Advanced Sine Wave Modulation of Continuous Wave Laser System for Atmospheric CO2 Differential Absorption Measurements

NASA Langley Research Center in collaboration with ITT Exelis have been experimenting with Continuous Wave (CW) laser absorption spectrometer (LAS) as a means of performing atmospheric CO2 column measurements from space to support the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission.Because range resolving Intensity Modulated (IM) CW lidar techniques presented here rely on matched filter correlations, autocorrelation properties without side lobes or other artifacts are highly desirable since the autocorrelation function is critical for the measurements of lidar return powers, laser path lengths, and CO2 column amounts. In this paper modulation techniques are investigated that improve autocorrelation properties. The modulation techniques investigated in this paper include sine waves modulated by maximum length (ML) sequences in various hardware configurations. A CW lidar system using sine waves modulated by ML pseudo random noise codes is described, which uses a time shifting approach to separate channels and make multiple, simultaneous online/offline differential absorption measurements. Unlike the pure ML sequence, this technique is useful in hardware that is band pass filtered as the IM sine wave carrier shifts the main power band. Both amplitude and Phase Shift Keying (PSK) modulated IM carriers are investigated that exibit perfect autocorrelation properties down to one cycle per code bit. In addition, a method is presented to bandwidth limit the ML sequence based on a Gaussian filter implemented in terms of Jacobi theta functions that does not seriously degrade the resolution or introduce side lobes as a means of reducing aliasing and IM carrier bandwidth.

Campbell, Joel F.

HBr-CO2 continuous-wave chemical laser

Continuous wave chemical laser operation at 10.6 micron in carbon dioxide pumped by vibrational energy from hydrogen atoms and bromine molecules reaction

Cool, T. A.

In situ x-ray imaging to understand subsurface behavior during continuous wave laser drilling

A limited understanding regarding the underlying dynamics and mechanisms of material removal during continuous wave laser drilling has presented significant challenges in achieving precision and process control. Here, to address this, we employed high-fidelity, in situ synchrotron x-ray imaging to reveal previously unknown material behaviors during continuous wave laser drilling with power modulation. Our findings highlight that high-aspect ratio drill holes are achieved when the laser modulation frequency falls within the range of 8–12 kHz, provided that the laser average power and modulation amplitude levels meet the specified limits. Under these conditions, we identified a material removal mechanism driven by incremental accumulation of recoil pressure that gradually pushes material upward from deep within the substrate to the surface. This mechanism manifested as a low-frequency fluctuation in the vapor depression depth, resulting in periodic instances of material ejection. Furthermore, our study underscores that rapid expansion of the melt pool and the widening of the drill hole opening can impede effective material removal by redirecting energy from material ejection to increasing the melt pool size. This investigation contributes essential insights into the subsurface dynamics involved in the drilling of high-aspect ratio holes, furthering our fundamental understanding of this intricate process.

47 OTHER INSTRUMENTATION

A model for a continuous-wave iodine laser

A model for a continuous-wave (CW) iodine laser has been developed and compared with the experimental results obtained from a solar-simulator-pumped CW iodine laser. The agreement between the calculated laser power output and the experimental results is generally good for various laser parameters even when the model includes only prominent rate coefficients. The flow velocity dependence of the output power shows that the CW iodine laser cannot be achieved with a flow velocity below 1 m/s for the present solar-simulator-pumped CW iodine laser system.

Hwang, In H.

Tunable diode laser-pumped Tm,Ho:YLF laser operated in continuous-wave and Q-switched modes

Tunable continuous-wave and pulsed laser output was obtained from a Tm-sensitized Ho:YLiF4 crystal at subambient temperatures when longitudinally pumped with a diode laser array. A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to the absorbed pumped power have been achieved at a crystal temperature of 275 K. The emission spectrum was etalon tunable over a range of 16/cm centered at 2067 nm with fine tuning capability of the transition frequency with crystal temperature at measured rate of -0.03/cm/K. Output energies of 0.22 mJ per pulse and 22 ns pulse duration were recorded at Q-switch frequencies that correspond to an effective upper laser level lifetime of 6 ms, and a pulse energy extraction efficiency of 64 percent.

Mcguckin, B. T.

Interference of Backscatter from Two Droplets in a Focused Continuous Wave CO2 Doppler Lidar Beam

Using a focused continuous wave CO2 Doppler lidar at wavelength 9.1 microns the interference of the superposition of backscatter from two approx. 14.12 microns diameter silicone oil droplets in the lidar beam was observed. This interference results in a single backscatter pulse from the two droplets with a distinct periodic structure. The interference is due to the phase difference in backscatter from the two droplets while they are traversing the lidar beam because they are moving at different speeds and, thus, the droplet separation is not constant. The complete cycle of interference, with periodicity of 2(Pi), gives excellent agreement between measurements and lidar theory.

Jarzembski, Maurice A.

Vertical Aerosol Backscatter Variability from an Airborne Focused Continuous Wave CO2 Lidar

Atmospheric aerosol backscatter measurements using a continuous wave focused Doppler lidar at 9.1 micron wavelength were obtained over western North America and the Pacific Ocean during 13 - 26 September, 1995 as part of National Aeronautics and Space Administration's (NASA) Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) mission on board the NASA DC8 aircraft. Backscatter variability was measured for approximately 52 flight hours, covering equivalent horizontal distance of approximately 25,000 km in the troposphere. Quasi-vertical backscatter profiles were also obtained during various ascents and descents which ranged between approximately 0.1 to 12.0 km altitude. Aerosol haze layers were encountered at different altitudes. Similarities and differences for aerosol loading over land and over ocean were observed. A mid-tropospheric aerosol backscatter background mode was found with modal value approximately 1O(exp -10)/m/sr, consistent with previous airborne and ground-based datasets.

Jarzembski, Maurice A.

Interference of Backscatter from Two Droplets in a Focused Continuous-Wave CO2 Doppler Lidar Beam

With a focused continuous-wave CO2 Doppler lidar at 9.1-microns wavelength, the superposition of backscatter from two approximately 14.12-micron-diameter silicone oil droplets in the lidar beam produced interference that resulted in a single backscatter pulse from the two droplets with a distinct periodic structure. This interference is caused by the phase difference in backscatter from the two droplets while they are traversing the lidar beam at different speeds, and thus the droplet separation is not constant. The complete cycle of interference, with periodicity 2(pi), gives excellent agreement between measurements and lidar theory.

Jarzembski, Maurice A.

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Improved formula for continuous-wave measurements of ultrasonic phase velocity

An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

Chern, E. J.

Airborne coherent continuous wave CO2 Doppler lidars for aerosol backscatter measurement

Two focused coherent, continuous wave (CW) lidars have been developed by the Marshall Space Flight Center (MSFC) for airborne and ground-based measurement of aerosol backscatter coefficients. The first of these instruments uses a mixture of CO2 and other gases, and measures backscatter at 10.6 m. The second lidar uses an isotope of carbon dioxide, which enables lasing at 9.1 m. The 10.6 m backscatter measurement serves as a reference to allow variations in backscatter due to aerosol concentration to be distinguished from variations due to spectral variability. The 10.6 m lidar has been used in airborne field programs since 1981. Development of the 9.1 m lidar was completed in early 1989. Recently, both lidars were flown on the NASA/Ames Research Center DC-8 research aircraft in the remote Pacific Basin as part of the NASA GLObal Backscatter Experiment (GLOBE) survey missions. The GLOBE program, of which the survey missions are the centerpieces, supports design and simulation studies for NASA's prospective Laser Atmospheric Wind Sounder (LAWS).

Rothermel, Jeffry

Signal Processing and Calibration of Continuous-Wave Focused CO2 Doppler Lidars for Atmospheric Backscatter Measurement

Two continuous-wave(CW)focused C02 Doppler lidars (9.1 and 10.6 micrometers) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic and spectrum analyzer and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is approximately 3 x 10(exp -12)/m/sr at 9.1 micrometers and approximately 9 x 10(exp -12)/m/sr at 10.6 micrometers. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6 micrometer lidar intercomparisons were made. Measurements at 9.1 micrometers, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope C-12 O(2)-18 gas.

Rothermel, Jeffry

Mid-infrared trace gas detection using continuous-wave difference frequency generation in periodically poled RbTiOAsO4

A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating near 713 nm and 871 nm, respectively, using a laser pump power of 300 mW. A quasi-phase-matched infrared wavelength-tuning bandwidth (FWHM) of ~ 12 cm-1 and a temperature tuning rate of 1.02 cm-1/degree C were achieved. Experimental details regarding the feasibility of trace gas detection based on absorption spectroscopy of CO2 in ambient air using this DFG radiation source are also described.