Examining the Influence of Silver(I) Ion Coordination Environment in Ionic Liquids on Olefin–Paraffin Separations using Inverse Gas Chromatography
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Not provided.
Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.
Deep eutectic solvents (DESs) represent a class of solvents that offer a number of advantages including minimal toxicity, affordability, low vapor pressure, and simple, environmentally friendly preparation methods. They have found utility in areas, such as gas absorption, metal plating, and extractions. However, the relationship between their solvation properties and chemical composition remains poorly understood. In this study, a broad range of Type I DESs composed of metal chlorides and an imidazolium salt were prepared, employed as gas chromatographic stationary phases, and characterized using the Abraham solvation parameter model by inverse gas chromatography. The Abraham solvation parameter model allows for the study of DES solvation properties and the effects of varying structural components on system constants using a linear-free energy relationship. The DESs were investigated by systematically varying their composition, including the type of metal chloride and the molar ratio between the metal chloride and the imidazolium salt. The results show that hydrogen bond acidity, hydrogen bond basicity, and dipolarity/polarizability interactions are strongly influenced by the type of metal chloride within the DES and the ratio of metal chloride to imidazolium salt in the eutectic mixture. Furthermore, a column pretreatment procedure is presented that enables the effective coating of highly polar DESs onto open tubular capillary gas chromatography columns.
Green chemistry is a set of principles for assessing, developing, and implementing methods that are safer, more efficient, and less detrimental to the environment. The analytical method greenness score (AMGS) is one of many metrics that attempt to evaluate traditional liquid chromatography (LC) based on the energy consumption of the instrument and the safety, health risks, and environmental impact of the solvents employed. Unfortunately, in practice, the AMGS is primarily focused on traditional separation methods in the pharmaceutical industry and is not amenable to cutting-edge separation science, including miniaturization. To broaden this scope, the unified Analytical Method Greenness Score (uAMGS) is presented here, which clarifies and expands on the underlying mathematics and incorporates both dimensional and uncertainty analysis, enabling its application to a broader range of analytical techniques. The uAMGS is used to compare the greenness of two distinct methods: single-molecule microscopy (SMM) and high-performance liquid chromatography (HPLC), which were used to collect equivalent data. uAMGS determines that SMM is significantly greener than HPLC due primarily to decreased solvent consumption. Overall, the uAMGS should allow chemists ranging from undergraduates to industrial PhDs to assess the greenness of a wide range of separations.
Direct Lithium Extraction (DLE) technologies often struggle to produce high-purity lithium salts from high-salinity brines, as current approaches require chemical-based elution, regeneration, and precipitation steps, resulting in significant environmental footprints. A novel salt fractionation approach using carboxybetaine resin, known as zwitterionic chromatography (ZIC), has demonstrated that lithium ions can be separated from divalent cations under high-salinity conditions using only water as eluent, with no regeneration required. To enable continuous and scalable deployment of this approach, we developed a chemical-free Multi-column Zwitterionic Chromatography (MZC) process and its theoretical and process models. To predict and optimize this nontraditional separation system, we introduced a novel anti-Langmuir isotherm, and the isotherm parameters were estimated through a machine learning-driven optimization based on artificial neural network ensembles with numerical feasibility assessment. Using machine learning-driven optimization, the MZC process achieved 98.0% lithium recovery, 99.5 % Li/(Li + Mg + Ca) purity, a 31.3% productivity increase, and a 33% reduction in water use compared to batch operation. The proposed MZC process enables lithium separation at $0.6-1.2 kg-1 Li, with costs dominated by resin manufacturing, while offering lower separation costs and carbon footprint compared with conventional carbonation. Overall, these findings position the MZC process as an effective polishing step within scalable and sustainable lithium production pipelines.
Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.
The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.
Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.
The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.
With the growing interest in using radium-226 (Ra-226) as a source material to produce essential radionuclides for targeted alpha therapies, the global demand for Ra-226 has surged, rendering its acquisition difficult. The shortage necessitates the exploration of alternative pathways to obtain this isotope beyond traditional commercial vendors. Legacy radium sources remain widespread due to Ra-226’s historical use but require the removal of ingrown daughter products to obtain a pure Ra-226 product. In conclusion, a straightforward and effective purification method for legacy Ra-226 ampoules has been developed using cation exchange chromatography, enabling the reliable conversion of legacy materials into high-purity Ra-226 solutions.
Cell surface-associated polysaccharides in Klebsiella are major virulence determinants and crucial targets for developing vaccines. Traditionally, the purification of these cell surface polysaccharides from Klebsiella pneumoniae involves a multi-step process comprising phenol extraction, nuclease digestion, ultracentrifugation, and repeated ethanol extractions. In this study, we evaluated size exclusion chromatography for effectively eliminating nucleic acid contamination while purifying high molecular weight cell surface-associated polysaccharides. Post-initial extraction, the nucleic acid content remains significantly elevated, and kinetic analysis reveals that DNase I and RNase A digestion is neither economically viable nor effective for removing these contaminants. Employing an appropriate size exclusion resin removes over 99 % of nucleic acid contamination, as confirmed by nucleic acid content analysis and agarose gel electrophoresis. Purity and structural analysis using 1H 1D-NMR and 2D-NMR demonstrate that the cell surface-associated polysaccharide purified with this study is highly homogeneous and identified as antigenic O-polysaccharide. This approach streamlines the purification process by removing the need for nuclease digestion and additional ethanol precipitation steps.
Advanced used nuclear fuel (UNF) reprocessing strategies are limited by the complex radiochemical separations and engineering required to achieve the separation of actinides (An) from neutron scavenging lanthanides (Ln). The accessibility of the hexavalent oxidation state for the actinides (U – Am) provides a pathway to achieving a group hexavalent actinide separation from the trivalent lanthanides and Cm. The solid oxidant and ion exchanger, sodium bismuthate (NaBiO 3 ), has been demonstrated to quantitatively oxidize and separate Am from trivalent Cm in a column chromatographic system. This work expands on the use of NaBiO 3 chromatography to characterize the adsorption, kinetic, and elution behavior of U, Pu, and Eu. Separation factors over 200 with rapid kinetics were observed at dilute nitric acid concentrations with a complete An/Ln separation achieved in under an hour. In conclusion, the adsorption and chromatographic behavior of key fission products present in various reprocessing raffinates was characterized which demonstrated potential application of a NaBiO 3 -based separation following a TRUEX process.
Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.
Understanding chemical changes that occur in high explosives as they age is of great importance to the safe employment and storage of these compounds. Traditional methods of aging high explosives even under accelerated aging conditions are time intensive with durations on the order of months to years. The nature of traditional aging analyses reduces each sample to a snapshot data point often separated widely in time, requiring many assumptions as to how the degradation products develop. Further complicating matters, several analytical techniques are typically employed for each sample analysis in order to ascertain an entire picture of the decomposition pathways. To address these shortcomings with existing methods, a new method of accelerated aging of high explosives utilizing comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry (GC × GC-HRMS) was developed using 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) as a model compound for method development. This in situ automated method reduces the time scale of aging to a matter of hours using the inlet of the GC × GC as the aging vessel. GC × GC in combination with HRMS allowed for the collection of both evolved gases and other decomposition products produced during the entire aging process in real time with HRMS providing far greater certainty in identification of explosives aging products. Additionally, this method allowed for a higher throughput of samples with greatly simplified sample preparation. Chemometric analysis of the GC × GC-HRMS data set via the alteration analysis (ALA) enabled discovery of statistically significant chemical changes providing insight into the variation of decomposition pathways with varying aging temperatures.
An extraction protocol from silt sediment of fentanyl and three analogs: acetylfentanyl, thiofentanyl and acetylthiofentanyl, spiked at two concentrations each and separately (at ~1 and ~10 µg/g), is described. In addition, the identity of the fentanyls preliminarily identified by electron ionization gas chromatography-mass spectrometry (EI-GC-MS) analysis, can be corroborated by reacting each opioid in the silt’s extract with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl). Further, reaction between Troc-Cl and each opioid generates two unique products that can be used to retrospectively identify the original opioid therefore serving as a corroborating tool for known opioids as well as new, unknown fentanyl analogs.
Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.
Gel permeation chromatography analysis of the uncrosslinked portions of polymeric encapsulants (EVA, POE, EPE) aged under thermal accelerated aging conditions (in the absence of UV) is not a reliable way to measure encapsulant crosslinking nor degradation