Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLUMN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Absorber Column CFD model validation against PNNL’s device-scale absorber column on the LCFS unit

Absorber column has been widely used for CO 2 capture in the coal-fired power plants. High-fidelity CFD models play an important role in absorber column design and solvents optimization, which help enhance the CO 2 capture efficiency and reduce the operation cost. This report provides a comprehensive description of the development of CFD absorber models at two different levels, the design and implementation of PNNL’s device-scale absorber column experiment, and the methodology to combine the CFD results, experiment data, and Aspen model for a better understanding of the interface area in packed column. A composite model is firstly proposed in the Discrete Element Method (DEM) packing process, which can model the complex geometry of various packing elements. This generates a realistic packing pattern and accurate packing porosity ε and specific area a p compared to the actual values for absorber column used in LCFS. Two level of CFD absorber models were developed, namely the full-size column model (FCM) to simulate the entire packed column with a focus on the wall/entrance effects, and the representative column model (RCM) to simulate a section of column with a focus on the sensitivity study of interface area. A Design of Experiment (DoE) plan was developed to guide the collection of 100 run CFD data and 12 experiment runs. The 100 CFD runs were carried out in the RCM with Pro-Pak packing and cover a wide operation range and solvent properties. Impact of influential factors on the interface area in packed column were investigated in details. The CFD interface area was then combined with the experimental data and Aspen model to infer some information of the effective contact angle in the column. The accuracy and uncertainties in the interface area and contact angle can be quantified.

01 COAL, LIGNITE, AND PEAT↗

Optode Images, and Dissolved Oxygen Data from Sand and Sediment Flow-through Column Experiments associated with: "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns"

This data package is associated with the publication "2-D Imaging of Dissolved Oxygen Concentration in Flow-Through Sediment Columns" submitted to Frontiers in Water (Garayburu-Caruso et al., 2022). This work presents a novel application of planar optode technology to sediment columns that allows the study of well-constrained flow fields without the need to assume completely homogeneous flow. We introduce a flow-through column with the interior coated in an oxygen sensing film and a series of sampling ports as a unique tool capable of capturing changes in dissolved oxygen (DO) at high frequency (10 s) and spatial (< 1 mm) resolution across the length of a column. In addition, we provide custom scripts that allows image processing steps to be automated and consistently reproduced over a variety of experimental conditions. This dataset is comprised of four folders (1) 01_Riverbed_Sediment_Experiment, (2) 02_Sand_Experiment, (3) 01_Riverbed_Sediment_Raw_Images, and (4) 02_Sand_Experiment_Raw_Images. 01_Riverbed_Sediment_Experiment contains (1) a subfolder with csv files that contain statistical parameters from the linear regressions applied to each optode image, (2) a subfolder with csv files from DO data measured by in-line sensors, (3) a subfolder with csv files containing column and injection specific input parameters for the image processing script, and (4) a subfolder with scripts used to process the images and create associated figures. 02_Sand_Experiment contains (1) a subfolder with csv files containing column and injection-specific input parameters for the image processing script, and (2) a subfolder with scripts used to process the images and create associated figures. 01_Riverbed_Sediment_Raw_Images (spited in 3 parts due to size) contains a subfolder with raw red, and green images from the optode system during the MilliQ Injection, Vanillin Injection or Vanillin + Sampling Injection respectively. 02_Sand_Experiment_Raw_Images contains a subfolder with raw red, and green images from the optode system. Outside of the main folders there is a csv containing file-level metadata and a csv data dictionary defining column headers for all csv files contained in the data package.

54 ENVIRONMENTAL SCIENCES↗

Hydrodynamics of countercurrent flows in a structured packed column: effects of initial wetting and dynamic contact angle

The structured packed column has gained considerable attention as a prospective technology to mitigate carbon dioxide emissions from thermal power plants. The computational flow investigation of such systems is a multiscale problem, and local hydrodynamics plays a key role in overall column efficiency. Accordingly, multiphase flow studies in the representative elementary unit (REU) of a packed column can offer insights into the local flow behavior such as flow pattern, interfacial area, etc. The interfacial area plays a key role in the overall interphase mass transfer and thereby in separation efficiency. The predicted effective area matches well with corresponding ones in experiments for Mellapak 250.Y packings. The contact angle (i.e., solid substrate behavior) is one of the critical factors that dictates wettings, and thereby the interfacial area. The dynamic contact angle (DCA) was considered in order to explore the effects of contact angle hysteresis on the interfacial area. DCA has more pronounced impact on the interfacial area for a solvent possessing a higher value of surface tension and equilibrium contact angle. The interfacial area shows temporal undulation and does not achieve a pseudo steady state due to the capillary force. In contrary, the interfacial area gets a net value for a solvent having low surface tension value. Further, specification of the static contact angle at the solid substrate shows the least value of the interfacial area. We also extensively studied the effect of the initial sheet condition (dry vs wet) on the interfacial area. The initially wetted sheets show slightly higher value of the interfacial area as compared to the initially dry sheets at a fixed flow rate for a solvent having high surface tension value. Wetting hysteresis decreases with increasing liquid loads. On the other hand, wetting hysteresis does not occur for a solvent having value of low surface tension and equilibrium contact angle.

structured packings, dynamic contact angle, interf↗

A two-fluid single-column model of turbulent shallow convection. Part II: Single-column model formulation and numerics

The two-fluid single-column model of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) is extended to include moisture and horizontal wind shear. Turbulent kinetic energy is introduced as a prognostic variable, dependence on a diagnosed boundary-layer height is removed, and subfilter fluxes are approximated using a two-fluid version of a Mellor–Yamada scheme. Three mechanisms for entrainment and detrainment processes are introduced, which represent entrainment of unstable air at the surface, forced detrainment of air at the top of the boundary/cloud layers, and turbulent mixing that relaxes the convective fluid to a reference profile. A semi-implicit Eulerian discretization replaces the semi-implicit semi-Lagrangian implementation of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) to improve numerical stability and conservation. The equations for the implicit time step are solved using a quasi-Newton method, which is shown to perform well in numerical tests for conservation and convergence. The two-fluid single-column model presented in this article will be applied to simulations of shallow cumulus convection in Part III.

54 ENVIRONMENTAL SCIENCES↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-column cryogenic air separation: Enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N 2 -enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde’s single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde’s single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O 2 . However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

20 FOSSIL-FUELED POWER PLANTS↗

Applications of a dual-column technique in actinide separations

Selective separation of an individual actinide of interest from other actinides and accompanying lanthanides is a challenging task in radiochemistry and radioanalytical chemistry. This paper illustrates a dual column technique (i.e., stacked columns of two appropriate resins) to separate an individual actinide of interest, where the selection of two resins and a common effluent running through the stacked columns are key parameters in design of an appropriate dual column. This paper describes the dual column design and practice with two examples, one for a heavy actinide 249Bk and the other for a light actinide 230U. In the former case, stacked columns of anion exchange (AX) resin and LN resin replaced the traditional CX-AHIB method used at Oak Ridge National Laboratory for 60 years. In the latter case, an elution process with an AX column followed with a stacked column of AX resin and a DGA resin was applied, instead of traditional methods, e.g., PUREX or U-TEVA methods. Application results of the dual column method to the two example actinides are displayed, while the considerations in method design and the required conditions are discussed.

Du, Miting↗

Statistical characterization of a shock interacting with an inclined gas column

We present a statistical characterization of the interaction between a planar shock and a finite-diameter, cylindrical column of dense gas based on three-dimensional, large-eddy simulation results. In the simulation, the column of gas is initially inclined at an angle $\alpha _0$ with respect to the shock plane. Effects of the initial column angle on the mixing characteristics are examined at Mach number 2.0 for column incline angles $1^\circ$ , $5^\circ$ , $10^\circ$ and $30^\circ$ . Mean velocity profiles show that the column angle affects the gas velocity components in the vertical plane, but not in the spanwise direction. The gas undergoes higher initial upward acceleration at larger initial column incline angles. With time, the gas motion tends to become one-dimensional in the streamwise direction. Initially, velocity fluctuations are most intense within the interior of the column, but concentrate near the column leading edge over time. At high wavenumbers $\kappa$ , the turbulent kinetic energy spectra follow a power-law scaling of $\kappa ^{-1}$ . The structure functions of the mass fraction do not clearly demonstrate power-law scaling except at early times for $\alpha _0=30^\circ$ , manifesting overall trends very similar to those observed in earlier experiments. Probability distributions of the mass fraction show independence of the mean and the standard deviation of the mixed gas on $\alpha _0$ . The column angle was also found to have little effect on the mixing efficiency characterized by the molecular mixedness. Velocity components in the streamwise and transverse directions tend towards a bimodal distribution for larger $\alpha _{0}$ .

42 ENGINEERING↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-column cryogenic air separation: enabling efficient oxygen production with rapid startup and low capital costs—application to low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for more flexible, low-carbon fossil-fuel plants with lower capital costs. This then drives the need to improve the cryogenic air separation unit (ASU). To address this changing landscape, we explore a Praxair single-column ASU (PSC-ASU) design with the goal of reducing costs and improving flexibility, compared to a conventional double-column ASU. The PSC-ASU incorporates partial air condensation and air pre-separation in the bottom reboiler with a phase separator as well as N2-enriched vapor condensation in the upper reboiler to decrease energy consumption, as compared to Linde's single-column ASU. All three of the above-mentioned ASU designs are simulated in Aspen Plus and analyzed. An economic analysis is applied to evaluate the relative cost savings of the PSC-ASU compared to the double-column ASU. Results suggest that the specific energy consumption of the PSC-ASU is significantly lower than that of Linde's single-column ASU due to a drastically improved oxygen recovery rate. Although this improved oxygen recovery rate is still lower than that of the double-column ASU, the required pressure ratio of the main air compressor is 21% lower than that of the double-column ASU. As a result, the specific energy consumption of the PSC-ASU is only 1.9% greater than that of the double-column ASU for producing 95.1 mol% O2. However, the PSC-ASU reduces the hourly capital cost by 19% due to the elimination of a high-pressure column. This would effectively decrease the total hourly cost of the ASU, and thus the total hourly cost of low-carbon, fossil-fuel power plants that require oxygen.

Cheng, Mao↗

Investigation of countercurrent flow profile and liquid holdup in random packed column with local CFD data

Liquid holdup and mass transfer area are critical parameters used in packed column design and CO 2 capture efficiency prediction. Compared to experimental methods, 3D computational fluid dynamics (CFD) can provide high-resolution data for studying countercurrent flow hydrodynamics in a packed column. In this paper, a framework was established for modeling the liquid–gas countercurrent flow in a random packed column with pall rings. Besides the column-averaged information, the radial pall ring distribution, velocity, and liquid holdup profiles are obtained in the simulations. The radial two-phase velocity and liquid holdup profiles show significant fluctuations caused by the non-uniform pall ring distribution. The entrance effect and wall influence are also observed in the packed column. By using local countercurrent flow information, the packing specific area $a_p$ and liquid velocity $u_L$ range are significantly expanded for liquid holdup hL prediction. This enables us to develop the liquid holdup correlation with one packing size and six CFD runs only. The proposed power law of the liquid holdup correlation $h_L~u_L^{0.44}$ indicates the random packed column falls in a viscous to turbulent transition regime with a Reynolds Number range of [6.7–40.2]. The derived liquid holdup correlation is in good agreement with existing correlations that are developed using the column-averaged experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chromatographic Modeling of 1-Foot Detritiation Test Column Results for the Optimization of Regeneration Time

This report documents the methods and results of a modeling study on a series of data generated by 1-foot test columns for the Water Detritiation project. In order to compliment modeling work already in progress on this project, a purely empirical curve-fitting approach is used in this study to determine chromatographic performance indicators such as retention time, curve width, and the number of chromatographic stages. The data used in this study comes from four sets of chromatographic test separations performed in March through May of 2017 using 1-foot columns. All are using the same flow rates and temperature (room temperature, nominally 25 C°). The first set of data (referred to in this report as the Column 1 data) is a series of twelve breakthrough curve measurements. Prior to each of these twelve runs, the column was regenerated by flowing hydrogen gas through the column, for increasing amounts of time, ranging from 2 hours to 25 hours. The second set of data (referred to as the Column 2 data) is comprised of five measurements of breakthrough curves measured in similar fashion as the Column 1 data, across a range of regeneration times from 2 to 21 hours. The third set of data (referred to as the Purge data) is of three breakthrough curves, measured after a regeneration time of 8 hours, which takes place after a nitrogen purge of 15, 30, or 45 minutes. The fourth data set is a series of five breakthrough curve measurements using a 2 nd batch of stationary phase, taken after regeneration times ranging from 2 to 20 hours. The overall modeling approach is as follows. First, the data is pre-processed for formatting, artifact removal, and is normalized. The data is then fit by integrated versions of four common chromatographic models. The best model is chosen based on the predictive performance of the model, and chromatographic performance values are calculated based on the best model’s fit parameters. Each of these processes are detailed below.

42 ENGINEERING↗

Multiphase computational fluid dynamics modeling of reacting flows in absorption columns for carbon capture

First-principles derived computational fluid dynamics (CFD) simulations have been proposed as a fundamental tool for investigating solvent-based CO 2 absorption in packed columns due to their ability to accurately represent the underlying nonlinear, multiscale dynamics. Numerous studies have previously utilized such CFD simulations to investigate hydrodynamics of columns with structured and random packings by assessing the key hydrodynamic metrics such as the interfacial and wetted areas. While mapping such metrics for different conditions is essential to the optimization of absorption columns, it is not sufficient, as the CO 2 capture rate depends also on the coupled, nonlinear dynamics from the underlying chemical reaction kinetics, thermodynamics, and heat-transfer rates. In this work, we present detailed CFD simulation results augmented by incorporating the effects of interfacial physical mass transfer of CO 2 , heat release from chemical reaction kinetics, and thermophysical property variations from resulting temperature gradients. We demonstrate the applicability of the proposed approach in numerically assessing the performance of packed columns by evaluating key hydrodynamic quantities, CO 2 absorption rates, and temperature rise in a reference column with packings that are structurally similar to the Sulzer Mellapak™ 250.Y packing, for different solvent inflow velocities and temperatures. Predictions from simulation results are found to be consistent with the trends in experimental observations from the literature, suggesting that the predictive capabilities of the simulation framework can be leveraged to guide the future development of absorber-column designs and optimized process flowsheets.

Absorption columns↗