Search NASA⌕ Search

SEARCH · Search NASA

Results for “CO2 purification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Performance of a Natural Gas Solid Oxide Fuel Cell System With and Without Carbon Capture

The fuel cell program at the United States Department of Energy (DOE) National Energy Technology Laboratory (NETL) is focused on the development of low-cost, highly efficient, and reliable fossil-fuel-based solid oxide fuel cell (SOFC) power systems that can generate environmentally-friendly electric power with at least 90 percent carbon capture. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale natural gas (NG)- and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being carried out at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale NG fuel cell (NGFC) systems with and without carbon dioxide (CO2) capture is presented. The NGFC system analyzed features an external auto-thermal reformer (ATR) feeding the fuel to the SOFC system consisting of planar anode-supported SOFC with separated anode and cathode off-gas streams. In systems with CO2 capture, an air separation unit (ASU) is used to provide the oxygen for the ATR and for the combustion of unutilized fuel in the SOFC anode exhaust along with a CO2 purification unit to provide a nearly pure CO2 stream suitable for transport for usage in enhanced oil recovery operations or for storage in underground saline formations. Remaining thermal energy in the exhaust gases is recovered in a bottoming steam Rankine cycle while supplying any process heat requirements. A reduced order model (ROM) developed at the Pacific Northwest National Laboratory (PNNL) is used to predict the SOFC performance. The ROM, while being computationally effective for system studies, provides other detailed information about the state of the stack, such as the internal temperature gradient, generally not available from simple performance models often used to represent the SOFC. Such additional information can be important in system optimization studies to preclude operation under off-design conditions that can adversely impact overall system reliability. The NGFC system performance was analyzed by varying salient system parameters, including the percent of internal (to the SOFC module) NG reformation—ranging from 0 to 100 percent—fuel utilization, and current density. The impact of advances in underlying SOFC technology on electrical performance was also explored.

solid oxide fuel cell (SOFC), natural gas fuel cel↗

Process Design and Techno-Economic Analysis of the Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Biomass

This work describes the process design and techno-economic analysis (TEA) of the modular SPOC power plant for biomass firing and coal-biomass co-firing. Two Rankine cycles were considered: a supercritical steam cycle (242 bar, 593°C, 593°C) with 550 MWe net output and a subcritical cycle (166 bar, 566°C, 566°C) with 200 MWe net output. For both cases, 95% carbon capture was modeled, and hybrid poplar biomass was chosen to generate carbon-negative power. In addition, the supercritical 500 MWe case included a 25% biomass co-firing (carbon neutral) case. For both cycles, a 100% Powder River Basin coal firing case was used for comparison purposes. In the SPOC process, oxygen is produced via a cryogenic air separation unit (ASU) and the heat generated from the compression of air is integrated into the steam cycle and utilized for boiler feed water pre-heating. Unique to the SPOC process, the boilers are pressurized and arranged in a series-parallel configuration, with minimized flue gas recirculation. The flue gas is cooled and scrubbed in the direct-contact cooler (DCC) column, and the moisture in the flue gas is condensed, leaving the bottom of the DCC at a sufficiently high temperature such that it can be used for boiler feed water pre-heating, improving plant thermal efficiency. Following drying and purification, CO2 in the flue gas is at the purity required for storage or utilization. The performance data were obtained from process modelling via Aspen Plus®. The stream data from Aspen Plus® were used as an input for the AACE Class 5 cost study. Ultimately, the capital costs, Levelized Cost of Electricity (LCOE), and cost of CO2 captured and avoided were obtained. The HHV efficiency of the carbon negative 550 MWe supercritical SPOC case (34.8%) was clearly above those reported by NETL for the BECCS baseline cases of supercritical pulverized coal with capture (B12B, 31.5%) and the 49% biomass co-firing case with capture (PA3, 29.2%). The HHV efficiency of the carbon-negative subcritical plant is also higher than the subcritical baseline PC plant with capture (case B11B.95) presented by NETL (32% vs 29.7%). The LCOE for the SPOC 100% biomass case was similar to the LCOE for the BECCS 49% biomass with carbon capture case ($147/MWh), and the SPOC carbon neutral case LCOE was lower ($110/MWh) than the cost for the NETL baseline SC coal firing case with 90% carbon capture ($114/MWh).

Magalhaes, Duarte↗

Simulated moving bed system for CO2 separation, and method of same

A system and method for separating and/or purification of CO2 gas from a CO2 feed stream is described. The system and method include a plurality of fixed sorbent beds, adsorption zones and desorption zones, where the sorbent beds are connected via valve and lines to create a simulated moving bed system, where the sorbent beds move from one adsorption position to another adsorption position, and then into one regeneration position to another regeneration position, and optionally back to an adsorption position. The system and method operate by concentration swing adsorption/desorption and by adsorptive/desorptive displacement.

Elliott, Jeannine Elizabeth↗

Catalytic Oxygen Reduction for Deep O 2 Removal from CO 2 Streams

Streams of CO 2 from various capture processes may contain several impurities of which O 2 is often overlooked as a problematic impurity. Because of its reactivity, the National Energy Technology Laboratory has recommended a stringent limit, less than 10 ppm, for the O 2 level in treated CO 2 products for safe transport, storage, and utilization. Here, in this study, a variety of catalytic oxygen reduction approaches using commercial automotive exhaust emission catalysts are evaluated for O 2 removal from CO 2 streams using different reducing agents, including H 2 , CO, CH 3 OH, and CH 4 . When the amount of reductant added into the feed is carefully controlled, H 2 , CO, or CH 3 OH can effectively remove O 2 from 1.5% to below 10 ppm with a single-reactor design (>99.93% removal efficiency), while simultaneously meeting the impurity limits for other species. With CH 4 as a reductant, it is challenging to simultaneously meet the the O 2 and CO specifications in a single-reactor design because CH 4 also reacts with CO 2 to produce high levels of CO in the stream (at several hundred ppm). A dual-reactor design is developed to enable the use of CH 4 , a readily available and low-cost reductant, for the purification of CO 2 streams to meet the specifications for O 2 and other impurities.

CO2 purification↗

Technoeconomic analysis and life cycle assessment of purification processes for captured CO 2 streams

Captured carbon dioxide (CO 2 ) streams contain impurities that must be removed to meet specifications for safe transport, storage, and utilization. Among these impurities, oxygen poses challenges due to its high reactivity and potential to cause corrosion, motivating stringent purity limits below 10 ppmv. Building on recent experimental demonstrations of catalytic oxygen removal using hydrogen (H 2 ), carbon monoxide (CO), methanol (CH 3 OH), and methane (CH 4 ) as reducing agents, this study presents a technoeconomic (TEA) and life cycle assessment (LCA) of these four catalytic purification pathways. Process flowsheets were developed and simulated in Aspen Plus for CO 2 streams representative of both low-temperature and high-temperature capture processes, with integrated heat recovery and energy optimization. Results showed that total purification costs were dominated by feedstock procurement and electricity consumption. Among the studied reducing agents, the CH 4 -assisted route achieved the lowest purification cost and highest CO 2 recovery. Sensitivity analyses showed that the H 2 route became competitive at H 2 prices below $\$$0.56/kg to $\$$0.84/kg, depending on the CO 2 feed temperature conditions. In conclusion, environmental impacts were primarily driven by indirect CO 2 emissions from raw material production and utility consumption.

CO2 pipeline specifications↗

Efficient Synthetic Natural Gas Production from Direct Air Capture Using Titania-Based Dual Function Materials

Converting atmospheric CO2 into methane offers a compelling pathway to store intermittent renewable electricity and enhance energy security using existing natural gas infrastructure. However, current CO2 utilization approaches remain energy- and capital-intensive, largely due to the need for separate capture, purification, and conversion steps. Integrating CO2 capture with catalytic methanation represents a transformative strategy for process intensification on both the unit operation and molecular levels. We report a series of Ru-Na/TiO2 dual function materials (DFMs) for a reactive carbon capture (RCC) process consisting of simulated direct air capture and subsequent CO2 methanation (DACM). Superior methane desorption purity was observed on TiO2-based DFMs (>94 %) relative to state-of-the-art Al2O3-supported DFMs (77 %). Modifying the process to begin CO2 adsorption immediately following the methanation stage, rather than beginning adsorption near ambient temperature, resulted in >97 % methane desorption purity, suitable for injection into the natural gas pipeline without additional CO2 separation steps.

organic↗

Comparing energy and water use of aqueous and gas-based metalworking fluids

Gas-based metalworking fluids (MWFs) have been proposed as alternative coolants and lubricants in machining operations to mitigate concerns surrounding water use and pollution, industrial hygiene, occupational health, and performance limitations associated with water-based (aqueous) MWFs that are ubiquitously used in the metals manufacturing industry. This study compares the primary energy and water use associated with the consumptive use, delivery, and disposal of aqueous MWFs with three gas-based MWFs in the literature-minimum quantity lubricant-in-compressed air (MQL), liquid/gaseous N-2, and liquid/supercritical CO2. The comparison accounts for reported differences in machining performance in peer-reviewed experimental studies across several machining processes and materials. The analysis shows that despite the reported improvement in tool life with N-2 and CO2-based MWFs, the electricity- and water-intensive separation and purification processes for N-2 and CO2 lead to their higher primary energy and water use per volume of material machined relative to water-based MWFs. Although MQL is found to have lower primary energy use, significant consumptive water use associated with the vegetable oil commonly used with this MWF leads to higher overall water use than aqueous MWF, which is operated in a recirculative system. Gas-based MWFs thus shift the water use upstream of the manufacturing plant. Primary energy and water use of gas-based MWFs could be reduced by focusing on achieving higher material removal rates and throughput compared to aqueous MWF instead of solely targeting improvements in tool life. Additionally, the consumptive use of CO2 and N-2 MWFs could be minimized by optimizing their flow rates and delivery to precisely meet the cooling and lubrication needs of specific machining processes instead of flooding the tool and workpiece with these gases. This article met the requirements for a gold-gold JIE data openness badge described at http://jie.click/badges.

cutting fluids↗

Carbon Capture from ArcelorMittal Hot Briquetted Iron Plant Using Air Liquide Cryocap™ FG Technology – FEED Study

The process of steel production is energy and carbon intensive with global average energy consumption of 5.5 MWh/tonne of steel and CO2 emission intensity of 1.83 tonne CO2/tonne of steel. The steel making process has inherent CO2 emissions from mineral conversion and is considered major contributors to the global carbon emissions. The steel industry is responsible for 8% of global carbon emissions. The main objective of this research project is to execute and complete a front-end engineering and design (FEED) study for a commercial-scale, carbon capture project that separates 95% of the total CO2 emissions at the ArcelorMittal’s Hot Briquetted Iron (HBI) plant in Portland, TX (Figure 1). The HBI is an ore-based metallic that is used as high-grade feedstock for high-quality steel via an Electric Arc Furnace (EAF) route. The HBI plant produces 2.0 million metric tonnes of high-quality HBI and emits approximately 1 million tonnes CO2/yr. The capture system is a Pressure Swing Adsorption (PSA) system assisted Cryocap™ FG technology (Figure 2). The captured CO2 will be pipeline grade and will be geologically stored in a facility within 10 miles of the CO2 source. The Host Site location in Corpus Christi, TX, is near hydrocarbon processing facilities and near Environmental Justice (EJ) and Qualified Opportunity Zone (QOZ) communities. Due to the location of the Host Site, the retrofit project offers the ability to demonstrate how a workforce focused on the fossil energy sector can be redirected to the clean- energy sector. The Air Liquide Cryocap™ capture technology is a proven technology and has been extensively examined for large industrial applications. It has been shown to be applicable to a variety of industrial applications including the steel industry. Cryocap™ FG (specific setup for Flue Gas application) consists of a Pressure Swing Adsorption (PSA) unit coupled with a Cryogenic System. The PSA pre-concentrates the CO2 from the flue gas, while the cryogenic unit enables the CO2 purity to be increased to the desired level. The scope of this study incorporates completing FEED study of the CO2 capture system which includes point-source CO2 capture and balance-of-plant; Business Case Analysis (BCA) outlining the current and projected volumes of the steel plant’s point sources of CO2 and the potential utilization of tax credits, including its projected revenue and duration; Life Cycle Analysis (LCA); Environmental Justice Analysis; Economic Revitalization and Job Creation Outcomes Analysis; and Workforce Readiness Plan. The plant design work was divided into two components: Inside Battery Limits (ISBL) and Outside Battery Limits (OSBL). The ISBL focuses on the capture system, while the OSBL focuses on the utility feeds and ducting from the plant to the capture system. Various design and engineering deliverables will be developed to define commodity quantities, equipment specifications, and labour effort required to execute the project. These FEED study deliverables will be prepared with the intent to develop an overall project capital cost estimate consistent with an AACE Class 3 estimate. The modular approach for the Cryocap™ FG that is being designed for this study integrates compression, PSA, and cryogenic “bricks” to achieve the desired CO2 capture rates. This carbon capture system integrates easily with the existing plant, thus reducing project costs and risks. It is also capable of managing impurities such as nitrogen oxides (NOx), sulfur oxides (SOx), mercury, hydrocarbons, and particulate matter. The capture system has a smaller footprint than amine-based systems. The two-step process uses PSA to preconcentrate the CO2 in the feedstream and then uses the cryogenic portion to purify and compress the resulting high purity CO2 product. This combination of purification and compression (i.e., process intensification) significantly reduces the CAPEX associated with use of a separate compressor commonly utilized for amine solvent-based systems. Successful completion of the FEED study will provide DOE with a detailed understanding of the costs for scaling up this proven capture technology for commercial applications at industrial facilities.

42 ENGINEERING↗

Highly Efficient Regeneration Module for Carbon Capture Systems in NGCC Applications

The objective of this project is to design, fabricate, and test a highly efficient regeneration module capable of providing an ultra-lean absorption solution that is required for capturing CO 2 from dilute sources at 95% or better efficiency. By integrating this advanced regenerator module with SRI International’s Mixed Salt Process (MSP) absorption modules, SRI expects to demonstrate significant progress toward a reduction in cost of capture versus the DOE reference natural gas combined cycle (NGCC) plant with carbon capture. SRI designed, built, and tested an advanced stripper to enhance the performance of SRI’s MSP for CO 2 capture – a transformational ammonia-based solvent technology – for natural gas (NG) power sources. The testing of the advanced stripper for MSP was conducted at an SRI site using a simulated flue gas stream equivalent to about 10 kWe. The research work included modeling of the advanced stripper and integrating it with the MSP absorbers; studying the strategies for producing very highly alkaline lean solvent with minimized emissions; operating the stripper with advanced heat integration to improve process efficiencies; and collecting critically important data for a detailed techno-economic analysis (TEA). The project tasks were designed to address concerns relating to scale-up and integration of the technology to NG power plants—more specifically, to maximize the carbon capture efficiency achievable with MSP and identify pathways to achieve higher capture efficiencies and ultimately zero net carbon emissions. SRI teamed up with a process modeling company (OLI Systems), a process and chemical engineering company (Trimeric Corporation), and a cost-sharing commercial partner (Baker-Hughes – a leading multinational company that designs, manufactures, and services transformative energy technologies) to execute the project. The research findings will accelerate the MSP development and pave the way for the technology to reach the DOE’s goal, and ultimately commercialization of the MSP technology for low-cost CO 2 capture from NGCC flue gas and other dilute CO 2 sources.

03 NATURAL GAS↗

Scalable Polymeric Few-Nanometer Organosilica Membranes with Hydrothermal Stability for Selective Hydrogen Separation

Nanoporous silica membranes exhibit excellent H 2 /CO 2 separation properties for sustainable H 2 production and CO 2 capture but are prepared via complicated thermal processes above 400 °C, which prevent their scalable production at a low cost. Here, we demonstrate the rapid fabrication (within 2 min) of ultrathin silica-like membranes (~3 nm) via an oxygen plasma treatment of polydimethylsiloxane-based thin-film composite membranes at 20 °C. The resulting organosilica membranes unexpectedly exhibit H2 permeance of 280-930 GPU (1 GPU = 3.347 x 10 -10 mol m -2 s -1 Pa -1 ) and H2/CO2 selectivity of 93-32 at 200 °C, far surpassing state-of-the-art membranes and Robeson’s upper bound for H 2 /CO 2 separation. When challenged with a 3 d simulated syngas test containing water vapor at 200 °C and a 340 d stability test, the membrane shows durable separation performance and excellent hydrothermal stability. The robust H 2 /CO 2 separation properties coupled with excellent scalability demonstrate the great potential of these organosilica membranes for economic H 2 production with minimal carbon emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous weakly coordinating anionic frameworks (Final Technical Report)

Under this award, we synthesized and characterized new weakly coordinating, anionic covalent organic frameworks. The motivation was to expand the class of covalent organic frameworks though the introduction of the first weakly coordinating anionic ones. The significance of the weakly coordinating anionic character of these frameworks is associated with the character of the counter (metal) cations in their pores. Those counter-cations, due to the inability to effectively coordinate to the pore walls, have a “naked”, and thus highly electrophilic, Lewis acidic character. Such properties are expected to translate to a number of interesting physical properties that can be potentially used for a range of energy-relevant applications. One of these applications is gas adsorption, separation, and storage. The electrophilic, Lewis acidic character of the counter-cations are expected to strongly bind to gas molecules entering the pores leading to higher gas sorption capacities. Other applications include heterogeneous catalysis, ion exchange, and solid state ion conduction. Within the project we explored a range of chemical blocks, and tested synthesis conditions to polymerize these building blocks to form the target materials. In particular, we focused on materials with group 15 elements like phosphorus in the oxidation state +5 and the coordination number 6, that have a formal -1 charge. The synthesis of such materials is challenging because its success depends on the absence of residual monomeric and oligomeric side-products in the pores, and the absence of significant framework interpenetration. Crystalline forms of these materials require sufficient reversibility of the polymerization reaction (which is difficult to achieve because group 15 elements like P tend to make strong covalent bonds with neighbored elements), as well as suitable polymerization rates that prevent the formation of kinetically controlled products. We had success with the preparation of anionic porous organic frameworks with anionic building blocks containing P(V)O6 octahedra synthesized through Yamamoto coupling reactions. These materials are non-crystalline because of the irreversible nature of the Yamamoto coupling reaction, but show porosity. The porosity and surface area can be significantly increased by co-reaction with electrostatically neutral co-reactants. Very high porosity and surface areas can be achieved when the materials are washed with hydrochloric acid. This method is commonly used to free products from Yamamoto coupling reactions from by-products. Indeed, this method removed by products from the pores of our materials, however it also led to the hydrolysis of the PO6 octahedra to form pending phosphonic acid groups (-PO3H)-groups in the frameworks (PA-POFs) which was actually not desired. Nonetheless, these materials showed high CO2 sorption capacities. In addition, they show extremely high (actually record) sorption capacities for the removal of a range of common micropollutants such as bisphenol A (BPA) and 4-nitrophenol in water. BPA is a wide-spread organic pollutant and a known endocrine disruptor. The maximum adsorption capacity of BPA at equilibrium is found to be as high as 3,366 mg g-1 by Langmuir adsorption model, which is more than 10 times greater than peer materials. The polymer also rapidly removes various other organic micropollutants with more than 90% removal efficiencies. In addition, the PA-POF material can be regenerated at least five times by mild washing using methanol without significant loss in removal efficiency. This is significant advantage over commonly used activated carbon materials (that are in Brita water faucet filters, for example). Comparison studies showed that only materials with the phosphonate groups show extreme sorption although the number of PA group is actually small according to solid state NMR and EDX data. More research would be needed to investigate why this is (a possibility is that the phosphonate groups have a multiplying effect in which a PA-induced initial adsorption leads to the adsorption of much more adsorbate). The extreme sorption capabilities can also be visually seen when colored adsorbates such as 4-nitrophenol are used, as the adsorption of the nitrobenzene leads to the decoloration of the solution. We have produced three short videos that illustrate the sorption capabilities compared to two peer materials (activated carbon from dismantled Brita water filters, and a electrostatically neutral, chemically related, porous organic polymer, respectively).

36 MATERIALS SCIENCE↗

Atomically Fine-Tuning Organic–Inorganic Carbon Molecular Sieve Membranes for Hydrogen Production

Polymeric membranes with great processability are attractive for the H 2 /CO 2 separation required for hydrogen production from renewable biomass with carbon capture for utilization and sequestration. However, it remains elusive to engineer polymer architectures to obtain desired sub-3.3 Å ultramicropores to efficiently sieve H 2 from CO 2 . Herein, we demonstrate a scalable way of carbonizing polybenzimidazole (PBI) at low temperatures, followed by vapor phase infiltration (VPI) to atomically narrow ultramicropores throughout the films, forming hybrid organic–inorganic carbon molecular sieves (CMSs). One VPI cycle (100 s) for the PBI carbonized at 500 °C remarkably increases H 2 /CO 2 selectivity from 9.6 to 83 at 100 °C, surpassing Robeson’s upper bound. The CMS demonstrates a stable H 2 /CO 2 separation performance when challenged with simulated syngas streams and can be fabricated into thin-film composite membranes, outperforming state-of-the-art membranes. Finally, the scalable approach can be ubiquitous to molecularly fine-tune ultramicropores of leading polymeric membranes to further improve their size-sieving ability and thus separation efficiency.

36 MATERIALS SCIENCE↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Transformational Sorbent-Based Process for a Substantial Reduction in the Cost of CO2 Capture

Adsorption processes have the potential to significantly reduce the CO2 capture cost from power plants and industrial flue gases. InnoSepra has developed several sorbent-based technologies to obtain very high CO2 recovery and high purity CO2 while meeting the EOR/sequestration product specifications. A first-generation process was shown to achieve CO2 recoveries greater than 94% at CO2 purities in the range of 98.5-99.5%. The absolute heat energy required for the process was not only 40% lower than MEA but also was needed at a much lower temperature. This work will present the performance of the second-generation InnoSepra process which is based on a breakthrough sorbent regeneration method. This process has a projected 45% lower capital cost compared to MEA, less than 16% loss in plant output for CO2 capture and compression, and a CO2 capture cost at least 55% lower than MEA. Lab scale testing and the process simulations indicate a CO2 capture performance similar to or better than the first-generation process. Pilot scale drying and breakthrough tests were carried out at the Technology Centre Mongstad (TCM), Norway, and lab-scale cyclic tests were carried out at InnoSepra to confirm the process improvement. During these tests, InnoSepra’s flue gas purification technology was also tested at TCM. It can provide a low-cost option for the removal of NO2 and SOX to sub-ppm levels as well as a significant reduction in aerosol emissions.

08 HYDROGEN↗

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗

Polymeric Membranes for H2S and CO2 Removal from Natural Gas for Hydrogen Production: A Review

Natural gas, an important source of hydrogen, is expected to be crucial in the transition to a hydrogen-based economy. The landscape of the gas processing industry is set to change in the near future with the development of highly acidic sour gas wells. Natural gas purification constitutes a major share of the gas separation membrane market, and the shift to low-quality sour gas wells has been mirrored in the trends of membrane material research. Purification also constitutes the major portion of the cost of natural gas, posing implications for the cost of hydrogen production. This review provides an update on the current state of research regarding polymeric membranes for H2S removal, along with CO2 separation, from natural gas that is used for hydrogen production via steam methane reforming. The challenges of adapting polymeric membranes to ternary H2S/CO2/CH4 separations are discussed in detail. Key polymeric materials are highlighted, and the prospects for their application in H2S removal from natural gas are evaluated. Finally, the growing interest in H2 production from H2S is discussed. Advances in the membrane industry and the emergence of new membrane materials may significantly improve the commercial viability of such processes.

Rao, Shraavya↗

Catalytic Reduction of Residual Oxygen for the Purification of Carbon Dioxide Streams from Pressurized Oxy-Combustors

Pressurized oxy-combustion (OC) is regarded as an energy-efficient alternative to atmospheric OC. To utilize the captured carbon dioxide (CO2) from pressurized OC for enhanced oil recovery or carbon storage in geological formations, the CO2 product stream must meet the required purity specifications. One major impurity in OC flue gases is residual O2 (e.g., 3 vol%). In this study, a catalytic approach has been investigated to remove the residual O2 through a reduction reaction with injected methane (CH4) in a reverse-flow fixed-bed (RFFB) reactor. The performance was tested for a supported copper (Cu)-based catalyst synthesized by incipient wetness impregnation and a cobalt-manganese (CoMn) oxide catalyst synthesized by a coprecipitation method. A commercial Cu-based catalyst was also studied as the reference. Experimental results revealed that under the reverse-flow operation, the temperature profiles in the reactor were symmetrical on both sides of the catalyst zone and were more homogenous than those under the conventional one-direction-flow operation. Among the tested catalysts, the CoMn catalyst was the most reactive for promoting the reduction of O2 with CH4, able to attain >95% O2 removal at 475 °C and a gas hourly space velocity (GHSV) of 18,000 h-1 with a feed gas containing 3 vol% O2. Under all experiments, the concentrations of carbon monoxide (CO) were lower than 30 ppmv in the effluent gas streams. The reaction between O2 and CH4 could be depicted by using the Mars–van Krevelen redox mechanism based on a two-step reduction–oxidation reaction pathway.

36 MATERIALS SCIENCE↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗