Search NASA⌕ Search

SEARCH · Search NASA

Results for “COAX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Test cavity and Iris-to-Coax transition for tuning and high-power verification of SNS DTL iris couplers

The Spallation Neutron Source (SNS) Drift Tube Linac (DTL) employs iris couplers to efficiently deliver RF power into the accelerating structure. To support the development, tuning, and high‑power conditioning of these couplers prior to installation in the actual DTLs, a dedicated test cavity and an iris‑to‑coaxial transition structure have been designed. This work presents the electromagnetic design, simulation, and optimization of the test setup, enabling precise characterization of the iris coupler’s performance. The transition structure allows for tuning of the iris opening dimensions without requiring a waveguide taper or full‑size waveguide transitions, while maintaining impedance matching between the coaxial feed and the iris geometry to minimize reflection and power loss. During low‑power tests, the iris opening di-mensions can be evaluated using the iris‑to‑coax transi-tion attached to the test cavity. For high‑power condi-tioning, full‑size waveguides with ceramic vacuum win-dows are connected to the test cavity to replicate opera-tional conditions. Key design parameters were optimized using computer-aided simulation, and sensitivity studies were conducted to assess the impact of mechanical toler-ances on RF performance. The resulting test platform provides a reliable and efficient means for tuning and validating iris couplers, contributing to improved opera-tional stability in the SNS DTL.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Direction-specific enhanced diffusion of CO 2 in chiral hexagonal boron nitride nanotubes

To meet performance requirements, the next generation of gas separation membranes will need both high gas permeability and selectivity, attainable if we could coax adsorbates to minimize random Brownian motion and produce direction-specific diffusion along a desired axis. In this atomistic modeling study, we detail how direction-specific diffusion of CO 2 can be achieved in chiral hexagonal boron nitride nanotubes (hBNNTs) by means of a non-Knudsen diffusion mechanism. Our findings detail how this mechanism of diffusion is driven by interactions with the tube walls and enables the CO 2 molecules to diffuse along the nanotube’s z-axis with minimized collisions and directional changes. hBNNTs with chiral indices exhibit CO 2 diffusion rates faster than non-chiral tubes of comparable and larger diameters. Of the hBNNTs studied, a (7,3) tube appears to be ideally sized (3.7 Å radius) exhibiting CO 2 diffusion that is 3.4 times faster than diatomic N 2 . Applying this mechanism of diffusion to hypothetical sheet membranes prepared with aligned chiral (7,3) hBNNTs results in membranes with a calculated CO 2 /N 2 permselectivity of 170 and a CO 2 permeability limit of nearly 1.35 ×10 7 Barrer, readily surpassing the Robeson upper bound for CO 2 /N 2 separations.

CO2↗

Probing shocks interacting with radiation waves with the Radishock experiment

Both radiation flows and shocks have been extensively studied in the laboratory in the past few decades due to their critical roles in many astrophysical and high-energy density physics processes. In the Radishock experiment, a halfraum-powered radiation wave is driven into a low-density foam and interacts with an ablatively driven, counter-propagating shock. The interacting waves produce a spike in energy density with a temperature greater than the local temperature of the individual waves. As in the successful predecessor experiment, COAX, the primary diagnostic uses absorption spectroscopy at many locations down the cylindrical target, enabling a spatial temperature inference of the radiation wave and its interactions with the shock. Combined with a radiography diagnostic that is capable of imaging the shock and interaction features, we are able to study and inform model predictions of the interaction spike phenomenon. We describe the underlying physics behind the shock interactions with the radiation front and the implications of this experimental study for a broad range of astrophysical phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗