge of designing and operating a Einzel lens in NDCX-2, it does require much finer control of the correcting waveform and measurements of its effect on space-charge dominated beams over a much longer axial path length to target than in the NDCX-1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A general purpose wideband optical spatial frequency spectrum analyzer

The light scattered at various angles by a transparent media is studied. An example of these applications is the optical Fourier spectrum measurement resulting from various spatial frequencies which were recorded on a photographic emulsion. A method for obtaining these measurements consists of illuminating the test object with parallel monochromatic light. A stationary lens, placed in the resulting wavefield at a distance of one focal length from the object, will focus parallel waves emanating from the test object at a point lying in the focal plane of the lens. A light detector with a small filtering aperture is then used to measure the intensity variation of the light in the focal or transform plane of the lens. Such measurements require the use of a lens which is highly corrected for all of the common aberrations except chromatic aberration.

Ballard, G. S.↗

Analysis and design of a refractive virtual image system

The optical performance of a virtual image display system is evaluated. Observation of a two-element (unachromatized doublet) refractive system led to the conclusion that the major source of image degradation was lateral chromatic aberration. This conclusion was verified by computer analysis of the system. The lateral chromatic aberration is given in terms of the resolution of the phosphor dots on a standard shadow mask color cathode ray tube. Single wavelength considerations include: astigmatism, apparent image distance from the observer, binocular disparities and differences of angular magnification of the images presented to each of the observer's eyes. Where practical, these results are related to the performance of the human eye. All these techniques are applied to the previously mentioned doublet and a triplet refractive system. The triplet provides a 50-percent reduction in lateral chromatic aberration which was the design goal. Distortion was also reduced to a minimum over the field of view. The methods used in the design of the triplet are presented along with a method of relating classical aberration curves to image distance and binocular disparity.

Kahlbaum, W. M.↗

Large energy-spread beam diagnostics through quadrupole scans

The Facility for Advanced Accelerator and Experimental Tests (FACET) is a new user facility at the SLAC National Accelerator Laboratory, servicing next-generation accelerator experiments. The 1.5% RMS energy spread of the FACET beam causes large chromatic aberrations in optics. These aberrations necessitate updated quadrupole scan fits to remain accurate.

43 PARTICLE ACCELERATORS↗

A novel electron mirror pulse compressor

An electron mirror-based pulse compressor design has been developed for improving the temporal resolution of dynamic/ultrafast transmission electron microscopes and ultrafast electron diffraction cameras. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. The design utilizes a combination of mirror optics and a magnetic beam separator, which exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the pulse. This system can also simultaneously correct the spherical and chromatic aberration of the objective lens for improved spatial resolution. For pulsed experiments with a practical bunch charge, the correction of the chromatic aberration coefficient counters the spread in the electron energies induced by the space charge of the pulse to make possible the probing of the sample with high spatial resolution. The pulse compressor can accommodate pulses with a range of electron densities and energy spreads. Additionally, it is designed to fit into both ultrafast electron diffraction cameras and dynamic/ultrafast transmission electron microscopes. Consequently, this instrument is suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales.

47 OTHER INSTRUMENTATION↗

Application of Monte Carlo techniques to optimization of high-energy beam transport in a stochastic environment

An algorithm employing a modified sequential random perturbation, or creeping random search, was applied to the problem of optimizing the parameters of a high-energy beam transport system. The stochastic solution of the mathematical model for first-order magnetic-field expansion allows the inclusion of state-variable constraints, and the inclusion of parameter constraints allowed by the method of algorithm application eliminates the possibility of infeasible solutions. The mathematical model and the algorithm were programmed for a real-time simulation facility; thus, two important features are provided to the beam designer: (1) a strong degree of man-machine communication (even to the extent of bypassing the algorithm and applying analog-matching techniques), and (2) extensive graphics for displaying information concerning both algorithm operation and transport-system behavior. Chromatic aberration was also included in the mathematical model and in the optimization process. Results presented show this method as yielding better solutions (in terms of resolutions) to the particular problem than those of a standard analog program as well as demonstrating flexibility, in terms of elements, constraints, and chromatic aberration, allowed by user interaction with both the algorithm and the stochastic model. Example of slit usage and a limited comparison of predicted results and actual results obtained with a 600 MeV cyclotron are given.

Parrish, R. V.↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Presentation Annotated

This Report is not the latest word on an old idea but the first word on a new one. The new idea reverses the old one, the axiom that the best primary objective for an astronomical telescope exhibits the least chromatic aberration. That axiomatic distinction goes back to a young Isaac Newton who knew from experiments with prisms and mirrors in the 1660's that magnification with a reflection primary was completely free of the dispersion he saw with refraction. The superiority of reflection primary objectives for eyeball or photographic viewing is now considered obvious. It was this piece of wisdom on achromatic primary objectives that led to the dominance of the parabolic mirror as the means to collect star light. Newton was aware of the problem when he introduced his telescope to the scientific world in 1670.This Report is not the latest word on an old idea but the first word on a new one. The new idea reverses the old one, the axiom that the best primary objective for an astronomical telescope exhibits the least chromatic aberration. That axiomatic distinction goes back to a young Isaac Newton who knew from experiments with prisms and mirrors in the 1660's that magnification with a reflection primary was completely free of the dispersion he saw with refraction. The superiority of reflection primary objectives for eyeball or photographic viewing is now considered obvious. Actually, Newton's design innovation was in a secondary mirror, a plane mirror far more easily fabricated than Gregory's embodiment of 1663 which required two curved mirrors.

Astronomical telescope↗