Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONCURRENT COOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic Line Rating Study of Concurrent Cooling for a Proposed Wind Farm

This report was prepared for the Wind Energy Technology Office for the FY 2021, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a gen tie-line associated with a proposed wind farm. By utilizing dynamic line rating, the concurrent cooling effect – maximum wind farm power output is coupled with additional cooling on the line – can be used to provide a smaller size conductor for the gen tie line, thus reducing the capital costs.

17 WIND ENERGY↗

Concurrent Cooling Effects of Dynamic Line Ratings on Wind Plant Gen-Tie Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 2 deliverable. This details the use of dynamic line rating technology to rate a series of gen tie lines connecting wind plants to the regional transmission lines. This consists of two primary study regions, the first on the desert west of Idaho Falls, and the second in the region east of the Cascades along the Columbia River Gorge. The TREAD program that was developed at INL was used to create generated gen-tie lines based on nearby regional transmission line connections. The capacity availability of the gen tie lines are compared with the power production of the wind farms. Overall, the INL Site location shows a much greater capacity for the gen-tie lines due to the higher wind speeds. Across both locations, the HRRR data shows higher wind speeds than observed at the observational weather stations. For both the Columbia Gorge and Idaho areas, the sites show that a statically rate gen-tie could carry additional capacity far above the rated during periods of high wind due to the concurrent cooling effects.

17 WIND ENERGY↗

Forecasted Dynamic Line Ratings for Regional Transmission Lines

This report was prepared for the Wind Energy Technology Office for the FY 2022, quarter 3 deliverable. This details the use of forecasted dynamic line rating as an improvement over static rating for three transmission lines in three regions of interest. A selection of wind plants across Idaho, the Columbia River Gorge and offshore wind in the NYSERDA territory were modeled for their concurrent cooling effects for dynamic line rating. Regional transmission lines for the wind plant interconnections were determined and a CFD domain was created to determine local wind flows over the lines. A dynamic line rating for each of the lines was calculated for both weather observation data and HRRR model forecast data. The comparison of peaks in the wind power production were compared to the DLR peaks. It was determined that for shorter regional transmission lines, the effect of concurrent cooling that commonly occur with gen-tie lines were still valid. Concurrent cooling effects drop as the length of the regional transmission lines increase in distance from the wind plants. In addition, the accuracy of the forecasted ampacity to the weather observation data for ampacity was assessed. In general, the accuracy was best for the INL region with the NOAA-maintained sites. The Columbia River Gorge and Long Island sites showed similar levels of accuracy for the forecasted DLR. The accuracy levels were around 11% for the INL region, 15% for Columbia River Gorge and 7% for New York Long Island. The higher error for the Columbia Gorge region is likely due to the sparse availability of weather stations available, whereas both the INL site and Long Island are well instrumented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Concurrent Wind Cooling in Power Transmission Lines

Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

09 BIOMASS FUELS↗

Using Dynamic Line Rating to Enhance Flexibility of Wind-involved Hybrid Energy System

By providing real-time overhead line ampacity, Dynamic Line Rating (DLR) is a potential technique to solve the transmission congestion issues that are threatening NPPs, especially when a nuclear plant is coupled with wind turbine generators. First, DLR can utilize the concurrent cooling effect and dynamic monitors on transmission lines to increase the line carry capacity and reduce congestion. Second, more frequent interactions between transmission lines and operators can increase the flexibility and create a more dynamic and responsive hybrid system. In general, DLR can increase the flexibility and optimize the efficiency of a hybrid system utilizing wind energy. DLR helps meet continuously fluctuating electricity demands with real-time observation of transmission lines for more accurate estimation of line carry capacity. For the fuel energy, DLR can contribute greatly in saving fuels and reducing carbon emission by providing timely information for adjusting generation levels. For HES's including NPPs, transmission congestion could be more serious and needs attention. Therefore, by providing additional transmission capacity, DLR can contribute to alleviate the congestion and congestion pricing impact that is threatening the current NPPs and prevent potential congestion that may constrain the operation of future hybrid system involved with a nuclear plant. However, either a fuel plant or nuclear plant is better coupled with a wind turbine to take advantage of the concurrent cooling effect and dynamic monitoring. The research team at Idaho National Laboratory, currently focused on the benefit of DLR technology to assist wind generation, is now exploring the feasibility of implementing the same technology into such HES and NPP. Future work will focus on the analysis of technique feasibility, challenges and benefit-cost analysis of integrating DLR into HES. Detailed studies are anticipated to evaluate the benefits of DLR on HES and NPP with transmission constraints. This paper explores a potential utilization of DLR in hybrid energy systems, especially those involving traditional fossil fuels or nuclear power coupled with wind energy. The goal is to increase the efficiency and flexibility of these types of hybrid systems in order to provide more secure, reliable and low-carbon energy.

17 WIND ENERGY↗

General Line Ampacity State Solver

INL’s General Line Ampacity State Solver (GLASS) is a high performance software platform that enables advanced grid system operations and planning efforts to be computed in real time. It enables the combination of advanced sensors and sensor networks, communication and data transfer channels, secure and reliable data management, and real-time processing through a flexible system architecture, with the ability to support and integrate with any utility enterprise system. GLASS is designed to help resolve the problems associated with thermally limited transmission and distribution networks, namely bare overhead power transmission lines. GLASS enables the methodology of Concurrent Cooling (Dynamic Line Rating) by reducing the need of using a cost-prohibited number of weather stations (reduce the number of weather stations per mile of overhead power line) to achieve the resolution necessary for individual electric transmission line span capacity calculations. GLASS achieves this by coupling real-time grid operations data and infrastructure architecture information with real-time field deployed weather station measurements and pre-computed Computational Fluid Dynamics (CFD)-based wind modeling interpolation parameters (look-up tables). GLASS uses mathematical models based on the IEEE 738 standard and builds off of the provided iterative solution using modern software paradigms and programming styles to provide a more robust and modular software system. GLASS also interfaces in real-time with utility companies using known transmission line spans and structures. GLASS provides real-time ampacity calculations based on recent weather station data as well as transmission line specifications. GLASS also allows the user to interact graphically with internal databases, which include information such as transmission line conductor types and thermal rating limits, weather station names and locations, specific transmission line span and structure locations, as well as recent ampacity calculations.

Gentle, Jake↗

Switching of Hybrid Improper Ferroelectricity in Oxide Double Perovskites

In ABO 3 -type perovskite oxides with Pnma symmetry, rotation (Q R+ , a 0 a 0 c + ) and tilt (Q T , a – a – c 0 ) of BO 6 octahedra are the two primary order parameters. These order parameters establish an inherent trilinear coupling with anti-ferroelectric A-site displacement (Q AFE ) to form the low-symmetry phase. The symmetry is further lowered in double perovskite oxides (DPOs) due to A/A' cation ordering. It in turn makes these systems polar via hybrid improper ferroelectric mechanism, primarily driven by Q R+ and Q T . Naturally, it has been believed that functionalities such as polarization can also be switched by tuning these primary order parameters. However, mystery around finding switching mechanism still remains. Our study based on density functional theory calculations combined with finite-temperature molecular dynamics simulations shows that the polarization switching is a two-step process, driven by out-of-phase rotation (Q R– , a 0 a 0 c – when Q T = 0 or, a – a – b – when Q T ≠ 0). A series of polar DPOs such as KLnFeOsO 6 [Ln = Sm, Gd, Dy, Tm (lanthanides) and Y (rare earth)], all belonging to P2 1 symmetry, are considered in this investigation. The polarization switching P ($\overrightarrow{P}$) occurs at a very high temperature of ~1150 K through a phase transition, from a polar (P2 1 ) phase with $\overrightarrow{P}$(+) to $\overrightarrow{P}$(-) via a non-polar P4/n phase. The switching itself is metastable in nature. The switching (both polarization and spin state) is only observed for a very short period of time (~23 ps) that poses limitation on using such a mechanism in memory device realization. We demonstrate a concurrent heating–cooling procedure to overcome such shortcoming. In conclusion, simulations conducted at 600 K further imply that long lasting switching can be achieved, at least for 1.2 ns for 600 K, and ideally for an infinite time, if the material is heated just above the T c followed by rapid cooling to a temperature below T c .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GLASS: General Line Ampacity State Solver

The U.S. installed more than 8,000 megawatts of wind generation in 2016. Wind energy is now powering more than 20 million homes. Idaho National Laboratory technology uses real time weather information and computer models to help utilities integrate more wind energy, relieving transmission line congestion, and extending the life time of existing grid infrastructure.

17 WIND ENERGY↗

Strengthening mechanisms in directed energy deposited austenitic stainless steel

Microstructures and mechanical properties are evaluated in austenitic stainless steel structures fabricated by directed energy deposition (DED) considering the effects of applied loading orientation, build geometry, and distance from the deposition baseplate. Locations within an as-deposited build with different thermomechanical history display different yield strength, while those locations with similar history have approximately the same yield strength, regardless of test specimen orientation. Thermal expansion of deposited material near the baseplate is inhibited by the mechanical constraint imposed by the baseplate, promoting plastic deformation and producing a high density of dislocations. Concurrently, high initial cooling rates decrease away from the baseplate as the build is heated, causing an increased spacing of cellular solidification features. An analysis of strengthening mechanisms quantitatively established for the first time the important strengthening contribution of high dislocation densities in the materials (166–191 MPa) to yield strength that ranged from 438 to 553 MPa in the present DED fabricated structures. A newly adopted mechanistic relationship for microsegregation strengthening from the literature indicated an additional important contribution to strengthening (123–135 MPa) due to the cellular solidification features. These findings are corroborated by the measured evolution of microstructure and hardness caused by annealing the DED material. Finally, these results suggest that the mechanical properties of deposited austenitic stainless steels can be influenced by controlling thermomechanical history during the manufacturing process to alter the character of compositional microsegregation and the amount of induced plastic deformation.

36 MATERIALS SCIENCE↗

Pathways for decarbonization of the buildings sector in Ukraine

The paper focuses on Ukraine’s intention to achieve a two-thirds reduction in buildings’ energy consumption for heating and cooling by 2050, concurrently aiming for net zero greenhouse gas emissions and heightened energy security. Here, the study examines the outcomes of retrofitting existing residential, commercial, and public buildings with highly efficient materials, improving construction standards, and transitioning to advanced heating systems. However, Russia’s invasion in 2022 inflicted substantial damage, prompting a shift from retrofit and decarbonization to reconstruction. The Ukrainian government’s Reconstruction Plan emphasizes clean, sustainable, and resilient energy systems. The study employs energy system and integrated assessment models (TIMES-Ukraine and GCAM-Ukraine) to explore scenarios taking into consideration the war, reconstruction, and a net zero CO 2 pathway. Using two models allowed the inter-model comparison. The analysis addresses vital questions on energy resiliency measures and the compounding effects of decarbonization. Findings indicate that Ukraine’s energy goals can be met through strategic retrofitting and economy-wide decarbonization, emphasizing the importance of low-carbon alternatives like district heating with renewable sources. Electrification with renewables and fuel-switching emerges as crucial for achieving building decarbonization. The study offers valuable insights into navigating energy challenges amidst the war and outlines a pathway for Ukraine’s sustainable energy future.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding Recent Global Hydroclimate Change Using Multivariate Detection and Attribution Techniques and GCM Experiments

The observed slowdown in the rate of global average surface temperature (T) warming during the post-1998 decade (referred to at the time as the “global warming hiatus”) posed a challenge for climate researchers because it was not captured in global climate models projection. Observational and modeling evidence hinted that that leveling of the T trend was linked with the simultaneous appearance of cold surface temperature in the eastern equatorial Pacific that formed a protracted La Niña-like state, a phenomenon known as the Inter-decadal Pacific Oscillation (IPO). It was however not clear whether the concurrent equatorial Pacific cooling was a regional response to the rise in atmospheric greenhouse gas levels or anthropogenic aerosols that is not captured by the climate models or whether it was an unrelated, serendipitous manifestation of a natural phenomenon, internal to the climate system. To resolve this issue, we proposed in this project to develop and apply fingerprinting methods to differentiate between the observed climate response to various external forcing agents and the manifestations of internal climate variability. The project also sought to find out if climate models are able to reproduce the change signals detected in key observational phenomena and if they can be used to investigate the underlying processes. As such we examined changes in global hydroclimate variability and in an outstanding example of regional hydroclimate change, namely the multi-decadal 20 th century change in Sahel rainfall.

54 ENVIRONMENTAL SCIENCES↗

Thermoeconomic analysis of a multigeneration system using waste heat from a triple power cycle

Multigeneration systems represent an appealing concept, due to their multiple benefits compared to standalone systems, which has motivated researchers to develop different types of multigeneration systems for several applications. Considering their significance, in this study, a novel multigeneration is proposed that uses the waste heat of a thermodynamically efficient triple power cycle with a 100 MWe capacity. The proposed system, which can generate power, freshwater, cooling, and domestic hot water concurrently, is evaluated using detailed thermodynamic and economic analyses. The triple cycle includes a simple Brayton cycle coupled with a supercritical carbon dioxide recompression cycle and a high-temperature organic Rankine cycle. The waste energy of the recompression and organic Rankine cycles is recovered by a half effect absorption chiller, a multi-effect distillation unit, and two heat exchangers. The results show that for an optimized triple cycle, up to 1,804 kW cooling and 8,472 m 3 /day of hot water can be generated from the hot supercritical carbon dioxide stream with a levelized cost of cooling and hot water of 0.0362/ton-hr and $0.6823/MWth, respectively. The integration of a multi-effect distillation unit with 7 effects can generate 4,167 m 3 /day freshwater with a levelized cost of water of $1.142/m 3 . Finally, the proposed multigeneration system offers a very promising application and a number of benefits such as a generating multiple useful products with no adverse effect on the thermodynamic efficiency of the triple power cycle.

Thermoeconomic analysis↗

Radio jet feedback and star formation in heavily obscured, hyperluminous quasars at redshifts ∼ 0.5–3. I. ALMA observations

We present Atacama Large Millimeter/submillimeter Array (ALMA) 870 μm (345 GHz) data for 49 high-redshift (0.47 < z < 2.85), luminous (11.7<log(L{sub bol}/L{sub ⊙})<14.2) radio-powerful active galactic nuclei (AGNs), obtained to constrain cool dust emission from starbursts concurrent with highly obscured radiative-mode black hole (BH) accretion in massive galaxies that possess a small radio jet. The sample was selected from the Wide-field Infrared Survey Explorer with extremely steep (red) mid-infrared colors and with compact radio emission from NVSS/FIRST. Twenty-six sources are detected at 870 μm, and we find that the sample has large mid- to far-infrared luminosity ratios, consistent with a dominant and highly obscured quasar. The rest-frame 3 GHz radio powers are 24.7<log(P{sub 3.0 GHz}/W Hz{sup −1})<27.3, and all sources are radio-intermediate or radio-loud. BH mass estimates are 7.7 < log(M{sub BH}/M{sub ⊙}) < 10.2. The rest-frame 1–5 μm spectral energy distributions are very similar to the “Hot DOGs” (hot dust-obscured galaxies), and steeper (redder) than almost any other known extragalactic sources. ISM masses estimated for the ALMA-detected sources are 9.9 < log (M{sub ISM}/M{sub ⊙}) < 11.75 assuming a dust temperature of 30 K. The cool dust emission is consistent with star formation rates reaching several thousand M{sub ⊙} yr{sup −1}, depending on the assumed dust temperature, but we cannot rule out the alternative that the AGN powers all the emission in some cases. Our best constrained source has radiative transfer solutions with approximately equal contributions from an obscured AGN and a young (10–15 Myr) compact starburst.

79 ASTRONOMY AND ASTROPHYSICS↗

The Influence of Environment on Post-Detonation Chemistry and Debris Formation (Abbreviated Final Report: 20-SI-006)

Predicting, responding to, or interpreting the chemical record preserved in debris derived from nuclear events can be challenging due to chemical fractionation. Chemical fractionation is where different species of the evolving radionuclide inventory segregate and/or are lost from the system over the timescales of debris formation. Both historic data and recent research suggest that the interaction and character of the local environment may exert controls on chemical fractionation by influencing the cooling and evolution of the associated fireball as well as the composition of the vapor term and resultant speciation. Prior to this work, an integrated platform permitting dynamic and concurrent consideration of physical and chemical evolution of early time post-detonation event environments did not exist. Our work merged historic data and experimental approaches to support development of a computational framework able to simulate fundamental processes (e.g., entrainment of local environment, oxidation chemistry, and cooling time scales) that may perturb the radionuclide inventory captured in post-detonation debris. Work with historic debris confirmed that entrained environmental material affect debris composition, structure, and radionuclide incorporation. Complementary work utilizing a readily controllable and tunable benchtop setup (a plasma flow reactor) simulated the late cooling of a nuclear fireball (e.g., T < 6000 K) and bounded the sensitivity of actinide speciation and particle size distribution to variations in oxygen concentration and cooling rates. Concurrent laser ablation and laser heating experiments were used to investigate the chemistry and physics of processes occurring in vaporized and/or rapidly heated actinides and other elements in the presence of oxygen. A more computationally efficient microphysical model was developed for predicting and evolving size distributions of particles forming from mixed vapor terms and simulating particle formation processes under a variety of extreme conditions. Continued study of historic nuclear event film confirmed that shockwave data and physics codes agree to within the uncertainty of the data. Good agreement was achieved for thermal emission from an airburst, however the paucity of low-temperature molecular opacity data for mixtures of air, bomb debris, entrained dirt, and water vapor complicate agreement for more elaborate scenarios. A multiphysics code (ALE3D) was modified to bring the necessary physics and chemistry, including these new data and insights, onto a single platform. Code development included improved initialization of large physical systems, modernization of chemistry capabilities, and modifications to enable inclusion of particle transport.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation of Melting-Layer Cooling Rate from Dual-Polarization Radar: Spectral Bin Model Simulations

Diabatic cooling from hydrometeor phase changes in the stratiform melting layer is of great interest to both operational forecasters and modelers for its societal and dynamical consequences. Attempts to estimate the melting-layer cooling rate typically rely on either the budgeting of hydrometeor content estimated from reflectivity Z or model-generated lookup tables scaled by the magnitude of Z in the bright band. Recent advances have been made in developing methods to observe the unique polarimetric characteristics of melting snow and the additional microphysical information they may contain. However, to date no work has looked at the thermodynamic information available from the polarimetric radar brightband signature. In this study, a one-dimensional spectral bin model of melting snow and a coupled polarimetric operator are used to study the relation between the polarimetric radar bright band and the melting-layer cooling rate. Simulations using a fixed particle size distribution (PSD) and variable environmental conditions show that the height and thickness of the bright band and the maximum brightband Z and specific differential phase shift [Formula: see text] are all sensitive to the ambient environment, while the differential reflectivity [Formula: see text] is relatively insensitive. Additional simulations of 2700 PSDs based on in situ observations above the melting layer indicate that the maximum Z, [Formula: see text], and [Formula: see text] within the melting layer are poorly correlated with the maximum cooling rate while [Formula: see text] is strongly correlated. Finally, model simulations suggest that, in addition to riming, concurrent changes in aggregation and precipitation intensity and the associated cooling may plausibly cause observed sagging brightband signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complex transport and magnetism in inhomogeneous mixed valence Ce 3 Ir 4 Ge 13

We report the discovery of Ce 3 Ir 4 Ge 13 , a Remeika phase with a complex array of structural, electronic, and magnetic properties. In this work, our single crystal x-ray diffraction measurements show that Ce 3 Ir 4 Ge 13 forms in the tetragonally distorted $I4_1/amd$ space group, which has three distinct rare earth sites. The electrical resistivity is almost temperature independent over three decades in temperature, from 0.4 K to 400 K, while the Hall coefficient measurements are consistent with a low-carrier semimetal. Magnetic susceptibility measurements reveal an effective moment, $μ^\text{exp}_\text{eff} = 1.87μ_B/$Ce, that falls significantly short of the expected value for Ce 3+ , suggesting that two of the rare earth sites are occupied by magnetic Ce 3+ while the third is occupied by nonmagnetic Ce 4+ . Upon cooling, Ce 3 Ir 4 Ge 13 first enters a short range magnetically ordered state below $T_\text{SRO}$ = 10 K, marked by a deviation from Curie-Weiss behavior in susceptibility and a broad field-independent heat capacity anomaly. At lower temperatures, we observe a second, sharper peak in the heat capacity at $T^\ast$ = 1.7 K, concurrent with a splitting of the field-cooled and zero-field-cooled susceptibilities. A small resistivity drop at $T^\ast$ suggests a loss of spin disorder scattering consistent with a magnetic ordering or spin freezing transition. Ce 3 Ir 4 Ge 13 is therefore a rare example of an inhomogeneous mixed valence compound with a complex array of thermodynamic and transport properties.

36 MATERIALS SCIENCE↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗