At least 19 records

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors

Rapid characterization and failure analysis of 6276 rooftop-harvested photovoltaic connectors

Photovoltaic (PV) connectors, which link modules in series and connect PV strings in parallel, have increasingly been recognized as a primary contributor to PV system failures and a source of numerous fire incidents. However, publicly available data on the rates and types of connector failures are scarce, primarily due to the proprietary nature of the information and the need for comprehensive analysis. This study represents the first large-scale investigation of harvested PV connectors, drawing from a dataset of 6276 connectors from residential rooftop solar systems across the United States. The outcome of this work is twofold: 1) we have established a rapid characterization method for large populations of harvested connectors, incorporating visual inspection, resistance measurements, and X-ray imaging; and 2) the analysis made possible by our rapid-processing method has revealed, for a population of connector models provided by a single rooftop installer, failure statistics and insights for various connector makes and models, installation practices, operating currents, and internal component displacements. This research identifies common failure modes that could be considered in future connector designs standards, and operations and maintenance practices, to ultimately improve the reliability of this vital component of PV infrastructure.

MC4

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors

Energy Connector [SWR-26-014]

The Energy Connector is a web-based software application that is designed to facilitate energy bill savings for low-income households through streamlined community solar subscriptions. By using the Connector, Developers and Subscription Managers can save money on acquisition costs and streamline enrollment without having to perform additional income verification.

Rivard, Tim [National Laboratory of the Rockies (N

Polymers used in 4 mm PV Connectors [Slides]

Polymer cracks are not a new problem in the PV industry. However, the suddenness and severity of the cracking connector model is new and concerning. Some sites are experiencing wide-spread cracking of a specific connector model. The preliminary investigation results are (1) there are potential clearance issues with the O-ring, leading to high mechanical stress; (2) potential use of lubrication yields polymer embrittlement; and (3) clear mechanical or chemical differences between the affected model and other PPE-based models using FTIR and tensile testing could not be demonstrated.

36 MATERIALS SCIENCE

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N

Reliability, Cost and Performance Risks of PV Connector Failures

This presentation is to guide interactive discussion by posing questions to workshop participants. Topic is reliability, maintenance cost, and performance risk associated with failure of PV connectors which make electrial connections between components.