At least 19 records

Reservoir Characterization and Techno-Economic Analysis of Enhanced Geothermal and Closed-Loop Systems in the Wattenberg Field of the Denver-Julesburg Basin, Colorado

This report provides details of reservoir characterization and techno-economic analysis for enhanced geothermal systems and closed-loop geothermal systems in the Denver-Julesburg Basin Wattenberg area. The analysis contributes to the Geothermal Limitless Approach to Drilling Efficiencies (GLADE) project, a multi-institutional research initiative focused on advancing geothermal energy development by reducing drilling costs and improving the rate of penetration. The GLADE project brings together national laboratories, academic institutions, and industry partners, including the U.S. Department of Energy's Geothermal Technologies Office, Occidental Petroleum, the National Laboratory of the Rockies (NLR), Los Alamos National Laboratory, Colorado School of Mines, Louisiana State University, Texas A&M University, and several drilling technology companies. As part of this effort, NLR developed and applied slender-body theory modeling tools and the GEOPHIRES simulator to support techno-economic analysis. The slender-body theory wellbore simulator evaluated thermal performance in U-loop, Eavor-type multilateral, and enhanced geothermal system well configurations. Results indicated that an optimized single U-loop design delivers an outlet temperature of 168.8 degrees Celsius,stabilizing at a final outlet temperature of 135.3 degrees Celsius. Heat production also improved significantly, with an average thermal output of 16.9 MWth and a final thermal output of 11.0 MWth. These results provided critical baseline data for selecting optimized systems for techno-economic analysis. Building on these outputs, NLR applied the GEOPHIRES techno-economic simulator to estimate the levelized cost of electricity for both the Eavor multilateral and enhanced geothermal systems. The sensitivity analysis showed that drilling costs exert a particularly strong impact on the levelized cost of electricity of multilateral systems. Therefore, advances in drilling technology and improved drilling rates could yield significant gains in the economic performance of these systems. In this context, the GLADE project directly supports the U.S. Department of Energy's mission to reduce the cost of geothermal energy and accelerate the deployment of next-generation geothermal technologies.

15 GEOTHERMAL ENERGY

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY

CFD modeling of natural circulation in LiCl-KCl molten salt closed loop

Characterizing flow within a molten salt closed-loop system is crucial for assessing system requirements, evaluating performance, and identifying potential flaws. Direct flow measurement using instrumentation is challenging due to extreme environmental conditions and the limitations associated with measuring molten salt flow under natural convection. Here, this study aims to provide comprehensive insights into the thermal-hydraulic behavior of a closed loop, with a particular focus on temperature distribution and velocity prediction. The Computational Fluid Dynamics (CFD) model demonstrated the capability to effectively simulate and predict both temperature distributions and flow velocities within the molten salt loop. The CFD model's predictive capability was validated by its ability to replicate temperature measurements under varying boundary conditions. The analysis revealed that the CFD model tends to underpredict temperatures in the cold leg and overpredict them in the hot leg, highlighting the need for continuous model refinement and acknowledging the limitations of using a steady-state approach. Furthermore, the potential of using external temperature measurements to estimate internal molten salt temperatures and predict flow velocity was explored, revealing that this approach could introduce up to a 5.5% error in flow velocity calculations. Line probes mapping temperature distributions across the tube's cross-section and molten salt provided valuable insights into temperature gradients, emphasizing the need for a thermal conductivity equation for molten salt with lower uncertainty to achieve more accurate temperature predictions of the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Data-Conforming Data-Driven Control: Avoiding Premature Generalizations Beyond Data

Data-driven and adaptive control approaches face the problem of introducing sudden distributional shifts beyond the distribution of data encountered during learning. Therefore, they are prone to invalidating the very assumptions used in their own construction. This is due to the linearity of the underlying system, inherently assumed and formulated in most data-driven control approaches, which may falsely generalize the behavior of the system beyond the behavior experienced in the data. This article seeks to mitigate these problems by enforcing consistency of the newly designed closed-loop systems with data and slowing down any distributional shifts in the joint state-input space. This is achieved through incorporating affine regularization terms and linear matrix inequality constraints to data-driven approaches, resulting in convex semi-definite programs that can be efficiently solved by standard software packages. We discuss the optimality conditions of these programs and then conclude this article with a numerical example that further highlights the problem of premature generalization beyond data and shows the effectiveness of our proposed approaches in enhancing the safety of data-driven control methods.

97 MATHEMATICS AND COMPUTING

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Plan 2 (PIP-II) centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line. It is a critical system that defines the ideal path for the beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40 C. Utilizing an actively regulated heating system, a metal-oxide-semiconductor field-effect transistor (MOSFET) based power control circuit which provides input to a controller; forming a closed-loop system that maintains the desired setpoints with high precision.

Mosher, Alexander [U. Illinois, Chicago]

Highly crystalline, low-ash, graphite from coal using an Fe 2 O 3 -based catalytic process with recovery and reuse of catalyst and process acid

This study presents a sustainable process for producing highly crystalline, low-ash graphite from sub-bituminous coal using an Fe 2 O 3 -based catalytic method. The process integrates coal mineral removal, catalyst regeneration, and reagent recycling into a closed-loop system. Acid-soluble Fe-residue and mineral impurities are eliminated from the solid graphite through HCl treatment, followed by hydrolytic distillation to regenerate Fe 2 O 3 and recover HCl for reuse. Coal-derived silica is removed with a KOH rinse, yielding low-ash graphite suitable for high-performance applications. The closed-loop catalytic graphitization, where the recovered Fe 2 O 3 and HCl are used in subsequent graphitization runs, produces graphite with a degree of graphitization exceeding 95%. The L a and L c crystallite sizes reach 65–78 nm and 44–48 nm, respectively, with BET surface areas of 4–10 m 2 /g and an ash content below 0.1 wt.%. Lithium-ion battery testing reveals that anodes fabricated with this graphite deliver an initial discharge capacity between 384.5 and 421.2 mAh/g, averaging 395.0 ± 19.1 mAh/g, along with initial coulombic efficiencies of 85.0–89.1%. After 100 discharge–charge cycles at 0.25C, reversible capacities remain between 358.8 and 369.7 mAh/g, while coulombic efficiency stays above 99.9%. The findings highlight that coal can serve as a viable precursor for high-quality graphite production under relatively mild conditions, avoiding the need for extreme temperatures or aggressive reagents such as hydrofluoric acid, commonly employed in conventional processes. This work demonstrates both technical feasibility and environmental benefits, emphasizing its potential to support large-scale, sustainable graphite production for applications such as lithium-ion batteries.

Catalytic graphitization

Integrate Power Conversion Unit with MAGNET to Enable Integrated Microreactor Heat Transfer System Testing

Idaho National Laboratory obtained a closed, Brayton-cycle, power conversion unit (PCU) from Sandia National Laboratories. This PCU began as a commercially available, 30 kWe, C30, gas turbine from Capstone. The C30 was modified to use heat from an electric heater in a closed-loop system pressurized with nitrogen or dry air. INL has modified the unit further to integrate it with MAGNET and use heat from a microreactor test article.

42 - ENGINEERING

Fusion Intelligence: A Paradigm for Merging Natural and Artificial Intelligence

Here, this article presents fusion intelligence (FI), a bio-inspired paradigm that synergistically integrates the intrinsic capabilities of intelligent biological organisms with the advanced potential of artificial intelligence (AI)-driven systems. FI harnesses the unique intelligence, sensing, actuation, and mobility attributes of living organisms, such as honeybees, blending these with the sophisticated data-driven problem-solving functionalities of AI. By bridging the gap between natural intelligence (NI) and AI, FI can transform how humans interact with and harness the capabilities of both natural and artificial systems. This article presents the model of FI and its application to solve practical problems, discusses the challenges and future directions of FI research, emphasizing a generalized approach to solve complex problems, where AI can observe/control NI in a closed-loop system. We demonstrate the potential for FI to enhance the performance of an agricultural IoT system via a simulated case study, which achieves 50% improvement in the efficacy of insect pollination (entomophily).

47 OTHER INSTRUMENTATION

Adsorption Studies of Dilute Krypton and Xenon from Nitrogen on SBMOF-1 and Activated Charcoal for Applications in Isotope Harvesting

Adsorptive partitioning of dilute krypton (Kr) and xenon (Xe) onto Stony Brook Metal–Organic Framework (SBMOF-1) and activated charcoal (AC) from carrier nitrogen was experimentally measured at temperatures ranging from 195 to 293 K. For this purpose, a closed-loop system for gas adsorption experiments was developed. From the Kr adsorption measurements, the adsorption equilibrium constant for Kr on SBMOF-1 was calculated, yielding a value for the enthalpy of adsorption of −19 ± 1 kJ·mol –1 . The partition coefficients were utilized to estimate the extraction rates of 76 Kr, 77 Kr, and 122 Xe isotopes during isotope harvesting at the Facility for Rare Isotope Beams (FRIB). We conclude that both materials showed promising results for the extraction of noble gases from FRIB effluents using temperature swing adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Isolated and H 2 -reduced Anderson clusters catalyse low-temperature hydrogenation of CO 2 to methanol

CO 2 hydrogenation, especially to methanol, is crucial to establishing sustainable closed-loop systems for carbon utilization. However, the difficulties of CO 2 activation at low temperatures and the ambiguity of structure–activity correlations are obstacles to reducing the energy consumption of the hydrogenation process. Here we report that molecularly defined Anderson PtMo 6 O 24 clusters, sited within a robust metal–organic framework, are catalytic for low-temperature CO 2 hydrogenation. The performance of the cluster showed no signs of decay in either its activity or methanol selectivity over 3,600 h at 180 °C. It also achieves a per-pass yield exceeding that of state-of-the-art heterogeneous catalysts under similar conditions. Combined in situ spectroscopy and density functional theory calculations demonstrated that CH 3 OH formation is dominated by the reverse water–gas shift and subsequent CO* hydrogenation pathway, while the HCOO* pathway may serve as a supplementary route. The well-defined cluster structure offers an ideal model for elucidating structure–activity correlations and opens exciting avenues for the rational design of high-activity, low-temperature catalysts for CO 2 hydrogenation.

heterogeneous catalysis

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING

PSH Assessment and Site Identification [Slides]

NLR's Pumped Storage Hydropower (PSH) geospatial and cost model algorithms are applied to the Chemehuevi Reservation to assess the potential for PSH within the reservation. The algorithm identifies both "open-loop" PSH opportunities formed by constructing a new reservoir within the reservation paired with bordering Lake Havasu and "closed-loop" systems formed by two new reservoirs within the reservation. Options range from 28 to 538 MW of electrical generation power at maximum generation and 10 hours of storage. CAPEX is estimates as 4422 2022 $\$$/kW of generating power, which is meaningfully higher than the lowest cost systems identified in NLR's national scale assessments. Further economic analysis is needed to fully evaluate whether this would be an attractive option to meet the Chemehuevi Reservation's goals.

25 ENERGY STORAGE