At least 19 records

High tensile alloy of copper to mitigate current collector deformation in silicon electrodes for lithium-ion batteries

The volumetric changes of silicon electrodes, along with the strong adhesive properties of certain binders, can lead to plastic deformation of the current collector and create damage in the electrode coating. Here, in this study, we report a detailed study of silicon coatings on a high-tensile alloy (HTA) foil of copper with strength over twice that of conventional copper foils. The HTA current collectors with high mechanical strength can mitigate plastic deformation upon continuous cycling. At moderate areal capacities (2.5–3 mAh cm −2 ), conventional copper foils show significant wrinkling after only a few electrochemical cycles, whereas the HTA foils remain intact. We demonstrate viability of the HTA foils in large format xx6395 pouch cells, in which the HTA current collectors remain intact even at an areal capacity of 4.5 mAh cm −2 ; in contrast, wrinkles form in conventional copper current collectors increasing the likelihood of lithium plating. Computational studies show that stresses generated during cycling of silicon electrodes are very high in the current collector and at the current collector-coating interface, explaining the wrinkling of conventional Cu foils. Our studies highlight importance of current collector to solve the electrochemical and chemo-mechanical performance challenges associated with high-loading silicon electrodes.

Chemo-mechanical degradation↗

Comparison under a simulated sun of two black-nickel-coated flat-plate solar collectors with a nonselective black-paint-coated collector

A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).

Simon, F. F.↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Secondary-electron-emission losses in multistage depressed collectors and traveling-wave-tube efficiency improvements with carbon collector electrode surfaces

Secondary-electron-emission losses in multistage depressed collectors (MDC's) and their effects on overall traveling-wave-tube (TWT) efficiency were investigated. Two representative TWT's and several computer-modeled MDC's were used. The experimental techniques provide the measurement of both the TWT overall and the collector efficiencies. The TWT-MDC performance was optimized and measured over a wide range of operating conditions, with geometrically identical collectors, which utilized different electrode surface materials. Comparisons of the performance of copper electrodes to that of various forms of carbon, including pyrolytic and iisotropic graphites, were stressed. The results indicate that: (1) a significant improvement in the TWT overall efficiency was obtained in all cases by the use of carbon, rather than copper electrodes, and (2) that the extent of this efficiency enhancement depended on the characteristics of the TWT, the TWT operating point, the MDC design, and collector voltages. Ion textured graphite was found to be particularly effective in minimizing the secondary-electron-emission losses. Experimental and analytical results, however, indicate that it is at least as important to provide a maximum amount of electrostatic suppression of secondary electrons by proper MDC design. Such suppression, which is obtained by ensuring that a substantial suppressing electric field exists over the regions of the electrodes where most of the current is incident, was found to be very effective. Experimental results indicate that, with proper MDC design and the use of electrode surfaces with low secondary-electron yield, degradation of the collector efficiency can be limited to a few percent.

Ramins, P.↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Solar collectors. I - Fundamentals and collectors of the past and present

The paper is a state-of-the-art review aiming to familiarize those who are new in the solar energy field with past accomplishment in solar energy utilization. Consideration is given to the design features and performance definition of solar collectors. The characteristics of planar collectors, line focusing collectors, and point focusing collectors (including the central receiver concept) are briefly discussed.

Selcuk, M. K.↗

Computer controlled performance mapping of thermionic converters: effect of collector, guard-ring potential imbalances on the observed collector current-density, voltage characteristics and limited range performance map of an etched-rhenium, niobium planar converter

The effect of collector, guard-ring potential imbalance on the observed collector-current-density J, collector-to-emitter voltage V characteristic was evaluated in a planar, fixed-space, guard-ringed thermionic converter. The J,V characteristic was swept in a period of 15 msec by a variable load. A computerized data acquisition system recorded test parameters. The results indicate minimal distortion of the J,V curve in the power output quadrant for the nominal guard-ring circuit configuration. Considerable distortion, along with a lowering of the ignited-mode striking voltage, was observed for the configuration with the emitter shorted to the guard ring. A limited-range performance map of an etched-rhenium, niobium, planar converter was obtained by using an improved computer program for the data acquisition system.

Manista, E. J.↗

Standard performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 3-7/8 inches

Basic test results are given of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes, and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

Source record↗

Standardized performance tests of collectors of solar thermal energy: A selectively coated, flat-plate copper collector with one transparent cover and a tube-to-tube spacing of 5 5/8 inches

This preliminary data report gives basic test results of a flat-plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency is correlated in terms of inlet temperature and flux level.

Source record↗

Measurements and Calculations of the Effects of Distortions in the Collector Surface on Efficiencies of Umbrella-Type Solar Collectors

The meridional tensions along the ribs in a Mylar-covered umbrella-type solar collector produce a distortion in the reflecting surface that is detrimental to the image in the focal plane. The investigation reported herein was made to obtain measured and calculated geometric efficiencies of umbrella-type collectors as affected by these surface distortions. These studies show that if the tension transverse to the ribs is increased relative to the meridional tensions, the distortion is reduced and higher efficiencies can be attained, and if the transverse tension is small, the number of ribs in the collector must be increased for higher efficiencies.

Bond, Victor R.↗

Solar collector performance evaluation with the NASA-Lewis solar simulator-results for an all-glass-evacuated-tubular selectively-coated collector with a diffuse reflector

A solar collector was tested in a solar simulator for inlet temperatures of temperatures of 70 to 200 F, flux levels of 230 and rate of 7 lb/(hr)(sq. ft), and incident angles of 0 deg, 33 deg, and 52 deg. Test results plotted in a form suggested by analysis indicate a very low heat loss coefficient. The collector shows excellent performance on an all-day performance basis, and also for conditions corresponding to temperatures required in solar Rankine systems and/or for low flux level radiation.

Simon, F.↗