Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

Absorber Column CFD model validation against PNNL’s device-scale absorber column on the LCFS unit

Absorber column has been widely used for CO 2 capture in the coal-fired power plants. High-fidelity CFD models play an important role in absorber column design and solvents optimization, which help enhance the CO 2 capture efficiency and reduce the operation cost. This report provides a comprehensive description of the development of CFD absorber models at two different levels, the design and implementation of PNNL’s device-scale absorber column experiment, and the methodology to combine the CFD results, experiment data, and Aspen model for a better understanding of the interface area in packed column. A composite model is firstly proposed in the Discrete Element Method (DEM) packing process, which can model the complex geometry of various packing elements. This generates a realistic packing pattern and accurate packing porosity ε and specific area a p compared to the actual values for absorber column used in LCFS. Two level of CFD absorber models were developed, namely the full-size column model (FCM) to simulate the entire packed column with a focus on the wall/entrance effects, and the representative column model (RCM) to simulate a section of column with a focus on the sensitivity study of interface area. A Design of Experiment (DoE) plan was developed to guide the collection of 100 run CFD data and 12 experiment runs. The 100 CFD runs were carried out in the RCM with Pro-Pak packing and cover a wide operation range and solvent properties. Impact of influential factors on the interface area in packed column were investigated in details. The CFD interface area was then combined with the experimental data and Aspen model to infer some information of the effective contact angle in the column. The accuracy and uncertainties in the interface area and contact angle can be quantified.

01 COAL, LIGNITE, AND PEAT↗

Optode Images, and Dissolved Oxygen Data from Sand and Sediment Flow-through Column Experiments associated with: "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns"

This data package is associated with the publication "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns" submitted to Frontiers in Water (Garayburu-Caruso et al., 2022). This work presents a novel application of planar optode technology to sediment columns that allows the study of well-constrained flow fields without the need to assume completely homogeneous flow. We introduce a flow-through column with the interior coated in an oxygen sensing film and a series of sampling ports as a unique tool capable of capturing changes in dissolved oxygen (DO) at high frequency (10 s) and spatial (< 1 mm) resolution across the length of a column. In addition, we provide custom scripts that allows image processing steps to be automated and consistently reproduced over a variety of experimental conditions. This dataset is comprised of four folders (1) 01_Riverbed_Sediment_Experiment, (2) 02_Sand_Experiment, (3) 01_Riverbed_Sediment_Raw_Images, and (4) 02_Sand_Experiment_Raw_Images. 01_Riverbed_Sediment_Experiment contains (1) a subfolder with csv files that contain statistical parameters from the linear regressions applied to each optode image, (2) a subfolder with csv files from DO data measured by in-line sensors, (3) a subfolder with csv files containing column and injection specific input parameters for the image processing script, and (4) a subfolder with scripts used to process the images and create associated figures. 02_Sand_Experiment contains (1) a subfolder with csv files containing column and injection-specific input parameters for the image processing script, and (2) a subfolder with scripts used to process the images and create associated figures. 01_Riverbed_Sediment_Raw_Images (spited in 3 parts due to size) contains a subfolder with raw red, and green images from the optode system during the MilliQ Injection, Vanillin Injection or Vanillin + Sampling Injection respectively. 02_Sand_Experiment_Raw_Images contains a subfolder with raw red, and green images from the optode system. Outside of the main folders there is a csv containing file-level metadata and a csv data dictionary defining column headers for all csv files contained in the data package.

54 ENVIRONMENTAL SCIENCES↗

A method for determining the column curve from tests of columns with equal restraints against rotation on the ends

The results are presented of a theoretical study for the determination of the column curve from tests of column specimens having ends equally restrained against rotation. The theory of this problem is studied and a curve is shown relating the fixity coefficient c to the critical load, the length of the column, and the magnitude of the elastic restraint. A method of using this curve for the determination of the column curve for columns with pin ends from tests of columns with elastically restrained ends is presented. The results of the method as applied to a series of tests on thin-strip columns of stainless steel are also given.

Lundquist, Eugene E↗

Characterization of Errors in Satellite-Based HCHO/NO 2 Tropospheric Column Ratios With Respect to Chemistry, Column-to-PBL Translation, Spatial Representation, and Retrieval Uncertainties

The availability of formaldehyde (HCHO) (a proxy for volatile organic compound reactivity) and nitrogen dioxide (NO 2 ) (a proxy for nitrogen oxides) tropospheric columns from ultraviolet–visible (UV–Vis) satellites has motivated many to use their ratios to gain some insights into the near-surface ozone sensitivity. Strong emphasis has been placed on the challenges that come with transforming what is being observed in the tropospheric column to what is actually in the planetary boundary layer (PBL) and near the surface; however, little attention has been paid to other sources of error such as chemistry, spatial representation, and retrieval uncertainties. Here we leverage a wide spectrum of tools and data to quantify those errors carefully. Concerning the chemistry error, a well-characterized box model constrained by more than 500 h of aircraft data from NASA's air quality campaigns is used to simulate the ratio of the chemical loss of HO 2 + RO 2 (LRO x ) to the chemical loss of NO x (LNO x ). Subsequently, we challenge the predictive power of HCHO/NO 2 ratios (FNRs), which are commonly applied in current research, in detecting the underlying ozone regimes by comparing them to LRO x /LNO x . FNRs show a strongly linear (R 2 =0.94) relationship with LRO x /LNO x , but only on the logarithmic scale. Following the baseline (i.e., ln(LRO x /LNO x ) = −1.0 ± 0.2) with the model and mechanism (CB06, r2) used for segregating NO x -sensitive from VOC-sensitive regimes, we observe a broad range of FNR thresholds ranging from 1 to 4. The transitioning ratios strictly follow a Gaussian distribution with a mean and standard deviation of 1.8 and 0.4, respectively. This implies that the FNR has an inherent 20 % standard error (1σ) resulting from not accurately describing the RO x –HO x cycle. We calculate high ozone production rates (PO 3 ) dominated by large HCHO × NO 2 concentration levels, a new proxy for the abundance of ozone precursors. The relationship between PO 3 and HCHO × NO 2 becomes more pronounced when moving towards NO x -sensitive regions due to nonlinear chemistry; our results indicate that there is fruitful information in the HCHO × NO 2 metric that has not been utilized in ozone studies. The vast amount of vertical information on HCHO and NO 2 concentrations from the air quality campaigns enables us to parameterize the vertical shapes of FNRs using a second-order rational function permitting an analytical solution for an altitude adjustment factor to partition the tropospheric columns into the PBL region. We propose a mathematical solution to the spatial representation error based on modeling isotropic semivariograms. Based on summertime-averaged data, the Ozone Monitoring Instrument (OMI) loses 12 % of its spatial information at its native resolution with respect to a high-resolution sensor like the TROPOspheric Monitoring Instrument (TROPOMI) (> 5.5 × 3.5 km 2 ). A pixel with a grid size of 216 km 2 fails at capturing ∼ 65 % of the spatial information in FNRs at a 50 km length scale comparable to the size of a large urban center (e.g., Los Angeles). We ultimately leverage a large suite of in situ and ground-based remote sensing measurements to draw the error distributions of daily TROPOMI and OMI tropospheric NO 2 and HCHO columns. At a 68 % confidence interval (1σ), errors pertaining to daily TROPOMI observations, either HCHO or tropospheric NO 2 columns, should be above 1.2–1.5 × 10 16 molec. cm −2 to attain a 20 %–30 % standard error in the ratio. This level of error is almost non-achievable with the OMI given its large error in HCHO. The satellite column retrieval error is the largest contributor to the total error (40 %–90 %) in the FNRs. Due to a stronger signal in cities, the total relative error (< 50 %) tends to be mild, whereas areas with low vegetation and anthropogenic sources (e.g., the Rocky Mountains) are markedly uncertain (> 100 %). Our study suggests that continuing development in the retrieval algorithm and sensor design and calibration is essential to be able to advance the application of FNRs beyond a qualitative metric.

Amir H. Souri↗

Comparison of automated pre-column and post-column analysis of amino acid oligomers

It has been shown that various amino acids will polymerize under plausible prebiotic conditions on mineral surfaces, such as clays and soluble salts, to form varying amounts of oligomers (n = 2-6). The investigations of these surface reactions required a quantitative method for the separation and detection of these amino acid oligomers at the picomole level in the presence of nanomole levels of the parent amino acid. In initial high-performance liquid chromatography (HPLC) studies using a classical postcolumn o-phthalaldehyde (OPA) derivatization ion-exchange HPLC procedure with fluorescence detection, problems encountered included lengthy analysis time, inadequate separation and large relative differences in sensitivity for the separated species, expressed as a variable fluorescent yield, which contributed to poor quantitation. We have compared a simple, automated, pre-column OPA derivatization and reversed-phase HPLC method with the classical post-column OPA derivatization and ion-exchange HPLC procedure. A comparison of UV and fluorescent detection of the amino acid oligomers is also presented. The conclusion reached is that the pre-column OPA derivatization, reversed-phase HPLC and UV detection produces enhanced separation, improved sensitivity and faster analysis than post-column OPA derivatization, ion-exchange HPLC and fluorescence detection.

NASA Discipline Exobiology↗

Stress Analysis of Columns and Beam Columns by the Photoelastic Method

Principles of similarity and other factors in the design of models for photoelastic testing are discussed. Some approximate theoretical equations, useful in the analysis of results obtained from photoelastic tests are derived. Examples of the use of photoelastic techniques and the analysis of results as applied to uniform and tapered beam columns, circular rings, and statically indeterminate frames, are given. It is concluded that this method is an effective tool for the analysis of structures in which column action is present, particularly in tapered beam columns, and in statically indeterminate structures in which the distribution of loads in the structures is influenced by bending moments due to axial loads in one or more members.

BEAM-COLUMNS - STRESSES↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

Interface stability of a fluid column subject to periodic accelerations normal to the longitudinal axis of the column

This project investigates the interface stability of an inviscid fluid column in the presence of a periodic acceleration field which has a component normal to the longitudinal axis of the column. A ramification of this configuration is that perturbations cannot be considered axisymmetric. The column is taken to be infinite in length. Floquet analysis will be utilized in the stability investigation.

Lyell, M. J.↗

A two-fluid single-column model of turbulent shallow convection. Part II: Single-column model formulation and numerics

The two-fluid single-column model of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) is extended to include moisture and horizontal wind shear. Turbulent kinetic energy is introduced as a prognostic variable, dependence on a diagnosed boundary-layer height is removed, and subfilter fluxes are approximated using a two-fluid version of a Mellor–Yamada scheme. Three mechanisms for entrainment and detrainment processes are introduced, which represent entrainment of unstable air at the surface, forced detrainment of air at the top of the boundary/cloud layers, and turbulent mixing that relaxes the convective fluid to a reference profile. A semi-implicit Eulerian discretization replaces the semi-implicit semi-Lagrangian implementation of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) to improve numerical stability and conservation. The equations for the implicit time step are solved using a quasi-Newton method, which is shown to perform well in numerical tests for conservation and convergence. The two-fluid single-column model presented in this article will be applied to simulations of shallow cumulus convection in Part III.

54 ENVIRONMENTAL SCIENCES↗

Design procedures for fiber composite structural components: Rods, columns and beam columns

Step by step procedures are described which are used to design structural components (rods, columns, and beam columns) subjected to steady state mechanical loads and hydrothermal environments. Illustrative examples are presented for structural components designed for static tensile and compressive loads, and fatigue as well as for moisture and temperature effects. Each example is set up as a sample design illustrating the detailed steps that are used to design similar components.

Chamis, C. C.↗

Miniature Distillation Column for Producing LOX From Air

The figure shows components of a distillation column intended for use as part of a system that produces high-purity liquid oxygen (LOX) from air by distillation. (The column could be easily modified to produce high-purity liquid nitrogen.) Whereas typical industrial distillation columns for producing high-purity liquid oxygen and/or nitrogen are hundreds of feet tall, this distillation column is less than 3 ft (less than about 0.9 m) tall. This column was developed to trickle-charge a LOX-based emergency oxygen system (EOS) for a large commercial aircraft. A description of the industrial production of liquid oxygen and liquid nitrogen by distillation is prerequisite to a meaningful description of the present miniaturized distillation column. Typically, such industrial production takes place in a chemical processing plant in which large quantities of high-pressure air are expanded in a turboexpander to (1) recover a portion of the electrical power required to compress the air and (2) partially liquefy the air. The resulting two-phase flow of air is sent to the middle of a distillation column. The liquid phase is oxygen-rich, and its oxygen purity increases as it flows down the column. The vapor phase is nitrogen-rich and its nitrogen purity increases as it flows up the column. A heater or heat exchanger, commonly denoted a reboiler, is at the bottom of the column. The reboiler is so named because its role is to reboil some of the liquid oxygen collected at the bottom of the column to provide a flow of oxygen-rich vapor. As the oxygen-rich vapor flows up the column, it absorbs the nitrogen in the down-flowing liquid by mass transfer. Once the vapor leaves the lower portion of the column, it interacts with down-flowing nitrogen liquid that has been condensed in a heat exchanger, commonly denoted a condenser, at the top of the column. Liquid oxygen and liquid nitrogen products are obtained by draining some of the purified product at the bottom and top of the column, respectively. Because distillation is a mass-transfer process, the purity of the product(s) can be increased by increasing the effectiveness of the mass-transfer process (increasing the mass-transfer coefficient) and/or by increasing the available surface area for mass transfer through increased column height. The diameter of a distillation column is fixed by pressure-drop and mass-flow requirements. The approach taken in designing the present distillation column to be short yet capable of yielding a product of acceptably high purity was to pay careful attention to design details that affect mass-transfer processes.

Rozzi, Jay C.↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Parameters Impacting Columnated Granular Soil Pneumatic Seal Performance

The ability of a column of loose granular soil to form a pneumatic seal was investigated by varying the diameter of the soil column, the effective column height, and the level of compaction in the soil. The soil column diameter was tested at three levels using pipes with inner diameters measuring 5.08, 10.16, and 15.24 centimeters (2, 4, and 6 inches). Soil was filled in each pipe to form 15, 30, and 45 centimeter (6, 12, and 18 inch) tall soil columns. Each diameter/height configuration was also tested at three levels of soil compaction, compared by calculating the bulk density of the soil with mass and volume measurements. GRC-1a simulant was used, with approximate low/medium/high bulk densities of 1.6, 1.75, and 1.9 g/cc achieved with a combination of vibration and tamping. The order of tests for a given column diameter was randomized and repeated three times. With the top of the soil open to atmosphere at room temperature, compressed air was injected through a small diffuser at the column base with several small downward-facing holes. The number and size of these holes was scaled such that a constant total inlet orifice area to column cross sectional area ratio was maintained for each column diameter. Inlet air pressure was slowly increased via a precision regulator to preserve quasi-static equilibrium in the soil column to minimize the impact of dynamics. Air pressure was increased all the way through the static and bubbling regimes until slugging or turbulent behavior was observed in the soil to ensure that the entire static regime had been captured during data collection. A three-factor, three-level analysis of variance (ANOVA) statistical analysis was performed on the resulting data to determine the extent to which each physical parameter impacted the soil column seal performance. It was concluded that there is statistically significant evidence that column height, and the interaction between column height and diameter impact soil seal performance. In all other cases there was insufficient data to identify a statistically significant causal relationship. Additionally, plots were generated comparing experimental data to the predictive formula developed by Ogino et al. for fluidized beds in 1993. Because this model was developed for industrial spouted fluidized beds, the accuracy of its output prior to fluidization in the static seal ‘edge case’ is unknown, especially considering in this application the working gas was diffused across the column base rather than being injected through a spout. Further, the fidelity of the model had not yet been tested with lunar soil simulants. Plotting the Ogino et al. model alongside test data allows for a more intuitive sense of the impact of test parameters on soil seal performance, as well as providing a quick means to further tune this predictive model for more accurate use with static seals across granular lunar soil simulants. The model provided by Ogino et al. was further tuned using test data to determine the degree to which a spouted bed model could be applied to a slightly modified set of testing conditions: lunar soil simulants and a more diffuse, homogeneous application of pneumatic pressure. A Matlab script was created to test different values for the leading coefficient and exponents in Ogino’s formula. The script swept preset ranges, then iterated with higher resolutions across narrower ranges to converge on the optimal value for each parameter. The resulting adjusted model was compared to the original, as well as test data with noticeable improvements across the entire test domain.

Jack Stewart↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗