Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAINER SAMPLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Evolution of the Orbiting Sample Container for a Future Mars Sample Return

Although NASA has no specific plans at this time to return samples from Mars, the Program Formulation Office of the Mars Exploration Program sponsors ongoing mission concept studies, systems analyses, and technology investments which explore different strategies for the potential return of samples from Mars, consistent with the charter of the program and stated priorities of the science community. A critical component of such a campaign would be an Orbiting Sample container (OS), which would contain the Mars samples to be returned to Earth. This paper discusses the most recent efforts by the JPL’s Mars Formulation Office to mature an OS design planned for use on a potential Mars Sample Return (MSR) mission. Similar to the “Decadal Study Architecture” [1], the current MSR architecture envisions as a three-mission campaign with each mission serving a critical role towards returning Martian rock and atmospheric samples back to Earth. An OS would be a central piece of hardware in the proposed MSR architecture due to its interfaces to all the three missions of the potential campaign. Additionally, numerous stakeholders and subsystems such as science and planetary protection impose challenging requirements on the OS’s functions and capabilities. As a result, designing an OS that meets all the requirements is challenging and quite complex. The story of the OS’s evolution from black box concept thru to the current-and-still-maturing baseline design is the focus of this paper. From the OS’s launch off Earth aboard a Sample Retrieval Lander (SRL) through to return to Earth, the design and functional requirements generated by and for each stage of the OS’s mission are discussed. Then, with an understanding of what the OS would be required to do, a mapping of the main requirements to the design features of the current OS concept is explained. Many tests and analyses have been conducted to support and validate the current OS design. Results from test and analysis in the areas of aerothermal, impact dynamics, optical tracking, and radio electromagnetics are presented.

Spencer, David↗

Dissolution actuated sample container

A sample collection vial and process of using a vial is provided. The sample collection vial has an opening secured by a dissolvable plug. When dissolved, liquids may enter into the interior of the collection vial passing along one or more edges of a dissolvable blocking member. As the blocking member is dissolved, a spring actuated closure is directed towards the opening of the vial which, when engaged, secures the vial contents against loss or contamination.

47 OTHER INSTRUMENTATION↗

A Study of Various Beacon Antennas for an Orbiting Sample Container of a Future Mars Sample Return Mission

This paper presents some results of a study of various options for a near-omnidirectional low-gain antenna at UHF frequencies, for a Mars Orbiting Sample Return Container (OS). The OS is part of a concept study for a future mission to return samples from Mars. It would be a critical component of such a mission, which would contain the Mars samples. The notional OS would be returned by a separate spacecraft to Earth. The OS would be identified and located by the spacecraft for pick-up from orbit by a beacon signal broadcast via a surface antenna. Several antenna designs were considered, but two promising ones are presented here which have good patterns with a better than 2:1 VSWR (Voltage Standing Wave Ratio), but meet different criteria for OS design options. One is a patch-type antenna and the other a slot-type antenna. Some data and test results of a fabricated breadboard antenna as well as discussions are provided.

Jamnejad, Vahraz↗

A fully contained sample holder capable of electron-yield detection at soft X-ray energies

A holder has been developed that enables electron yield-detected soft X-ray spectroscopy of fully contained samples at low temperature. Crucially, this design uses elements of the sample containment to collect ejected electrons, removing the need to expose samples directly to the vacuum environment of the spectrometer. The design is modular and should be adaptable to a number of different endstation configurations, enabling spectroscopy of air-sensitive, radioactive and vacuum-sensitive (biological) samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Flux pinning concepts for on-orbit capture and orientation of an MSR orbiting sample container

Concepts for on-orbit capture and orientation of a Mars orbiting sample container (OS) using flux pinning were developed as candidate technologies for potential Mars Sample Return (MSR). The systems consist of a set of type-II superconductors field cooled below their critical temperature using a cryocooler, and operate on an orbiting sample container with a series of permanent magnets spaced around the exterior, along with an integrated layer of shielding to preserve the magnetic properties of the returned samples. Benefits of the approaches include passive, non-contact capture and orientation, as well as a reduction in the number of actuators relative to various mechanical methods.

Chiu, Chi Yeung↗

Development of sealed sample containers and high resolution micro-tomography

A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adventitious Carbon on Primary Sample Containment Metal Surfaces

Future missions that return astromaterials with trace carbonaceous signatures will require strict protocols for reducing and controlling terrestrial carbon contamination. Adventitious carbon (AC) on primary sample containers and related hardware is an important source of that contamination. AC is a thin film layer or heterogeneously dispersed carbonaceous material that naturally accrues from the environment on the surface of atmospheric exposed metal parts. To test basic cleaning techniques for AC control, metal surfaces commonly used for flight hardware and curating astromaterials at JSC were cleaned using a basic cleaning protocol and characterized for AC residue. Two electropolished stainless steel 316L (SS- 316L) and two Al 6061 (Al-6061) test coupons (2.5 cm diameter by 0.3 cm thick) were subjected to precision cleaning in the JSC Genesis ISO class 4 cleanroom Precision Cleaning Laboratory. Afterwards, the samples were analyzed by X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy.

Calaway, M. J.↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sealing and External Sterilization of a Sample Container

A method of (1) sealing a sample of material acquired in a possibly b iologically contaminated ("dirty") environment into a hermetic conta iner, (2) sterilizing the outer surface of the container, then (3) d elivering the sealed container to a clean environment has been propos ed. The method now proposed was originally intended to be used to ret urn samples from Mars to Earth, but could also be used on Earth to t ransport material samples acquired in environments that contain biol ogical hazards and/or, in some cases, chemical hazards.

Bar-Cohen, Yoseph↗

Separation and Sealing of a Sample Container Using Brazing

A special double-wall container and a process for utilizing the container are being developed to enable (1) acquisition of a sample of material in a dirty environment that may include a biological and/or chemical hazard; (2) sealing a lid onto the inner part of the container to hermetically enclose the sample; (3) separating the resulting hermetic container from the dirty environment; and (4) bringing that hermetic container, without any biological or chemical contamination of its outer surface, into a clean environment. The process is denoted S(exp 3)B (separation, seaming, and sealing using brazing) because sealing of the sample into the hermetic container, separating the container from the dirty environment, and bringing the container with a clean outer surface into the clean environment are all accomplished simultaneously with a brazing operation.

Bar-Cohen, Yoseph↗

Assessing the Oxygen Permeability of Candidate Asteroid Sample Containers With Optochemical Sensors

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center currently curates 500 mg (10%) of carbonaceous asteroid Ryugu regolith collected by the Japan Aerospace and Exploration Agency’s Hayabusa II spacecraft and returned to Earth in 2021. In September 2023, NASA’s OSIRIS-REx spacecraft returned at least 70 grams of regolith collected from the surface of Carbonaceous Asteroid Bennu. These new astromaterials collections are stored and handled in gloveboxes and desiccators that are continuously purged with ultrapure nitrogen in order to minimize contamination and alteration of extraterrestrial samples from terrestrial environments, e.g., reaction with terrestrial oxygen and water. Ito et al. have previously reported on the development of containers to transport samples between facilities in inert, sealed environments; Hayabusa2 samples allocated to investigators by JAXA’s Extraterrestrial Sample Curation Center (ESCuC) are shipped in these Facility-to-Facility Transfer Containers (FFTCs). NASA curation has also been investigating sealed containers for storage, transportation, and allocation of Bennu and Ryugu regolith in sealed anoxic environments. In order to assess the ability of candidate sample containers to maintain nitrogen environments, we have utilized optochemical sensors to measure trace oxygen levels within sealed volumes.

C J Snead↗

Monte-Carlo simulation of nano-collected current from a silicon sample containing a linear arrangement of uncapped nanocrystals

A Monte-Carlo simulation algorithm is used to study electron beam induced current in an intrinsic silicon sample, which contains at its surface a linear arrangement of uncapped nanocrystals positioned in the irradiation trajectory around the hemispherical collecting nano-contact. The induced current is generated by the use of electron beam energy of 5 keV in a perpendicular configuration. Each nanocrystal is considered as a recombination center, and the surface recombination velocity at the free surface is taken to be zero. It is shown that the induced current is affected by the distance separating each nanocrystal from the nano-contact. An increase of this separation distance translates to a decrease of the nanocrystals density and an increase of the minority carrier diffusion length. The results reveal a threshold separation distance from which nanocrystals have no more effect on the collection efficiency, and the diffusion length reaches the value obtained in the absence of nanocrystals. A cross-section characterizing the nano-contact ability to trap carriers was determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal and Evolved Gas Analysis of Geologic Samples Containing Organic Materials: Implications for the 2007 Mars Phoenix Scout Mission

The Thermal and Evolved Gas Analyzer (TEGA) instrument scheduled to fly onboard the 2007 Mars Phoenix Scout Mission will perform differential scanning calorimetry (DSC) and evolved gas analysis (EGA) of soil samples and ice collected from the surface and subsurface at a northern landing site on Mars. We have been developing a sample characterization data library using a laboratory DSC integrated with a quadrupole mass spectrometer to support the interpretations of TEGA data returned during the mission. The laboratory TEGA test-bed instrument has been modified to operate under conditions similar to TEGA, i.e., reduced pressure (e.g., 100 torr) and reduced carrier gas flow rates. We have previously developed a TEGA data library for a variety of volatile-bearing mineral phases, including Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates. Here we examine the thermal and evolved gas properties of samples that contain organics. One of the primary objectives of the Phoenix Scout Mission is to search for habitable zones by assessing organic or biologically interesting materials in icy soil. Nitrogen is currently the carrier gas that will be used for TEGA. In this study, we examine two possible modes of detecting organics in geologic samples; i.e., pyrolysis using N2 as the carrier gas and combustion using O2 as the carrier gas.

Lauer, H. V., Jr.↗

ECTFE (HALAR) as a New Material for Primary Sample Containment of Astromaterials

Fluoropolymers, such as Teflon® (PTFE, PFA, FEP) and Viton® (FKM), have been used for over 40 years in curating astromaterials at NASA JSC. In general, fluoropolymers have low outgassing and particle shedding properties that reduce cross-contamination to curated samples. Ethylene - Chlorotrifluoroethylene (ECTFE), commonly called Halar® (trademark of Solvay Solexis), is a partially fluorinated semi-crystalline copolymer in the same class of fluoropolymers with superior abrasion resistance and extremely low permeability to liquids, gases, and vapors than any other fluoropolymer (fig. 1). ECTFE coatings are becoming more popular in the nuclear, semiconductor, and biomedical industry for lining isolation containment gloveboxes and critical piping as well as other clean room applications. A study was conducted at NASA JSC to evaluate the potential use of Halar on future sample return missions as a material for primary sample containment.

Calaway, Michael J.↗