Search NASA⌕ Search

SEARCH · Search NASA

Results for “CO2 monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Devising a framework to Couple Electromagnetic Geophysical Measurements with Reservoir Simulations to Monitor CO2 Plume Movement

Monitoring CO2 plume movement and extent is critical to any CO2 utilization and storage (CCUS) project but can present significant challenges. Downhole measurements (such as cross-well seismic) can give the resolution needed to track the CO2 plume. That resolution comes at a significant expense in equipment and lost production time, and the resolution is only in the vicinity of that well. Surface seismic is less expensive but has decreasing resolution with depth and may not be sensitive to changes in the CO2 plume. Conversely, electrical conductivity has been shown to be correlated with changes in phase saturation associated with CCUS operations. A novel approach for subsurface monitoring that can be applied with minimal expense and operation disruption is charged wellbore casing controlled-source electromagnetics (CWC-CSEM). This technique injects electrical current into two legacy wells. Surface measurements of the induced electric and magnetic fields are obtained with distributed data loggers. Time-lapse measurements are sensitive to changes in CO2 plume movement, but inversion requires the application of prior knowledge from prior characterization efforts. We propose a methodology where simulations are used to inform CWC-CSEM inversion while simultaneously being validated. As such, uncertainty is reduced, and more robust flow models can be devised. A three-year study is underway at the Bell Creek Field in southeast Montana (DOE-NETL Project DE-FE0028320) to evaluate the effectiveness of CWC-CSEM on an active CO2-EOR operation. Determining the relationship between electrical resistivity and phase saturations, and coupling that to a reservoir model is the thrust of this project. Initially, the relative permeability/capillary pressure relationship and the compositional oil model were identified as model parameters with high uncertainty. To elucidate the impact of these uncertain parameters, simulations were run for ten years with a single five-spot pattern. Final water saturation distributions were converted into resistivity using Archie’s Law and available fluid sampling data to provide an exploration of the time lapse electromagnetic anomaly which can be anticipated using CWC-CSEM methods. This technique has promise as an inexpensive and accurate way to monitor CO2 injection in a CCUS site.

Moodie, Nathan↗

The feasibility of MT tipper data to monitor CO2 storage sites

Monitoring carbon storage sites using geophysical techniques is a critical component to the success and safety of storage programs. Currently, the primary methods of monitoring such sites are seismic and, to a much lesser extent, electromagnetics using active sources. The cost of such methods, especially seismic, can be prohibitively expensive. Natural source lectromagnetics, or magnetotellurics (MT), represents a low-cost, and underutilized method with the potential to aid CO2 monitoring efforts. Specifically, the tipper of MT data gives insight to the dimensionality of the subsurface and is able to detect the expansion front of a CO2 plume in a saline reservoir. We analyze the feasibility of using the tipper to monitor two shallow CO2 plumes and conclude that the tipper may be a suitable method for long-term monitoring.<br>

Kohnke, Colton↗

Shallow Marine High-Resolution 3D Seismics for Above-Zone CO2 Monitoring: A Case Study in Offshore Japan

Shallow marine high-resolution 3D (HR3D) seismic utilizes a novel seismic acquisition technology for imaging fine geological features not revealed by conventional 3D surveys. HR3D technology has been previously used for shallow subsurface studies, however is rarely implemented for monitoring injected fluids, and has not previously been used to monitor an active CO2 storage project. In this study, we for the first time demonstrate the acquisition, processing and initial interpretation of a HR3D seismic survey in Tomakomai, offshore Japan, where a large-scale CO2 storage project is being undertaken. As a seismic monitoring tool, the HR3D survey images the geologic overburden (< 1000 ms), aiming to detect potential CO2 leakage pathways above the injection reservoir. The HR3D acquisition system comprises a 210 in3 GI air gun and 4 streamers that are 25 m in length with 10 m inline separation. Each streamer has 8 channels with a 3.125 m group interval, yielding a very small final bin size of 3 x 3 m. The short offset and low-fold coverage of the HR3D data creates new challenges in seismic data processing, which demands a different data processing workflow tailored to the HR3D acquisition. We present a data processing workflow involving multiple software processing packages, which tackled high-resolution related static issues and significantly reduced various noise elements. Dip-steering and structural filtering were employed on the stacked volume to further enhance the lateral coherence and to remove random noise and suppress acquisition footprints. The final volume shows flat and coherent above-zone stratigraphy, suggesting a good seal quality above the CO2 reservoir. The successful implementation of HR3D acquisition and the customized processing workflow verify the feasibility of HR3D seismics for the above- zone monitoring of offshore CO2 injection and storage projects.

Feng, Ye Erickson↗

Analysis of land-based CSEM data for CO2 monitoring at Bell Creek, MT

Monitoring subsurface fluid migration is critical to any CO2 injection operation like enhanced oil recovery or carbon storage. The controlled-source electromagnetic (CSEM) method provides a promising low-cost, non-invasive alternative to conventional monitoring methods. To investigate the use of CSEM for monitoring CO2 injection, we are conducting a time-lapse charged well casing CSEM survey at the Bell Creek oil field. There, CO2 is injected into the reservoir for enhanced oil recovery, which also results in incidental carbon storage. From October 2017 to October 2018 we completed three field campaigns, and we plan to complete one more in July 2019. We have analyzed the signal strength and variance of the time-lapse CSEM data. Difference data signal strength well exceeds the standard deviation of the data, and it agrees with estimates of expected signal strength derived from numerical modeling. This analysis indicates that our survey can detect the change in conductivity within the reservoir due to fluid movement.

time-lapse, land CSEM, monitoring, processing↗

Pulsed Neutron Capture for monitoring CO2 Storage with Enhanced Oil Recovery in Northern Michigan

Pulsed neutron capture (PNC) logging has been used as part of the Midwest Regional Carbon Sequestration Partnership (MRCSP) monitoring of CO2 injection and storage during assessment of enhanced oil recovery (EOR) in several northern Niagaran trend reefs in Michigan. A total of four reefs were selected for these studies to monitor CO2 migration and to test the viability and effectiveness of the PNC technology on reefs in various stages (depleted, active and new reefs) of CO2-EOR activities.

Bagley↗

AN INTEGRATED CO2 MONITORING SYSTEM: FIRST INVERSION RESULT

History-matching through inverse modeling of pressure monitoring data delivers a first-order approximation of a reservoir model at an industrial-scale CO2 injection site. The reservoir model forms the backbone of an integrated monitoring system (IMS) for subsurface CO2 storage, which will ultimately encompass the integrated analysis of pressure-temperature and geophysical seismic monitoring data. First inversion results confirm the existence of a hydraulically isolating thin layer in the lower injection interval, known as mudstone baffle.

99 GENERAL AND MISCELLANEOUS↗

Advanced Technologies for Monitoring CO2 Saturation and Pore Pressure in Geologic Formations: Linking the Chemical and Physical Effects to Elastic and Transport Properties

Ultrasonic P- and S-wave velocities were measured over a range of confining pressures while injecting CO2 and brine into the samples. Pore fluid pressure was also varied and monitored together with porosity during injection. Effective medium models were developed to understand the mechanisms and impact of observed changes and to provide the means for implementation of the interpretation methodologies in the field. Ultrasonic P- and S-wave velocities in carbonate rocks show as much as 20-50% decrease after injection of the reactive CO2-brine mixture; the changes were caused by permanent changes to the rock elastic frame associated with dissolution of mineral. Velocity decreases were observed under both dry and fluid-saturated conditions, and the amount of change was correlated with the initial pore fabrics. Scanning Electron Microscope images of carbonate rock microstructures were taken before and after injection of CO2-rich water. The images reveal enlargement of the pores, dissolution of micrite (micron-scale calcite crystals), and pitting of grain surfaces caused by the fluid- solid chemical reactivity. The magnitude of the changes correlates with the rock microtexture – tight, high surface area samples showed the largest changes in permeability and smallest changes in porosity and elastic stiffness compared to those in rocks with looser texture and larger intergranular pore space. Changes to the pore space also occurred from flow of fine particles with the injected fluid. Carbonates with grain-coating materials, such as residual oil, experienced very little permanent change during injection. In the tight micrite/spar cement component, dissolution is controlled by diffusion: the mass transfer of products and reactants is thus slow and the fluid is expected to be close to thermodynamical equilibrium with the calcite, leading to very little dissolution, or even precipitation. In the microporous rounded micrite and macropores, dissolution is controlled by advection: because of an efficient mass transfer of reactants and products, the fluid remains acidic, far from thermodynamical equilibrium and the dissolution of calcite is important. These conclusions are consistent with the lab observations. Sandstones from the Tuscaloosa formation in Mississippi were also subjected to injection under representative in situ stress and pore pressure conditions. Again, both P- and S-wave velocities decreased with injection. Time-lapse SEM images indicated permanent changes induced in the sandstone microstructure by chamosite dissolution upon injection of CO2-rich brine. After injection, the sandstone showed an overall cleaner microstructure. Two main changes are involved: (a) clay dissolution between grains and at the grain contact and (b) rearrangement of grains due to compaction under pressure Theoretical and empirical models were developed to quantify the elastic changes associated with injection. Permanent changes to the rock frame resulted in seismic velocity-porosity trends that mimic natural diagenetic changes. Hence, when laboratory measurments are not available for a candidate site, these trends can be estimated from depth trends in well logs. New theoretical equations were developed to predict the changes in elastic moduli upon substitution of pore-filling material. These equations reduce to Gassmann’s equations for the case of constant frame properties, low seismic frequencies, and fluid changes in the pore space. The new models also predict the change dissolution or precipitation of mineral, which cannot be described with the conventional Gassmann theory.

Mavko, G.↗

Model Selection for Monitoring CO2 Plume during Sequestration

The model selection method developed as part of this project mainly includes four steps: (1) assessing the connectivity/dynamic characteristics of a large prior ensemble of models, (2) model clustering using multidimensional scaling coupled with k-mean clustering, (3) model selection using the Bayes' rule in the reduced model space, (4) model expansion using iterative resampling of the posterior models. The fourth step expresses one of the advantages of the method: it provides a built-in means of quantifying the uncertainty in predictions made with the selected models. In our application to plume monitoring, by expanding the posterior space of models, the final ensemble of representations of geological model can be used to assess the uncertainty in predicting the future displacement of the CO2 plume. The software implementation of this approach is attached here.

Source record↗

Time-lapse VSP data processing for monitoring CO2 injection

As a part of the effort of the Southwest Regional Partnership on Carbon Sequestration supported by U.S. Department of Energy and managed by the National Energy Technology Laboratory, two sets of time-lapse VSPs were acquired and processed in oil fields undergoing CO{sub 2} injection. One set of VSPs was acquired at the Aneth oil field in Utah, the other set at the Scurry Area Canyon Reef Operators Committee (SACROC) field in West Texas. One baseline and two repeat VSP surveys were conducted from 2007 to 2009 at the Aneth oil field in Utah for monitoring CO{sub 2} injection. The aim of the time-lapse VSP surveys is to study the combined enhanced oil recovery (EOR) and CO{sub 2} sequestration in collaboration with Resolute Natural Resources, Inc. VSP data were acquired using a cemented geophone string with 60 levels at depth from 805 m to 1704 m, and CO{sub 2} is injected into a horizontal well nearby within the reservoir at depth approximately from 1730 m to 1780 m. For each VSP survey, the data were acquired for one zero-offset source location and seven offset source locations (Figure 1). The baseline VSP survey was conducted before the CO{sub 2} injection. More than ten thousand tons of CO{sub 2} was injected between each of the two repeat VSP surveys. There are three horizontal injection wells, all originating from the same vertical well. One is drilled towards Southeast, directly towards the monitoring well (Figure 2), and the other two towards Northwest, directly away from the monitoring well. The injection is into the top portion of the Desert Creek formation, just beneath the Gothic shale, which acts as the reservoir seal. The initial baseline acquisition was done in October 2007; subsequent time-lapse acquisitions were conducted in July 2008, and January 2009. The acquisition geometry is shown in Figure 1. Shot point 1 is the zero-offset source location, Shot points 2 to 8 are the seven offset VSPs, arranged in a quarter circle on the Northwest side of the monitoring well. The horizontal injection well is shown in green. The black lines in Figure 1 show the approximate reflection coverage al reservoir depth from the respective offset source locations. VSP source location 5 is in a direct line with the injection. The 60 geophone sondes were cemented into the monitor well just before the baseline VSP acquisition and consisted of 96 geophone channels, with 18 three-component geophones (at the bottom of the string) and 42 single vertical component phones above. For this study, only the vertical geophone data were used.

54 ENVIRONMENTAL SCIENCES↗

Modeling the resolution of inexpensive, novel non-seismic geophysical monitoring tools to monitor CO2 injection into coal beds

A sensitivity study of gravity and electromagnetic (EM) techniques, and amplitude vs. angle (AVA) analysis for CO{sub 2} movement in coal beds was based on the SECARB pilot test planned in the Black Warrior basin in Alabama. In the area of interest, coalbed methane is produced mainly from the Black Creek, Mary Lee, and Pratt coal zones at depths between 400 and 700 m and approximately 3 m thick on average. The permeability of coal in the Black Warrior basin decreases exponentially with depth as overburden stress increases. The permeability of the top layer is 100 mD, while the permeability of the deepest layer is around 1 mD. The pilot field test will include injecting a total of 1000 tons of CO{sub 2} into these three coal zones ({approx}300 tons to each zone). The density, sonic and resistivity well-logs from a deep disposal well a couple of miles from the pilot test site were used to create background (pre-injection) models. Our laboratory measurements of seismic velocity and electrical resistivity as a function of CO{sub 2} saturation on coal core samples were used to provide a link between the coalbed CO{sub 2} flow simulation models and the geophysical models. The sensitivity studies showed that while the response to the 300 tons of CO{sub 2} injected into a single layer wouldn't produce measurable surface response for either gravity or EM, the response due to an industrial-size injection would produce measurable surface signal for both techniques. Gravity inversion results illustrated that, provided we can collect high-quality gravity data in the field and we have some a priori information about the depth of the reservoir, we can recover the spatial location of CO{sub 2} plume correctly, although with the smoothing constraint of the inversion, the area was slightly overestimated, resulting in an underestimated value of density change. AVA analysis showed that by inverting seismic and EM data jointly, much better estimates of CO{sub 2} saturation can be obtained, especially in the third injection zone, where seismic AVA data fail to detect the high CO{sub 2} saturation. Analysis of spatial resolution and detectability limits show that gravity and EM measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

54 ENVIRONMENTAL SCIENCES↗

Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring

Abstract Carbon dioxide (CO 2 ) has been linked to many deleterious health effects, and it has also been used as a proxy for building occupancy measurements. These applications have created a need for low-cost and low-power CO 2 sensors that can be seamlessly incorporated into existing buildings. We report a resonant mass sensor coated with a solution-processable polymer blend of poly(ethylene oxide) (PEO) and poly(ethyleneimine) (PEI) for the detection of CO 2 across multiple use conditions. Controlling the polymer blend composition and nanostructure enabled better transport of the analyte gas into the sensing layer, which allowed for significantly enhanced CO 2 sensing relative to the state of the art. Moreover, the hydrophilic nature of PEO resulted in water uptake, which provided for higher sensing sensitivity at elevated humidity conditions. Therefore, this key integration of materials and resonant sensor platform could be a potential solution in the future for CO 2 monitoring in smart infrastructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗