Performance of CID camera X-ray imagers at NIF in a harsh neutron environment
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Identification of peptides through analysis of peptide ion fragmentation mass spectra is key to proteomic/peptidomic studies. Advanced mass spectrometry has enabled measurement of peptide fragments with {approx}ppm mass error levels; however, mass accuracy has not been widely utilized in broad aspects of peptide identification. In this work we describe how peptide high-precision fragments measured with Fourier transform mass spectrometry can provide a powerful discriminative capability to distinguish true peptide 'hits' from possible incorrect peptides. For identification of peptides having multiple termini and carrying multiple charges, we show that the simple utilization of high-precision mass fragments information results in improved peptide analysis coverage and consistency, with coverage of >95% peptides identified totally from different spectral scoring and peptide statistic probability methods developed for moderate accuracy mass spectral peptide identification.
Modeling and simulations have been performed for the charge injected diodes (CID) for the application in SLHC. MIP-induced current and charges have been calculated for segmented detectors with various radiation fluences, up to the highest SLHC fluence of 1 x 10{sup 16} n{sub eq}/cm{sup 2}. Although the main advantage of CID detectors is their virtual full depletion at any radiation fluence at a modest bias voltage (<600 V), the simulation of CID and fitting to the existing data have shown that the CID operation mode also reduces the free carrier trapping, resulting in a much higher charge collection at the SLHC fluence than that in a standard Si detector. The reduction in free carrier trapping by almost one order of magnitude is due to the fact that the CID mode also pre-fills the traps, making them neutral and not active in trapping. It has been found that, electron traps can be pre-filled by injection of electrons from the n{sup +} contact, and hole traps can be pre-filled by injection of holes from the p{sup +} contact. The CID mode of detector operation can be achieved by a modestly low temperature of around -40 C, achievable by the proposed CO{sub 2} cooling for detector upgrades in SLHC. High charge collection comparable to the 3D electrode Si detectors makes the CID Si detector a valuable alternative for SLHC detectors for its much easier fabrication process.
We report on use of an Orbitrap Velos mass spectrometer for comparison of fragmentation methods namely CID-, HCD-, and ETD for FT MS/MS analysis of human blood plasma peptidomic peptides. The peptidomic peptides were able to be identified from CID, HCD, and ETD spectra on specific confidence levels (e.g., 1% false discovery rate) with use of conventional SEQUEST database search software, and the number of identified peptides was increased by ~50% using accurate fragments (e.g., with mass tolerance of 0.05Da) in comparison with traditional moderate accuracy fragments (e.g., with 1 Da mass tolerance) for database search. However, the peptide datasets identified with such decoy search strategy were found to be varied by ~25% in the dataset size and ~20% in the dataset content with type of decoy database and precursor mass tolerances used for database search. CID was evaluated as the largest contributor to the identified peptide datasets, and HCD, and ETD provided ~20% and ~22% respectively additional peptides with accurate fragments for peptide identification, in contrast to ~25% and ~13% respectively with use of moderate accuracy fragments. When long (typically ≥7 amino acids) sequences were used for identification of peptides from the previously published UStags and de novo sequencing methods, HCD was evaluated as the largest contributor, and CID and ETD provided ~26% and ~8% respectively additional peptides from the UStags method and ~26% and ~6% respectively additional peptides from the de novo sequencing method. The peptide datasets identified with the UStags method were little influenced by the decoy database and mass tolerance and 98-99% peptide overlaps could be achieved between these datasets. CID, HCD, and ETD contributed their identifications of various charge state peptides in the m/z range highly overlapped and complementary implementation of CID, HCD, and ETD should be applied to maximize the number of peptides identified. Finally, the investigation presented in this work suggests that selection of fragmentation methods benefits significantly from a careful match with data analysis method applied for identification of peptides and the analysis throughput desired for various purposes of peptidomic-degradomic analysis.
The galaxy CXOC J100043.1+020637, also known as CID-42, is a highly unusual object. An apparent galaxy merger remnant, it displays signatures of both an inspiraling, kiloparsecscale active galactic nucleus (AGN) pair and of a recoiling AGN with a kick velocity approximately greater than 1300 km s(exp -1). Among recoiling AGN candidates, CID-42 alone has both spatial offsets (in optical and X-ray bands) and spectroscopic offsets. In order to constrain the relative likelihood of both scenarios, we develop models using hydrodynamic galaxy merger simulations coupled with radiative transfer calculations. Our gas-rich, major merger models are generally well matched to the galactic morphology and to the inferred stellar mass and star formation rate. We show that a recoiling supermassive black hole (SMBH) in CID-42 should be observable as an AGN at the time of observation. However, in order for the recoiling AGN to produce narrow-line emission, it must be observed shortly after the kick while it still inhabits a dense gaseous region, implying a large total kick velocity (vk approximately greater than 2000 km s(exp -1)). For the dual AGN scenario, an unusually large broad-line offset is required, and the best match to the observed morphology requires a galaxy that is less luminous than CID-42. Further, the lack of X-ray emission from one of the two optical nuclei is not easily attributed to an intrinsically quiescent SMBH or to a Compton-thick galactic environment. While the current data do not allow either the recoiling or the dual AGN scenario for CID-42 to be excluded, our models highlight the most relevant parameters for distinguishing these possibilities with future observations. In particular, high-quality, spatially-resolved spectra that can pinpoint the origin of the broad and narrow line features will be critical for determining the nature of this unique source.
A heavily irradiated (3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2}) Current Injected Detector (CID) was tested with 225 GeV muon beam at CERN H2 beam line. In the CID concept the current is limited by the space charge. The injected carriers will be trapped by the deep levels and this induces a stable electric field through the entire bulk regardless of the irradiation fluence the detector has been exposed to. The steady-state density of the trapped charge is defined by the balance between the trapping and the emission rates of charge carriers (detrapping). Thus, the amount of charge injection needed for the electric field stabilization depends on the temperature. AC-coupled 16 cm{sup 2} detector was processed on high resistivity n-type magnetic Czochralski silicon, and it had 768 strips, 50 {mu}m pitch, 10 {mu}m strip width and 3.9 cm strip length. The beam test was carried out using a silicon beam telescope that is based on the CMS detector readout prototype components, APV25 readout chips, and eight strip sensors made by Hamamatsu having 60 {mu}m pitch and intermediate strips. The tested CID detector was bonded to the APV25 readout, and it was operated at temperatures ranging from -40 to -53 C. The CID detector irradiated at 3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2} fluence shows about 40% relative Charge Collection Efficiency with respect to the non-irradiated reference plane sensors.
We present Chandra High Resolution Camera observations of CID-42, a candidate recoiling supermassive black hole (SMBH) at z = 0.359 in the COSMOS survey. CID-42 shows two optical compact sources resolved in the HST/ACS image embedded in the same galaxy structure and a velocity offset of {approx}1300 km s{sup -1} between the H{beta} broad and narrow emission line, as presented by Civano et al. Two scenarios have been proposed to explain the properties of CID-42: a gravitational wave (GW) recoiling SMBH and a double Type 1/Type 2 active galactic nucleus (AGN) system, where one of the two is recoiling because of slingshot effect. In both scenarios, one of the optical nuclei hosts an unobscured AGN, while the other one, either an obscured AGN or a star-forming compact region. The X-ray Chandra data allow us to unambiguously resolve the X-ray emission and unveil the nature of the two optical sources in CID-42. We find that only one of the optical nuclei is responsible for the whole X-ray unobscured emission observed and a 3{sigma} upper limit on the flux of the second optical nucleus is measured. The upper limit on the X-ray luminosity plus the analysis of the multiwavelength spectral energy distribution indicate the presence of a star-forming region in the second source rather than an obscured SMBH, thus favoring the GW recoil scenario. However, the presence of a very obscured SMBH cannot be fully ruled out. A new X-ray feature, in a SW direction with respect to the main source, is discovered and discussed.
microRNAs (miRNA) are a class of non-protein coding functional RNAs that are thought to regulate expression of target genes by direct interaction with mRNAs. miRNAs have been identified through both experimental and computational methods in a variety of eukaryotic organisms. Though these approaches have been partially successful, there is a need to develop more tools for detection of these RNAs as they are also thought to be present in abundance in many genomes. In this report we describe a tool and a web server, named CID-miRNA, for identification of miRNA precursors in a given DNA sequence, utilising secondary structure-based filtering systems and an algorithm based on stochastic context free grammar trained on human miRNAs. CID-miRNA analyses a given sequence using a web interface, for presence of putative miRNA precursors and the generated output lists all the potential regions that can form miRNA-like structures. It can also scan large genomic sequences for the presence of potential miRNA precursors in its stand-alone form. The web server can be accessed at (http://mirna.jnu.ac.in/cidmirna/)
ABSTRACT As gravitational-wave (GW) interferometers become more sensitive and probe ever more distant reaches, the number of detected binary neutron star mergers will increase. However, detecting more events farther away with GWs does not guarantee corresponding increase in the number of electromagnetic counterparts of these events. Current and upcoming wide-field surveys that participate in GW follow-up operations will have to contend with distinguishing the kilonova (KN) from the ever increasing number of transients they detect, many of which will be consistent with the GW sky-localization. We have developed a novel tool based on a temporal convolutional neural network architecture, trained on sparse early-time photometry and contextual information for Electromagnetic Counterpart Identification (El-CID). The overarching goal for El-CID is to slice through list of new transient candidates that are consistent with the GW sky localization, and determine which sources are consistent with KNe, allowing limited target-of-opportunity resources to be used judiciously. In addition to verifying the performance of our algorithm on an extensive testing sample, we validate it on AT2017gfo – the only EM counterpart of a binary neutron star merger discovered to date – and AT2019npv – a supernova that was initially suspected as a counterpart of the GW event, GW190814, but was later ruled out after further analysis.
The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.
A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.
On December 1, 1984, NASA and the Federal Aviation Administration (FAA) conducted the first remotely piloted air-to-ground crash test of a transport category aircraft. The Full-Scale Transport Controlled Impact Demonstration (CID) was the culmination of 4 years of effort by the two agencies. NASA and the FAA had many objectives during the joint planning and execution of the Controlled Impact Demonstration. The structural loads experiment was very successful. Ninety-seven percent of the channels were active at impact. The data is still being assessed. Only a portion of the data is presented here; approximately 80 channels of data are available. Analysis of the remaining data is in progress. Interior photography was also very successful. One hundred percent of the cameras functioned. The film contains unique information on the development of fire and smoke in the interior of the aircraft. From a human tolerance point of view, the CID was simulation of a survivable crash.
A study involving the Controlled Impact Demonstration (CID) of a transport category aircraft was conducted with the objective to improve occupant safety during survivable crash scenarios. in connection with this study, the first remotely-piloted Full-Scale Transport aircraft was purposely crashed into the California desert. The program was initated to demonstrate the effectiveness of an imisting kerosene (AMK), a fuel additive emplyed to reduce postcrash fires. The unmanned CID flight carried 73 life-like flight research dummies, multiple experiments, high-speed interior cabin cameras, and the high-environment Crash Response Data System. Attention is given to the design approach, a block diagram of the Crash Response Data System, measurements, the digital data subsystem, signal conditioning, telemetry, on-board recording, the power subsystem, preflight checkout and calibration, and aspects of system qualification.
The source of hydrogen in the formation of c- and y-ions produced by intramolecular hydrogen transfer in negative-ion CID experiments with peptides has been examined using Cα-, Cβ-, and backbone amide (N{sub b})-deuterated peptides AAA(d3)AA, AAG(d2)AA, AAAG(d2)A, and AAAAA-d7, as well as five other peptides. The c- and y-ions produced by deuterium transfer from the deuterated residues were detected and identified by the exact m/z values obtained with a high-resolution orbitrap mass spectrometer. The rate of deuterium transfer obtained indicates that over 50% of the hydrogen was originated from the backbone amide nitrogen, with the residual hydrogen coming from the backbone Cα. It is clear that the hydrogen does not originate from the side chain Cβ. It is hypothesized that the intramolecular hydrogen transfer to form negative c- and y-ions takes place via 3-, 4-, 6-, 7-, 8-, and 9-membered ring transition states. .
Cactodera torreyanae Cid del Prado Vera & Subbotin, 2014 cysts were discovered during a Pale Potato Cyst Nematode (PCN) survey conducted by Minnesota Department of Agriculture as part of the Animal and Plant Health Inspection Service (APHIS) efforts to survey states for the presence of PCN. The soil samples were collected from a potato field, located in Karlstad, Kittson County, Minnesota, USA. Two out of 175 vials submitted for identification to the Mycology and Nematology Genetic Diversity and Biology Laboratory (MNGDBL) contained few cysts and juveniles of C. torreyanae. Cysts were dark brown in color, lemon-shaped to elongated with distinct vulval cone. Vulva with denticles present around fenestra, cyst length to width ratio between 1.6 and 2.3 and anus distinct. The juveniles had rounded stylet knobs, some sloping slightly posteriorly. The molecular analysis included sequence and phylogenetic analysis of ITS rRNA, D2-D3 expansion segments of 28S rRNA and COI of mtDNA genes. The nematode species was identified by both morphological and molecular means as Cactodera torreyanae. To the best of our knowledge this represents the first report of Cactodera torreyanae from the United States and first report of this cyst nematode species from potato fields. Definite host plant for this nematode remains unknown.
Readout of CID imaging arrays was first performed by injecting and detecting the signal charge from each sensing site in sequence. A new readout method, termed parallel injection, has been developed in which the functions of signal charge detection and injection have been separated. The level of signal charge at each sensing site is detected during a line scan, and during the line retrace interval, all charge in the selected line is injected. The parallel injection technique is well adapted to TV scan formats in that the signal is read out at high speed, line by line. A 244 line by 248 element TV compatible imager, employing this technique and including an on chip preamplifier, has been constructed and operation demonstrated.
The characteristics of two kinds of detectors are summarized with emphasis on those aspects that would affect their use in high accuracy astronomical photometry. The first type, the multianode microchannel arrays (MAMA), are a family of pulse counting array detectors. Components and operation principles are reviewed and quantum efficiency, noise characteristics, and dynamic range characteristics are described. The second type, charge injection devices (CID), are discussed in reference to their applicability to photometric detection at optical wavelengths.
An optical imager, called the Scanning Imaging Spectroradiometer (SIS), was built for NASA in the early 1970's. Later, the Solidstate Array Spectroradiometer (SAS) was developed on the basis on a substitution of a Charge Injection Device (CID) array for the vidicon of the SIS. The Advanced Solidstate Array Spectroradiometer (ASAS) represents an improvement of the SAS. ASAS is a solidstate multispectral optical imaging radiometer which is currently the most versatile instrument of its type in the visible part of the spectrum. The instrument is capable of absolute radiometric measurements in all of its 32 bands. ASAS can be easily mounted in small aircraft as well as high altitude craft such as the U-2, taking into account also the possibility of a use in the Space Shuttle. The instrument consists of three separate subsystems. Attention is given to the optics, the detector array, data storage, data retrieval, and system performance.