Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMIUM NITRATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The photocatalytic investigation of methylene blue dye with Cr doped zinc oxide nanoparticles

The present work reports eco-friendly and cost effective sol-gel technique for synthesis of Chromium doped ZnO nanoparticles at room temperature. In this process Zinc nitrate, Chromium nitrate were used as precursor. Structural as well as optical properties of Cr induced ZnO samples were analysed by X-ray diffraction technique (XRD), SEM, PL and UV-Visible spectroscopy (UV-Vis) respectively. XRD analysis shows that the samples have hexagonal (wurtzite) structure with no additional peak which suggests that Cr ions fit into the regular Zn sites of ZnO crystal structure. By using Scherrer’s formula for pure and Cr doped ZnO samples the average grain size was found to be 32 nm. Further band gap of pure and doped ZnO samples have been calculated by using UV-Vis spectra. The photo-catalytic degradation of methyl blue dye under UV irradiation was examined for synthesized samples. The results show that the concentration plays an important role in photo-catalytic activity.

36 MATERIALS SCIENCE↗

Effect of chromia doping of thermal stability of silica fibers

Commercial silica fibers of the type being evaluated for reusable surface insulation for reentry vehicles were found to be porous and composed of subfibers. The effect on shrinkage and devitrification of soaking such silica fibers in water, acetic acid, chromium acetate, and chromium nitrate solutions was studied. Felted specimens made of chromia-doped fibers shrunk only about one-half as much as those made of untreated fibers after exposure in air for 4 hours at 1300 C. The devitrification rate of fibers given prolonged soaks in chromium nitrate was as low as that of as-received fibers.

Zaplatynsky, I.↗

Salt-stone Oxidation Study: Leaching Method - 13092

Cementitious waste forms can be designed to chemically stabilize selected contaminants, such as Tc{sup +7} and Cr{sup +6}, by chemically reduction to lower valance states, Tc{sup +4} and Cr{sup +3}, respectively, and precipitation of these species in alkaline media as low solubility solid phases. Data for oxidation of this type of cementitious waste form cured under field conditions as a function of time is required for predicting the performance of the waste form and disposal facility. The rate of oxidation (oxidation front advancement) is an important parameter for predicting performance because the solubilities of some radionuclide contaminants, e.g., technetium, are a function of the oxidation state. A non-radioactive experiment was designed for quantifying the oxidation front advancement using chromium, as an approximate redox-sensitive surrogate (Cr{sup +6} / Cr{sup +3}) for technetium (Tc{sup +7} / Tc{sup +4}). Nonradioactive cementitious waste forms were prepared in the laboratory and cured under both laboratory and 'field conditions'. Laboratory conditions were ambient temperature and sealed sample containers. Field conditions were approximated by curing samples in open containers which were placed inside a plastic container stored outdoors at SRS. The container had a lid and was instrumented with temperature and humidity probes. Sub-samples as thin as 0.2 mm were taken as a function of distance from the exposed surface of the as-cast sample. The sub-samples were leached and the leachates were analyzed for chromium, nitrate, nitrite and sodium. Nitrate, nitrite, and sodium concentrations were used to provide baseline data because these species are not chemically retained in the waste form matrix to any significant extent and are not redox sensitive. 'Effective' oxidation fronts for Cr were measured for samples containing 1000, 500 and 20 mg/kg Cr added as soluble sodium chromate, Na{sub 2}CrO{sub 4}. For a sample cured for 129 days under field conditions, leachable Cr (assumed to be the oxidized form, i.e., Cr{sup +6} was detected in the top 15 to 20 mm of the sample spiked with 1000 mg/kg Cr. Below about 20 mm, the Cr concentrations in leachates were below the detection limit (< 0.010 mg/L) which indicates that the oxidation as the result of exposure to air was limited to the top 20 mm of the sample after exposure for 129 days and that the bulk of the waste form was not affected, i.e., the Cr was stabilized and insoluble. For samples cured in the laboratory, leachable Cr was detected in the top 8 mm of the Cr 1000 sample cured in the laboratory for 37 days. Between 8 and 14 mm, the concentration Cr in the leachate dropped by a factor of about 20 to just above the detection limit. These depth of penetration results indicate that the rate of advancement of the oxidation front for samples spiked with 1000 mg/kg Cr cured under 'field conditions' for 129 days is less than that for the sample cured in the laboratory for 37 days, i.e., 0.156 and 0.216 mm/day, respectively. Additional data are presented for samples spiked with 500 and 20 mg/kg Cr. In summary, cementitious waste forms are porous solids with a network of interconnected pores ranging in diameter from 10 E-10 m to greater than a few mm. The oxidation process is assumed to occur as the result of oxygen transport through the interconnected porosity which may be filled with air, aqueous salt solution, or both. Upon oxidation, the Cr becomes soluble and can be transported in solution through aqueous pore fluid or leachate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of Technetium-99 on Ion Exchange Resin - A Case Study at 200 West Pump and Treat - 17303

The 200 West Pump and Treat (P and T), on the U.S. Department of Energy's Hanford Site and operated by CH2M HILL Plateau Remediation Company, has a 9,464 liters per minute capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume and reduce the mass of contaminants of concern (COCs) by 95 percent in 25 years. The plume is a complex mix of contaminants including technetium-99 (Tc-99), uranium, carbon tetrachloride, chromium, hexavalent chromium, nitrate, and iodine-129 (I-129). Ion exchange (IX), a common treatment approach for Tc-99 used by many nuclear remediation sites, is used to remove uranium and Tc-99 at 200 West P and T. The IX vessels are arranged in a sequence of three to provide a lead, lag and polish vessel. Tc-99 concentrations are monitored monthly to assure good performance of the system. Performance tracking revealed surprising results. On October 14, 2015, the resin in the lead vessels released Tc-99 at concentrations greater than what was being fed. Although Tc-99 was captured by the downstream lag and polish vessels, the facility staff grabbled with the sudden release of Tc-99 entertaining a variety of scenarios that might result in sudden failure of the IX processes. Subsequent sampling indicated Tc-99 removal began a steady return to normal. The incident raised many questions, chief among them whether the same events could recur and undermine Tc-99 treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

200 West Pump and Treat: The First Three Years - 16473

The 200 West Pump and Treat (P and T), on the U.S. Department of Energy's Hanford Site, has a 9,464 liters per minute capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume and reduce the mass of contaminants of concern (COCs) by 95 percent in 25 years. Treatable contaminants include carbon tetrachloride, trichloroethene, chromium, hexavalent chromium, nitrate, iodine-129 (I-129), and technetium-99 (Tc-99). After 3.5 years of continuous operation, the 200 West P and T treated over 10 billion liters of contaminated groundwater and removed over 190,000 kg of nitrate, 9,000 kg of carbon tetrachloride, nearly 5 curies of technetium-99, and smaller quantities of the remaining contaminants. Twenty three extraction wells strategically installed across the plumes pull contamination in from surrounding areas directing contaminated groundwater to the 200 West P and T for treatment. The 200 West P and T successfully removes all contaminants to below cleanup levels which are at (or lower than) the drinking water standard. Twenty one injection wells return treated water to the aquifer providing flow-path control to mitigate migration of contamination toward the Columbia River, a source of drinking water to the communities downstream. Contaminant concentrations in most monitoring wells are declining and the remedy is on target for accomplishing the mass removal goal ahead of schedule. In 2015, the 200 West P and T was expanded to include treatment for uranium from other operable units. With the uranium treatment expansion, the 200 West P and T is capable of cost-effectively treating contaminated groundwater beneath the 194 km{sup 2} Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Information on Technical Impracticability for Remediation of Iodine-129 Contamination

Groundwater in the 200-UP-1 operable unit (OU) is contaminated with carbon tetrachloride, uranium, nitrate, chromium (total and hexavalent), iodine-129, technetium-99, and tritium, associated with past nuclear weapons production activities at Hanford. The preferred alternative described in the 2012 Record of Decision (ROD) for the 200-UP-1 OU Interim Remedial Action includes 35 years of active remediation using a combination of groundwater pump-and-treat and monitored natural attenuation (MNA) for portions of the contaminated groundwater, followed by institutional controls until cleanup levels are met for unrestricted use. As noted in the 200-UP-1 OU interim ROD, no treatment technology for iodine-129 had been found that could achieve the drinking water standard (DWS) of 1 pCi/L for the iodine-129 concentrations present in the 200-UP-1 OU groundwater. Therefore, the 200-UP-1 OU interim ROD specified hydraulic containment of the iodine-129 plume, update of the conceptual model for iodine-129, and further evaluation of potentially applicable iodine-129 treatment technologies. The 200-UP-1 OU interim ROD further stated that in the event a viable treatment technology is not available, the use of a technical impracticability (TI) waiver may need to be considered as part of the final remedy and that this information be gathered concurrently with the technology evaluation. Hence, this report provides information relevant to a TI waiver consideration on the current federal 1 pCi/L DWS for iodine-129 in the 200-UP-1 groundwater OU of the Hanford Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms of Chromium and Uranium Toxicity in Pseudomonas stutzeri RCH2 Grown under Anaerobic Nitrate-Reducing Conditions

Chromium and uranium are highly toxic metals that contaminate many natural environments. We investigated their mechanisms of toxicity under anaerobic conditions using nitrate-reducing Pseudomonas stutzeri RCH2, which was originally isolated from a chromium-contaminated aquifer. A random barcode transposon site sequencing library of RCH2 was grown in the presence of the chromate oxyanion (Cr[VI]O$2-\atop{4}$) or uranyl oxycation (U[VI]O$2+\atop{2}$). Strains lacking genes required for a functional nitrate reductase had decreased fitness as both metals interacted with heme-containing enzymes required for the later steps in the denitrification pathway after nitrate is reduced to nitrite. Cr[VI]-resistance also required genes in the homologous recombination and nucleotide excision DNA repair pathways, showing that DNA is a target of Cr[VI] even under anaerobic conditions. The reduced thiol pool was also identified as a target of Cr[VI] toxicity and psest_2088, a gene of previously unknown function, was shown to have a role in the reduction of sulfite to sulfide. U[VI] resistance mechanisms involved exopolysaccharide synthesis and the universal stress protein UspA. Finally, as the first genome-wide fitness analysis of Cr[VI] and U[VI] toxicity under anaerobic conditions, this study provides new insight into the impact of Cr[VI] and U[VI] on an environmental isolate from a chromium contaminated site, as well as into the role of a ubiquitous protein, Psest_2088.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defining a Metric to Assess Leachability of Contaminants from Cementitious Waste Forms in Lab Testing Related to Hanford - 20478

This paper reports on the determination of performance metrics for the release of four contaminants (technetium, iodine, nitrate, and chromium) from a theoretical supplemental low-activity waste (LAW) inventory of grout in the Hanford Integrated Disposal Facility (IDF). The performance metric was defined as a retardation factor, R, that can be used to quantify a waste form's ability to retain one contaminant compared with an un-retarded species (e.g., sodium). By setting the target R value at the magnitude required to maintain concentrations of the contaminants below the drinking water standard at the point of compliance for the IDF, a bar for grout leach performance can be established for screening laboratory leach test data. The R can be converted to a corresponding laboratory-observed diffusivity value against which to assess leach test data. The individual performance metrics were determined through an iterative set of simulations using a variable saturation and transport flow model of a grout waste form inventory in the IDF to calculate the resulting concentration-based requirements at the point of compliance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetics of chromium ion absorption by cross-linked polyacrylate films

Three cross-linked ion exchange membranes were studied as to their ability to absorb chromium ion from aqueous chromium III nitrate solutions. Attention was given to the mechanism of absorption, composition of the absorbed product, and the chemical bonding. The membranes were: calcium polyacrylate, polyacrylic acid, and a copolymer of acrylic acid and vinyl alcohol. For the calcium polyacrylate and the copolymer, parabolic kinetics were observed, indicating the formation of a chromium polyacrylate phase as a coating on the membrane. The rate of absorption is controlled by the diffusion of the chromium ion through this coating. The product formed in the copolymer involves the formation of a coordination complex of a chromium ion with 6 carboxylic acid groups from the same molecule. The absorption of the chromium ion by the polyacrylic acid membranes appears to be more complicated, involving cross-linking. This is due to the coordination of the chromium ion with carboxylic acid groups from more than one polymer molecule. The absorption rate of the chromium ion by the calcium salt membrane was found to be more rapid than that by the free polyacrylic acid membrane.

May, C. E.↗

In Situ Growth and Interlayer Modulation of Layered Double Hydroxide Thin Films from a Transparent Conducting Oxide Precursor

Layered double hydroxides (LDHs) are a class of cationic-layered solids that can be synthetically designed for a variety of advanced functions. Facile thin film growth of LDHs is an important requisite for a variety of applications including functional coatings, displays, and sensing. In this work we demonstrate, for the first time, an in-situ and patternable thin film synthesis of interconnected Zn-Cr LDH particles from a transparent conducting oxide (TCO) precursor, aluminum-doped zinc oxide (AZO), at room temperature within minutes. Synthetic parameters such as chromium (III) nitrate concentration, solvent composition, and reaction time were found to significantly affect the thickness and morphology of the resulting LDH films. These LDH thin films can undergo interlayer anion exchange, which modulates the interlayer distance of the LDH sheets and surface energy of the thin film. Replacement of the interlayer anion with perfluorooctanoate increases the interlayer sheet distance from 0.9 nm to 2.8 nm and induces a super-hydrophobic thin film that is capable of adsolubilizing and retaining organic guest molecules. The synthetic method and structural analysis of the LDH thin films introduced in this work opens new avenues of application for LDH films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of biofilm in 200W fluidized bed reactors

Contaminated groundwater beneath the 200 West Area at the Hanford Site in Southeast Washington is currently being treated using a pump and treat system to remove organics, inorganics, radionuclides, and metals. A granular activated carbon-based fluidized bed reactor (FBR) has been added to remove nitrate, hexavalent chromium and carbon tetrachloride. Initial analytical results indicated the microorganisms effectively reduced many of the contaminants to less than cleanup levels. However shortly thereafter operational upsets of the FBR include carbon carry over, over production of microbial extracellular polymeric substance (biofilm) materials, and over production of hydrogen sulfide. As a result detailed investigations were undertaken to understand the functional diversity and activity of the microbial community present in the FBR over time. Molecular analyses including terminal restriction fragment length polymorphism analysis, quantitative polymerase chain reaction and fluorescent in situ hybridization analyses were performed on the microbial community extracted from the biofilm within the bed and from the inoculum, to determine functional dynamics of the FBR bed over time and following operational changes. Findings from these analyses indicated: 1) the microbial community within the bed was completely different than community used for inoculation, and was likely from the groundwater; 2) analyses early in the testing showed an FBR community dominated by a few Curvibacter and Flavobacterium species; 3) the final sample taken indicated that the microbial community in the FBR bed had become more diverse; and 4) qPCR analyses indicated that bacteria involved in nitrogen cycling, including denitrifiers and anaerobic ammonia oxidizing bacteria, were dominant in the bed. These results indicate that molecular tools can be powerful for determining functional diversity within FBR type reactors. Coupled with micronutrient, influent and effluent chemistry evaluations, a more complete understanding of the balance between system additions (nutrients, groundwater) and biology can be achieved, thus increasing long-term predictions of performance. These analyses uniquely provide information that can be used in optimizing the overall performance, efficiency, and stability of the system both in real time as well as over the long-term, as the system design is altered or improved and/or new streams are added.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method of forming grooves in the [011] crystalline direction

An A-B etchant is applied to a (100) surface of a body of semiconductor material, a portion of which along the (100) surface of the body is either gallium arsenide or gallium aluminum arsenide. The etchant is applied for at least 15 seconds at a temperature of approximately 80.degree. C. The A-B etchant is a solution by weight percent of 47.5%, water, 0.2% silver nitrate, 23.8% chromium trioxide and 28.5% of a 48% aqueous solution of hydrofluoric acid. As a result of the application of the A-B etchant a pattern of elongated etch pits form having their longitudinal axes along the [011] crystalline direction. Grooves are formed in the body at a surface opposite the (100) surface on which was applied the etchant. The grooves are formed along the [011] crystalline direction by aligning the longitudinal axes of the grooves with the longitudinal axes of the etch pits.

Marinelli, Donald Paul↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Successful In Situ Remediation of Cr(VI)-Impacted Deeper Vadose Zone Soils for Groundwater Protection - 18603

Shallow soil at a former industrial wood treating facility was impacted with chromium, arsenic, and copper above cleanup goals and shallow soil has been excavated for protection of direct contact exposure pathways. Deeper vadose zone soil was predominantly impacted with chromium and was undergoing remediation for long-term groundwater protection. The 920-meter (m) long Cr(VI) groundwater plume has undergone full-scale remediation with groundwater recirculation and in situ bioremediation. Following approximately 4 years of operation, the Cr(VI) groundwater plume, with former source area groundwater concentrations over 10,000 micrograms per liter (μg/L), has been reduced to below the laboratory method reporting limit (0.50 μg/L). Approximately 23,000 cubic meters (m{sup 3}) of deeper (4.5 m - 11 m below ground surface, bgs) vadose zone soil required Cr(VI) remediation. The remediation strategy relied on reduction of Cr(VI) and geochemical fixation as trivalent chromium (Cr(III)) and iron hydroxide precipitates. Chromium reduction was facilitated by a carbon source (corn syrup and methanol) to establish and maintain biogeochemical reducing conditions and ferrous iron to support direct Cr(VI) chemical reduction. Combined, the injected soil moisture, carbon source and ferrous iron supported fast and sustained ferrous/ferric iron cycling and Cr(VI) reduction. Remedy performance monitoring included time-series water quality data from a network of vacuum lysimeters and confirmation soil borings. Reagent was applied either through liquid injection wells and direct-push injection points, or by deep soil mixing methodology in areas with difficult geology (i.e., fine-grained soils and discontinuous iron-silica hardpan layer). Following both phases of deep soil remediation, soils met long-term protection of groundwater remediation action objectives. In situ treatment of soils provides a cost-effective remedial solution compared to excavation, specifically when impacts are deep and long-term protection of groundwater is a primary remediation goal. The delivery methods employed in this case study can be applied to sites impacted with a broad range of contaminants amendable to geochemical fixation (e.g., chromium, uranium, strontium, nitrate, etc.). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid Secondary Waste Form Testing Activities for the Integrated Disposal Facility Performance Assessment Support - 17567

Solid secondary waste (SSW) that will be generated at the Waste Treatment and Immobilization Plant (WTP) and from other activities at the Hanford site is destined for disposal at the Integrated Disposal Facility (IDF). Construction of the IDF was undertaken based on a Performance Assessment (PA) performed in 2001. In 2016, a SSW data package was prepared to support the development of an updated PA (2017 IDF PA). There are many inputs required to support the IDF PA. Data needs were identified based on experience from the previous PAs and from the development of conceptual models and modeling approaches to be applied for the 2017 PA. Interactions with the IDF PA team and the inventory data package developer helped to focus detailed efforts on a few key waste streams, contaminants of concern, and disposal configurations that are expected to be the primary contributors to the dose resulting from SSW disposed at the IDF. The key waste streams include: High Efficiency Particulate Air (HEPA) filters, ion exchange resins, granular activated carbon, and Ag-mordenite. The key parameters addressed in the 2016 data package include: saturated hydraulic conductivity, moisture characteristic curves, effective diffusion coefficient, distribution coefficient and porosity. The IDF PA team also identified a set of key contaminants that are expected to be the primary concern for the PA calculations (Tc-99, I-129, Cs-137, Sr-90, uranium isotopes (and total uranium), chromium, mercury and nitrate). These contaminants were the focus of the SSW data package. Specific formulations had not been identified for cementitious materials that will be used to encapsulate or stabilize SSW, and no IDF-specific experiments had been conducted to obtain the data for the PA. Thus, for the 2016 SSW data package, recommended property values were provided for a range of representative candidate materials based on a review of existing literature. However, starting in FY17, IDF-specific experiments will be performed for Hanford SSW expected to contribute most significantly to the dose for the IDF. This paper will summarize the information obtained for the 2016 data package and the plans for further testing to refine key inputs for the IDF PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Uranium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) Facility at the Hanford Site is a multifunctional groundwater treatment facility consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99) as well as other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T Facility removes U and Tc-99 using ion exchange chromatography. In 2016, the Purolite A530E resin used for the Tc-99 removal was replaced and the spent resin was analyzed. In addition to Tc-99, the Purolite A530E resin also retained I-129 and Co-60; however, the resin loading was dominated by common groundwater constituents such as calcium, iron, silicon, and sulfate.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Technetium Ion Exchange Resin from the 200 West Pump-and-Treat Facility

The 200 West Area Pump-and-Treat (P&T) facility at the Hanford Site is a combined treatment train consisting of unit processes to remove radionuclides such as uranium (U) and technetium (Tc-99), other inorganic (nitrate and hexavalent chromium), and organic (carbon tetrachloride and trichloroethene) contaminants. The RAD building of the P&T facility removes Tc-99 and U using ion exchange chromatography, while the other inorganic and organic contaminants are removed in the facility’s BioPlant portion. The original design of the ion exchange resin for Tc-99 allowed for a 3-month Tc-99 breakthrough and subsequent resin canister change out. However, no Tc-99 breakthrough was noted for 3 years. The objective of the work was to analyze spent resin to determine if there are other compounds that may interfere with Tc-99 adsorption, and to determine whether the resin was removing any I-129.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗