Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPARISON SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Software Comparison for Renewable Energy Deployment in a Distribution Network

The main objective of this report is to evaluate different software options for performing robust distributed generation (DG) power system modeling. The features and capabilities of four simulation tools, OpenDSS, GridLAB-D, CYMDIST, and PowerWorld Simulator, are compared to analyze their effectiveness in analyzing distribution networks with DG. OpenDSS and GridLAB-D, two open source software, have the capability to simulate networks with fluctuating data values. These packages allow the running of a simulation each time instant by iterating only the main script file. CYMDIST, a commercial software, allows for time-series simulation to study variations on network controls. PowerWorld Simulator, another commercial tool, has a batch mode simulation function through the 'Time Step Simulation' tool, which obtains solutions for a list of specified time points. PowerWorld Simulator is intended for analysis of transmission-level systems, while the other three are designed for distribution systems. CYMDIST and PowerWorld Simulator feature easy-to-use graphical user interfaces (GUIs). OpenDSS and GridLAB-D, on the other hand, are based on command-line programs, which increase the time necessary to become familiar with the software packages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A transcriptome software comparison for the analyses of treatments expected to give subtle gene expression responses

Background: In this comparative study we evaluate the performance of four software tools: DNAstar-D (DESeq2), DNAstar-E (edgeR), CLC Genomics and Partek Flow for identification of differentially expressed genes (DEGs) using a transcriptome of E. coli. The RNA-seq data are from the effect of below-background radiation 5.5 nGy total dose (0.2nGy/hr) on E. coli grown shielded from natural radiation 655 m below ground in a pre-World War II steel vault. The gene expression response to three supplemented sources of radiation designed to mimic natural background, 1952 – 5720 nGy in total dose (71–208 nGy/hr), are compared to this “radiation-deprived” treatment. In addition, RNA-seq data of Caenorhabditis elegans nematode from similar radiation treatments was analyzed by three of the software packages. Results: In E. coli, the four software programs identified one of the supplementary sources of radiation (KCl) to evoke about 5 times more transcribed genes than the minus-radiation treatment (69–114 differentially expressed genes, DEGs), and so the rest of the analyses used this KCl vs “Minus” comparison. After imposing a 30-read minimum cutoff, one of the DNAStar options shared two of the three steps (mapping, normalization, and statistic) with Partek Flow (they both used median of ratios to normalize and the DESeq2 statistical package), and these two programs identified the highest number of DEGs in common with each other (53). In contrast, when the programs used different approaches in each of the three steps, between 31 and 40 DEGs were found in common. Regarding the extent of expression differences, three of the four programs gave high fold-change results (15–178 fold), but one (DNAstar’s DESeq2) resulted in more conservative fold-changes (1.5–3.5). In a parallel study comparing three qPCR commercial validation software programs, these programs also gave variable results as to which genes were significantly regulated. Similarly, the C. elegans analysis showed exaggerated fold-changes in CLC and DNAstar’s edgeR while DNAstar-D was more conservative. Conclusions: Regarding the extent of expression (fold-change), and considering the subtlety of the very low level radiation treatments, in E. coli three of the four programs gave what we consider exaggerated fold-change results (15 – 178 fold), but one (DNAstar’s DESeq2) gave more realistic fold-changes (1.5–3.5). When RT-qPCR validation comparisons to transcriptome results were carried out, they supported the more conservative DNAstar-D’s expression results. When another model organism’s (nematode) response to these radiation differences was similarly analyzed, DNAstar-D also resulted in the most conservative expression patterns. Therefore, we would propose DESeq2 (“DNAstar-D”) as an appropriate software tool for differential gene expression studies for treatments expected to give subtle transcriptome responses.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of Tendril TrueHome Using Software-to-Software Comparison

This study performed comparative evaluation of EnergyPlus version 8.6 and Tendril TrueHome, two physics-based home energy simulation models, to identify differences in energy consumption predictions between the two programs and resolve discrepancies between them. EnergyPlus is considered a benchmark, best-in-class software tool for building energy simulation. This exercise sought to improve both software tools through additional evaluation/scrutiny.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-211: Comparison of Seven New TrueBeam Linacs with Enhanced Beam Data Conformance Using a Beam Comparison Software Tool

Purpose: To develop an independent software tool to assist in commissioning linacs with enhanced beam conformance, as well as perform ongoing QA for dosimetrically equivalent linacs. Methods: Linac manufacturers offer enhanced beam conformance as an option to allow for clinics to complete commissioning efficiently, as well as implement dosimetrically equivalent linacs. The specification for enhanced conformance includes PDD as well as profiles within 80% FWHM. Recently, we commissioned seven Varian TrueBeam linacs with enhanced beam conformance. We developed a software tool in Visual Basic to allow us to load the reference beam data and compare our beam data during commissioning to evaluate enhanced beam conformance. This tool also allowed us to upload our beam data used for commissioning our dosimetrically equivalent beam models to compare and tweak each of our linac beams to match our modelled data in Varian’s Eclipse TPS. This tool will also be used during annual QA of the linacs to compare our beam data to our baseline data, as required by TG-142. Results: Our software tool was used to check beam conformance for seven TrueBeam linacs that we commissioned in the past six months. Using our tool we found that the factory conformed linacs showed up to 3.82% difference in their beam profile data upon installation. Using our beam comparison tool, we were able to adjust the energy and profiles of our beams to accomplish a better than 1.00% point by point data conformance. Conclusion: The availability of quantitative comparison tools is essential to accept and commission linacs with enhanced beam conformance, as well as to beam match multiple linacs. We further intend to use the same tool to ensure our beam data conforms to the commissioning beam data during our annual QA in keeping with the requirements of TG-142.

43 PARTICLE ACCELERATORS↗

A Systematic Comparison for Consistent Scenario Development Using Microscopic Simulation Software

This study aims to explore a methodology that enables the development of consistent traffic micro simulation for emerging traffic and vehicle control technologies for improved mobility and energy efficiency across different modeling platforms. Researchers might study the same application on different platforms and have the need to benchmark across platforms. However, there lacks a systematic study on simulation software comparison, especially for emerging mobility and energy efficiency applications. For this, a systematic scenario development and evaluation approach is presented and demonstrated to compare scenarios generated in different traffic microsimulation platforms. Network-level and vehicle-level trip performance results of the traffic scenario are evaluated in three microscopic simulation platforms - VISSIM, AIMSUN, and SUMO. The results indicate that the network-level performance is consistent among the three software suites except when the demand is high, where the energy consumption performance varies.

Saroj, Abhilasha [ORNL] (ORCID:0000000191178063)↗

The Supernovae Analysis Application (SNAP)

The SuperNovae Analysis aPplication (SNAP) is a new tool for the analysis of SN observations and validation of SN models. SNAP consists of a publicly available relational database with observational light curve, theoretical light curve, and correlation table sets with statistical comparison software, and a web interface available to the community. The theoretical models are intended to span a gridded range of parameter space. The goal is to have users upload new SN models or new SN observations and run the comparison software to determine correlations via the website. There are problems looming on the horizon that SNAP is beginning to solve. For example, large surveys will discover thousands of SNe annually. Frequently, the parameter space of a new SN event is unbounded. SNAP will be a resource to constrain parameters and determine if an event needs follow-up without spending resources to create new light curve models from scratch. Second, there is no rapidly available, systematic way to determine degeneracies between parameters, or even what physics is needed to model a realistic SN. The correlations made within the SNAP system are beginning to solve these problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of software models for energy savings from cool roofs

For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savings to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Software Models for Energy Savings from Cool Roofs

A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

New, Joshua Ryan↗

Rovibronic molecular line list for the $N_2(C^3Π_u–B^3Π_g)$ second positive system

Here, a line list for the N second positive system, $B^3Π_g—C^3Π_u$, has been compiled using the PGOPHER spectral simulation software. The line list extends the number of vibrational states of the $B^3Π_g$ up to v=29 and a maximum rotational state of J=150 for simulation temperatures up to 7000 K. New electronic–vibrational transition moments were calculated using refined potential energy curves and a transition dipole moment with the DUO software. Comparisons to experimental data and the SPECAIR software have been used to validate the new line list. The results are available in ASCII ExoMol .state and .trans files and as a PGOPHER input file for use in spectral analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stereo-DIC Challenge 1.0 – Rigid Body Motion of a Complex Shape

Background Stereo-DIC is a widely used optical measurement technique that provides a dense full-field 3D measurement of the shape, displacement, and strain of a solid sample. When compared with 2D-DIC, Stereo-DIC provides greater flexibility and expands its use beyond flat, planar specimens. Furthermore, the widespread availability of commercial systems has led to the adoption of the technique throughout industry, academia, and government research labs. Objective Even though some research has been done to understand the effects of different experimental and stereo-DIC parameters, no reference is available to benchmark and compare the performance of current stereo-DIC algorithms to each other. Methods This paper provides the description and analysis of a carefully controlled 3D experiment and associated images used to compare the results from five subset based DIC software packages. Both the images and analysis codes used in this paper to compare the results are described here and are available for download and use for continued research. Results We show that over a very large range of motion, the 3D errors are very small, less than 80μm over a travel of ±20 mm out-of-plane and ±20 mm in-plane. While all codes performed similarly, there are important differences noted in the paper. Conclusion The image sets and results comparison software are hosted by the International DIC Society (www.iDICs.org) and are freely available for download and analysis for comparison with results in this paper. Furthermore, it is hoped that this set of images can be used for future research in improving stereo-DIC by future authors.

Algorithms comparison↗

SU-E-J-26: Analysis of Image Quality in CBCT QA Using a Treatment Planning System

Purpose: The objective of this study is to propose an alternative QA technique that analyzes imaging quality(IQ) in CBCT-QA processing. Methods: A catphan phantom was used to take CT imaging data set that were imported into a treatment planning system - Eclipse. The image quality was analyzed in terms of in-slice geometry resolution, Hounsfield numbers(HU) accuracy, mean-slice thickness, edge-to-center uniformity, low contrast resolution, and high contrast spatial resolution in Eclipse workstation. The CBCT-QA was also analyzed by OBI-workstation and a commercial software. Comparison was made to evaluation feasibility in a TPS environment. Results: The analysis of IQ was conducted in Eclipse v10.0 TPS. In-slice geometric resolution was measured between 2-rods in section CTP404 and repeated for all 4 rods with the difference between expected and measured values less than +/−0.1 cm. For HU, the difference between expected and measured values in HU was found much less than +/−40. Mean slice thickness measured by a distance on the wire proportional to scanner increment multiplying by a factor of 0.42. After repeating measurements to 4 wires, the average difference between expected and measured values was less +/−0.124 mm in slice thickness. HU uniformity was measured in section CTP486 with the tolerance less than +/−40 HU. Low contrast resolution in section CTP515 and high contrast resolution in section CTP528 were found to be 7 disks in diameter of 4 mm and 6 lp/cm, respectively. Eclipse TPS results indicated a good agreement to those obtained in OBI workstation and ImagePro software for major parameters. Conclusion: An analysis of IQ was proposed as an alternative CBCT QA processing. Based upon measured data assessment, proposed method was accurate and consistent to IQ evaluation and TG142 guideline. The approach was to utilize TPS resource, which can be valuable to re-planning, verification, and delivery in adaptive therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Interface Reduction for Time-Domain Analysis of Hurty/Craig-Bampton Superelements with Frictional Contact

Virtual prototyping in engineering design relies today on modern numerical models of contacting structures with accurate resolution of interface mechanics, which strongly affect the system-level stiffness and energy dissipation due to frictional losses. High-fidelity modeling within the localized interfaces is required to resolve local quantities of interest that may drive design decisions. The high-resolution finite element meshes necessary to resolve inter-component stresses tend to be computationally expensive, particularly when the analyst is interested in response time histories. The Hurty/Craig-Bampton (HCB) transformation is a widely used method in structural dynamics for reducing the interior portion of a finite element model while having the ability to retain all nonlinear contact degrees of freedom (DOF) in physical coordinates. These models may still require many DOF to adequately resolve the kinematics of the interface, leading to inadequate reduction and computational savings. This study proposes a novel interface reduction method to overcome these challenges by means of system-level characteristic constraint (SCC) modes and properly orthogonal interface modal derivatives (POIMDs) for transient dynamic analyses. Both SCC modes and POIMDs are computed using the reduced HCB mass and stiffness matrices, which can be directly computed from many commercial finite element analysis software. Comparison of time history responses to an impulse-type load in a mechanical beam assembly indicate that the interface-reduced model correlates well with the HCB truth model. Localized features like slip and contact area are well-represented in the time domain when the beam assembly is loaded with a broadband excitation. The proposed method also yields reduced-order models with greater critical timestep lengths for explicit integration schemes.

42 ENGINEERING↗

SU-E-T-83: A Study On Evaluating the Directional Dependency of 2D Seven 29 Ion Chamber Array Clinically with Different IMRT Plans

Purpose: To evaluate the directional dependency of 2D seven 29 ion chamber array clinically with different IMRT plans. Methods: 25 patients already treated with IMRT plans were selected for the study. Verification plans were created for each treatment plan in eclipse 10 treatment planning system using the AAA algorithm with the 2D array and the Octavius CT phantom. Verification plans were done 2 times for a single patient. First plan with real IMRT (plan-related approach) and second plan with zero degree gantry angle (field-related approach). Measurements were performed on a Varian Clinac-iX, linear accelerator equipped with a millennium 120 multileaf collimator. Fluence was measured for all the delivered plans and analyzed using the verisoft software. Comparison was done by selecting the fluence delivered in static gantry (zero degree gantry) versus IMRT with real gantry angles. Results: The gamma pass percentage is greater than 97 % for all IMRT delivered with zero gantry angle and between 95%–98% for real gantry angles. Dose difference between the TPS calculated and measured for IMRT delivered with zero gantry angle was found to be between (0.03 to 0.06Gy) and with real gantry angles between (0.02 to 0.05Gy). There is a significant difference between the gamma analysis between the zero degree and true angle with a significance of 0.002. Standard deviation of gamma pass percentage between the IMRT plans with zero gantry angle was 0.68 and for IMRT with true gantry angle was found to be 0.74. Conclusion: The gamma analysis for IMRT with zero degree gantry angles shows higher pass percentage than IMRT delivered with true gantry angles. Verification plans delivered with true gantry angles lower the verification accuracy when 2D array is used for measurement.

60 APPLIED LIFE SCIENCES↗

Comparison of Deposition© software predictions to published experimental results for large (152 mm by 152 mm) square ducts

A comparison was performed between experimental aerosol deposition measurements in large air ducts, compared to predictions performed by the US Nuclear Regulatory Commission Deposition© software package. Although the Deposition© code was designed to calculate the transport of radioactive aerosols in small diameter sampling tubes, it was not certain that the software would adequately predict aerosol transport in large air ducts. Two sets of experimental data were used in this comparison, one set of results from small diameter (1.27 mm ID) tubes, and the other data set was from testing on large diameter (152 mm square) ventilation ducts. In general, the Deposition© software performs excellent predictions if the ductwork system has a computed aerosol percent penetration greater than 75% (with a 2.9% average error compared to experiments). For example, shorter duct systems have higher aerosol penetrations than a longer duct system of the same diameter. However, when the Deposition© software calculated an aerosol penetration less than about 75% for a particular duct system, the average percent error increased to 68.3% when compared to experimental measurements. The Deposition© software could therefore be used to ensure that an aerosol would have a high percent penetration through a ductwork system, but it should not be used to make (dosimetric) decisions about ductwork performance if the calculated percent penetration is less than 75%. This document includes a section of attached engineering formulas that explain the structure of the Excel spreadsheet calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of two software systems for quantification of myocardial blood flow in patients with hypertrophic cardiomyopathy

Backgorund: Quantification of myocardial blood flow (MBF) by positron emission tomography (PET) is important for investigation of angina in hypertrophic cardiomyopathy (HCM). Several software programs exist for MBF quantification, but they have been mostly evaluated in patients (with normal cardiac geometry), referred for evaluation of coronary artery disease (CAD). Software performance has not been evaluated in HCM patients who frequently have hyperdynamic LV function, LV outflow tract (LVOT) obstruction, small LV cavity size, and variation in the degree/location of LV hypertrophy. Aim: We compared results of MBF obtained using PMod, which permits manual segmentation, to those obtained by FDA-approved QPET software which has an automated segmentation algorithm. Methods: {sup 13}N-ammonia PET perfusion data were acquired in list mode at rest and during pharmacologic vasodilation, in 76 HCM patients and 10 non-HCM patients referred for evaluation of CAD (CAD group.) Data were resampled to create static, ECG-gated and 36-frame-dynamic images. Myocardial flow reserve (MFR) and MBF (in ml/min/g) were calculated using QPET and PMod softwares. Results: All HCM patients had asymmetric septal hypertrophy, and 50% had evidence of LVOT obstruction, whereas non-HCM patients (CAD group) had normal wall thickness and ejection fraction. PMod yielded significantly higher values for global and regional stress-MBF and MFR than for QPET in HCM. Reasonably fair correlation was observed for global rest-MBF, stress-MBF, and MFR using these two softwares (rest-MBF: r = 0.78; stress-MBF: r = 0.66.; MFR: r = 0.7) in HCM patients. Agreement between global MBF and MFR values improved when HCM patients with high spillover fractions (> 0.65) were excluded from the analysis (rest-MBF: r = 0.84; stress-MBF: r = 0.72; MFR: r = 0.8.) Regionally, the highest agreement between PMod and QPET was observed in the LAD territory (rest-MBF: r = 0.82, Stress-MBF: r = 0.68) where spillover fraction was the lowest. Unlike HCM patients, the non-HCM patients (CAD group) demonstrated excellent agreement in MBF/MFR values, obtained by the two softwares, when patients with high spillover fractions were excluded (rest-MBF: r = 0.95; stress-MBF: r = 0.92; MFR: r = 0.95). Conclusions: Anatomic characteristics specific to HCM hearts contribute to lower correlations between MBF/MFR values obtained by PMod and QPET, compared with non-HCM patients. These differences indicate that PMod and QPET cannot be used interchangeably for MBF/MFR analyses in HCM patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗