A Framework to Demonstrate a DNP3 Interface with a CIM-Based Data Integration Platform
This poster was presented at the 2024 IEEE Power & Energy Society General Meeting, July 21-25, 2024, Seattle, Washington.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This poster was presented at the 2024 IEEE Power & Energy Society General Meeting, July 21-25, 2024, Seattle, Washington.
The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.
As the nuclear power plants are in operation for many years, a main issue is to integrate simulation activities in parallel to the present I and C design process in order to limit impacts on current operating I and C engineering process and commissioning activities. The objective is to keep the existing I and C data and diagrams format. EDF chose to build an intermediate file independent of the tool used for simulation to exchange and store data. This file has been created adapting CIM standards (IEC 61968-13 and IEC 61970-301). It is an XML file built according to an RDF schema. CIM standards are intended to model transport or distribution electrical networks and used to facilitate system integration and information exchanges. We chose to adapt CIM to model EDF electromechanical relay circuitries in order to re-use all methods and tools developed around CIM standards such as RDF schema and RiseClipse, an open source tool developed by EDF and SUPELEC engineering school that will be used to verify exported I and C data according to a data model and to EDF engineering rules. This paper will describe the ongoing project on simulation in parallel to current I and C design process, focusing on how I and C electromechanical relays data are modelled based on CIM standards, and what benefits that model provides to I and C Verification and Validation activities. (authors)
Extracting Attributes in a Simple DictionarY of CIM (EASY-CIM) is a python library to reduce the time and burden of model queries using simplified data representations of CIM power system models.
The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.
The negative ion measurements were taken using two LTOF-CIMS with two different nitrate inlets. The data labeled Aerodyne_Inlet used an Aerodyne nitrate inlet. Data labeled PCC used a custom transverse inlet. The positive ion measurements were taken using one LTOF-CIMS with hydronium as an ionization reagent using a custom transverse inlet with an inlet voltage difference of 700 V. See https://doi.org/10.1021/acs.jpca.2c01672 for more information. Peaks were autofit using tofware. Positive ion data is published in the form of peak signal/reagent signal. Data files of peak signal/reagent signal for the two mass spectrometers for the negative ion measurements are separate. Concentrations of H2SO4 are combined into one file. When measurements were overlapping, measurements from the Aerodyne nitrate inlet were used.
With the proliferation of distributed energy resources and advanced metering, modern electric power distribution systems are data rich and include advanced capabilities for distribution automation. Distribution utilities need applications for planning and operations that can integrate all the available data from the enterprise applications and may incorporate distributed approaches to operate and control. This paper describes a framework for standardizing and integrating the data available at different vendor specific applications in a utility utilizing the Common Information Model (CIM). Theframework incorporates the conversion of these the standardized CIM models into models compatible with GridLAB-D, an open source distribution system simulator, for developing advanced planning and operation strategies.
The Molecular Dynamics technique Collective variable hyperdynamics (CVHD) interfaced with density functional tight-binding at the GFN1-xTB and GFN2-xTB levels of electronic structure theory has been applied to the H + GAG positively charged peptide system to explore the fragmentation of this simple tripeptide under relatively low temperature/energy conditions. Unlike conventional chemical dynamics simulations which can only be performed up to hundreds of picoseconds when coupled with semi-empirical Hamiltonians, CVHD is able to capture the long-time dynamics of multiple proton hopping, the formation of reversible ring structures, and ester rearrangement of the H + GAG system prior to fragmentation. The CVHD method applied to H + GAG is also able to uncover alternative fragmentation pathways not considered previously such as glycine fragmentation on the N-terminal side of the charged peptide and new cyclic cationic species. These findings in the H + GAG case have implications for other peptide systems.
The contemporary electrical grid is characterized by its complexity and abundance of data. A control-rich environment supported by information and communication technologies within an Advanced Distribution Management System (ADMS) presents a viable and cost-effective option for utility companies aiming to implement advanced real-time analytical schemes for monitoring and remotely controlling distribution feeders. Modular platform-based approaches to distribution operations require a structured framework for acquiring field device measurements, performing analytics, converting the setpoint to the correct protocol, and sending it on the appropriate communications network to the field devices. We present the development and deployment of an application service to integrate an open-source standardsbased platform with an ADMS test bed with field devices using the Distributed Network Protocol (DNP3) for data exchange. The step-by-step procedure for establishing the DNP3-Master service on an open-source distribution platform is outlined, comprehensively explaining the Master setup process. Moreover, sample use case results highlight the capabilities of the DNP3- Master service setup. Results demonstrate the scalability and configurability of the DNP3-Master service, making it adaptable for integration with other relevant applications, thus providing potential opportunities for real-world field trials and real-time assessments.
Not Available
Here, in this work, we present a variation-tolerant and energy-efficient charge-domain Ferroelectric FET (FeFET) based Compute-in-Memory (CiM) array design that is compatible with both binary and multi-level cell memory sensing. We demonstrate that: 1) by exploiting FeFET as a nonvolatile switch, its high ON/OFF ratio in the subthreshold region can suppress the error introduced by the inaccurate ON state conductance, thus realizing robust CiM operations, unlike the current-domain CiM design where the computation results is highly sensitive to the device conductance variation; 2) by leveraging a dense dynamic random access memory (DRAM)-like 1FeFET1C cell structure, the proposed design benefits from the existing high density DRAM establishment while also significantly relaxing the capacitor retention and transistor leakage requirement; 3) the charge-domain CiM supports both binary FeFET with minimum overhead and MLC FeFET with tolerable latency for MLC state sensing, whose efficacy is validated experimentally on both cell-level and array-level; 4) the proposed CiM shows much better device variation resilience than conventional current-domain CiM, and also improves inference accuracy. Macro-level evaluation results demonstrate significantly higher energy efficiency and area efficiency compared to prior CiM works.
The Common Information Model (CIM) is an open-source information model that is used to model an electrical network and the various equipment used on the network. CIM is widely used for data exchange of bulk transmission power systems and is finding increasing use for distribution systems. Use of a non-proprietary information model (such as CIM) that has been agreed upon and adopted by numerous utilities, vendors, and researchers allows significant reduction in the effort and cost of data integration. Likewise, adoption of open data platforms built around the CIM increases available functionalities for managing and optimizing the smart grid of the future. This report is intended as an introduction to CIM for utility engineers, power systems researchers, and application developers, providing a broad view of the CIM and how particular profiles can be adapted for various use cases. Unlike most other CIM introduction documents and the International Electrotechnical Commission (IEC) standards (which are mostly targeted to an audience of data scientists, enterprise database managers, and platform developers), this report is intended for users of traditional power systems analysis software and other readers without any prior experience with canonical information models, data profiles, or UML modeling.
A key issue in creating the next generation of energy management system (EMS) and advanced distribution management system (ADMS) platforms will be the ability to represent and exchange power system network model data in a consistent manner. To this end, the Common Information Model (CIM) stands out as the only standardized vocabulary (or ontology) for defining power system network models and asset data in a comprehensive, consistent manner across the generation-transmission-distribution boundary. The CIM is freely available to use and extend. The CIM is maintained by the UCAiug (informally known as the CIM User’s Group) under an Apache 2.0 license. The CIM Users Group collaborates with the IEC and other standards communities for the development of technical and informative specifications. Although portions of the information model are referred to by the corresponding IEC standards naming, it is not necessary to purchase any of the IEC standards to use the CIM information model. This document provides a roadmap for power system engineers and application developers not familiar with semantic modeling to start using the CIM for modeling, simulation, optimization, and development of advanced power applications. The key classes needed for defining power system topology and equipment are explained systematically. Key focus areas include modeling of lines, transformers, generators, switching equipment, loads, and distributed energy resources (DERs).
The goal of this study is to address fundamental limitations to achieving diesel-like efficiencies in heavy duty on-highway natural gas (NG) engines. Engine knock and misfire are barriers to pathways leading to higher efficiency engines. This study explores enabling technologies for development of high efficiency stoichiometric, spark ignited, natural gas engines. These include design strategies for fast and stable combustion and higher dilution tolerance. Additionally, advanced control methodologies are implemented to maintain stable operation between knock and misfire limits. To implement controlled end- gas autoignition (C-EGAI) strategies a Combustion Intensity Metric (CIM) is used for ignition control with the use of a Woodward large engine control module (LECM). Tests were conducted using a single cylinder, variable compression ratio, cooperative fuel research (CFR) engine with baseline conditions of 900 RPM, engine load of 800 kPa indicated mean effective pressure (IMEP), and stoichiometric air/fuel ratio. Exhaust gas recirculation (EGR) tests were performed using a custom EGR system that simulates a high pressure EGR loop and can provide a range of EGR rates from 0 to 40%. The experimental measurements included the variance of EGR rate, compression ratio, engine speed, IMEP, and CIM. These five variables were optimized through a Modified Box- Benken design Surface Response Method (RSM), with brake efficiency as the merit function. A positive linear correlation between CIM and f-EGAI was identified. Consequently, CIM was used as the feedback control parameter for C-EGAI. As such, implementation of C-EGAI effectively allowed for the utilization of high EGR rates and CRs, controlling combustion between a narrower gap between knock and lean limits. The change from fixed to parametric ignition timing with CIM targeted select values of f-EGAI with an average coefficient of variance (COV) of peak pressure of 5.4. The RSM efficiency optimization concluded with operational conditions of 1080 RPM, 1150 kPa IMEP, 10.55:1 compression ratio, and 17.8% EGR rate with a brake efficiency of 21.3%. At this optimized point of peak performance, a f-EGAI for C-EGAI was observed at 34.1% heat release due to auto ignition, a knock onset crank angle value of 10.3° aTDC and ignition timing of - 24.7° aTDC. This work has demonstrated that combustion at a fixed f-EGAI can be maintained through advanced ignition control of CIM without experiencing heavy knocking events.
Smart grids with interoperability improve grid reliability by collecting system information and transferring it to an energy management system and associated applications through a seamless end-to-end connection. To achieve interoperability, it is required to exchange the semantic information within the different domains. The international electrotechnical commission has established the Common Information Model (CIM) tool, which is a standard application programming interface for the exchange of semantic information in power systems. CIM provides a robust framework for accurate data sharing, merging, and transformation into reusable information. However, as CIM provides a basic framework for information exchange, various practical issues arise in establishing an energy management system capable of exchanging information using CIM. This paper aims to offer a comprehensive understanding by summarizing and categorizing the research on the practical use of CIM for interoperability in smart grids. Many papers are analyzed and the issues are classified into CIM extension, harmonization, and validation to address the issues that arise when establishing an integrated information exchange system.
Ion mobility separations are usually performed in linear channels, which, when extended, can have a large footprint. In this work, we explored the performance of an ion mobility device with a curved architecture which can have a more compact form. The Co-centric Ion Mobility Spectrometer (CIMS) works by manipulating ions between two co-centric surfaces, each containing a serpentine track. The mobility separation inside CIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside CIMS, they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path in structures for lossless ion manipulations (SLIM). We then performed experimental validation of CIMS in conjunction with a TOF MS. The CIMS was made of 2 flexible printed circuit board materials folded into concentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter × 152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and 8 peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). For tetraalkylammonium ions, the average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW). For the peptide mixture ions, the resolving power was similar among the four TW profiles and ranged from 51 to 56. The average percent error in TW CCS for the peptide mixture ions ranged was about 0.4%. In conclusion, the new device showed promising results for a device made of a flexible printed circuit board material, but improvements are needed to further increase the resolving power.
The distribution Common Information Model (CIM) offers a means for interoperable distribution system applications. Adoption has been slow in part because of the steep learning curve, and the mismatch between CIM’s object-oriented schema and widely-used relational database schemas. We evaluated alternative database technologies, and tested a triple-store database with SPARQL queries on a set of IEEE distribution test feeders. These alternative queries were much simpler to design and use, so they should help lower one of the important barriers to CIM adoption. An open-source platform has been provided for other developers to work with CIM in this way. One use case is to more rapidly develop interoperable ADMS and DERMS applications. Another use case is to convert feeder models between commercial CIM-compliant products and research software like GridLAB-D and OpenDSS.