Search NASASearch

SEARCH · Search NASA

Results for “CIRCULAR PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Calculating the space-charge-limited current density for nonplanar geometries by simulating the charge-free electric field

Calculating the space-charge-limited-current density (SCLCD) for a complicated diode geometry often requires computationally expensive particle-in-cell (PIC) codes. Here, this paper addresses this issue by using the charge-free electric field $E_0$ calculated using COMSOL Multiphysics to determine local and global SCLCD. The SCLCD obtained by using the surface average of $|E_0|^2$ on the cathode recovers theoretical results for one-dimensional (1D) planar, cylindrical, and tip-to-tip geometries in appropriate limits. We next compared tip-to-tip calculations with the SCLCD obtained using the PIC code Empire. The SCLCD calculated using COMSOL agreed well with Empire for flatter 1D tip-to-tip geometries and diverged with increasing sharpness. Physically, Empire predicts lower SCLCD than COMSOL because the electrons spread due to concentrated space-charge at the tip, whereas theory assumes that the electrons follow the charge-free electric field lines. We further assess the behavior of the SCLCD for tips protruding from the centers of flat, circular plates of various areas. Larger plate areas with constant tip size recover the 1D planar SCLCD globally and 1D tip-to-tip SCLCD locally, while reducing the difference between Empire and COMSOL calculations since larger plates capture more of the emitted electrons, reducing SCLCD suppression due to beam spreading. These results show that charge-free electric field simulations can be used to determine the SCLCD without needing to simulate particle dynamics in PIC.

Wright, Jack K. [Purdue Univ., West Lafayette, IN

A Measurement of Atmospheric Circular Polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 yr of observational data with the POLARBEAR project. Nonidealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While POLARBEAR detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is 0.92 ± 0.01(stat) ± 0.07(sys). This ratio corresponds to a brightness temperature of 3.8 mK at the effective band center of 121.8 GHz and bandwidth of 3.5 GHz estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measure circular polarization in such experiments.

79 ASTRONOMY AND ASTROPHYSICS

Polarization‐Engineered Near‐Field Generation Using a Hybrid Tip–Antenna System

Precise control of light polarization at the nanoscale is critical for accessing chiral optical responses and manipulating spin–photon interactions in advanced materials. Yet, conventional scattering-type near-field probes predominantly generate out-of-plane linear polarization and offer little control over phase or polarization state. Here, in this study, we introduce a polarization-engineered near-field methodology based on a combined metallic tip and planar dipole nanoantenna system. Using full-wave electromagnetic simulations, we show that the tip acts as a vertically oriented plasmonic resonator, while the antenna supports an in-plane dipolar mode. By tuning the tip–antenna geometry and tip height, the two orthogonal field components attain comparable amplitudes and a controllable ∼90° phase offset, producing circularly polarized nano-light in the antenna gap. The proposed system effectively functions as a nanoscale quarter-wave plate, converting linearly polarized illumination into circularly polarized hotspots without external polarization optics. This method establishes an experimentally accessible route toward polarization-programmable near-field nanoscopy, enabling chiral spectroscopy, selective excitation of spin/valley degrees of freedom, and quantum optical investigations at the nanoscale.

36 MATERIALS SCIENCE

Characterization of a multi-kW, large-aperture gas-cooled Faraday rotator

We characterize a large-aperture gas-cooled Faraday rotator (FR) designed to mitigate stress-induced depolarization in high-energy, high-power laser systems. The rotator, based on ceramic TGG, was tested using a 150 mW probe beam at 1047 nm and a pump beam at 1070 nm. Compensating for the birefringence induced by the surrogate depolarization plate at 3.3 kW of effective pump power, the rotator reduces the spatially in-homogeneous depolarized light containing linear, circular, and elliptical polarization states to nearly linear with approximately 0.8% (or −21 dB) of residual depolarized energy. The FR demonstrated effective depolarization compensation across its 58×58 mm 2 aperture.

47 OTHER INSTRUMENTATION

3D-printed mirror-less helicity preserving metasurface “mirror” for THz applications

Stimulated by seminal works on generalized reflection and refraction laws, metasurfaces have evolved to a highly promising research direction, as they allow a multitude of different functionalities by optically thin wave-control elements/structures. Among them, structures functioning in the low THz regime are of extensive research interest, due to their high potential in communication and sensing applications. In this paper we propose a simple THz metasurface design that exhibits ideally perfect cross-polarized reflection for linear polarization and perfect helicity-preserving reflection with a geometric (Pancharatnam–Berry) phase for circular polarization, without the presence of any back-reflector. Numerical calculations demonstrating the structure response are justified by analytical models, which provide physical insights on this response. The designed metasurfaces are fabricated using the direct laser writing 3D-printing technology, metallized with electroless silver plating, and are characterized by THz time domain spectroscopy, with the experimental results validating the corresponding theoretical ones. Applications including beam steering and focusing, exploring the Pancharatnam–Berry phase, are also demonstrated numerically. Besides those applications, the helicity preserving mirror response of our metasurfaces can be valuable, among others, also in molecular chirality sensing applications, an issue that is also highlighted here.

3D-printed metasurfaces

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE

Development of a broadband reflective phase retarder to generate circularly polarized light for MTW-OPAL and multipetawatt lasers

Here, our research focuses on designing metallic coatings to create broadband all-reflective phase retarders that generate circularly polarized (CP) light for the MTW-OPAL Laser System while ensuring the desired polarization state on the target. This all-reflective phase retarder can function as a phase retarder when used in an out-of-plane configuration, whereas it acts as a normal mirror set in an in-plane configuration. If the polarization of the beam is not purely s- or p-polarized, however, mirrors will in general introduce retardance, and therefore compensators or polarization-independent mirror pairs are needed to ensure the desired polarization at the target plane.

47 OTHER INSTRUMENTATION

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION