Search NASA⌕ Search

SEARCH · Search NASA

Results for “COALESCENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Review on the Coalescence of Confined Drops with a Focus on Scaling Laws for the Growth of the Liquid Bridge

The surface–tension-driven coalescence of drops has been extensively studied because of the omnipresence of the phenomenon and its significance in various natural and engineering systems. When two drops come into contact, a liquid bridge is formed between them and then grows in its lateral dimensions. As a result, the two drops merge to become a bigger drop. The growth dynamics of the bridge are governed by a balance between the driving force and the viscous and inertial resistances of involved liquids, and it is usually represented by power–law scaling relations on the temporal evolution of the bridge dimension. Such scaling laws have been well-characterized for the coalescence of unconfined or freely suspended drops. However, drops are often confined by solid or liquid surfaces and thus are a different shape from spheres, which affects their coalescence dynamics. As such, the coalescence of confined drops poses more complicated interfacial fluid dynamics challenges compared to that of unconfined drops. Although there have been several studies on the coalescence of confined drops, they have not been systematically reviewed in terms of the properties and geometry of the confining surface. Thus, we aim to review the current literature on the coalescence of confined drops in three categories: drop coalescence on a solid surface, drop coalescence on a deformable surface, and drop coalescence between two parallel surfaces with a small gap (i.e., Hele-Shaw cell), with a focus on power–law scaling relations, and to suggest challenges and outlooks for future research on the phenomena.

Sangjin Ryu↗

A zero-gravity demonstration of the collision and coalescence of water droplets

The mechanics of the collision and coalescence of liquid droplets is one of the main research areas in the fields of nuclear physics, astrophysics, meteorology and fluid mechanics. The crew members on the Skylab 3 and 4 missions were requested to perform demonstrations of the collision and coalescence of water droplets under the low gravity environment at orbital altitude. In Skylab 4 two water droplets with equal volumes, 30 cu cm each, were used. A dark colored droplet (contaminated with grape drink) moving with a velocity of 3.14 cm/sec collided with a stationary pink colored droplet (contaminated with strawberry drink) and coalescence occurred. Theoretical models are proposed to study the various stages of the collision-coalescence processes. Special considerations are concentrated in the investigation of the bounce-coalescence and coalescence-instability processes. The surface tension of the coalesced droplets was calculated to be 52 dynes/cm in perfect agreement with laboratory measurements made after the flight using a reproduction of the liquids.

Hung, R. J.↗

Drop coalescence studies

The objective of this experimental study is to understand the detailed mechanics of the coalescence of liquid drops. The experiments are being conducted in an immiscible acoustic levitator with degassed water as the host medium. Typically, a quasineutrally buoyant drop of silicon oil mixed with bromobenzene is levitated close to the velocity node of the levitator. A second drop of the same liquid is introduced, and as it slowly seeks levitation position, the drops coalesce. Coalescence is delayed until the host film between drops is completely drained. Following coalescence, the excess surface energy in the coalesced drop is dissipated through shape oscillations. The final events of film rupture followed by drop coalescence are rapid and are photographically studied with high-speed video (1000 fps). The laser-induced fluorescence technique is used to visualize the dynamics of host film drainage. The details of the coalescence mechanics are presented.

Anikumar, A. V.↗

Merging neutron stars. 1. Initial results for coalescence of noncorotating systems

We present three-dimensional Newtonian simulations of the coalescence of two neutron stars, using a smoothed particle hydrodynamics (SPH) code. We begin the simulations with the two stars in a hard, circular binary, and have them spiral together as angular momentum is lost through gravitational radiation at the rate predicted by modeling the system as two point masses. We model the neutron stars as hard polytropes (gamma = 2.4) of equal mass, and investigate the effect of the initial spin of the two stars on the coalescence. The process of coalescence, from initial contact to the formation of an axially symmetric object, takes only a few orbital periods. Some of the material from the two neutron stars is shed, forming a thick disk around the central, coalesced object. The mass of this disk is dependent on the initial neutron star spins; higher spin rates result in greater mass loss and thus more massive disks. For spin rates that are most likely to be applicable to real systems, the central coalesced object has a mass of 2.4 solar mass, which is tantalizingly close to the maximum mass allowed by any neutron star equation of state for an object that is supported in part by rotation. Using a realistic nuclear equation of state, we estimate the temperature of the material after the coalescence. We find that the central object is at a temperature of approximately 10 MeV, while the disk is heated by shocks to a temperature of 2 to 4 MeV.

Davies, M. B.↗

An analysis of shock coalescence including three-dimensional effects with application to sonic boom extrapolation

A method for analyzing shock coalescence which includes three dimensional effects was developed. The method is based on an extension of the axisymmetric solution, with asymmetric effects introduced through an additional set of governing equations, derived by taking the second circumferential derivative of the standard shock equations in the plane of symmetry. The coalescence method is consistent with and has been combined with a nonlinear sonic boom extrapolation program which is based on the method of characteristics. The extrapolation program, is able to extrapolate pressure signatures which include embedded shocks from an initial data line in the plane of symmetry at approximately one body length from the axis of the aircraft to the ground. The axisymmetric shock coalescence solution, the asymmetric shock coalescence solution, the method of incorporating these solutions into the extrapolation program, and the methods used to determine spatial derivatives needed in the coalescence solution are described. Results of the method are shown for a body of revolution at a small, positive angle of attack.

Darden, C. M.↗

Upper limits for gravitational radiation from supermassive coalescing binaries

We report a search for waves from supermassive coalescing binaries using a 10.5 day Pioneer 10 data set taken in 1988. Depending on the time to coalescence, the initial frequency of the wave, and the length of the observing interval, a coalescing binary waveform appears in the tracking record either as a sinusoid, a 'chirp', or as a more complicated signal. We searched our data for coalescing binary waveforms in all three regimes. We successfully detected a (fortuitous) 'chirp' signal caused by the varying spin rate of the spacecraft; this nicely served as a calibration of the data quality and as a test of our analysis procedures on real data. We did not detect any signals of astronomical origin in the millihertz band to an upper limit of about 7 x 10 exp -15 (rms amplitude). This is the first time spacecraft Doppler data have been analyzed for coalescing binary waveforms, and the upper limits reported here are the best to date for any waveform in the millihertz band.

Anderson, J. D.↗

Coalescence of two current loops with a kink instability simulated by a three-dimensional electromagnetic particle code

We have studied the dynamics of a coalescence of current loops using three-dimensional electromagnetic (EM) particle simulation code. Our focus is the investigation of such kinetic processes as energy trasnfer, heating particles, and electromagnetic emissions associated with a current loop coalescence which cannot be studied by MHD simulations. First, the two loops undergo a pinching oscillation due to a pressure imbalance between the inside and outside of the current loop. During the pinching oscillation, a kinetic kink instability is excited and electrons in the loops are heated perpendicularly to an ambient magnetic field. Next, the two current loops collide and coalesce, while at the same time a helical structure grows further. Subsequently, the perturbed current, which is due to these helically bunched electrons, can drive a whistler instability. It should be noted in this case that the whistler wave is excited by the kinetic kink instability and not a beam instability. After the coalescence of two helical loops, tilting motions can be observed in the direction of left-hand rotation, and the helical structure will relax resulting in strong plasma heating mostly in the direction perpendicular to the ambient magnetic field. It is also shown that high-frequency electromagnetic waves can be emitted from the region where the two loops coalesce and propagate strongly in the direction of the electron drift velocity. These processes may be important in understanding heating mechansims for coronal loops as well as radio wave emission mechanisms from active regions of solar plasmas.

Nishikawa, K.-I.↗

Viscosity Measurement of Highly Viscous Liquids Using Drop Coalescence in Low Gravity

The method of drop coalescence is being investigated for use as a method for determining the viscosity of highly viscous undercooled liquids. Low gravity environment is necessary in this case to minimize the undesirable effects of body forces and liquid motion in levitated drops. Also, the low gravity environment will allow for investigating large liquid volumes which can lead to much higher accuracy for the viscosity calculations than possible under 1 - g conditions. The drop coalescence method is preferred over the drop oscillation technique since the latter method can only be applied for liquids with vanishingly small viscosities. The technique developed relies on both the highly accurate solution of the Navier-Stokes equations as well as on data from experiments conducted in near zero gravity environment. In the analytical aspect of the method two liquid volumes are brought into contact which will coalesce under the action of surface tension alone. The free surface geometry development as well as its velocity during coalescence which are obtained from numerical computations are compared with an analogous experimental model. The viscosity in the numerical computations is then adjusted to bring into agreement of the experimental results with the calculations. The true liquid viscosity is the one which brings the experiment closest to the calculations. Results are presented for method validation experiments performed recently on board the NASA/KC-135 aircraft. The numerical solution for this validation case was produced using the Boundary Element Method. In these tests the viscosity of a highly viscous liquid, in this case glycerine at room temperature, was determined to high degree of accuracy using the liquid coalescence method. These experiments gave very encouraging results which will be discussed together with plans for implementing the method in a shuttle flight experiment.

Antar, Basil N.↗

Viscosity Measurement Using Drop Coalescence in Microgravity

We present in here validation studies of a new method for application in microgravity environment which measures the viscosity of highly viscous undercooled liquids using drop coalescence. The method has the advantage of avoiding heterogeneous nucleation at container walls caused by crystallization of undercooled liquids during processing. Homogeneous nucleation can also be avoided due to the rapidity of the measurement using this method. The technique relies on measurements from experiments conducted in near zero gravity environment as well as highly accurate analytical formulation for the coalescence process. The viscosity of the liquid is determined by allowing the computed free surface shape relaxation time to be adjusted in response to the measured free surface velocity for two coalescing drops. Results are presented from two sets of validation experiments for the method which were conducted on board aircraft flying parabolic trajectories. In these tests the viscosity of a highly viscous liquid, namely glycerin, was determined at different temperatures using the drop coalescence method described in here. The experiments measured the free surface velocity of two glycerin drops coalescing under the action of surface tension alone in low gravity environment using high speed photography. The liquid viscosity was determined by adjusting the computed free surface velocity values to the measured experimental data. The results of these experiments were found to agree reasonably well with the known viscosity for the test liquid used.

Antar, Basil N.↗

Signatures of current loop coalescence in solar flares

The nonlinear coalescence instability of current carrying solar loops can explain many of the characteristics of the solar flares such as their impulsive nature, heating and high energy particle acceleration, amplitude oscillations of electromagnetic emission as well as the characteristics of 2-D microwave images obtained during a solar flare. The physical characteristics of the explosive coalescence of currents are presented in detail through computer simulation and theory. Canonical characteristics of the explosive coalescence are: (1) a large amount of impulsive increase of kinetic energies of electrons and ions; (2) simultaneous heating and acceleration of electrons and ions in high and low energy spectra; (3) ensuing quasi-periodic amplitude oscillations in fields and particle quantities; and (4) the double peak (or triple peak) structure in these profiles, participate in the coalescence process, yielding varieties of phenomena.

Sakai, J.↗

Surface-tension-induced mixing following coalescence of initially stationary drops

The momentumless coalescence of drops of the same liquid, separated by an immiscible host, is studied experimentally. Observations show that for low-viscosity drops of unequal sizes, there is considerable mixing following coalescence, with the smaller drop penetrating the larger drop as a vortex. The extreme case of coalescence of a small drop with the bulk of the same liquid at a flat interface with an immiscible liquid is studied in detail. The penetration depths of small drops (1-5 mm) following coalescence are measured and correlated with theoretical predictions. It is found that in the range of the investigation, the penetration depth is proportional to the 5/4 power of drop diameter and inversely proportional to the square root of the drop viscosity.

Anilkumar, A. V.↗

Momentumless coalescence of drops

The dynamics of mixing and satellite drop formation following the coalescence of initially stationary low-viscosity drops of the same liquid has been investigated using immiscible systems. The main parameters of interest are the drop sizes, the drop viscosity and the host viscosity. For drops of equal sizes there is no mixing following coalescence, which is consistent with that first demonstrated on the Skylab. However, for drops of unequal sizes there is considerable mixing with the smaller drop penetrating the larger drop as a vortex. In the extreme case of coalescence of a small drop with the bulk of the same liquid at a flat interface, the measured penetration depth is found to be proportional to the 5/4 th power of the drop diameter and inversely proportional to the square root of drop viscosity. When the drop and host viscosities are comparable, drop penetration is prematurely terminated by the formation of a satellite drop. However, when the drop diameter ratio (large to small) is below a critical number, satellite drop formation is inhibited and coalescence goes to completion. The influence of drop-host viscosity ratio on this critical diameter ratio has been examined.

Anilkumar, A. V.↗

Phase segregation due to simultaneous migration and coalescence

The primary objective of the research is to perform ground-based analysis and experiments on the interaction and coalescence of drops (or bubbles) leading to macroscopic phase separation. Migration of the drops occurs as a result of the individual and collective action of gravity and thermocapillary effects. Larger drops migrate faster than smaller ones, leading to the possibility of collisions and coalescence. Coalescence increases the rate of macroscopic phase separation, since the result is larger drops with higher migration rates. It is hoped that the understanding gained will lead to the design of microgravity experiments to further elucidate the mechanisms governing coalescence and phase separation.

Davis, Robert H.↗

Hydrodynamics of binary coalescence. 1: Polytropes with stiff equations of state

We performed a series of three-dimensional hydrodynamic calculations of binary coalescence using the smoothed particle hydrodynamics (SPH) method. The initial conditions are exact polytropic equilibrium configurations on the verge of dynamical instability. We consider synchronized equilbria only and concentrate on stiff equations of state, with adiabatic Gamma greater than 5/3. We assume that the polytropic constants (K identically equal to P/(rho(exp Gamma)) are the same for both components. These conditions apply well to models of neutron star binaries. Accordingly, we discuss our results in the context of the Laser Interferometer Gravitational-Wave Observatory (LIGO) project, and we calculate the emission of gravitational radiation in the quadruple approximation. The fully nonlinear development of the instability is followed using SPH until a new equilibrium configuration is reached by the system. We find that the properties of this final configuration depend sensitively on both the compressibility and mass ratio. An axisymmetric merged configuration is always produced when the adiabatic exponent Gamma approximately less than 2.3. As a consequence, the emission of gravitational radiation shuts off abruptly right after the onset of dynamical instability. In contrast, triaxial merged configurations are obtained when Gamma approximately greater than 2.3, and the system continues to emit gravitational waves after the final coalescence. Systems with mass ratios q not equal to 1 typically become dynamically unstable before the onset of mass transfer. Stable mass transfer from one neutron star to another in a close binary is therefore probably ruled out. For a mass ratio q approximately less than 0.5, however, dynamical mass transfer can temporarily retard the coalescence by causing a rapid reexpansion of the binary into a new, slightly eccentric but dynamically stable orbit. The maximum amplitude h(sub max) and peak luminosity L(sub max) of the gravitational waves emitted during the final coalescence are nearly independent of Gamma, but depend sensitively on the mass ratio q. The approximate scalings we find are h(sub max) varies as q(exp 2) and L(sub max) varies as q(exp 6) for q close to unity.

Rasio, Frederic A.↗

Non-Coalescence Effects in Microgravity

Non-coalescence of two bodies of the same liquid and the suppression of contact between liquid drops and solid surfaces is being studied through a pair of parallel investigations being conducted at the Georgia Institute of Technology and the Microgravity Research and Support (MARS) Center in Naples, Italy. Both non-coalescence and contact suppression are achieved by exploiting the mechanism of thermocapillary convection to drive a lubricating film of surrounding gas (air) into the space between the two liquid free surfaces (non-coalescence) or between the drop free surface and the solid (contact suppression). Earlier experiments performed included flow-visualization experiments in both axisymmetric and (nearly) two-dimensional geometries and quantitative measurements of film thickness in the contact-suppression case in both geometries. Work done in the second year has focused on obtaining quantitative results relating to the effects of variable air pressure, development of analytical and numerical models of non-coalescing droplets and to pursuing potential applications of these self-lubricated systems.

Neitzel, G. Paul↗

Viscosity Measurement using Drop Coalescence in Microgravity

We present in here details of a new method, using drop coalescence, for application in microgravity environment for determining the viscosity of highly viscous undercooled liquids. The method has the advantage of eliminating heterogeneous nucleation at container walls caused by crystallization of undercooled liquids during processing. Also, due to the rapidity of the measurement, homogeneous nucleation would be avoided. The technique relies on both a highly accurate solution to the Navier-Stokes equations as well as on data gathered from experiments conducted in near zero gravity environment. The liquid viscosity is determined by allowing the computed free surface shape relaxation time to be adjusted in response to the measured free surface velocity of two coalescing drops. Results are presented from two validation experiments of the method which were conducted recently on board the NASA KC-135 aircraft. In these tests the viscosity of a highly viscous liquid, such as glycerine at different temperatures, was determined to reasonable accuracy using the liquid coalescence method. The experiments measured the free surface velocity of two glycerine drops coalescing under the action of surface tension alone in low gravity environment using high speed photography. The free surface velocity was then compared with the computed values obtained from different viscosity values. The results of these experiments were found to agree reasonably well with the calculated values.

Antar, Basil N.↗

Interactions Forces and the Flow-Induced Coalescence of Drops and Bubbles

In order to accomplish the proposed macroscale experimental goals, we designed and built a pair of miniaturized computer-controlled four-roll mills, similar but much smaller than the 4-roll mill that had been develop earlier in Prof. Leal's group for studies of drop deformation and breakup. This unique experimental facility allows for controlled experiments on the breakup and coalescence of very small drops in the size range of 20-200 micrometers in diameter for a wide variety of flows and under a wide range of flow conditions including time-dependent flows, etc. The small size of this device is necessary for coalescence studies, since coalescence occurs in viscous fluids at capillary numbers that are large enough to be experimentally accessible only for drops that are smaller than approximately 100_m in diameter. Using these miniaturized 4-roll mills, we have obtained the first quantitative data (so far as we are aware) on the flow-induced coalescence process.

Leal, L. Gary↗

Non-Coalescence in Microgravity: Science and Technology

Non-coalescence of two bodies of the same liquid and the suppression of contact between liquid drops and solid surfaces (nonwetting) has been studied through a pair of parallel investigations being conducted at the Georgia Institute of Technology and the Microgravity Research and Support (MARS) Center in Naples, Italy. Both non- coalescence and nonwetting may achieved by either: i) exploiting the mechanism of thermocapillary convection to drive a lubricating film of surrounding gas (air) into the space between the two liquid free surfaces (non-coalescence) or between the drop free surface and the solid (nonwetting); or ii) using the otherwise forced motion of the solid (or one liquid) surface to generate the lubricating film. These, and other types of related phenomena are discussed in our recent review article (Neitzel GP, Dell'Aversana P. 2002. Noncoalescence and nonwetting behavior of liquids. Annual Review of Fluid Mechanics 34: 267-89). This project was a continuation of earlier research on this subject and includes the possible uses of non-coalescing/wetting systems in technological applications.

Neitzel, G. Paul↗